PERFORMANCE DATA SHEET
Refrigerator Water Filter Model: 847200
System certified by IAPMO R&T against NSF/ANSI Standards 42, 53, 401 and CSA B483.1 for the reduction of claims specified on the
performance data sheet and at iapmort.org.
Actual performance may vary with local water conditions.
Substance Tested for
Reduction
Chlorine Taste and Odor 2.0 mg/L +/- N/A >99
Chloramine Taste and Odor 3.0 mg/L +/-
Particulate, Class I At least
Cysts 50,000/L N/A >99.99
Lead 0.15 0.01 98.85
Mercury 0.006 0.002 96.95
Asbestos 107 to 108
VOC (Chloroform surrogate
chemical)
Alachlor 0.050 0.001 > 98
Atrazine 0.100 0.003 > 97
Benzene 0.081 0.001 > 99
Carbofuran 0.190 0.001 > 99
carbon tetrachloride 0.078 0.0018 98
chlorobenzene 0.077 0.001 > 99
chloropicrin 0.015 0.0002 99
2,4-D 0.110 0.0017 98
dibromochloropropane 0.052 0.00002 > 99
o-Dichlorobenzene 0.08 0.001 > 99
p-Dichlorobenzene 0.040 0.001 > 98
1,2-dichloroethane 0.088 0.0048 95
1,1-dichloroethylene 0.083 0.001 > 99
cis-1,2-dichloroethylene 0.170 0.0005 > 99
trans-1,2-dichloroethylene 0.086 0.001 > 99
1,2-dichloropropane 0.080 0.001 > 99
cis-1,3-dichloropropylene 0.079 0.001 > 99
dinoseb 0.170 0.0002 99
Endrin 0.053 0.00059 99
Ethylbenzene 0.088 0.001 > 99
ethylene dibromide (EDB) 0.044 0.00002 > 99
bromochloroacetonitrile 0.022 0.0005 98
dibromoacetonitrile 0.024 0.0006 98
dichloroacetonitrile 0.0096 0.0002 98
trichloroacetonitrile 0.015 0.0003 98
1,1-dichloro-2-propanone 0.0072 0.0001 99
1,1,1-trichloro-2-propanone 0.0082 0.0003 96
heptachlor (H-34, Heptox) 0.025 0.00001 >99
heptachlor epoxide 0.0107 0.0002 98
hexachlorobutadiene 0.044 0.001 > 98
hexachlorocyclopentadiene 0.060 0.000002 > 99
Lindane 0.055 0.00001 > 99
methoxychlor 0.050 0.0001 > 99
pentachlorophenol 0.096 0.001 > 99
simazine 0.120 0.004 > 97
Styrene 0.150 0.0005 > 99
1,1,2,2-tetrachloroethane 0.081 0.001 > 99
Tetrachloroethylene 0.081 0.001 > 99
Toluene 0.078 0.001 > 99
2,4,5-TP (silvex) 0.270 0.0016 99
tribromoacetic acid 0.042 0.001 > 98
1,2,4-Trichlorobenzene 0.160 0.0005 > 99
1,1,1-trichloroethane 0.084 0.0046 95
1,1,2-trichloroethane 0.150 0.0005 > 99
trichloroethylene 0.180 0.0010 > 99
bromoform 0.300 0.015 95
bromodichloromethane 0.300 0.015 95
chlorodibromomethane 0.300 0.015 95
xylenes 0.070 0.001 >99
Meprobamate 400 +/- 20% 60 >99
Atenolol 200 +/- 20% 30 >99
Carbamazepine 1400 +/- 20% 200 >99
DEET 1400 +/- 20% 200 >99
Metolachlor 1400 +/- 20% 200 >99
Trimethoprim 140 +/- 20% 20 >99
Linuron 140 +/- 20% 20 >99
TCEP 5000 +/- 20% 700 >99
TCPP 5000 +/- 20% 700 >99
Phenytoin 200 +/- 20% 30 >99
Ibuprofen 400 +/- 20% 60 >99
Naproxen 140 +/- 20% 20 >99
Estrone 140 +/- 20% 20 >99
Bisphenol A 2000 +/- 20% 300 >99
Nonyl phenol 1400 +/- 20% 200 >99
Influent
challenge
concentration
(mg/L)
10%
0.300
Maximum
permissible
product water
concentration
(mg/L)
0.5 >99
N/A 91.4
N/A >99
0.015
Avg %
Reduction
>99
Application Guidelines/Water Supply Parameters
Service Flow 0.5 gpm (1.89 lpm)
Water Supply Potable Water
Water Pressure 25-120 psi (172-827 kPa)
Water Temperature 33°F-100°F (0.6°C-38°C)
Capacity 102 gallons (386 liters)
It is essential that the manufacturer’s recommended installation,
maintenance and filter replacement requirements be carried out
for the product to perform as advertised.
Note: While the testing was performed under standard laboratory
conditions, actual performance may vary.
Replacement Cartridge: 847200. For estimated costs of
replacement parts contact spare parts team on 0800 287 746 or
visit our website at fisherpaykel.com.
To reduce the risk associated with
ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before and after
the system. Systems certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
NOTICE
To reduce the risk of water leakage or flooding, and to ensure
optimal filter performance:
Read and follow use instructions before installation and use of
this system.
Installation and use MUST comply with all state and local
plumbing codes.
Do not install if water pressure exceeds 120 psi (827 kPa).
If your water pressure exceeds 80 psi, you must install a
pressure-limiting valve. Contact a plumbing professional if you
are uncertain how to check your water pressure.
Do not install where water hammer conditions may occur. If
water hammer conditions exist, you must install a water hammer
arrester. Contact a plumbing professional if you are uncertain
how to check for this condition.
Do not install on hot water supply lines. The maximum operating
water temperature of this filter system is 100º F (38º C).
Protect filter from freezing. Drain filter when temperatures drop
below 33ºF (0.6ºC).
Change the disposable filter cartridge every six months or sooner
if you observe a noticeable reduction in water flow rate.
Failure to replace the disposable filter cartridge at recommended
intervals may lead to reduced filter performance and cracks in
the filter housing, causing water leakage or flooding.
This System has been tested according to NSF/ANSI 42, 53 and
401 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering this
system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in
NSF/ANSI 42, 53 and 401.
Certified by: IAPMO R&T against NSF/ANSI
Standards 42, 53, 401 and CSA B483.1 for the
reduction of claims specified on the
erformance data sheet and at iapmort.org.
847387