Technical Data
Accurate peak measurements
can be taken using the in-rush
current mode, ideal for motors
and inductive loads. The 355 also
measures voltage and resistance,
making this the most versatile tool
for utilities, electrical contractors,
and industrial service technicians.
Reliably handle a wide range of high-current
•
applications with 2000 A ac + dc true-rms,
1400 A ac, and 2000 A dc
The large 58 mm (2.3 in) jaw capacity is suitable for
•
large, or multiple conductors
CAT IV 600 V, CAT III 1000 V rating for added user
•
protection
In-rush current measurement captures ‘power-on’
•
surge current with accuracy and repeatability
High voltage measurement of 1000 V ac + dc
•
true-rms, 600 V ac, and 1000 V dc allows users to
perform multiple tests with only one tool (355 only)
Resistance to 400 kW coupled with a continuity
•
beeper, provide the convenience of a multimeter
(355 only)
Accurately measure frequency up to 1 kHz for
•
optimum troubleshooting
Quickly analyze readings using the MIN, MAX, and
•
AVG functions
A large backlit display allows for easy visibility in
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz
600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.
RangeResolutionAccuracyTrigger Level for Hz
Filter OFF
4 V1 mV1 % rdg + 10 digits0.050 V0.050 V
40 V10 mV1 % rdg + 5 digits0.25 V0.25 V
400 V100 mV1 % rdg + 5 digits6 V6 V
600 V ac rms1 V1 % rdg + 5 digits6 V6 V
1000 V dc1 V1 % rdg + 5 digitsN/AN/A
Trigger Level for Hz
Filter ON
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz
600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.
RangeResolutionAccuracyTrigger Level for Hz
Filter OFF
4 V1 mV3 % rdg + 10 digits0.050 V0.050 V
40 V10 mV3 % rdg + 5 digits0.25 V0.25 V
400 V100 mV3 % rdg + 5 digits6 V6 V
600 V ac rms1 V3 % rdg + 5 digits6 V6 V
Trigger Level for Hz
Filter ON
Ohms measurement (355 only)
RangeResolutionAccuracy
400 W0.1 W
4 kW1 W
40 kW10 W
400 kW100 W
1.5 % + 5 digits
1.5 % + 5 digits
1.5 % + 5 digits
1.5 % + 5 digits
2 Fluke Corporation Fluke 355/353 True-rms 2000 A Clamp Meters
Page 3
Continuity beeper (355 only)
On at ≤ 30 W
Off at ≥ 100 W
Frequency measurement
Measurement range5.0 Hz to 1 kHz
Resolution0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz0.2 % + 2 counts
Accuracy – 100.1 Hz to 1 kHz0.5 % + 5 counts
Trigger levelRefer to current and voltage tables
General specifications
BatteriesSix 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off)100 hours
Test leadsRated to 1000 V
Weight.814 kg (1.8 lb)
Jaw size58 mm (2.28 in)
Dimensions (LxWxD)300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
Safety ratingIEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
Environmental specifications
Operating temperature32 °F to + 122 °F (0 °C to +50 °C)
Storage temperature-4 °F to 140 °F (-20 °C to +60 °C)
Operating humidity0 to 95 % (non-condensing)
Operating altitude2000 m
Storage altitude10,000 m
IP rating42 (indoor use only)
Drop test requirements1 m
EMI, RFI, EMCFCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN
Temperature coefficientsCurrent: 0.1 % of reading per °C outside 22 °C to 24 °C
61326:1997 3V/m, performance criteria B, EN61325
Voltage: 0.1 % of reading per °C outside 22 °C to 24 °C
Ordering information:
Fluke-353 AC/DC True-rms Clamp Meter, 2000 A, Amps only
Includes: C43 Soft Carrying Case, 6 AA batteries, and users manual
Fluke-355 AC/DC True-rms Clamp Meter, 2000 A
Includes: C43 Soft Carrying Case, 6 AA batteries, TL224 1.5 m
Silicone Rubber Test Leads, TP2 Test Probes, AC285 Alligator Clips,
and users manual
3 Fluke Corporation Fluke 355/353 True-rms 2000 A Clamp Meters
Fluke. Keeping your world
up and running.
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800) 36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com