Fluke 37-720 User Manual

37-720
Dual-Diode Dosimeter Patient Dose Monitor
User Manual
Fluke Biomedical
6045 Cochran Road Cleveland, Ohio 44139
440.498.2564
www.flukebiomedical.com
Table of Contents
Section 1: General Information................................................................................... 1-1
1.1 Introduction.................................................................................................. 1-1
1.2 Specifications............................................................................................... 1-2
1.3 Accessories .................................................................................................1-3
Section 2: Operation.................................................................................................... 2-1
2.1 Battery Check.............................................................................................. 2-1
2.2 Zeroing the Instrument................................................................................. 2-1
2.3 Calibration.................................................................................................... 2-1
2.4 Making a Measurement ............................................................................... 2-2
Section 3: Maintenance............................................................................................... 3-1
3.1 Battery Replacement ................................................................................... 3-1
3.2 Diode Cleaning Instructions......................................................................... 3-1
i
(Blank page)
General Information
Introduction
1
Section 1
General Information
1.1 Introduction
System Description
The Dual-Diode Dosimeter Patient Dose Monitor combines a compact, battery operated, electrometer with a silicon diode detector. The detector can be placed anywhere external to the patient for dose verification and is easily held in position by taping to the skin.
The diode can be taped directly to the patient’s skin to obtain data for TLD readout values, eliminating TLD measurements. Irregular field dosimetry is easily performed with this system. No temperature pressure corrections need be applied to values obtained during the measurement process. The system allows accurate and reproducible dose and dose rate data to be obtained without the necessity of temperature equilibration or warm-up time.
Measurements can be read directly on the 3½-digit liquid crystal display (LCD) readout, eliminating complex calculations. The electrometer has two detector inputs on the rear panel labeled DET A and DET B. Each input has a range of 0 through 1999 cGy or cGy/min. A front panel switch enables the selection of the detector input being utilized. Each detector has a clearly marked, screwdriver adjustable set of calibration and zero controls mounted conveniently on the front panel. A quick response reset button, also on the front panel, sets the system up for the next reading.
Patient Dose Monitor Model 37-720 is designed specifically for use with the silicon diode detectors (positive output) recommended by Fluke Biomedical, Radiation Management Services (see Section 1.3). The electrometer must be calibrated for each individual detector and radiation source.
A special feature inherent in the 37-720 is the ability to switch between DET A and DET B, using the front panel switch, so that two detectors can be utilized for monitoring at the same time. This feature is applicable when the measurement is being taken in the dose or rate mode. Measurements can be taken in DOSE or RATE depending on the setting of the function switch. If it is desired to switch from one mode to another, the RESET switch can be pressed to zero the electrometer.
1-1