Fluke 417D Specifications

TECHNICAL DATA
Fluke 417D Laser Distance Measurer
The Fluke 417D is accurate, durable, and easy to use— just point and shoot.
The simple design and easy one-button operation means you can minimize your time measuring while maximizing the reliability of the measurements you need.
The extra bright laser is clearly visible, so you can always see your targeting point even if the target object is in a hard-to-reach spot, or at a long distance. The 417D has a large 2-line illumi­nated LCD screen and three-buttons for easy-to-use one-handed measurements.
The 417D additionally offers:
• 131 ft. working range
• One-touch controls
• 2-line illuminated display
• Ultra-portable
• 1-meter drop tested
• IP54 dust and water resistant
• 3-year warranty
FEATURES AND BENEFITS
All meters of fer:
• Measures up to 40 m (131 ft.) with accuracy of 2mm (0.08 in)
• Instant distance measurement with one­button operation
• Great for interior and exterior applications
• Improved visibility with backlit screen
• Easy targeting with bright laser
• Quick calculation of area (square footage)
• Continuous measurement capable
• Improved battery life from automatic shut-off feature
• Battery life of 3,000 measurements
General specifications
417D
Typical range [1] 0.2-40 m/0.6-131 ft
Typical measuring tolerance* [1] 2.0 mm ± 1.5 mm/± 0.06 in ***
Maximum measuring tolerance [2] ± 3.0 mm/0.12 in ***
Accuracy up to 10m (+/-) ± 2 mm
Display 2 line/1 mm/1/32 in
Display illumination Yes
Laser point at distance 6/30/60 mm (10/40/100 m)
Area Yes
Units setting (smallest units displayed) 0,000m, 0' 00'' 1/32, 0 in 1/32
Auto laser switch off 90 sec
Auto power switch off 180 sec
General
Laser class II
Laser type 635 nm, <1 mW
Protection class IP54 Battery life (2 x A AA) 1.5 V NEDA 24A/IEC
LR03 Size (Hx W x D) 11.9 x 3.8 x 2.6 cm
Drop test 1 meter
Weight (with batteries) 95g (3.35 oz)
Temperature range: Storage -25 °C to 70 °C (-13 °F to 158 °F)
Temperature range: Operation -10 °C to 50 °C (14 °F to 122 °F)
Calibration cycle Not applicable
Maximum relative humidity
Safety
CAN/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010 -1 (2nd Edition), ISA-
82.02.01, IEC Standard No. 61010-1:2001, EN60825-1:2007 (Class II)
EMC 61326 -1: 2006
Up to 3,000 measurements
85 % @ 20°F to 120 °F
(-7 °C to 50 °C)
[1] Applies for 100 % target reflectivity (white painted wall), low backg round
illumination, 25 °C (13 °F).
[2] Applies for 10 % to 500 % target reflectivity, high background illumination, -10 °C to
+50 °C (14 °F to +122 °F).
[3] Tolerances apply from 0.05 m to 10 m (0.001 ft to 32.8 ft) w ith a confidence level of
95 %. The maxi mum tolerance may deteriorate to 0.1 mm/m (0.003 in/ft) between 10 m to 30 m (32.8 ft to 98.4 ft) and to 0.15 mm/m (0.005 in/f t) for distances above 30 m (98.4 ft).
[4] Applies for 100 % target reflectiv ity, background illumination between 10,000 lux and
30,000 lux.
[5] After user calibration. Additional angle related deviation of ± 0.01° per degree up
to ± 45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maxi mum dev iation increases by ± 0.1°.
2 Fluke Corporation Fluke 417D Laser Distance Measurer
Fluke 417 D Laser Distance Meter