fadini VIGILO 2250, VIGILO 2263, VIGILO 2280 Instruction Manual

VIGILO
2250 - 2263 - 2280
GB Instructions manual pages 1 - 16
VIGILO
2250 - 2263 - 2280
POST DIAMETER 100 mm
EN 13241 EN 12453 EN 12445
the gate opener
VIGILO
VIGILO
GENERAL WARNINGS FOR PEOPLE SAFETY INTRODUCTION
This operator is designed for a specic scope of applications as indicated in this manual, including safety, control and signaling accessories as minimum required with FADINI equipment. Any applications not explicitly included in this manual may cause operation problems or damages to properties and people. Meccanica Fadini snc is not liable for damages caused by the incorrect use of the equipment, or for
English
applications not included in this manual or for malfunctioning resulting from the use of materials or accessories not recommended by the manufacturer. The manufacturer reserves the right to make changes to its products without prior notice. All that is not explicitly indicated in this manual is to be considered not allowed.
fully retractable oil-hydraulic bollard
The installer must inform and instruct the end user about the proper use of the system by releasing him a technical dossier, including: layout and components of the installation, risk analysis, verication of safety accessories, verication of impact forces and reporting of residual risks.
INFORMATION FOR END-USERS
The end-user is required to read carefully and to receive information concerning only the operation of the installation so that he becomes himself responsible for the correct use of it. The end-user shall establish a written maintenance contract with the installer/maintenance technician (on -call). Any maintenance operation must be done by qualied technicians. Keep these instructions carefully.
BEFORE INSTALLATION
Before commencing operator installation assess the suitability of the access, its general condition and the structure. To check that the ground is stable, to avoid subsequent settling or deformation in the trac control post installation area. Make sure that there is no risk of impact, crushing, shearing, conveying, cutting, entangling and lifting situations, which may prejudice people safety. Do not install near any source of heat and avoid contacts with ammable substances. □ Keep all the accessories able to turn on the operator (transmitters, proximity readers, key-switches, etc) out of the reach of the children. Transit through the access only with stationary operator. □ Do not allow children and/or people to stand in the proximity of a working operator. □ To ensure safety in the whole movement area of a bollard it is advisable to install photocells, sensitive edges, magnetic loops and detectors. Use yellow-black strips or proper signals to identify dangerous spots. Before cleaning and maintenance operations, disconnect the appliance from the mains by switching o the master switch. If removing the actuator, do not cut the electric wires, but disconnect them from the terminal box by loosening the screws inside the junction box.
INSTALLATION
All installation operations must be performed by a qualied technician, in observance of the Machinery Directive 2006/42/CE and safety regulations EN 12453 - EN 12445. Verify the presence of a thermal-magnetic circuit breaker 0,03 A - 230 V - 50 Hz upstream the installation. Use appropriate objects to test the correct functionality of the safety accessories, such as photocells, sensitive edges, etc. Carry out a risk analysis by means of appropriate instruments measuring the crushing and impact force of the main opening and closing edge in compliance with EN 12445. Identify the appropriate solution necessary to eliminate and reduce such risks. In case where the gate to automate is equipped with a pedestrian entrance, it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used. Apply safety nameplates with CE marking on the gate warning about the presence of an automated installation.
WARNINGS FOR THE CORRECT OPERATION OF THE INSTALLATION
For optimum performance of system over time according to safety regulations, it is necessary to perform proper maintenance and monitoring of the entire installation: the automation, the electronic equipment and the cables connected to these. The entire installation must be carried out by qualied technical personnel, lling in the Maintenance Manual indicated in the Safety Regulation Book (to be requested or downloaded from the site www.fadini.net/supporto/downloads). Operator: maintenance inspection at least every 6 months, while for the electronic equipment and safety systems an inspection at least once every month is required. □ The manufacturer, Meccanica Fadini snc, is not responsible for non-observance of good installation practice and incorrect maintenance of the installation.
DISPOSAL OF MATERIALS
Dispose properly of the packaging materials such as cardboard, nylon, polystyrene etc. through specializing companies (after verication of the regulations in force at the place of installation in the eld of waste disposal). Disposal of electrical and electronic materials: to remove and dispose through specializing companies, as per Directive 2012/19/UE. Disposal of substances hazardous for the environment is prohibited.
CE DECLARATION OF CONFORMITY of the manufacturer:
Meccanica Fadini snc (Via Mantova, 177/A - 37053 Cerea - VR - Italy) declares under own responsibility that: Vigilo complies with the 2006/42/CE Machinery Directive, and also that it is sold to be installed in an “automatic system”, along with original accessories and components as indicated by the manufacturing company. An automatic gate operator is, by law, a “machinery” and therefore the installer must t the equipment with all of the applicable safety norms. The installer is also required to issue the installer’s Declaration of Conformity. The manufacturer is not liable for possible incorrect use of the product. The product complies with the following specic norms: analysis of the risks and subsequent action to cure them as per EN 12445 and EN 12453, Low Voltage Directive 2014/35/UE, Electromagnetic Compatibility 2014/30/UE. In order to certify the product, the manufacturer declares under own responsibility the compliance with the EN 13241-1 PRODUCT NORMS.
Meccanica Fadini s.n.c.
Director in charge
2
VIGILO
VIGILO
INSTRUCTIONS TO BE FOLLOWED BEFORE INSTALLING THE OPERATOR
FOR OPTIMAL APPLICATION AND USE OF THE OPERATOR PLEASE READ THE INSTRUCTIONS AND CONSULT EXPLANATORY DIAGRAMS.
OVERVIEW
This product belongs to our range of retractable trac control posts. It is quick and easy to install, as it does not need to be adjusted or calibrated and has been designed to regulate and prohibit vehicular access. The oil-hydraulic bollards VIGILO 2250 (500 mm height, with or without LEDs), VIGILO 2263 (600 mm height, with or without
LEDs), VIGILO 2280 (800 mm height, with or without LEDs) are tted with posts made of rust-treated steel, 200 mm diameter;
bollards are also available in stainless steel AISI 304 version. The product’s hallmark is its ease of installation: once the housing has been secured, the operator can be introduced ready for operation, as soon as the wiring has been completed. As soon as the retractable post receives a command (from a key switch or radio transmitter), it rises from its interred position. The post is clearly visible at nighttime thanks to a reective strip and the possibility of connecting a ashing light or trac light. Versions with led lights are also available to signal when the post is in the fully up position and when moving up or down. Using the electronic microprocessor programmer, the operator can also be customised with presence indicator accessories (magnetic coils, photocells).
fully retractable oil-hydraulic bollard
English
Retractable post
Container unit inside the housing
to be sunk in a dedicated trench
in the ground
Ø 200
stroke 500 mm (Vigilo 2250) stroke 600 mm (Vigilo 2263) stroke 800 mm (Vigilo 2280)
Length of cables 10 metres
Raised post, access prohibited Lowered post, access free
3
Pic. 1
VIGILO
VIGILO
PRELIMINARY OPENING OF ALL FUNCTIONAL COMPONENTS
Start by removing the cover plate to reveal the operator and separate the individual components, with the aid of a hoist (Pic. 2): this makes it easy to extract the internal piston and hydraulic main unit container unit.
IMPORTANT: TAKE CARE NOT TO TEAR OR CUT WIRES.
!
fully retractable oil-hydraulic bollard
English
Post cover with rubber buer
Cover plate
Detail of retractable post with hoisting connection
Cylindrical container
for oil-hydraulic piston
Eyebolt
Hydraulic main unit
Motor and limit switch cables. LED and solenoid valve versions also come with pre-tted cables in lengths of 10 m each
Housing
Pic. 2
4
VIGILO
VIGILO
ELECTRICAL LAYOUT OF THE INSTALLATION
To check that the mains supply and voltage to the electric motor is 230 V at 50 Hz. The power supply to the operator’s built-in motor must be made using electricity cables with a 1,5 mm² section for a maximum distance of 50 metres. For distances of over 50 metres, use electric cables with sections suited to the installation.
fully retractable oil-hydraulic bollard
1
English
10
2x1 mm²
4x1 mm²
234
2x1 mm²
cable RG58
6
7
11
4x1 mm² 3x1 mm²
8
2x1 mm²
F
ADINI
230 V - 50 Hz
4x1 mm²
4x1 mm²
5
8
4x1 mm²
9
1 - MIRI 4-Led ashing light with built-in aerial 2 - Stand alone VIX 53/1 R radio receiver 3 - ELPRO S40 electronic programmer 4 - Dierential circuit breaker switch (sensitivity 30 mA, protection 6-10 A) 5 - Junction box, electric wires 6 - FIT 55 photocell receiver 7 - VIGILO post 8 - FIT 55 photocell projector 9 - VIX 53/4 TR transmitter 10 - Trac light with two lights 11 - CHIS 37 key-switch
6
Pic. 3
5
Loading...
+ 11 hidden pages