Fluke 16 Specifications Sheet

Fluke 16 Multimeter
With Thermometer
It’s a thermometer
The Fluke 16 measures temperature quickly and accurately. Standard equipment includes an 80PK-1 bead probe thermocouple and an 80AK temperature adapter, which is com­patible with a wide range of type K thermocouples with mini­connectors.
It’s a flame rod circuit tester
A microamp function is included for flame sensor measurements down to 0.1 microamps.
It’s a multimeter with capacitance
Use the Fluke test motor start and run capacitors up to 10,000 microfarads. Rely on the Fluke 16 to make your everyday measurements - up to 600 volts ac or dc, 40 megohms, diode test and exceptionally fast continuity.
• Accurate temperature measurement from -40
ο
(-40
to 400οC)
• Confidently test flame sensor circuits with microamp measure­ment down to 0.1 microamps
• Capacitance up to 10,000 microfarads
• Min/Max recording with relative time stamp records the highest and lowest voltage readings during a 100-hour period
• Auto-ranging
• High resistance ranges to 40 M
• Millivolt range for compatibility with other accessories
• V-Check™ mode is designed for safety. When measuring ohms, continuity, or diode test modes, the meter automatically switches to measuring ac or dc volts if more than 4.5V is present
ο
to 750οF
• Continuity Capture™ locates intermittent opens as brief as 250 microseconds and identifies them in a symbolic display as short­to-open or open-to-short
• Sleep mode preserves battery life
• 4000 count digital display
• Meter includes: 80PK-1 Bead Tem­perature Probe, 80AK Temperature Adapter, TL75 Test Leads, and C10 Holster
Safety
600V ac/dc, maximum voltage between any terminal and earth ground. Conforms to the requirements of IEC-1010-1, 1990-09 and ANSI/ISA-S82.01-94 for use in Overvoltage Category III locations. Make ac or dc voltage measurements on electrical distribution systems to 600V where transients do not exceed 6 kV and only on circuits limited to 14 kVA if the circuit voltage rating is above 250V. Certification agencies (approvals/listings pending):
UL Per standard UL 3111 CSA Per standard CSA/CAN
C22.2 No.1010.1-92
TÜV Per standard EN61010
Part 1-1993
Drop test
ANSI/ISA-S82.01-94 and EN61010 Part1-1993. 10 ft. drop to hardwood on concrete
Size
(HxWxL) 1.12 in x 2.95 in x 6.55 in, (2.8 cm x 7.5 cm x 16.6 cm)
Battery life
650 hours with Alkaline
Weight
12 oz (340g)
Warranty
Three years
Specifications
Function Range Resolution Accuracy DC Volts
AC Volts
Current ac/dc Ohms
Capacitance
Temperature
4000 mV
4.000V 0.001V 0.9% + 2
40.00V 0.01V 0.9% + 1
400.0V 0.1V 0.9% + 1 600V 1V 0.9% + 1 4000 mV
4.000V 0.001V 1.9% + 3
40.00V 0.01V 1.9% + 3
400.0V 0.1V 1.9% + 3 600V 1V 1.9% + 3 200 µA 0.1 µA
400.0 0.1
4.000 k 0.001 k
40.00 k 0.01 k
400.0 k 0.1 k
4.000 M 0.001 M
40.00 M 0.01 M
1.000 µF 0.001 µF 1.9% + 2
10.00 µF 0.01 µF 1.9% + 2
100.0 µF 00.1 µF 1.9% + 2 1000 µF 001 µF 1.9% + 2 10,000 µF 0010 µF 10% + 90 typical 15 to 750° F 0.1° F 1% + 1.5° F typical
- 40 to 15° F 0.1° F 5% + 2.7° F
-10 to 400° C 0.1° C 1% + .8° C typical
-40 to -10° C 0.1° C 5% + 1.5° C
1
1
1 mV 0.9% + 2
1 mV 1.9% + 3
0.5% + 2
0.9% + 2
0.9% + 1
0.9% + 1
0.9% + 1
0.9% + 1
1.5% + 3
Accessories and Ordering Information
Included Accessories
80PK-1 Bead Temperature Probe 80AK Temperature Adapter TL75 Test Leads C10 Holster
Ordering Information
Fluke 16 Multimeter with Temperature
Need Technical Assistance? Call:
1-800-44-FLUKE
Toll-free in the U.S. (905) 890-7600 in Canada (425) 356-5500 other countries
2
2
2
2
2
3
3
3
3
For more information to be sent to you by fax, call 1-800-FLUKE-FAX in the U.S. and Canada, or visit our Website at http://www.fluke.com
1
The 4000 mV range can only be entered in manual range mode.
use the 4000 mV range with accessories.
2
The accuracy specification is for capacitors that have negligible dielectric absorption. Capacitance measured with rc charge technique that evaluates C = Q/V. Capacitors with non-negligible dielectric absorption can be measured, but measurement values may be in error.
3
The accuracy specification for temperature do not include the error caused by the thermocouple.
Fluke.