Fluke 370 FC Specifications

Page 1
TECHNICAL DATA
Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters
The new Fluke 370 FC Series (376 FC, 375 FC and 374 FC) offers advanced troubleshooting performance. The iFlex® flex-
Log and trend measurements to pinpoint intermittent faults
Transmit results wirelessly via Fluke Connect
Create and send reports right from the field
Capture measurements outside the arc flash zone with Bluetooth
connectivity to your Apple or Android devices
Product highlights
Connect your meter to your smartphone using Fluke Connect
Measurements app to increase the troubleshooting power of your clamp
Read measurements on your phone at a safe distance, wearing
less PPE while your meter takes all the risks
Record results directly to your phone and the Fluke Cloud™
Capture intermittent faults while performing other tasks using
the logging capabilities of the Fluke 376 FC and 375 FC
Create and share reports from the field via email, or converse in
real time with ShareLive™ video calls
iFlex flexible current probe expands the measurement range to
2500 A ac; provides access to large conductors in tight spaces (included with 376 FC; compatible with 375 FC and 374 FC)
®
Measurements app
LOG AND TREND MEASUREMENTS
Transmit results wirelessly via Fluke Connect® Measurements app
WORK SAFELY
Capture measurements outside the arc flash zone with Bluetooth connectivity to your Apple or Android devices
LO-PASS FILTER
Integrated VFD low-pass filter (Fluke 376 FC and 375 FC) for accurate motor drive measurements
TRUE-RMS
True-rms voltage and current for accurate measurements on non-linear signals
WARRANTY
Three-year
All t radema rks are the property of their respective owner s
Page 2
TPAK magnetic hanging strap (included with 376 FC; compatible
with 375 FC and 374 FC) allows you to conveniently hang the meter while using the probes
Integrated VFD low pass filter (Fluke 376 FC and 375 FC) for
accurate motor drive measurements
Proprietary in-rush measurement technology to filter out
noise and capture motor starting current exactly as the circuit protection sees it
CAT IV 600 V, CAT III 1000 V safety rating
Three-year warranty
Soft carrying case
Measurement Capability
1000 A ac and dc current measurement (376 FC); 600 A
ac and dc (375 FC and 364 FC)
2500 A ac current measurement with iFlex
probe
®
flexible current
1000 V ac and dc voltage measurement
True-rms voltage and current for accurate measurements
on non-linear signals
Frequency measurement to 500 Hz with body jaw and iFlex
(376 FC and 375 FC)
Resistance measurement to 60 kΩ (376 FC and 375 FC)
or 6000 Ω (374 FC), with continuity detection
Min, max, average and in-rush recording to capture variations
automatically
500 mV dc measurement range to interface with other
accessories (376 FC and 375 FC)
1000 μF capacitance measurement
2 Fluke Corporation Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters
Page 3
Comparison chart
Fluke 376 FC Fluke 375 FC Fluke 374 FC
CAT rating CAT III 1000 V, CAT IV 600 V CAT III 1000 V, CAT IV 600 V CAT III 1000 V, CAT IV 600 V
A ac range 999.9 A with clamp jaws
A dc range 999.9 A 600 A 600A
Best resolution 0.1 A 0.1 A 0.1 A
V ac range 1000 V 1000 V 1000 V
V dc range 1000 V 1000 V 1000 V
mV dc range 500 mV 500 mV
Ohms range 60.00 kΩ 60.00 kΩ 6,000 Ω
Frequency 5-500.0 Hz 5-500.0 Hz
Capacitance 1 μF-1,000 μF 1 μF-1,000 μF 1 μ-1,000 μF
Auto shutoff
True RMS
Display hold
Inrush measurements
Backlight
DC zero
Min/max
VFD low pass filter
Logging
iFlex® flexible current clamp Included Optional Optional
Fluke Connect® compatible
2500 A with iFlex® flexible
current clamp
600 A with clamp jaws
2500 A with optional iFlex®
flexible current clamp
600 A with clamp jaws
2500 A with optional iFlex®
flexible current clamp
Specifications
General specifications
Maximum voltage between any terminal and earth ground 1000 V
Battery type 2 AA alkaline batteries, NEDA 15A, IEC LR6
Temperature Operating: -10 °C to +50 °C (14 °F to + 122 °F)
Operating humidity Non condensing (< 10 °C (50 °F)), ≤90 % RH (at 10 °C to 30 °C (50 °F to 86 °F)),
Altitude Operating: 3,000 m (9,842 ft)
Dimensions 24.9 cm (9.8 in) x 8.5 cm (3.3 in) x 4.5 cm (1.7 in)
Weight 395 g (13.9 oz)
Jaw opening 34 mm (1.3 in)
Flexible current probe diameter 7.5 mm (.29 in)
Flexible current probe cable length (head to electronics connector)
Safety IEC 61010-1, Pollution Degree 2
IP rating IEC 60529: IP30, non-operating
Radio frequency certification FCC ID:T68-FBLE IC:6627A-FBLE
Storage: -40 °C to +60 °C (-40 °F to + 140 °F)
≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F))
Storage: 12,000 m (39,370 ft)
1.8 m (70.8 in)
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
3 Fluke Corporation Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters
Page 4
General specifications continued
Electromagnetic Compatibility (EMC) International: IEC 61326-1: Portable, Electromagnetic Environment,
IEC 61326-2-2 CISPR 11: Group 1, Class A
Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficients Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C
Function Range Resolution Accuracy Crest factor Trigger level
AC current via jaw
374 FC and 375 FC:
600.0 A 376 FC: 999.9 A
0.1 A 2 % ±5 digits (10 Hz to 100 Hz)
3 at 500 A (375 FC and 376 FC only)
2.5 at 600 A
1.42 at 1000 A (376 FC only) Add 2 % for C.F. >2
AC current via flexible current probe
DC current 374 FC and 375 FC:
2500 A 374 FC and 375 FC:
0.1 A (≤ 600.0 A),
1 A (≤ 2500 A) 376 FC: 0.1 A (≤ 999.9 A), 1 A (≤ 2500 A)
0.1 A 2 % ±5 digits
3 % ±5 digits (5 Hz to 500 Hz)
3.0 at 1100 A (375 FC and 376 FC only)
2.5 at 1400 A
1.42 at 2500 A Add 2 % for C.F. >2
600.0 A 376 FC: 999.9 A
AC voltage 1000 V 0.1 V (≤600.0 V)
1 V (≤1000 V)
DC voltage 1000 V 0.1 V (≤600.0 V)
1.5 % ±5 digits (20 Hz to 500 Hz)
1 % ±5 digits
1 V (≤1000 V)
mV dc 500.0 mV 0.1 mV 1 % ±5 digits
Frequency via jaw
375 FC and 376 FC:
5.0 Hz to 500.0 Hz
0.1 Hz 0.5 % ±5 digits 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A 100 Hz to 500 Hz, ≥10 A
Frequency via flexible current probe
Resistance 374 FC: 6,000 Ω
375 FC and 376 FC:
5.0 Hz to 500.0 Hz
375 FC and 376 FC: 60 kΩ
0.1 Hz 0.5 % ±5 digits 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A
374 FC: 0.1 Ω (≤600 Ω),
1 % ±5 digits
1 Ω (≤6000 Ω) 375 FC and 376 FC: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 10 Ω (≤60 kΩ)
Capacitance 1000 μF 0.1 μF (≤100 μF),
1 % ±4 digits
1 μ F (≤1000 μF)
4 Fluke Corporation Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters
Page 5
Ordering information
374 FC 600A AC/DC True-rms Wireless Clamp Meter 375 FC 600A AC/DC True-rms Wireless Clamp Meter 376 FC 1000A AC/DC True-rms Wireless Clamp Meter with iFlex
Included
18-inch iFlex® Flexible Current Probe (376 FC only) TPA K Magnetic Hanging Strap (376 FC only) Soft Carrying Case TL75 Test Leads Two AA Alkaline Batteries Coated Instruction Card Safety Information Sheet
Optional accessories
TPA K Magnetic Hanging Strap (included with 376 FC) 18-inch iFlex® Flexible Current Probe (included with 376 FC)
®
Set up and sustain preventive maintenance practices with ease to help you oversee your complex world with the Fluke Connect® system of software and wireless test tools.
Maximize uptime and make confident maintenance decisions with data you can trust and trace.
Save measurements to the Fluke Cloud™ and associate with an asset so your team can consult both historical and current measurements from one location.
Collaborate with ease by sharing your data with others with ShareLive™ video calls and emails.
Wireless one-step measurement transfer with AutoRecord™ measurements removes the need for clipboards and paper work.
Consult summary views of all assets over time for easy identification of correlated or periodic failures for easier prioritization of maintenance work.
Generate reports with multiple measurement types to provide status or work recommendations.
Find out more at flukeconnect.com
Download the app at:
Smar tphone is not included with purchase.
Fluke. Keeping your world up and running.
Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2015 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 8/2015 6005995a-en
Modification of this document is not permitted without written permission from Fluke Corporation.
®
5 Fluke Corporation Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters