Fuji Electric FRENIC 5000G11S/P11S Instruction Manual Supplement

Instruction Manual
Addendum
This is an update to the Instruction Manual publication number INR-S147-1206-E. New or revised information is highlighted for easy identification.
Fuji Electric Systems Co., Ltd FECA-TE-112A Fuji Electric Corp of America 07/2010
1. Standard Specifications
Items
Specifications
Nominal applied motor for three phase input [HP]
Rated output capacity *1 [kVA]
Rated output current *2 [A]
Rated output capacity *1 [kVA]
Rated output current *2 [A]
Braking duty cycle [%ED]
10 5 3 5 3 2 3
2
No limit
Mass [lbs(kg)]
4.9
4.9
5.5
8.4
8.4
8.4
13
13
22
22
23
23
64
79
97
101
154
254
Type for three phase input [HP]
Rated output capacity *1 [kVA]
Rated output current
[A]
Rated output capacity *1 [kVA]
Rated output current *2 [A]
Overload capability
110% of rated output current for 1 min.
Starting torque
50% or more
Braking torque *3 [%]
Approx. 20%
Approx. 10 to 15%
Braking time [s]
No limit
Braking duty cycle [%ED]
Mass [lbs(kg)]
13
(5.7)
13
(5.7)
13
(5.7)
22
(10)
22
(10)
23
(10.5)
64
(29)
64
(29)
79
(36)
97
(44)
101 (46)
154 (70)
254
(115)
ratings
Rated output frequency [Hz]
Phases, voltage, frequency for three phase input
3-phase, 200 to 220V / 50Hz 3-phase, 200 to 230V / 60Hz
Phases, voltage, frequency for single phase input
Single-phase, 200 to 220V / 50Hz Single-phase, 200 to 230V / 60Hz
Voltage/frequency variations for three phase input
Voltage/frequency variations for single phase input
Momentary voltage dip capability *6
Operation will c on tin ue wit h 165V or mor e. I f voltage drops bel o w 1 65 V, o per ation will continue for up t o 1 5 m s. If "Contin uo us op er ati o n" i s selected, the output frequency will be lowered to withstand the load until normal voltage is resumed.
for single phase input *7 [kVA]
Required power supply capacity for three phase input *7 [kVA]
Required power supply capacity for single phase input *7 [kVA]
67[%]
[V] voltage average phase-3
[V]) voltage Min.[V] Voltage(Max.
[%] phases between rate Imbalance ×
=
1) 230V series (G11S: 1/4 to 125HP, P11S: 7.5 to 150HP)
Type FRN□□□G11S-2UX
F25 F50 001 002 003 005 007 010 015 020 025 030 040 050 060 075 100 125
1/4 1/2
1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125
0.6 1.2 2.0 3.2 4.4 6.8 10 13 18 24 29 35 46 58 72 86 113 138
input
Three phase
input
G11
Single phase
Overload capability 150% of rated output current for 1 min. Starting torque 200% or more(under torque vector control)
Braking torque *3 [%]
1.5 3.0 5.0 8.0 11 17 25 33 46 59 74 87 115 145 180 215 283 346
0.3 0.6 1.0 1.6 2.3 3.9 5.0 6.8 9.3 11 14 16 21 27 32 34 39 47
1.0 1.7 2.8 4.6 6.6 11 14 19 26 33 39 47
59.4 150% of rated output cur r ent for 1 min.
200% of rated output current for 0.5 s
180% of rated output current for 0.5 s 180% or more(unde r torq ue vector control)
150% or more
100% or more Approx. 20% Approx. 10 to 15%
Braking time [s] 10 5 5 No limit
(2.2)
(2.2)
(2.5)
(3.8)
(3.8)
(3.8)
(6.1)
(6.1)
(10)
(10)
(10.5)
(10.5)
(29)
FRN□□□P11S-2UX Nominal applied motor
007 010 015 020 025 030 040 050 060 075 100 125 150 ― 7.5 10 15 20 25 30 40 50 60 75 100 125 150 ― 8.8 12 17 22 27 31 46 58 72 86 113 138 165
input
Three phase
P11
*2
input
Single phase
22 29 42 55 ― ― ―
4.6 6.1 8.7 11 12 16 21 27 32 34 36 44 51 13 17
24.2
31 36
68 80
46.2 59.4
115 145 180 215 283 346 415
75 91 95
(36)
(44)
(46)
75 91 95
109 131
(115)
(70)
102 123 143
No limit
Rated output voltage *4 [V]
Output
3-phase, 200V/50Hz, 200V,220V,230V/60Hz 50,60Hz
3-phase, 200 to 230V, 50/60Hz Single-phase, 200 to 230V, 50/60Hz Voltage: +10% to -15% (Imbalance rate between phases: 2% or less *5, Frequency: +5% to -5% Voltage: +10% to -10%, Frequency: +5% to -5%
Required power supply capacity
Input ratings
for three phase input
G11
Required power supply capacity
*7
[kVA]
P11
Note: *1 Indicated capacities are at the rated output voltage 230V for the three-phase input and 208V for the single-phase input. The rated capacity will be lowered if the supply voltage is lowered. *2 In the case of a low impedance load, such as a high-frequency motor, the current may drop below the rated current. *3 Indicates when a nominal applied motor is used (the average torque when decelerated to stoppage from 60 Hz, which varies depending on motor loss). *4 An output voltage exceeding the supply voltage cannot be generated. *5 If the imbalance between phases exceeds 2%, use a power-factor correcting DC reactor (DCR).
0.4 0.7 1.3 2.2 3.1 5.0 7.2 9.7 15 20 24 29 38 47 56 69 93
111
0.3 0.5 0.8 1.4 2.0 3.8 5.2 7.1 11 14 17 20 27 33 39 48 51 59
― ―
7.2 9.7 15 20 24 29 38 47 56 69 93
111 134
5.2 7.1 11 14 17 20 27 33 39 42 47 55 65
― ―
b)
*6 Test was conducted under the standard load conditions stipulated by the JEMA committee (at the load equivalent to 85% of the nominal applied motor). *7 Indicates the values required when using a power-factor correcting DC reactor (DCR) (optional for inverters of 75HP or less) with a loaded nominal applied motor.
- When utilized on a single phase input applications the drive’s output voltage may be lower than the nominal rated voltage.