Fuji Electric FLSE12 Data sheet

Time Delta M-Flow
Full-Feature Transit-Time Ultrasonic Flow Meter System at an Affordable Price
The Time Delta M-Flow is a state-of-the-art, economical alternative to magnetic, vortex and differential pressure transmitters. Advanced microprocessing detection methods combine with a versatile design to provide accurate and obstructionless flow measurement of clean water applications. The Time Delta M-Flow features high reliability and accuracy (up to 0.5%), and long-term maintenance-free operation. Programming the M-Flow is simple via the front panel keypad; no PC is required for setup. The instrument features a high-resolution, 2-line, backlit display and signal quality indication. The non-intrusive, clamp-on sensors are quickly installed without interrupting process flows or incurring pressure loss.
Features
Flexible output options – Analog output,
totalizer pulse, relay outputs all included as standard options
Fast and easy installation – Simple,
menu-driven user interface enables quick setup without need to connect to a laptop PC
Compact and lightweight
Incorporates the latest LSI technology for compact, rugged design. Meter weighs less than 2 lbs
Quick response – Ultra-fast transit-time
processing (200 ms) suits high-speed batch processing measurements
Multilingual – Instrument setup and
display supported in English, Spanish, German and French
Superior temperature effect
Proprietary temperature and pressure compensation system completely eliminates error created by process temperature and pressure fluctuations
Performance Specifications for the Converter
Fluid Conditions
Measured fluid Homogeneous liquids
with minimal aeration (water, sea water, hydrocarbons or fluid with unknown sound velocity) capable of ultrasonic wave propagation
Fluid turbidity 10000 deg. (mg/l) or less State of flow Well developed turbulent or
laminar flow in full pipe
Fluid temperature -4 to 212°F (-20 to 100°C) Velocity range 0.010 to 33 ft/sec (0 to 10
m/sec) bi-directional flow
Piping Conditions
Pipe material Carbon steel, stainless steel,
cast iron, copper, PVC, aluminum, FRP, PEEK, PVDF, PTFE, PFA and other
Pipe size 1.0 to 9.0 in. (25 to 225mm) Lining material Tar, epoxy, mortar, rubber,
other, none
Information subject to change without notice. Prices in USD. 4-12
Measurement Accuracy
Accuracy Up to 0.5%, ±2% rate typical on
calibrated system
Linearity ±0.1% of scale Repeatability 0.5% or better
Functional Specifications for the Converter
Power supply 100 to 120 VAC ±10%, 50/60
Hz; 200 to 240 VAC ±10%, 50/60 Hz; 20 to 30 VDC
Power consumption Approx. 10 VA/5W (DC) LCD display 2 line, 16 character per line,
backlight
LED display 2 color, green/red, signal
quality
Keypad 4-key, full menu-driven setup
functionality
Response time 200 ms or less Analog output signal 4 to 20mA DC,
multirange, fully programmable
Digital output signal Digital output 2
mechanical relay, 1 point with socket. Normal open/close selectable, capacity 220 VAC/30 VDC, 1 Amp. Total pulse range: 1 pulse per day to 1 pulse per second. Digital output: 1 open collector transistor, 1 point. Normal on/off selectable, capacity 30 VDC, 0.1 Amp. Total pulse range: 1 pulse per day to 100 pps.
Digital output functions Forward/reverse
totalizer pulse, flow switch high/low, forward/reverse total alarm and overflow, reverse flow detected
Communications interface RS-232C/RS-
485. Data: velocity, flow rate, +total,
-total, status. Cable length: 50 ft. (15m) for RS-232C, 3280 ft (1000m) for RS-485. Number of connectable units: 31 (RS485), 1 (RS232C)
Display language English, French, German,
Spanish
Measurement display screen System
units: English or metric, keypad selectable. LCD display: Configurable from keypad, select from among forward totalizer value,
Key Features
Flexible output options
Fast and easy installation
Compact and lightweight
Quick response
Superior temperature effect
Ultrasonic Flow Meters Fuji Time Delta M-Flow
1
Time Delta M-Flow
Specifications (continued)
Ultrasonic Flow Meters Fuji Time Delta M-Flow
reverse totalizer value, flow velocity, output range percentage and flow rate. Velocity/flow rate display: 7 digits. Velocity units: English (ft/sec), metric (m/sec). Flow rate units: English (gal/sec, gal/min, gal/hr, kgal/hr, Mgal/d, ft3/sec, ft3/min, ft3/hr, Mft3/d, BBL/sec, BBL/min, BBL/hr, MBBL/d), Metric (L/sec, L/min, L/hr, kL/hr, ML/d, m3/sec, m3/min, m3/hr, Mm3/d, BBL/sec, BBL/hr, BBL/min, MBBL/ d). Totalizer display: 7 digits. Totalizer units English (gal, kgal, ft3, kft3, Mft3, mBBL, BBL, kBBL, ACRE-in, ACRE-ft), Metric (mL, L, m3, km3, Mm3, mBBL, BBL, kBBL). Zero adjustment: Automatic or manual zero flow reference setting, keypad selectable. Damping function: 0 to 100 sec, keypad selectable. Low flow cutoff: 0 to 16.4 ft/sec (0 to 5 m/sec). Burnout function: Analog output, hold/overscale/underscale/ zero, keypad selectable; Totalizer, hold/ count, keypad selectable; Working timer, 0 to 100 sec, keypad selectable
Physical Specifications for the Converter
Ambient temperature -4 to 140°F (-20 to
60°C)
Ambient humidity Less than 90% RH Enclosure ABS Plastic Environmental rating NEMA-4X (IP65) Dimensions (HxWxD) 5.51 x 5.47 x 2.68
in. (140 x 139 x 68mm)
Weight 1.76 lbs. (0.8 kg)
Detector Model FLS
Mounting method Detector mounting on
outside of pipe via steel bands, nylon belts, or steel wire
Straight pipe length Upstream side: 10D
or more recommended. downstream side: 5D or more recommended (Calibrated
system conditions include a minimum of 10 inner pipe diameters of upstream straight pipe run and a minimum of 5 inner
pipe diameters of downstream pipe run. Longer runs may be necessary due to pipe configurations.)
Signal cable RG-58, RG-58A/U, 3D2V Cable length Standard length 16 ft.,
maximum length 100 ft. (30m)
Connection Converter: internal screw.
Detector: BNC (female)
Operating characteristics (pipe diameter
range/temperature range)
FLSE12: 1.0 to 4.0 in (25 to 100mm)/-4 to 212°F (-20 to 100°C). FLSE22: 2.0 to 9.0 in (50 to 225mm)/-4 to 212°F (-20 to 100°C)
Ambient temperature range -4 to 212°F
(-20 to 100°C)
Environmental rating IP65 Material FLSE12 & FLSE22: Plastic PBT
housing, stainless steel mounting bracket
Dimension (WxHxD)/Weight FLSE12:
9.45 x 1.10 x 2.00 in./0.7 lbs. (240 x
27.9 x 50.8mm/0.3 kg); FLSE22: 14.20 x 1.10 x 2.00 in./0.9 lbs. (360.7 x 27.9 x
50.8mm/0.4 kg)
We attempt to provide you with complete information in this catalog. Because of the specific nature of ultrasonic technology, we strongly recommend you contact us regarding application and availability before placing your order.
Ordering Information
Included in standard delivery: Converter, manual
FLRE2 Time Delta M-Flow fixed transit-time flow meter converter, AC power input $ 1,475
FLRE4 Time Delta M-Flow fixed transit-time flow meter converter, DC power input 1,475
Accessories
Each detector kit includes: Detector unit, 16 ft. signal cable, mounting straps, 3.5 oz tube sonic coupling compound
Description Pipe diameter range Temperature range
FLSE12 FLR type 1 sensor (2 MHz) 1.0 to 4.0 in -40 to 212°F $ 724
FLSE22 FLR type 2 sensor (2 MHz) 2.0 to 9.0 in -40 to 212°F 749
TKUSTTFLRC1 RS232C Communications 209
TKUSTTFLRC2 RS485 Communications 179
TKUSTTFLRC3 Synchronization 179
TKUSTTFLRC4 RS485 & synchronization 179
TKUSTTNIST Calibration, NIST traceable (5 pt.) 450
TKUSTTPTG FS-200 Ultrasonic thickness gauge 1,200
TKUSTTSG Sonic coupling compound 15
TKUSTTSGN Sonic coupling compound, silicone-free 35
TKUSTTPCSR Pipe tape measure 30
TKUSTTPLSS Line isolator/conditioner 359.95
TKUSTTRG58 Signal cable, 50 ohm (16 ft min) 2.50/ft.
Information subject to change without notice. Prices in USD. 4-12