Fisher & Paykel 847200 PERFORMANCE DATA SHEET

p
PERFORMANCE DATA SHEET
Refrigerator Water Filter Model: 847200
System certified by IAPMO R&T against NSF/ANSI Standards 42, 53, 401 and CSA B483.1 for the reduction of claims specified on the performance data sheet and at iapmort.org.
Actual performance may vary with local water conditions.
Substance Tested for Reduction
Chlorine Taste and Odor 2.0 mg/L +/- N/A >99 Chloramine Taste and Odor 3.0 mg/L +/-
Particulate, Class I At least Cysts 50,000/L N/A >99.99 Lead 0.15 0.01 98.85 Mercury 0.006 0.002 96.95 Asbestos 107 to 108 VOC (Chloroform surrogate
chemical)
Alachlor 0.050 0.001 > 98 Atrazine 0.100 0.003 > 97 Benzene 0.081 0.001 > 99 Carbofuran 0.190 0.001 > 99 carbon tetrachloride 0.078 0.0018 98 chlorobenzene 0.077 0.001 > 99 chloropicrin 0.015 0.0002 99 2,4-D 0.110 0.0017 98 dibromochloropropane 0.052 0.00002 > 99 o-Dichlorobenzene 0.08 0.001 > 99 p-Dichlorobenzene 0.040 0.001 > 98 1,2-dichloroethane 0.088 0.0048 95 1,1-dichloroethylene 0.083 0.001 > 99 cis-1,2-dichloroethylene 0.170 0.0005 > 99 trans-1,2-dichloroethylene 0.086 0.001 > 99 1,2-dichloropropane 0.080 0.001 > 99 cis-1,3-dichloropropylene 0.079 0.001 > 99 dinoseb 0.170 0.0002 99 Endrin 0.053 0.00059 99 Ethylbenzene 0.088 0.001 > 99 ethylene dibromide (EDB) 0.044 0.00002 > 99 bromochloroacetonitrile 0.022 0.0005 98 dibromoacetonitrile 0.024 0.0006 98 dichloroacetonitrile 0.0096 0.0002 98 trichloroacetonitrile 0.015 0.0003 98 1,1-dichloro-2-propanone 0.0072 0.0001 99 1,1,1-trichloro-2-propanone 0.0082 0.0003 96 heptachlor (H-34, Heptox) 0.025 0.00001 >99 heptachlor epoxide 0.0107 0.0002 98 hexachlorobutadiene 0.044 0.001 > 98 hexachlorocyclopentadiene 0.060 0.000002 > 99 Lindane 0.055 0.00001 > 99 methoxychlor 0.050 0.0001 > 99 pentachlorophenol 0.096 0.001 > 99 simazine 0.120 0.004 > 97 Styrene 0.150 0.0005 > 99 1,1,2,2-tetrachloroethane 0.081 0.001 > 99 Tetrachloroethylene 0.081 0.001 > 99 Toluene 0.078 0.001 > 99 2,4,5-TP (silvex) 0.270 0.0016 99 tribromoacetic acid 0.042 0.001 > 98 1,2,4-Trichlorobenzene 0.160 0.0005 > 99 1,1,1-trichloroethane 0.084 0.0046 95 1,1,2-trichloroethane 0.150 0.0005 > 99 trichloroethylene 0.180 0.0010 > 99 bromoform 0.300 0.015 95 bromodichloromethane 0.300 0.015 95 chlorodibromomethane 0.300 0.015 95 xylenes 0.070 0.001 >99 Meprobamate 400 +/- 20% 60 >99 Atenolol 200 +/- 20% 30 >99 Carbamazepine 1400 +/- 20% 200 >99 DEET 1400 +/- 20% 200 >99 Metolachlor 1400 +/- 20% 200 >99 Trimethoprim 140 +/- 20% 20 >99 Linuron 140 +/- 20% 20 >99 TCEP 5000 +/- 20% 700 >99 TCPP 5000 +/- 20% 700 >99 Phenytoin 200 +/- 20% 30 >99 Ibuprofen 400 +/- 20% 60 >99 Naproxen 140 +/- 20% 20 >99 Estrone 140 +/- 20% 20 >99 Bisphenol A 2000 +/- 20% 300 >99 Nonyl phenol 1400 +/- 20% 200 >99
Influent challenge concentration (mg/L)
10%
0.300
Maximum permissible product water concentration (mg/L)
0.5 >99
N/A 91.4
N/A >99
0.015
Avg % Reduction
>99
Application Guidelines/Water Supply Parameters
Service Flow 0.5 gpm (1.89 lpm)
Water Supply Potable Water
Water Pressure 25-120 psi (172-827 kPa)
Water Temperature 33°F-100°F (0.6°C-38°C)
Capacity 102 gallons (386 liters)
It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
Note: While the testing was performed under standard laboratory conditions, actual performance may vary.
Replacement Cartridge: 847200. For estimated costs of replacement parts contact spare parts team on 0800 287 746 or visit our website at fisherpaykel.com.
To reduce the risk associated with
ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before and after the system. Systems certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
NOTICE
To reduce the risk of water leakage or flooding, and to ensure optimal filter performance:
Read and follow use instructions before installation and use of this system.
Installation and use MUST comply with all state and local plumbing codes.
Do not install if water pressure exceeds 120 psi (827 kPa).
If your water pressure exceeds 80 psi, you must install a pressure-limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.
Do not install where water hammer conditions may occur. If water hammer conditions exist, you must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.
Do not install on hot water supply lines. The maximum operating water temperature of this filter system is 100º F (38º C).
Protect filter from freezing. Drain filter when temperatures drop below 33ºF (0.6ºC).
Change the disposable filter cartridge every six months or sooner if you observe a noticeable reduction in water flow rate.
Failure to replace the disposable filter cartridge at recommended intervals may lead to reduced filter performance and cracks in the filter housing, causing water leakage or flooding.
This System has been tested according to NSF/ANSI 42, 53 and 401 for the reduction of the substances listed below. The concentration of the indicated substances in water entering this system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53 and 401.
Certified by: IAPMO R&T against NSF/ANSI Standards 42, 53, 401 and CSA B483.1 for the reduction of claims specified on the
erformance data sheet and at iapmort.org.
847387