Fluke 190-062, 190-102, 190-104, 190-202, 190-204 Brochure

BUILT TOUGH
to keep up with you.
BUILT TOUGH
to keep up with you.
Over 20 years of ScopeMeter®
High performance handheld scopesHigh performance handheld scopes
Test Tool Innovation
190 Series II ScopeMeter® Portable Oscilloscopes
New
500 MHz
4 Ch
See more. Fix more.
®
ScopeMeter
portable oscilloscopes take you into territories where standard bench scopes can’t go: where it’s harsh, hazardous and dirty—without sacrificing any capabilities.
Compare waveforms and easily perform timing and amplitude measurements of 4 channels simultaneously.
500 MHz bandwidth and 5GS/s sampling can reveal signal noise and distortion that otherwise may go undetected.
5GS/s sampling or 200 ps sample resolution provides the detail needed to inspect signal edge dV/dt or signs of destructive
22
reflections.
The Fluke 190 Series II ScopeMeter® oscilloscopes, with electrically isolated channels, are safety rated for indus­trial applications. These scopes combine rugged portability with the high performance of bench oscilloscopes to take you from troubleshooting microelectronics all the way into power electronic applications—from dc to 500 MHz.
Choose from two or four channel models with a wide
range of bandwidth options. Fast sampling rates up to
5.0GS/s, 200 ps resolution and deep memory of 10,000 samples per channel allow high-accuracy capture and dis­play of waveform details, noise, and other disturbances.
Perform timing or amplitude related measurements on three phases or three-axis control systems, or simply compare and contrast multiple test points in a circuit under test. Features like TrendPlot
and-View automation and process controls, and power electronics to minimize repair costs and downtime. These features make the oscilloscopes easy to use especially when diagnosing the most difficult problems like complex waveforms, induced noise, intermittent events and signal fluctuations or drift.
New Li-Ion battery technology keeps your scope on the job, all day.
Fluke 190 Series II ScopeMeter with two or four channels, 60MHz to 500 MHz. Choose the model that’s right for your application and budget.
help you quickly diagnose industrial machinery,
, ScopeRecord™, and Connect-
®
test tools are available
Built to with­stand harsh environments with the highest safety ratings
Rated all the way to CAT IV
ScopeMeter® test tools are rugged solutions built for industrial troubleshoot­ing. The new Fluke 190 Series II are double-insulated floating oscilloscopes safety rated for measurements in CATIII 1000V / CAT IV 600V environments.
Measure from mV to kV safely
Independent isolated inputs allow you to make measurements in mixed circuits having different ground references reduc­ing the risk of accidental short circuits.
Conventional bench oscilloscopes with­out special differential probes and isolation transformers can only reference measure­ments to line power earth ground.
With standard probes that cover a wide application range from mV to kV, you’re ready for anything from microelectronics to heavy-duty higher voltage electrical appli­cations.
IP-51 rated for harsh environments
Rugged and shock-proof, ScopeMeter® portable oscilloscopes are built for dirty, hazardous environments. With its sealed case, it can endure and airborne pollutants. Every time you reach for ScopeMeter scope you can be confident it will work reliably wherever your work takes you.
dust, drips, humidity
®
portable oscillo-
Overvoltage category In brief Examples
CAT IV Three-phase at
utility connection, any outdoor conductors
CAT III Three-phase
distribution, including single­phase commercial lighting
CAT II Single-phase
receptacle connected loads
CAT I Electronic
Refers to the “origin of installation,” that
is, where low-voltage connection is made to utility power
Electricity meters, primary overcurrent
protection equipment
Outside and service entrance, service
drop from pole to building, run between meter and panel
Overhead line to detached building,
underground line to well pump
Equipment in fixed installations, such as
switchgear and polyphase motors
Bus and feeder in industrial plants
Feeders and short branch circuits,
distribution panel devices
Lighting systems in larger buildings
Appliance outlets with short connections
to service entrance
Appliance, portable tools, and other
household and similar loads
Outlet and long branch circuits
Outlets at more than 10 meters (30 feet)
from CAT III source
Outlets at more that 20 meters (60 feet)
from CAT IV source
Protected electronic equipment
Equipment connected to (source) circuits
in which measures are taken to limit transient over voltages to an appropriately low level
Any high-voltage, low-energy source
derived from a high-winding resistance transformer, such as the high-voltage section of a copier
Tab le 1. Overvoltage installation categories. IEC 61010 applies to low-voltage (< 1000 V) test eq uipment.
33