Installation Instructions
D300912X012
March 2021
Design A, E, EH, HP, YD, & YS
ENVIRO-SEAL
™
Duplex Packing
Design A, E, EH, HP, YD, and YS ENVIRO-SEAL
Duplex Packing
Use these instructions to install ENVIRO‐SEAL packing
in valves that have standard packing or when
inspecting or replacing ENVIRO‐SEAL packing. For
additional information, see Fisher™ ENVIRO‐SEAL
Packing Systems for Sliding-Stem Valves Instruction
Manual (D101642X012
).
WARNING
Avoid personal injury or property damage from sudden
release of process pressure or uncontrolled movement
of parts. Before performing any maintenance
operations:
Disconnect any operating lines providing air pressure,
electric power, or a control signal to the actuator. Be
sure the actuator cannot suddenly open or close the
valve.
Use bypass valves or completely shut off the process to
isolate the valve from process pressure. Relieve process
pressure from both sides of the valve. Drain the process
media from both sides of the valve.
Vent the pneumatic actuator loading pressure and
relieve any actuator spring precompression. If a
spring-return actuator is used, be sure the actuator is
resting on its travel stop before disconnecting the stem
connector.
Use lock‐out procedures to be sure that the above
measures stay in effect while you work on the
equipment.
If you are installing the system in a valve that is still
connected to an actuator, remove the actuator from
the valve to provide sufficient space to install the
packing assembly. Refer to the appropriate valve and
actuator instruction manuals to remove the actuator.
1. Carefully remove the old packing parts from the
packing box. The surface condition of the valve
stem and the packing box wall is critical in obtaining
a good seal. If the valve stem needs to be replaced,
or any other valve part, refer to the appropriate
valve instruction manual for replacement
procedures. Complete all valve maintenance before
installing the ENVIRO‐SEAL packing system into the
bonnet.
2. The original studs used for standard packing
arrangements should be long enough to
accommodate the retrofit kit parts. If you
determine that the existing studs and nuts should
be replaced however, due to their condition,
replace them with the studs and nuts (keys 200 and
212) supplied in the retrofit kit.
Note
Ensure that the packing box parts are assembled in the
correct order. Packing parts can not function properly if the
Belleville springs or other packing parts are not stacked
correctly.
3. Refer to figure 1 to ensure that the packing parts
are assembled in the correct order. Install the
ENVIRO‐SEAL packing parts into the packing box.
4. Install the spring pack assembly (key 217), which
includes the attached springs, and packing flange
(key 201), on the stem. Install the nuts (key 212)
and hand tighten them.
Note
Lubrication is required for the packing studs and nuts.
Although it is important to properly lubricate the stud
threads and internal nut threads, it is also important to
properly lubricate the contacting face of the nut.
5. You will obtain maximum benefit from your
ENVIRO‐SEAL packing system when you tighten the
packing flange nuts and compress the Belleville
springs to their “target load.” The target load is the
point where the Belleville springs are designed for
optimum performance, when they are compressed
to 85% of their maximum deflection, or nearly flat.
(Maximum deflection is when the springs are 100%
compressed, or completely flat.)
To obtain the target load of 85% compression of
maximum deflection, perform the following:
www.Fisher.com

Design A, E, EH, HP, YD, & YS
ENVIRO-SEAL Duplex Packing
Installation Instructions
D300912X012
March 2021
D Tighten the packing flange nuts alternately and
evenly, keeping the packing flange parallel with
the valve flange, until the Belleville springs are
compressed 100% (or completely flat). Refer to
the ENVIRO‐SEAL Packing Instruction Manual
(D101642X012
) for more information.
D For Duplex packing, loosen each packing flange
nut 1/2 turn (180 degrees rotation). The “target
load” of 85% compression has now been
reached.
6. Refer to the appropriate valve and actuator
instruction manuals when connecting the valve to
the actuator. Under normal conditions, the packing
nuts should not require re‐tightening.
NUT
(KEY 212)
PACKING FLANGE
(KEY 201)
Packing Kits
PACKING RETROFIT PACKING REPAIR
RPACKXRTX212 RPACKX00292 3/8 (9.1)
RPACKXRTX222 RPACKX00302 1/2 (12.7)
RPACKXRTX232 RPACKX00312 3/4 (19.1)
RPACKXRTX242 RPACKX00322 1 (25.4)
RPACKXRTX252 RPACKX00332 1-1/4 (31.8)
For additional information concerning the installation
of this packing kit, please consult the appropriate
product instruction manual.
Stems and packing box constructions that do not meet
Emerson stem finish specifications, dimensional
tolerances, and design specifications, may adversely
alter the performance of this packing kit.
STUD
(KEY 200)
SPRING PACK
(KEY 217)
STEM SIZE
DIAMETER,
inches (mm)
PACKING SET
(KEY 215)
LANTERN RING
(KEY 216)
PACKING RING
(KEY 209)
PACKING BOX RING
(KEY 211)
GUIDE BUSHING
(KEY 207)
WASHER
(KEY 214)
GUIDE BUSHING
(KEY 207)
ENVIRO-SEAL DUPLEX PACKING
Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance
of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
ENVIRO-SEAL and Fisher are marks owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson
Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their
respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not
to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are
governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
Emerson Automation Solutions
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Cernay, 68700 France
Dubai, United Arab Emirates
Singapore 128461 Singapore
www.Fisher.com
2
E 1995, 2021 Fisher Controls International LLC. All rights reserved.