Fluke 374, 375, 376 Operating Manual

374/375/376
Clamp Meter
PN 3608883 July 2010
© 2010 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.
Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A.
11/99
Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands

Table of Contents

Title Page
Introduction................................................................................................................. 1
How to Contact Fluke ................................................................................................. 2
Safety Information ...................................................................................................... 3
The Meter ................................................................................................................... 9
Specifications ............................................................................................................. 19
Electrical Specifications.......................................................................................... 19
Mechanical Specifications ...................................................................................... 26
Environmental Specifications ................................................................................. 27
i
374, 375, 376
Users Manual
ii

Introduction

XWWarning
Read "Safety Information" before you use the Meter.
The Fluke 374, 375, and 376 (the Meter) measure true-rms ac current and voltage, dc current and voltage, inrush current, resistance, and capacitance. The 375 and 376 also measure frequency and dc millivolts. The detachable iFlex (Flexible Current Probe) that is included with the 376 (optional with the 374 and 375) expands the measurement range to 2500 A ac. The Flexible Current Probe provides increased display flexibility and allows measurements of awkward sized conductors and improved wire access. The illustrations in this manual show the 376.
1
374, 375, 376
Users Manual

How to Contact Fluke

To contact Fluke, call one of the following telephone numbers:
Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)
Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-3434-0181
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500
Or, visit Fluke's website at www.fluke.com
To register your product, visit http://register.fluke.com
To see, print, or download the latest manual supplement, visit
http://us.fluke.com/usen/support/manuals
2
.
.
.
Clamp Meters
Safety Information

Safety Information

A Warning identifies conditions and actions that pose hazard(s) to the user. A Caution identifies conditions and procedures that could cause Meter damage, equipment under test damage, or permanent loss of data.
Symbols used on the Meter and in this manual are explained in Table 1.
XWWarning
To prevent possible electrical shock or personal injury, follow these guidelines:
Use the Meter only as specified in this manual or the protection provided by the
Meter can be compromised.
Examine the case before you use the Meter. Look for cracks or missing plastic.
Carefully look at the insulation around the connectors.
Never measure current while the test leads are inserted into the input jacks.
Make sure the battery door is closed and latched before operating the Meter.
Remove the test leads from the Meter before the battery door is opened.
Examine the test leads for damaged insulation or exposed metal. Check test lead
continuity. Replace damaged test leads before using the Meter.
Do not use the Meter if it operates incorrectly. Protection can be compromised.
When in doubt, have the Meter serviced.
3
374, 375, 376
Users Manual
Do not use the Meter around explosive gas, vapor or in damp or wet
environments.
Use only type AA batteries, properly installed in the Meter case, to power the
Meter.
When measuring current with the Jaw, keep fingers behind the Tactile Barrier.
See "The Meter" .
To avoid false readings that can lead to electrical shock and injury, replace the
batteries as soon as the low battery indicator () appears.
When servicing the Meter, use only specified replacement parts.
Have the Meter serviced only by qualified service personnel.
Be careful around voltages > 30 V ac rms, 42 V ac peak, or 60 V dc. Such
voltages pose a shock hazard.
Do not apply more than the rated voltage, as marked on the Meter, between the
terminals or between any terminal and earth ground.
When using the probes, keep fingers behind the finger guards on the probes.
Connect the common test lead before connecting the live test lead. When
disconnecting test leads, disconnect the live test lead first.
Do not work alone so assistance can be rendered in an emergency.
Use extreme caution when working around bare conductors or bus bars. Contact
with the conductor could result in electric shock.
4
Clamp Meters
Safety Information
Adhere to local and national safety codes. Individual protective equipment must
be used to prevent shock and arc blast injury where hazardous live conductors are exposed.
Disconnect circuit power and discharge all high-voltage capacitors before you
measure resistance, continuity, or capacitance.
For the 374 and 375, do not measure ac/dc current in circuits carrying more than
1000 V or 600 A with the Meter Jaw.
For the 376, do not measure ac/dc current in circuits carrying more than 1000 V
or 1000 A with the Meter Jaw.
Never operate the Meter with the back cover removed or the case open.
Do not measure ac current in circuits carrying more than 1000 V or 2500 A with
the Flexible Current Probe.
Do not apply the Flexible Current Probe around or remove from HAZARDOUS
LIVE conductors.
Do not use the flexible current sensor if the inner contrasting insulation color is
showing.
Take special care during fitting and removal of the Flexible Current Probe. De-
energize the installation under test or wear suitable protective clothing.
5
374, 375, 376
Users Manual
WCaution
To avoid possible damage to the Meter or to equipment under test:
Use the proper jacks, function, and range for the measurement application.
Clean the case and accessories with a damp cloth and mild detergent only.
Do not use abrasives or solvents.
Table 1. Symbols
Symbol Meaning Symbol Meaning
B AC (Alternating Current)
F DC (Direct Current) ~
X Hazardous voltage P
6
J
Earth ground
Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information.
Conforms to European Union directives.
Clamp Meters
Safety Information
Symbol Meaning Symbol Meaning
W
®
-
Risk of Danger. Important information. See Manual.
Battery. Low battery when shown on display.
Examined and licensed by TÜV Product Services.
Do not apply to or remove from HAZARDOUS LIVE conductors.
)
T
;
,
Conforms to relevant North American Safety Standards.
Double insulated
Conforms to relevant Australian standards.
Application around and removal from HAZARDOUS LIVE conductors is permitted.
7
374, 375, 376
Users Manual
Symbol Meaning Symbol Meaning
IEC Measurement Category III CAT III equipment has protection
CAT III
8
against transients in equipment in fixed-equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings.
The Measurement Category (CAT) and voltage rating of any combination of test probe, test probe accessory, current clamp accessory, and the Meter is the LOWEST rating of any individual component.
CAT IV
Note
IEC Measurement Category IV CAT IV equipment has protection
against transients from the primary supply level, such as an electricity Meter or an overhead or underground utility service.
Clamp Meters
The Meter

The Meter

Clamp Meter
fig01.eps
9
374, 375, 376
Users Manual
Auto Power Off Backlight
20
ON
10
ON
fig02_3.eps
Clamp Meters
The Meter
Display Hold MIN MAX AVG
=
1x
=
2x
=
3x
2 sec = Exit
fig04_5.eps
11
374, 375, 376
Users Manual
Flexible Current Probe
1
12
2
<0.5 A
>0.5 A
3
fig06.eps
Clamp Meters
The Meter
Jaw
<0.5 A
>0.5 A
Hz
(375 & 376)
1
> 5 A
> 20 A
2
Fig07.eps
13
374, 375, 376
Users Manual
1
14
3
<0.5 A
2
Fig08.eps
Clamp Meters
The Meter
dc (375 & 376)
fig09_10.eps
15
374, 375, 376
Users Manual
16
e
e
R
R
ON
<30
Fig15.eps
Clamp Meters
The Meter
Off
On
3
100 ms
1
2
INRUSH
4
fig13_14.eps
17
374, 375, 376
Users Manual
1
3
2
18
fig11_12.eps
Clamp Meters
Specifications

Specifications

Electrical Specifications

AC Current via Jaw
Range
374 and 375 ......................................600.0 A
376.....................................................999.9 A
Resolution ............................................... 0.1 A
Accuracy .................................................2 % ± 5 digits (10-100 Hz)
2.5 % ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) ..........................3 @ 500 A (375 and 376 only)
2.5 @ 600 A
1.42 @1000 A (376 only) Add 2 % for C.F. > 2
19
374, 375, 376
Users Manual
AC Current via Flexible Current Probe
Range ....................................................2500 A
Resolution
374 and 375 ........................................0.1 A ( 600 A)
1 A ( 2500 A)
376 ......................................................0.1 A ( 999.9 A)
1 A ( 2500 A)
Accuracy .................................................3 % ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) ...........................3.0 at 1100 A (375 and 376 only)
2.5 at 1400 A
1.42 at 2500 A Add 2 % for C.F. > 2
20
Clamp Meters
Specifications
Position Sensitivity
A
B
C
ghn12.eps
Figure 1. Position Sensitivity
21
374, 375, 376
Users Manual
Distance from
Optimum
A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5 %
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0 %
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range
374 and 375 ......................................600.0 A
376.....................................................999.9 A
Resolution............................................... 0.1 A
Accuracy .................................................2 % ± 5 digits
AC Voltage
Range
22
i2500-10 Flex i2500-18 Flex Error
Clamp Meters
Specifications
374 and 375 ........................................600.0 V
376 ......................................................1000 V
Resolution
374 and 375 ........................................0.1 V
376 ......................................................0.1 V ( 600.0 V)
1 V ( 1000 V)
Accuracy .................................................1.5 % ± 5 digits (20 – 500 Hz)
DC Voltage
Range
374 and 375 ........................................600.0 V
376 ......................................................1000 V
23
374, 375, 376
Users Manual
Resolution
374 and 375 ........................................0.1 V
376 ......................................................0.1 V ( 600.0 V)
1 V ( 1000 V)
Accuracy .................................................1 % ± 5 digits
mV dc
Range
375 and 376.......................................500.0 mV
Resolution............................................... 0.1 mV
Accuracy .................................................1 % ± 5 digits
Frequency via Jaw
Range
375 and 376.......................................5.0 - 500.0 Hz
Resolution............................................... 0.1 Hz
Accuracy .................................................0.5 % ± 5 digits
24
Clamp Meters
Specifications
Trigger Level ........................................... 5 – 10 Hz, 10 A
10 – 100 Hz, 5 A 100 – 500 Hz, 10 A
Frequency via Flexible Current Probe
Range
375 and 376 ........................................5.0 – 500.0 Hz
Resolution ............................................... 0.1 Hz
Accuracy .................................................0.5 % ± 5 digits
Trigger Level ........................................... 5 – 20 Hz, 25 A
20 – 100 Hz, 20 A 100 – 500 Hz, 25 A
Resistance
Range
374.....................................................6000 Ω
375 and 376.......................................60 kΩ
25
374, 375, 376
Users Manual
Resolution
374.....................................................0.1 Ω ( 600 Ω)
1 Ω (≤ 6000 Ω)
375 and 376.......................................0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ)
Accuracy .................................................1 % ± 5 digits
Capacitance
Range .....................................................1000 μF
Resolution............................................... 0.1 μF ( 100 μF)
1 μ F (≤ 1000 μF)
Accuracy .................................................1 % ± 4 digits

Mechanical Specifications

Size (L x W x H) ..................................... 246 mm x 83 m x 43 mm
Weight..................................................... 388 g
Jaw Opening........................................... 34 mm
26
Clamp Meters
Specifications
Flexible Current Probe Diameter ............7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)...............1.8 m

Environmental Specifications

Operating Temperature........................... -10 °C – +50 °C
Storage Temp .........................................-40 °C – +60 °C
Operating Humidity .................................Non condensing (< 10 – °C)
90 % RH (at 10 °C – 30 °C) 75 % RH (at 30 °C – 40 °C) 45 % RH (at 40 °C – 50 °C)
Operating Altitude ...................................3000 meters
Storage Altitude ......................................12,000 meters
EMC ........................................................ EN 61326-1:2006
Temperature Coefficients........................Add 0.1 x specified accuracy for each degree C above
28 °C or below 18 °C
27
374, 375, 376
Users Manual
Safety Specifications
Safety Compliance.................................. CAN/CSA-C22.2 No. 61010-1-04
ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008
P
Agency Approvals...................................
Batteries.................................................. 2 AA, NEDA 15A, IEC LR6
28
), ;, ®
Loading...