Fluke current clamps extend the current ranges of Fluke tools.
The Fluke i100 AC/DC Solar Current Clamp is highly reliable,
measures 1 A to 100 A and provides accurate current reading
without breaking the circuit. This clamp measures both ac and dc
current with a large jaw, battery-powered Hall-effect probe that
gives access to difficult to reach areas.
Safety
A
Warning identifies hazardous conditions and procedures that
are dangerous to the user. A Caution identifies conditions and
procedures that can cause damage to the Product or the
equipment under test.
XW Warning
To prevent possible electrical shock, fire, or personal
injury:
Do not alter the Product and use only as specified, or
the protection supplied by the Product can be
compromised.
Do not use the Product around explosive gas, vapor,
or in damp or wet environments.
Do not touch voltages >30 V ac rms, 42 V ac peak, or
60 V dc.
Do not use the Product if it operates incorrectly.
Do not use the Product if it is altered or damaged.
Comply with local and national safety codes. Use
personal protective equipment (approved rubber
gloves, face protection, and flame-resistant clothes)
to prevent shock and arc blast injury where hazardous
live conductors are exposed.
Before each use, examine the Product. Look for cracks
or missing pieces of the clamp housing or output cable
insulation. Also look for loose or weakened
components. Carefully examine the insulation around
the jaws.
Use the Clamp only on insulated conductors. Use
caution around bare conductors or bus bars. To
prevent electrical shock, do not touch the conductor.
Do not apply more than the rated voltage and rated
current on the jaws.
Do not use a current measurement as an indication
that a circuit is safe to touch. A voltage measurement
is necessary to know if a circuit is hazardous.
Hold the Product behind the tactile barrier.
Remove the input signals before you clean the
Product.
Repair the Product before use if the battery leaks.
Battery leakage may create a shock hazard or damage
the Product.
Batteries contain hazardous chemicals that can cause
burns or explode. If exposure to chemicals occurs,
clean with water and get medical aid.
Remove the batteries if the Product is not used for an
extended period of time, or if stored in temperatures
above 50 °C. If the batteries are not removed, battery
leakage may result.
The battery door must be closed and locked before
you operate the Product.
Be sure that the battery polarity is correct to prevent
battery leakage.
Use only specified replacement parts.
Have an approved technician repair the Product.
Symbols
The table below lists the symbols that can be used on the Product
or in this document.
SymbolDescription
»
W
X
-
M
PConforms to European Union directives.
~
Consult user documentation.
WARNING. RISK OF DANGER.
WARNING. HAZARDOUS VOLTAGE. Risk of electric
shock.
Do not apply current sensor to or remove from
HAZARDOUS LIVE UNINSULATED CONDUCTORS,
which may render electric shock, electric burn, or
arc flash.
Battery
This product complies with the WEEE Directive and
its marking requirements. The affixed label indicates
that you must not discard this electrical/electronic
product in domestic household waste. Do not
dispose of this product as unsorted municipal
waste. For information about take-back and
recycling programs available in your country, see
the website.
Instructions
To use the Clamp:
1. Connect the green plug to the green socket on the Analyzer.
2. Connect the yellow plug to the yellow socket on the Analyzer.
Clean with a soft towel moistened with water and mild detergent.
DO NOT IMMERSE in liquid.
Battery Replacement
For specified battery life, replace with alkaline batteries.
Product Disposal
Dispose of the Product in a professional and environmentally
appropriate manner. Remove batteries that are not integrated into
the electrical system before disposal and dispose of batteries
separately.
Specifications
Maximum voltage between any Terminal
and Earth Ground ......................1000 V
Operating Temperature............0 °C to 50 °C (14 °F to 122 °F)
Storage Temperature...............-30 °C to 60 °C (-22 °F to 140 °F)
Relative Humidity ......................<80 % RH, up to 40 °C (104 °F)
<40 % RH, up to 50 °C (122 °F)
Operating Altitude.....................2000 m
Storage Altitude......................... 12 000 m
Battery Type (x2)........................1.5 V AA (alkaline) IEC LR6
Battery Life .................................. 50 hr typical
Output Signal..............................10 mV/A dc or ac
Group 1: Equipment has intentionally generated and/or uses
conductively-coupled radio frequency energy that is
necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments
other than domestic and those directly connected to a low
voltage power supply network that supplies buildings used for
domestic purposes. There may be potential difficulties in
ensuring electromagnetic compatibility in other environments
due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential
environments and may not provide adequate protection to
radio reception in such environments.
Korea (KCC) ...........................Class A equipment (Industrial
Class A: Equipment meets requirements for industrial
electromagnetic wave equipment and the seller or user should
take notice of it. This equipment is intended for use in business
environments and not to be used in homes.
USA (FCC)...............................47 CFR 15 subpart B. This product is
up to 1 kHz
Crest Factor ≤3
(0 °C to 18 °C, 28 °C to 50 °C)
IEC 61010-2-032, Type D current
sensor (for use on insulated
conductors), 1000 V max
Electromagnetic Environment,
IEC 61326-2-2 CISPR 11: Group 1,
Class A
This Fluke product will be free from defects in material and
workmanship for 1 year from the date of purchase. This warranty
does not cover fuses, disposable batteries, or damage from
accident, neglect, misuse, alteration, contamination, or abnormal
conditions of operation or handling. Resellers are not authorized
to extend any other warranty on Fluke’s behalf. To obtain service
during the warranty period, contact your nearest Fluke authorized
service center to obtain return authorization information, then
send the product to that Service Center with a description of the
problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER
WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE,
ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY.
Since some states or countries do not allow the exclusion or
limitation of an implied warranty or of incidental or consequential
damages, this limitation of liability may not apply to you.