General specifications
Input unit
Alarm function
Reference performance
Others
Optional specifications
Mathematics function
Display unit
Recording function
Mounting method
Material
External dimensions
and mass
Power supply voltage
Power consumption
External terminals
Operate temperature
No. of inputs
Measuring cycles
Recording cycle
Input signal
Input types
Burn-out function
Calculation function
Formula
Input signal
Display
Life of backlight
Display contents
Recording medium
Memory capacity
Recording method
Data save cycles
Data format
Trend data
Event data
Totalized data
Storage capacity
Amount of memory
used
No. of settings
Type of alarm
Indication
Output
Indication accuracy
Indication resolution
Reference junction
Compensation accuracy
Input resistance
Clock
Memory backup
Memory full alarm
Low battery alarm
Alarm relay output
Panel flush mounted
steel sheet for case, PC-ABS for bezel
<Panel mount>
300 x 300 x 220.5 mm, about 4.7 kg (9-point input)
100V to 240V AC, 50/60 Hz
About 80VA (at 240VAC)
Screw terminals (M3 thread)
0 to 50˚C (in case the 12th digits of code
symbols is “Y”.)
0 to 40˚C (in case the 12th digits of code symbol
is “E” .)
9 or 18 or 27 or 36 points
100ms/9, 18 points 200ms/27, 36 points
1sec to 12hours
Thermocouple: 12 types
(B, R, S, K, E, J, T, N, W, L, U, PN)
Resistance bulb: 5 types
(Pt100, JPt100, Ni100, Pt50, Cu50)
DC voltage:
(0 to 50mV, 0 to 500mV, 0 to 5V or 1 to 5V)
DC current:
(connecting optional shunt resistor to input terminal)
Selected from the key panel
(the same type should be set for every 2 channels)
Equipped with thermocouple and resistance bulb
inputs as standard.
Primary delay filter, scaling, calculation of
difference between channels, F value calculation,
totalization, and square root extraction
It can be set 1 main formula and 3 temporary one.
Addition, Subtraction, Multiplication, Division
Absolute value, X to the power of Y, Logarithm,
Natural logarithm, Exponential function,
Humidity, Average value, Maximum value,
Minimum value.
DI (DI1 to DI16), Totalize (ch1 to ch72), Analog
input (ch1 to ch72), Constant (No.1 to No.60),
Communication input (No.1 to No.36)
12" TFT color LCD (800 X 600 dots) (The LCD
may have some pixels that do not stay on or off.
Due to the characteristics of liquid crystal, the
brightness may not be uniform, which is not a
failure.)
50,000 hours
•Trend display
(in vertical and horizontal direction) selected in
the refreshment cycles of 1 sec to 12 hours.
Scale display/non-display selectable
•Bar graph or analog meter display (refresh
cycle: 1 second)
•Digital display (in refreshment cycle of 1 sec)
•Event summary display (alarm and message
summary)
•Historical trend display (Compact Flash memory
data.)
•Totalized data display
•Group setting (8 groups at the maximum)
Compact Flash card (Format as FAT16 or FAT, or
recorder can’t read and write.)
512MB, max.
Writing starts in fixed cycles by turning ON the
REC key on the front panel.
Data is recorded in a new file every time the
recording starts.
Links to refreshment cycle of the trend display
•ASCII About 166 bytes per sampling
(at 9 channel inputs)
•Binary (Data cannot be read directly into Excel,
etc.)
About 40 bytes per 1 sampling (9-channel input)
Maximum value and minimum value are saved
from the data that are sampled in measuring
cycles.
Alarm data and message data are saved.
Stores data totalized during specified period of
time.
•About 1.5 years at display refresh cycle of 30
seconds (ASCII)
•About 6 years (Binary)
(9-channel recording, 256MB compact flash used)
The display unit displays how much the memory
card has been used via bar graphs. The
recording will stop if the amount of recorded data
exceeds the capacity.
Up to 4 alarms are settable for each channel.
High/Low limits
Alarm status is displayed on digital display unit
when an alarm occurs. Histories are displayed in
the alarm summary.
20 points as relay output (option)
16 points as open-collector transister output (option)
±(0.15%+1 digit) of input range
Accuracy of the next range is ±(0.3%+1 digit).
Thermocouple B: 400˚C to 600C, thermocouples
R and S: 0˚C to 300˚C, thermocouples K, E, J, T,
L, and U: -200˚C to -100˚C
0.1˚C
±0.5˚C
(Thermocouples R, S, B and W: ±1.0˚C)
About 1M
With calendar function
Parameter settings are saved to the internal nonvolatile memory. The clock is backed up by a
built-in lithium battery. Trend data is back up
5 Mbyte.
When the amount of recorded data exceeds the
capacity of memory card, recorder can energize
the alarm output.
When the battery for backup of clock and SRAM
becomes low, recorder can energize the alarm
output.
Up to 2 pieces of card, having 10-point relay
output, can be mounted
(max.20points).
Alarm output: 1 a contact
Alarm setting: individual channel or common
output is available.
Specifications