High Perfomance
Compact Body
Welcome to the
NEXT Generation
of Compact Inverters
S
New
NEXT
Generation!
24A1-E-0011d
High Performance
Fully Compatible
Easy Operation
and
Multipurpose
New Compact Inverter
Get Our Most User-Friendly Inverter yet!
with
Existing Products
High Performance Compact Body.
NEXT Generation!
COMPACT
INVERTER
and
Maintenance
FRENIC
FUJI ELECTRIC INVERTERS
High Perfomance Compact Body.
Welcome to the NEXT Generation of Compact Inverter
With its functionality, compact design, simple operation, and global compatibility,
the new FRENIC-Mini elevates the performance of a wide range of devices and equipment--including conveyors,
fans, pumps, centrifugal separators, and food processing machines--to give you the system integration,
energy efficiency, reduced labor, and lower overall costs you're looking for.
Energy
Efficient
2
Network
Capabilities
Global
Compatibility
High Perfomance Compact Body Welcome to the NEXT Generation of Compact Inverters
High Performance and Multipurpose
FUJI ELECTRIC INVERTERS
200
100
0
Output torque [%]
-100
-200
Full Compatibility and User Friendly Design
Current C1 modelNew C2 model
120
(4.72)
3Hz
5Hz
10Hz
120
(4.72)
Motor
speed
[r/min]
Dynamic Torque Vector Control System
Fuji Electric original dynamic torque vector control system is known for its
top-of-the line performance, delivering stabile torque output even at low
speeds. This feature has a wide range of applications, including conveyors
and high-inertia loads that demand high starting torque.
Slip Compensation shortens setting time
The slip compensation controller works with voltage tuning for even more
accurate speed control at low velocity. This reduces speed control variability
and stabilizing creep speed for more accurate stopping in conveyors and
similar equipment.
Fastest CPU Processor in its Class
Advanced CPU processes data at twice the speed of our current model
The contents of this catalog are provided to help you select the product model that is best for you. Before actual use, be sure to read the User’s Manual
The load shall be reduced so that the continuous operating current is the rated current in parenthesis or less if the carrier frequency is set to 3kHz or above or ambient temperature exceeds 40℃ (104℉).
(with DCR)
(without DCR)
Three-phase 200V
FRN C2S-2A, FRN C2S-2U
0001
0.1
1/8
0.30
Three-phase 200 to 240V (With AVR)
0.8(0.7)
150% of rated current for 1min
150% of rated current for 1min or 200% of rated current for 0.5s (If the rated current is in parenthesis)
50, 60Hz
Three-phase, 200 to 240V, 50/60Hz
Voltage: +10 to -15% (Voltage unbalance : 2% or less), Frequency: +5 to -5%
0.57
1.1
0.2
150
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s Braking level: 0 to 100%
−
UL508C, EN 61800-5-1:2007
IP20 (IEC 60529:1989) / UL open type (UL50)
Natural cooling
0.6(1.3)
0002
0.2
1/4
0.57
1.5(1.4)
0.93
1.8
0.3
0.6(1.3)
0004
0.4
1/2
1.3
3.5(2.5)
1.6
3.1
0.6
100
Built-in
0.7(1.5)
0006
0.75
1
2.0
5.5(4.2)
3.0
5.3
1.1
0.8(1.8)
0010
1.5
2
3.5
9.2(7.0)
5.7
9.5
2.0
50
Fan cooling
1.7(3.7)
0012
2.2
3
4.5
12.0(10.0)
8.3
13.2
2.9
30
1.7(3.7)
0020
3.7
5
7.2
19.1(16.5)
14.0
22.2
4.9
2.5(5.5)
0025
5.5
7.5
9.5
25.0(23.5)
150% of rated current for 1min or
200% of rated current for 0.5s
21.1
31.5
7.4
20
3.1(6.8)
0033
7.5
10
12
33.0(31.0)
28.8
42.7
10
3.1(6.8)
0047
11
15
17
47.0(44.0)
42.2
60.7
15
4.5(9.8)
0060
15
20
22
60.0(57.0)
57.6
80.0
20
4.5(9.8)
Three-phase 400V series
ItemSpecifications
Input power source
Type
(FRN C2S-4 , =A, C, E, U)
Nominal applied motor[kW]
( =A, C, E)
Nominal applied motor[HP]( =U)
Rated capacity[kVA]
Rated voltage[V]
Rated current[A](*1)
Overload capability
Output ratingsInput ratingsBraking
Rated frequency[Hz]
Phases, Voltage, Frequency
Voltage/Frequency variations
Rated current[A]
Required power supply capacity[kVA]
Torque[%]
DC injection braking
Braking transistor
Applicable safety standards
Enclosure (IEC 60529)
Cooling method
Weight / Mass[kg(Ibs)]
*1
The load shall be reduced so that the continuous operating current is the rated current in parenthesis or less if the carrier frequency is set to 3kHz or above or ambient temperature exceeds 40℃ (104℉).
(with DCR)
(without DCR)
Three-phase 400V
FRN C2S-4A, FRN C2S-4C
FRN C2S-4E, FRN C2S-4U
0002
0.4
1/2
1.3
Three-phase 380 to 480V (With AVR)
1.8(1.5)
150% of rated current for 1min
150% of rated current for 1min or 200% of rated current for 0.5s (If the rated current is in parenthesis)
50, 60Hz
Three-phase, 380 to 480V, 50/60Hz
Voltage: +10 to -15% (Voltage unbalance : 2% or less), Frequency: +5 to -5%
0.85
1.7
0.6
100
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s Braking level: 0 to 100%
Built-in
UL508C, EN 61800-5-1:2007
IP20 (IEC 60529:1989) / UL open type (UL50)
Natural cooling
1.2(2.6)
0004
0.75
1
2.3
3.1(2.5)
1.6
3.1
1.1
1.3(2.9)
0005
1.5
2
3.2
4.3(3.7)
3.0
5.9
2.0
50
Fan cooling
1.7(3.7)
0007
2.2
3
4.8
6.3(5.5)
4.4
8.2
2.9
30
1.7(3.7)
0011
3.7( =A, C)
4.0( =E)
5
8.0
10.5(9.0)
7.3
13.0
4.9
2.5(5.5)
0013
5.5
7.5
9.9
13.0
150% of rated current for 1min or
200% of rated current for 0.5s
10.6
17.3
7.4
20
3.1(6.8)
0018
7.5
10
13
18.0
14.4
23.2
10
3.1(6.8)
0024
11
15
18
24.0
21.1
33.0
15
4.5(9.8)
0030
15
20
22
30.0
28.8
43.8
20
4.5(9.8)
6
FUJI ELECTRIC INVERTERS
High Perfomance Compact Body Welcome to the NEXT Generation of Compact Inverters
Specifications
Single-phase 200V/100V series
ItemSpecifications
Input power source
Type
(FRN C2S- , =A, C, E, U)
Nominal applied motor[kW]
( =A, C, E)
Nominal applied motor[HP]( =U)
Rated capacity[kVA]
Rated voltage[V]
Rated current[A](*1)
Overload capability
Output ratingsInput ratingsBraking
Rated frequency[Hz]
Phases, Voltage, Frequency
Voltage/Frequency variations
Rated current[A]
Required power supply capacity[kVA]
Torque[%]
DC injection braking
Braking transistor
Applicable safety standards
Enclosure (IEC 60529)
Cooling method
Weight / Mass[kg(Ibs)]
*1
The load shall be reduced so that the continuous operating current is the rated current in parenthesis or less if the carrier frequency is set to 3kHz or above or ambient temperature exceeds 40℃ (104℉).
(with DCR)
(without DCR)
Single-phase 200V
FRN C2S-7A, FRN C2S-7C
FRN C2S-7E, FRN C2S-7U
0001
0.1
1/8
0.30
Three-phase 200 to 240V (With AVR)
0.8(0.7)
150% of rated current for 1min
150% of rated current for 1min or 200% of rated current for 0.5s (If the rated current is in parenthesis)
50, 60Hz
Single-phase, 200 to 240V, 50/60Hz
Voltage: +10 to -10%, Frequency: +5 to -5%
1.1
1.8
0.3
150
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 100%
−
UL508C, EN 61800-5-1:2007
IP20 (IEC 60529:1989) / UL open type (UL50)
Natural cooling
0.6(1.3)
0002
0.2
1/4
0.57
1.5(1.4)
2.0
3.3
0.4
0.6(1.3)
0004
0.4
1/2
1.3
3.5(2.5)
3.5
5.4
0.7
100
Built-in
0.7(1.5)
0006
0.75
1
2.0
5.5(4.2)
6.4
9.7
1.3
0.9(2)
0010
1.5
2
3.5
9.2(7.0)
11.6
16.4
2.4
50
Fan cooling
1.8(4)
0012
2.2
3
4.5
12.0(10.0)
17.5
24.0
3.5
30
2.5(5.5)
Single-phase 100V
FRN C2S-6U
0001
0.1
1/8
0.26
0.7
150% of rated current for 1min
or 200% of rated current for 0.5s
Applicable EMC standards
(EN61800-3:2004 +A1:2012)
(in progress)
Enclosure (IEC 60529)
Cooling method
Weight / Mass[kg(Ibs)]
*1
The load shall be reduced so that the continuous operating current is the rated current in parenthesis or less if the carrier frequency is set to 3kHz or above or ambient temperature exceeds 40℃ (104℉).
(with DCR)
(without DCR)
Three-phase 400V
FRN C2E-4E
0002
0.4
1/2
1.3
Three-phase 380 to 480V (With AVR)
1.8(1.5)
150% of rated current for 1min
150% of rated current for 1min or 200% of rated current for 0.5s (If the rated current is in parenthesis)
50, 60Hz
Three-phase, 380 to 480V, 50/60Hz
Voltage: +10 to -15% (Voltage unbalance : 2% or less), Frequency: +5 to -5%
0.85
1.7
0.6
100
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s Braking level: 0 to 100%
Built-in
UL508C, EN 61800-5-1:2007
Immunity : Second Environment (Industrial)
Emission : Category C2
IP20 (IEC 60529:1989) / UL open type (UL50)
Natural cooling
1.5(3.3)
0004
0.75
1
2.3
3.1(2.5)
1.6
3.1
1.1
1.6(3.5)
0005
1.5
2
3.2
4.3(3.7)
3.0
5.9
2.0
50
Fan cooling
3.0(6.6)
0007
2.2
3
4.8
6.3(5.5)
4.4
8.2
2.9
30
3.1(6.8)
0011
4.0
5
8.0
10.5(9.0)
7.3
13.0
4.9
3.2(7.1)
0013
5.5
7.5
9.9
13
150% of rated current for 1min or
200% of rated current for 0.5s
10.6
17.3
7.4
20
Immunity : Second Environment (Industrial)
Emission : Category C3
4.6(10.1)
0018
7.5
10
13
18
14.4
23.2
10
4.6(10.1)
0024
11
15
18
24
21.1
33.0
15
6.7(15)
0030
15
20
22
30
28.8
43.8
20
6.7(15)
Single-phase 200V series
ItemSpecifications
Input power source
Type
(FRN C2E-7E)
Nominal applied motor[kW]
Nominal applied motor[HP]
Rated capacity[kVA]
Rated voltage[V]
Rated current[A](*1)
Overload capability
Output ratingsInput ratingsBraking
Rated frequency[Hz]
Phases, Voltage, Frequency
Voltage/Frequency variations
Rated current[A]
Required power supply capacity[kVA]
Torque[%]
DC injection braking
Braking transistor
Applicable safety standards
Applicable EMC standards
(EN61800-3:2004 +A1:2012)
(in progress)
Enclosure (IEC 60529)
Cooling method
Weight / Mass[kg(Ibs)]
*1
The load shall be reduced so that the continuous operating current is the rated current in parenthesis or less if the carrier frequency is set to 3kHz or above or ambient temperature exceeds 40℃ (104℉).
(with DCR)
(without DCR)
Single-phase 200V
FRN C2E-7E
0001
0.1
1/8
0.30
Single-phase, 200 to 240V, 50/60Hz
0.8(0.7)
150% of rated current for 1min
150% of rated current for 1min or 200% of rated current for 0.5s (If the rated current is in parenthesis)
50, 60Hz
Single-phase, 200 to 240V, 50/60Hz
Voltage: +10 to -10%, Frequency: +5 to -5%
1.1
1.8
0.3
150
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 100%
−
UL508C, EN 61800-5-1:2007
Immunity : Second Environment (Industrial)
Emission : Category C2
IP20 (IEC 60529:1989) / UL open type (UL50)
Natural cooling
0.7(1.5)
0002
0.2
1/4
0.57
1.5(1.4)
2.0
3.3
0.4
0.7(1.5)
0004
0.4
1/2
1.3
3.5(2.5)
3.5
5.4
0.7
100
Built-in
0.8(1.8)
0006
0.75
1
2.0
5.5(4.2)
6.4
9.7
1.3
1.2(2.6)
0010
1.5
2
3.5
9.2(7.0)
11.6
16.4
2.4
50
Fan cooling
3.0(6.6)
0012
2.2
3
4.5
12.0(10.0)
17.5
24.0
3.5
30
3.0(6.6)
8