Fisher Paykel RGV2366LN Planning guide

36" PROFESSIONAL
RANGES & BACKGUARDS
RGV2-364GD, RGV2-366, RDV2-364GD, RDV2-366
BGRV2-1236, BGRV2-3036, BGRV2-3036H models
PLANNING GUIDE
CONTENTS
36" Professional Range RGV2-364GD, RGV2-366 , RDV2-364GD, RDV2-366
Key Design Decisions 5 17
Ventilation Requirements 6 18
36" Professional Range RGV2-364GD, RDV2-364GD
Product & Cavity Dimensions 7 19
Clearance Dimensions 8 20
Cavity Preparation 9 21
36" Professional Range RGV2-366, RDV2-366
Product & Cavity Dimensions 10 22
Clearance Dimensions 11 23
PAGE
in mm
Cavity Preparation 12 24
CONTENTS (continued)
36" Professional Range Backguard BGRV2-1236
Product Dimensions
36" Professional Range Backguard BGRV2-3036
Product Dimensions 14 26
36" Professional Range Backguard BGRV2-3036H
Product Dimensions 15 27
PAGE
in mm
IMPERIAL
KEY DESIGN DECISIONS
6" Professional Range
1
INSTALL TYPE
WALL
2
REAR SURFACE
COMBUSTIBLE
3
BACKGUARD OPTIONS
CLEARANCE
NO BACKGUARD
MIN 6"
Model no:
RGV2-364GD, RGV2-366
RDV2-364GD, RDV2-366
BGRV2-1236
LOW THIN BACKGUARD
CUSTOM
BACKGUARD*
MIN 30"
BGRV2-3036H
ANGLED TRIM (Supplied with
backguard)
HIGH THICK BACKGUARD
WITH ANGLED TRIM
BGRV2-3036
ISLAND
NON COMBUSTIBLE
NO BACKGUARD
MAX 1/2"
CUSTOM FABRICATED* BACKGUARD
*Fabricated from non combustible materials only
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
HIGH THIN BACKGUARD
VENTILATION REQUIREMENTS
Wall Installation
2'' Deep x Unit Width
600–1200 CFM
Island Installation
0'' Deep x Unit Width
600–1200 CFM
6" Professional Range
1
INSTALL TYPE
WALL
HOOD SURROUND MATERIAL
23"
MAX 36"
NON COMBUSTIBLE
30"
MIN 30"
2
23"
COMBUSTIBLE
30"
MIN 36"
Model no:
RGV2-364GD, RGV2-366
RDV2-364GD, RDV2-366
Specifications
Ventilation Unit
Hood
Blower
Ventilation Unit
Hood
Blower
Note: A suitable hood must be installed above the range. The above indicates the minimum blower capacity recommended for hood ventilation.
ISLAND
MIN 30"
MAX 36"
NON COMBUSTIBLE
COMBUSTIBLE
MIN 36"
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
B
in
min 5 /4''
max 6 /4''
5 7/8''
29 1/8''
25 1/8''
27 11/16''
1 9/16''
1 /4''
7 /4''
8 1/16''
9 7/16''
28 7/8''
5 1/4''
1 1/4''
5 9/16''
 1/16''
19 1/8''
min 1/2''
max 1 1/2''
in
min 5 /4''
max 6 /4''
min 6''
max
25 1/8''
max
27 11/16''
35 7/8''
PRODUCT & CAVITY DIMENSIONS
6" Professional Range
Model no:
RGV2-364GD-N, RGV2-364GD-L
RDV2-364GD-N, RDV2-364GD-L
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
DATUM :
TOP OF COUNTERTOP
K J I H
C
29 1/8''
p
n
PLAN VIEW
C
29 1/8''
F
G
Product Dimensions
A Overall height of range (from floor to cooktop,
excludinggrates and vent trim)
B Overall width of range
C Overall depth of range (excluding handle and dials)
D Depth from rear of chassis to cabinetry face - projecting
E Depth from rear of chassis to cabinetry face - flush
F Height from countertop to top of pan supports
G Height from countertop to top of vent trim
H Height from countertop to bottom of control panel
I Height from countertop to top of door
J Height from countertop to center of handle
K Height from countertop to bottom of door
L Height from countertop to bottom of chassis
M Thickness of handle (not including standoffs)
N Width of handle (including standoffs)
O Depth of handle (measured from front of door)
P Depth of open door to cabinetry face - flush
Q Adjustable feet height
m
l
o
5 /4'' ­6 /4''
A
Cavity Dimensions
Overall height of cavity
Overall width of cavity
Overall depth of cavity for projecting control panel
Overall depth of cavity for flush control panel
DATUM : BOTTOM OF CHASSIS
0 5 10 20
inches
B
Q
5 7/8''
Dp
E
FRONT VIEW PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
INDICATES PRODUCT DATUM -------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
in
6''
18''
12''
54'' 0''
1''
6" Professional Range
MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
DATUM :
TOP OF COUNTERTOP
PLAN VIEW
MINIMUM CLEARANCE:
CC
NEAREST VERTICAL COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
D
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
E
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
D
NON-COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
B
ADJACENT OVERHEAD CABINET
Model no:
RGV2-364GD-N, RGV2-364GD-L
RDV2-364GD-N, RDV2-364GD-L
Clearance Dimensions
A Minimum width of ventilation hood installed above range
- not shown*
B Minimum vertical distance between countertop and cabinet
extending above counter
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
D Minimum clearance from cooking surface to:
– combustible surface centered above the cooking surface – non-combustible surface centered above the cooking surface
E Maximum overall depth of overhead cabinetry
DATUM : BOTTOM OF CHASSIS
0 5 10 20
inches
FRONT VIEW PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES PRODUCT DATUM -------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
in
2''
1 1/2''
19''
12''
5''
1 1/2''
6''
RGV Models
120 VAC, 60Hz
8 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
21 amp
0 amp circuit
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
6" Professional Range
RGV models
c d
RDV models
e b
FINAL POSITION OF RANGE AGAINST WALL
ELECTRICAL
GAS
FINAL POSITION OF RANGE AGAINST WALL
Model no:
RGV2-364GD-N, RGV2-364GD-L
RDV2-364GD-N, RDV2-364GD-L
Location of Electrical and Gas Supply
A Depth of supply area (ie maximum protrusion of
gasconnection from wall)
B Distance from right hand edge of range to supply area
C (RGV) Height of electrical supply area (from floor)
D (RGV) Height of gas supply area (from floor)
E (RGV) Width of supply area
F (RDV) Distance from left hand edge of range to supply area
G (RDV) Height of electrical and gas supply area (from floor)
a
Specifications
Electrical
Supply
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
Service
Gas – Natural
Connection
Supply Pressure
Gas – LP
Connection
Supply Pressure*
g
f b
0 5 10 20
inches
ELECTRICAL & GAS
A regulator is required at the LP source to provide a maximum pressure of 14” W.C. to the range regulator.
a
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
B
in
min 5 /4''
max 6 /4''
5 7/8''
29 1/8''
25 1/8''
27 11/16''
1 9/16''
1 /4''
7 /4''
8 1/16''
9 7/16''
28 7/8''
5 1/4''
1 1/4''
5 9/16''
 1/16''
19 1/8''
min 1/2''
max 1 1/2''
in
min 5 /4''
max 6 /4''
min 6''
max
25 1/8''
max
27 11/16''
35 7/8''
PRODUCT & CAVITY DIMENSIONS
6" Professional Range
Model no:
RGV2-366-N, RGV2-366-L
RDV2-366-N, RDV2-366-L
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
DATUM :
TOP OF COUNTERTOP
K J I H
C
29 1/8''
p
n
PLAN VIEW
C
29 1/8''
F
G
Product Dimensions
A Overall height of range (from floor to cooktop,
excludinggrates and vent trim)
B Overall width of range
C Overall depth of range (excluding handle and dials)
D Depth from rear of chassis to cabinetry face - projecting
E Depth from rear of chassis to cabinetry face - flush
F Height from countertop to top of pan supports
G Height from countertop to top of vent trim
H Height from countertop to bottom of control panel
I Height from countertop to top of door
J Height from countertop to center of handle
K Height from countertop to bottom of door
L Height from countertop to bottom of chassis
M Thickness of handle (not including standoffs)
N Width of handle (including standoffs)
O Depth of handle (measured from front of door)
P Depth of open door to cabinetry face - flush
Q Adjustable feet height
m
l
o
35 3/4'' ­36 3/4''
A
Cavity Dimensions
Overall height of cavity
Overall width of cavity
Overall depth of cavity for projecting control panel
Overall depth of cavity for flush control panel
DATUM : BOTTOM OF CHASSIS
0 5 10 20
inches
B
q
35 7/8''
Dp
E
FRONT VIEW PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
INDICATES PRODUCT DATUM -------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
in
6''
18''
12''
54'' 0''
1''
6" Professional Range
MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
DATUM :
TOP OF COUNTERTOP
PLAN VIEW
MINIMUM CLEARANCE:
CC
NEAREST VERTICAL COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
D
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
E
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
D
NON-COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
B
ADJACENT OVERHEAD CABINET
Model no:
RGV2-366-N, RGV2-366-L
RDV2-366-N, RDV2-366-L
Clearance Dimensions
A Minimum width of ventilation hood installed above range
- not shown*
B Minimum vertical distance between countertop and cabinet
extending above counter
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
D Minimum clearance from cooking surface to:
– combustible surface centered above the cooking surface – non-combustible surface centered above the cooking surface
E Maximum overall depth of overhead cabinetry
DATUM : BOTTOM OF CHASSIS
0 5 10 20
inches
FRONT VIEW PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES PRODUCT DATUM -------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
in
2''
1 1/2''
19''
12''
5''
1 1/2''
6''
RGV Models
120 VAC, 60Hz
5 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
18 amp
0 amp circuit
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
RGV models
c d
RDV models
e b
FINAL POSITION OF RANGE AGAINST WALL
ELECTRICAL
GAS
CAVITY PREPARATION 6" Professional Range
Model no:
RGV2-366-N, RGV2-366-L
RDV2-366-N, RDV2-366-L
Location of Electrical and Gas Supply
A Depth of supply area (ie maximum protrusion of
gasconnection from wall)
B Distance from right hand edge of range to supply area
C (RGV) Height of electrical supply area (from floor)
D (RGV) Height of gas supply area (from floor)
E (RGV) Width of supply area
F (RDV) Distance from left hand edge of range to supply area
G (RDV) Height of electrical and gas supply area (from floor)
a
Specifications
Electrical
Supply
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
Service
g
f b
0 5 10 20
inches
FINAL POSITION OF RANGE AGAINST WALL
ELECTRICAL & GAS
Gas – Natural
Connection
Supply Pressure
Gas – LP
Connection
Supply Pressure*
A regulator is required at the LP source to provide a maximum pressure of 14” W.C. to the range regulator.
a
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
PRODUCT DIMENSIONS
in
10 /8''
15 15/16''
5 7/8''
''
5 9/16''
''
BGRV2-1236NOT TO SCALE
Model no:
BGRV2-1236
Product Dimensions
A Height of backguard above vent trim on range
B Overall height of backguard
C Overall width of backguard
D Overall depth of backguard
E Height of backguard below vent trim on range
F Depth of backguard below vent trim on range
DATUM : BACK OF PRODUCT
c
5 7/8''
6" Professional Range Backguard
1/2
1/16
DATUM : TOP OF VENT TRIM ON RANGE
RGV2-366/ RDV2-366 (illustrated)
DATUM : BACK OF PRODUCT
1/2''
d
f
PROFILE VIEW
A
10 /8''
e
PLAN VIEW
5 7/8''
c
FRONT VIEW
b
INDICATES PRODUCT DATUM -------------------------------------------
0 5 10 20
inches
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
5 7/8"
in
28 /8"
29 1/8"
5 7/8"
9 5/16"
1/2"
8 1/16"
4"
10 15/16"
17 /8"
5 7/8"
1/16"
1/16"
BGRV2-3036NOT TO SCALE
c
PRODUCT DIMENSIONS
6" Professional Range Backguard
DATUM : BACK OF PRODUCT
e
1/2"
j
RGV2-366/ RDV2-366 (illustrated)
DATUM : BACK OF PRODUCT
d
g
PLAN VIEW
5 7/8"
c
f
Model no:
BGRV2-3036
Product Dimensions
A Height of backguard above vent trim on range
B Overall height of backguard
C Overall width of backguard
D Overall depth of backguard and racks
E Depth of backguard
F Depth of racks
G Width of racks
H Distance from top of backguard to bottom of racks
I Distance from bottom of backguard to bottom of racks
J Distance from top of backguard to top of brackets
K Height of backguard below vent trim on range
L Depth of backguard below vent trim on range
h
AB
28 /8"
PROFILE VIEW
l
0 5 10 20
i
DATUM : TOP OF VENT TRIM ON RANGE
inches
FRONT VIEW
INDICATES PRODUCT DATUM -------------------------------------------
k
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
in
0''
5 7/8''
10 /8''
26 1/2''
 1/2''
2 7/8''
1 5/16'''
9 1/16''
 15/16"
5 /8''
18 7/8''
5 7/8"
BGRV2-3036HNOT TO SCALE
B
6" Professional Range Backguard with Angled Vent Trim
PRODUCT DIMENSIONS
DATUM : BACK OF BACKGUARD
1 5/16"
g
RGV2-366/ RDV2-366 (illustrated)
DATUM : BACK OF BACKGUARD
Model no:
BGRV2-3036H
f
c
h
i
PLAN VIEW
5 7/8"
B
Product Dimensions
A Overall height of backguard with angled vent trim
B Overall width of backguard
C Overall depth of backguard and racks
D Height of backguard
E Height of angled vent trim
F Depth of angled vent trim
G Depth of backguard
H Depth of racks
I Width of racks
J Distance from top of backguard to top of racks
K Distance from bottom of angled vent trim to bottom of racks
Note: Angled vent trim supplied with BGRV2-06H. Remove flat vent trim and replace with angled vent trim.
j
A
0"
d
k
PROFILE VIEW
f
0 5 10 20
DATUM : BOTTOM OF ANGLED VENT TRIM
inches
FRONT VIEW
e
INDICATES PRODUCT DATUM -------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
METRIC
KEY DESIGN DECISIONS
6" Professional Range
1
INSTALL TYPE
WALL
2
REAR SURFACE
COMBUSTIBLE
3
BACKGUARD OPTIONS
MIN 152mm
CLEARANCE
NO BACKGUARD
Model no:
RGV2-364GD, RGV2-366
RDV2-364GD, RDV2-366
BGRV2-1236
LOW THIN BACKGUARD
CUSTOM
BACKGUARD*
MIN 762mm
BGRV2-3036H
ANGLED TRIM (Supplied with
backguard)
HIGH THICK BACKGUARD
WITH ANGLED TRIM
BGRV2-3036
ISLAND
NON COMBUSTIBLE
NO BACKGUARD
MAX 24mm
CUSTOM FABRICATED* BACKGUARD
*Fabricated from non combustible materials only
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
HIGH THIN BACKGUARD
VENTILATION REQUIREMENTS
Wall Installation
584mm Deep x Unit Width
600–1200 CFM
Island Installation
762mm Deep x Unit Width
600–1200 CFM
6" Professional Range
1
INSTALL TYPE
WALL
HOOD SURROUND MATERIAL
584mm
MIN 762mm MAX 914mm
NON COMBUSTIBLE
762mm
2
584mm
COMBUSTIBLE
762mm
914mm
Model no:
RGV2-364GD, RGV2-366
RDV2-364GD, RDV2-366
Specifications
Ventilation Unit
Hood
Blower
Ventilation Unit
Hood
Blower
Note: A suitable hood must be installed above the range. The above indicates the minimum blower capacity recommended for hood ventilation.
ISLAND
MIN 762mm MAX 914mm
NON COMBUSTIBLE
COMBUSTIBLE
914mm
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
PRODUCT & CAVITY DIMENSIONS
mm
min 908 max 9
911
740
68
70
40
45
196
204
240
74
895
2
904
77
486
min 1
max 8
mm
min 908
max 9
min 914
max 68 max 70
911
B
Model no:
RGV2-364GD-N, RGV2-364GD-L
RDV2-364GD-N, RDV2-364GD-L
6" Professional Range
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
DATUM :
TOP OF COUNTERTOP
K J I H
C
740
p
n
PLAN VIEW
740
C
F
G
Product Dimensions
A Overall height of range (from floor to cooktop,
excludinggrates and vent trim)
B Overall width of range
C Overall depth of range (excluding handle and dials)
D Depth from rear of chassis to cabinetry face - projecting
E Depth from rear of chassis to cabinetry face - flush
F Height from countertop to top of pan supports
G Height from countertop to top of vent trim
H Height from countertop to bottom of control panel
I Height from countertop to top of door
J Height from countertop to centre of handle
K Height from countertop to bottom of door
L Height from countertop to bottom of chassis
M Thickness of handle (not including standoffs)
N Width of handle (including standoffs)
O Depth of handle (measured from front of door)
P Depth of open door to cabinetry face - flush
Q Adjustable feet height
m
l
o
908 ­933
A
Cavity Dimensions
Overall height of cavity
Overall width of cavity
Overall depth of cavity for projecting control panel Overall depth of cavity for flush control panel
DATUM : BOTTOM OF CHASSIS
0 100 200 400
millimetres
q
B
911
Dp
E
FRONT VIEW PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
INDICATES PRODUCT DATUM -------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
mm
914
457
05
172
762
0
6" Professional Range
MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
DATUM :
TOP OF COUNTERTOP
PLAN VIEW
MINIMUM CLEARANCE:
CC
NEAREST VERTICAL COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
D
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
E
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
D
NON-COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
B
ADJACENT OVERHEAD CABINET
Model no:
RGV2-364GD-N, RGV2-364GD-L
RDV2-364GD-N, RDV2-364GD-L
Clearance Dimensions
A Minimum width of ventilation hood installed above range
- not shown*
B Minimum vertical distance between countertop and cabinet
extending above counter
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
D Minimum clearance from cooking surface to:
– combustible surface centred above the cooking surface – non-combustible surface centred above the cooking surface
E Maximum overall depth of overhead cabinetry
DATUM : BOTTOM OF CHASSIS
0 100 200 400
millimetres
FRONT VIEW PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES PRODUCT DATUM -------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
mm
51
8
48
05
127
8
152
RGV Models
120 VAC, 60Hz
8 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
21 amp
0 amp circuit
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
6" Professional Range
RGV models
c d
RDV models
e b
FINAL POSITION OF RANGE AGAINST WALL
ELECTRICAL
GAS
FINAL POSITION OF RANGE AGAINST WALL
Model no:
RGV2-364GD-N, RGV2-364GD-L
RDV2-364GD-N, RDV2-364GD-L
Location of Electrical and Gas Supply
A Depth of supply area (ie maximum protrusion of
gasconnection from wall)
B Distance from right hand edge of range to supply area
C (RGV) Height of electrical supply area (from floor)
D (RGV) Height of gas supply area (from floor)
E (RGV) Width of supply area
F (RDV) Distance from left hand edge of range to supply area
G (RDV) Height of electrical and gas supply area (from floor)
a
Specifications
Electrical
Supply
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
Service
Gas – Natural
Connection
Supply Pressure
Gas – LP
Connection
Supply Pressure*
g
f b
0 100 200 400
millimetres
ELECTRICAL & GAS
A regulator is required at the LP source to provide a maximum pressure of 14” W.C. to the range regulator.
a
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
PRODUCT & CAVITY DIMENSIONS
mm
min 908 max 9
911
740
68
70
40
45
196
204
240
74
895
2
904
77
486
min 1
max 8
mm
min 908
max 9
min 914
max 68 max 70
911
B
Model no:
RGV2-366-N, RGV2-366-L
RDV2-366-N, RDV2-366-L
6" Professional Range
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
DATUM :
TOP OF COUNTERTOP
K J I H
C
740
p
n
PLAN VIEW
740
C
F
G
Product Dimensions
A Overall height of range (from floor to cooktop,
excludinggrates and vent trim)
B Overall width of range
C Overall depth of range (excluding handle and dials)
D Depth from rear of chassis to cabinetry face - projecting
E Depth from rear of chassis to cabinetry face - flush
F Height from countertop to top of pan supports
G Height from countertop to top of vent trim
H Height from countertop to bottom of control panel
I Height from countertop to top of door
J Height from countertop to centre of handle
K Height from countertop to bottom of door
L Height from countertop to bottom of chassis
M Thickness of handle (not including standoffs)
N Width of handle (including standoffs)
O Depth of handle (measured from front of door)
P Depth of open door to cabinetry face - flush
Q Adjustable feet height
m
l
o
908 ­933
A
Cavity Dimensions
Overall height of cavity
Overall width of cavity
Overall depth of cavity for projecting control panel Overall depth of cavity for flush control panel
DATUM : BOTTOM OF CHASSIS
0 100 200 400
millimetres
q
B
911
Dp
E
FRONT VIEW PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
INDICATES PRODUCT DATUM -------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
CLEARANCE DIMENSIONS
mm
914
457
05
172
762
0
6" Professional Range
MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL
DATUM :
TOP OF COUNTERTOP
PLAN VIEW
MINIMUM CLEARANCE:
CC
NEAREST VERTICAL COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
D
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
E
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
D
NON-COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
B
ADJACENT OVERHEAD CABINET
Model no:
RGV2-366-N, RGV2-366-L
RDV2-366-N, RDV2-366-L
Clearance Dimensions
A Minimum width of ventilation hood installed above range
- not shown*
B Minimum vertical distance between countertop and cabinet
extending above counter
C Minimum clearance from left and right edge of range to
nearest vertical combustible surface
D Minimum clearance from cooking surface to:
– combustible surface centred above the cooking surface – non-combustible surface centred above the cooking surface
E Maximum overall depth of overhead cabinetry
DATUM : BOTTOM OF CHASSIS
0 100 200 400
millimetres
FRONT VIEW PROFILE VIEW
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES PRODUCT DATUM -------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
mm
51
8
48
05
127
8
152
RGV Models
120 VAC, 60Hz
5 amp
15 amp circuit
RDV Models
120/240 VAC, 60Hz
18 amp
0 amp circuit
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure: 6” to 9” W.C.
1/2” NPT Minimum 5/8” dia. flex line
11” to 14” W.C.
RGV models
c d
RDV models
e b
FINAL POSITION OF RANGE AGAINST WALL
ELECTRICAL
GAS
CAVITY PREPARATION 6" Professional Range
Model no:
RGV2-366-N, RGV2-366-L
RDV2-366-N, RDV2-366-L
Location of Electrical and Gas Supply
A Depth of supply area (ie maximum protrusion of
gasconnection from wall)
B Distance from right hand edge of range to supply area
C (RGV) Height of electrical supply area (from floor)
D (RGV) Height of gas supply area (from floor)
E (RGV) Width of supply area
F (RDV) Distance from left hand edge of range to supply area
G (RDV) Height of electrical and gas supply area (from floor)
a
Specifications
Electrical
Supply
Max. Current Draw
Service
Electrical
Supply
Max. Current Draw
Service
g
f b
0 100 200 400
millimetres
FINAL POSITION OF RANGE AGAINST WALL
ELECTRICAL & GAS
Gas – Natural
Connection
Supply Pressure
Gas – LP
Connection
Supply Pressure*
A regulator is required at the LP source to provide a maximum pressure of 14” W.C. to the range regulator.
a
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
PRODUCT DIMENSIONS
mm
26
405
911
1
142
1
BGRV2-1236NOT TO SCALE
Model no:
BGRV2-1236
Product Dimensions
A Height of backguard above vent trim on range
B Overall height of backguard
C Overall width of backguard
D Overall depth of backguard
E Height of backguard below vent trim on range
F Depth of backguard below vent trim on range
DATUM : BACK OF PRODUCT
911
c
6" Professional Range Backguard
DATUM : TOP OF VENT TRIM ON RANGE
RGV2-366/ RDV2-366 (illustrated)
DATUM : BACK OF PRODUCT
1
d
f
PROFILE VIEW
26
PLAN VIEW
911
c
A
b
e
FRONT VIEW
INDICATES PRODUCT DATUM -------------------------------------------
0 100 200 400
millimetres
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
912
mm
720
740
911
27
1
224
864
278
442
149
20
1
BGRV2-3036NOT TO SCALE
c
PRODUCT DIMENSIONS
6" Professional Range Backguard
DATUM : BACK OF PRODUCT
e
1
j
RGV2-366/ RDV2-366 (illustrated)
DATUM : BACK OF PRODUCT
d
g
PLAN VIEW
912
c
f
Model no:
BGRV2-3036
Product Dimensions
A Height of backguard above vent trim on range
B Overall height of backguard
C Overall width of backguard
D Overall depth of backguard and racks
E Depth of backguard
F Depth of racks
G Width of racks
H Distance from top of backguard to bottom of racks
I Distance from bottom of backguard to bottom of racks
J Distance from top of backguard to top of brackets
K Height of backguard below vent trim on range
L Depth of backguard below vent trim on range
h
AB
720
PROFILE VIEW
0 100 200 400
l
i
DATUM : TOP OF VENT TRIM ON RANGE
millimetres
FRONT VIEW
INDICATES PRODUCT DATUM -------------------------------------------
k
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
912
mm
76
911
264
67
90
72

20
862
16
480
BGRV2-3036HNOT TO SCALE
B
6" Professional Range Backguard with Angled Vent Trim
PRODUCT DIMENSIONS
DATUM : BACK OF BACKGUARD

g
RGV2-366/ RDV2-366 (illustrated)
DATUM : BACK OF BACKGUARD
Model no:
BGRV2-3036H
f
c
h
i
PLAN VIEW
912
B
Product Dimensions
A Overall height of backguard with angled vent trim
B Overall width of backguard
C Overall depth of backguard and racks
D Height of backguard
E Height of angled vent trim
F Depth of angled vent trim
G Depth of backguard
H Depth of racks
I Width of racks
J Distance from top of backguard to top of racks
K Distance from bottom of angled vent trim to bottom of racks
Note: Angled vent trim supplied with BGRV2-06H. Remove flat vent trim and replace with angled vent trim.
j
A
76
d
f
0 100 200 400
k
DATUM : BOTTOM OF ANGLED VENT TRIM
PROFILE VIEW
millimetres
FRONT VIEW
e
INDICATES PRODUCT DATUM -------------------------------------------
DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com
IMPORTANT: The product dimensions and specifications
applyat the date of issue. Under our policy of continuous
product improvement, these dimensions and specifications
may change at any time. Dimensions may vary by ±2mm (1/16").
Please read the installation guide for detailed information
oninstalling the product or visit fisherpaykel.com.
April 2018
Loading...