Follett 25CI425WLI, 50CI425WLI, 25HI425ASIDP, 50HI425ASIDP Installation Manual

Symphony Plus™ 25 and 50 Series
25/50HI425A-SI Wall Mount
Ice-only Dispenser with
SensorSAFE Dispensing
25/50CI425A/W-LI Countertop Ice-only
Dispenser with Lever Dispensing
25/50CI425A/W-SI Countertop
Ice-only Dispenser with
SensorSAFE™ Dispensing
Ice and Water Dispensers
25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A
Installation Guide
Please visit https://www.follettice.com/technicaldocuments
for the Operation and Service manual for your unit.
Welcome to Follett
Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and outstanding after-the-sale support. To ensure that this equipment delivers that same degree of service, review this guide carefully before you begin your installation.
Should you have need technical help, please call our Technical Service group at (877) 612-5086 or (610) 252-7301.
Please have your model number, serial number and complete and detailed explanation of the problem when contacting Technical Service.
Getting Started
After uncrating and removing all packing material. Inspect the equipment for concealed shipping damage. All freight is to be inspected upon delivery. If visible signs of damage exist, please refuse delivery or sign your delivery receipt "damaged." Follett Customer Service must be notied within 48 hours. Wherever possible, please include detailed photos of the damage with the original packaging so that we may start the freight claim process.
801 Church Lane • Easton, PA 18040, USA Toll free (877) 612-5086 • +1 (610) 252-7301 www.follettice.com
Installation and Service Videos:
www.follettice.com/servicevideolibrary
01033679R07
CAUTION!
§ Do not tilt unit further than 30° off vertical during uncrating or installation.
§ Dispenser bin area contains mechanical, moving parts. Keep hands and arms clear of this area at all times. If access to this area is required, power to unit must be disconnected rst.
§ Follett recommends a Follett water lter system be installed in the ice machine inlet water line (standard capacity #00130229, high capacity #00978957, carbonless high capacity #01050442).
§ Prior to operation, clean the dispenser in accordance with instructions found in this manual.
§ Ice is slippery. Be sure counters and oors around dispenser are clean, dry and free of ice.
§ Do not block left side air intake or right side air exhaust.
Specications
Countertop
25CI425A/W
36"
(91.5 cm)
50CI425A/W
40"
(101.6 cm)
Wall mount
Front View
21" (53.4 cm) 24" (61 cm)
14.25"
(36.2 cm)
AIR INTAKE
AIR EXHAUST
Right Side View Rear View
3/8" FPT condenser inlet (water­cooled only)
3/8" FPT condenser outlet (water­cooled only)
3/4" FPT drain
10.5"
(26.7 cm)
23"
(58.5 cm)
NEMA 5-15
0.88 (23 mm)
3/4 MPT MALE
Front View Right Side View Rear View
21.5" (54.6 cm)
24.5" (62.2 cm)*
DRAIN
10.5"
(26.7 cm)
3/8" water inlet
2.63" (6.6 cm)
1.38" (3.5 cm)
2.56" (6.5 cm)
5.69" (14.4 cm)
7.69" (19.5 cm)
25HI425A/W
36.5"
(92.7 cm)
50HI425A/W
40.5"
(102.9 cm)
14.25"
(36.2 cm)
AIR INTAKE
* Includes 0.5" (13 mm) for bracket supplied with unit.
AIR EXHAUST
17"
(43.2 cm)
2 25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A
NEMA 5-15
21.5" (54.6 cm)
Electrical
§ 115 V, 60 Hz, 1 phase, 11.0A
§ Connect to a 15A dedicated circuit.
§ Furnished with 7 ft (2 m) power cord with a 90° NEMA hospital grade 5-15 plug.
Ambient
Air temp* 100 F/38 C Max. 50 F/10 C Min. (Best performance below 80 F (27 C)
Water temp
90 F/32 C Max. 45 F/7 C Min. (Best performance below 70 F (21 C)
Water pressure (psi/bar) 70/5 Max. 10/0.7 Min.
* Ambient air temperature is measured at the air-cooled condenser coil inlet.
Ambient water temperature is measured in the ice machine oat reservoir.
Plumbing
Connections 25/50CI425A Rough-ins 25/50HI425A
Dispenser drain 3/4" MPT Air-cooled 3/4" FPT
Water inlet 3/8" FPT 3/8" FPT
Condenser inlet Water-cooled 3/8" FPT N/A
Condenser outlet Water-cooled 3/8" FPT N/A
Note: Water shut-off recommended within 10 ft. (3m) of dispenser. Drain to be hard-piped and insulated. Maintain at least 1/4" per foot (20 mm per 1 m) run of slope.
Ventilation clearances
Air-cooled Water-cooled
Required for ventilation 3" (77 mm) each side N/A
Suggested for service 12" (30.5 cm) top,
6" (15.3 cm ) left side
Note: Do not block right side air intake or right side air exhaust.
12" (30.5 cm) top
Dry weight
§ 25/50CI425A/W (countertop): 215 lbs. (98 kg)
§ 25/50HI425A/W (wall mount): 230 lbs. (105 kg)
25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A 3
Refrigeration pressure data
Water-Cooled ice machine refrigeration pressure
Discharge pressure/suction pressure
Condenser Water Temperature F/C
F/C 50/10 70/21 90/32
50/10 280/27 285/29 290/31 psi
70/21 280/27 285/29 290/31 psi
90/32 280/27 285/29 290/31 psi
Inlet Water Temperature F/C
Compressor data
Compressor current draw
Air-cooled
Ambient air temp. 60 F/15.6 C 70 F/21.1 C 80 F/26.7 C 90 F/32.2 C 100 F/37.8 C
5.8A 6.1A 6.2A 6.2A 6.3A
High side pressure (psi) 190 220 250 290 330
Low side pressure (psi) 27 29 31 33 36
Locked rotor amps 58.8
Gearmotor data Split-Phase PSC (permanent split capacitor)
Gearmotor current 1.8A-1.9A (nominal) 0.8A-0.9A (nominal)
Locked rotor amps 14A 7A-14A (temperature dependent)
Refrigeration system
Important: All service on refrigeration system must be performed in accordance with all federal, state and local
laws that pertain to the use of refrigerants. It is the responsibility of the technician to ensure that these requirements are met.
Model Charge Refrigerant type
25/50CI425A, 25/50HI425A (air-cooled) 15 oz R404A
25/50CI425W (water-cooled) 9 oz R404A
4 25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A
Installation
Before you begin
§ All dispensers must be installed level in both directions to ensure proper operation.
§ Provide proper ventilation clearances.
§ Countertop units provide the option of taking utilities out bottom or back of dispenser (on wall mount units and countertop units with legs, utilities exit from back).
§ Wall mount model utilities exit through back of dispenser only.
§ Directions for each installation follow.
WARNING!
§ DO NOT LIFT UNIT AT THESE POINTS. Panels will not support weight of unit
§ Failure to follow warning may result in equipment damage or personal injury
Installing countertop dispensers with rear exiting utilities (no legs)
1. Position dispenser in desired location.
2. Mark dispenser outline on counter and
remove dispenser.
3. Drill four 7/16" holes in counter to anchor dispenser to counter (Fig. 1).
4. Apply a thick bead approximately 1/4" (7 mm) diameter of NSF listed silicone sealant (Dow Corning® RTV-732 or equivalent) 1/4" (7 mm) inside marked outline of dispenser.
5. Reposition dispenser on counter and secure to counter with four 3/8"-16NCbolts.
6. Smooth excess sealant around outside of dispenser.
7. Make utility connections (Fig. 2).
CAUTION!
§ Do not connect water-cooled condenser outlet line to the dispenser drain line.
8. Turn on water supply and check for leaks.
9. Clean dispenser and ice machine before
putting into service.
10. Turn power on and allow ice machine to produce ice.
Fig. 1 Countertop anchoring locations
1.56"
(40 mm)
4X
12.50"
(31.8 cm)
.50"
(13 mm)
Ø.375"
(10 mm)
hole
20" (50.8 cm)
Fig. 2 Utility connections as viewed from top for countertop back access
condenser outlet 3/8" FNPT
condenser inlet
3/8" FNPT
potable water
3/8" FNPT
drain 3/4" MPT
power
25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A 5