INSTALLATION INSTRUCTIONS
Built-in Oven
OB60SL models
NZ AU GB IE
590477A 02.13
1
SAFETY AND WARNINGS
2
WARNING!
Electrical shock hazard
Before carrying out any work on the
electrical section of the appliance, it must
be disconnected from the mains electricity
supply.
Connection to a good earth wiring system
is absolutely essential and
mandatory.
Alterations to the domestic wiring
system must only be made by a qualified
electrician.
Failure to follow this advice may result in
electrical shock or death.
WARNING!
Fire hazard
Do not use adapters, reducers, or
branching devices to connect this
appliance to the mains power supply.
Failure to follow this advice may result in
overheating, burning, or fire.
WARNING!
IMPORTANT SAFETY INSTRUCTIONS!
To avoid hazard, follow these instructions carefully
before installing or using this appliance.
Please make this information available to the person
installing the appliance - doing so could reduce your
installation costs.
This appliance must be installed and connected to
the mains power supply only by a suitably qualified
person according to these installation instructions
and in compliance with any applicable local building
and electricity regulations. Failure to install the
appliance correctly could invalidate any warranty or
liability claims.
If the power supply cable is damaged, it must be
replaced by the manufacturer, its service agent or
similarly qualified person in order to avoid a hazard.
Isolating switch: make sure this oven is connected
to a circuit which incorporates an isolating switch
providing full disconnection from the power supply
in accordance with the wiring rules.
The oven must be earthed.
Do not use adaptors, reducers or branching devices
to connect the oven to the mains electricity supply,
as they can cause overheating and burning.
Cut hazard
Take care - some panel edges are sharp.
Failure to use caution could result in injury
or cuts.
2
PRIOR TO INSTALLATION
the benchtop and oven cavity are square and level, and are the required dimensions.
the installation will comply with all clearance requirements and applicable standards and regulations.
a suitable isolating switch providing full disconnection from the mains power supply is incorporated in the permanent wiring, mounted and positioned to comply with the local wiring rules and regulations. The
isolating switch must be of an approved type and provide a 3 mm air gap contact separation in all poles (or in all active [phase] conductors if the local wiring rules allow for this variation of the requirements).
the isolating switch will be easily accessible to the customer with the oven installed.
there is at least 1.5 m (and not more than 2 m) free length of power supply cable within the cavity for ease of installation and servicing.
the oven connection socket (if fitted) is outside the cavity if the oven is flush to the rear wall.
the oven will rest on a surface that can support its weight.
the height from the floor suits the customer.
you consult local building authorities and by-laws if in doubt regarding installation.
Important!
Some environmental factors and cooking habits can cause condensation in and around the oven during use. To protect surrounding cabinetry from possible damage caused by frequent or excessive condensation, we recommend
moisture-proofing the oven cavity.
3
AFTER INSTALLATION
Important!
Please take extra care not to damage the lower trim of the oven during installation. The trim is important for correct air circulation and allows the door to open and close without obstruction. The manufacturer does not accept any
responsibility for damage resulting from incorrect installation.
3
the oven door can open fully without obstruction.
the power supply cable does not touch any hot metal parts.
the isolating switch is easily accessible to the customer with the oven installed.
you complete the ‘Final checklist’ at the end of the installation.
If, after following the instructions given, correct performance cannot be achieved, please contact your nearest Fisher & Paykel Authorised Service Centre, Customer Care, or contact us through our local website listed at
the end of this document.
4
PARTS SUPPLIED
Screws (2)