![](/html/fa/faa3/faa30f2a86124bf51e81a6ec524336a4844ac02c4f3d62fe85b5850818bec9e2/bg1.png)
GB Instructions manual pages 1 - 16
VIGILO
2250 - 2263 - 2280
FULLY RETRACTABLE OIL-HYDRAULIC BOLLARDS.
POST DIAMETER 100 mm
EN 13241
EN 12453
EN 12445
the gate opener
![](/html/fa/faa3/faa30f2a86124bf51e81a6ec524336a4844ac02c4f3d62fe85b5850818bec9e2/bg2.png)
VIGILO
GENERAL WARNINGS FOR PEOPLE SAFETY
INTRODUCTION
This operator is designed for a specic scope of applications as
indicated in this manual, including safety, control and signaling
accessories as minimum required with FADINI equipment. □
Any applications not explicitly included in this manual may
cause operation problems or damages to properties and
people. □ Meccanica Fadini snc is not liable for damages
caused by the incorrect use of the equipment, or for
English
applications not included in this manual or for malfunctioning
resulting from the use of materials or accessories not
recommended by the manufacturer. □ The manufacturer
reserves the right to make changes to its products without
prior notice. □ All that is not explicitly indicated in this manual
is to be considered not allowed.
fully retractable oil-hydraulic bollard
□ The installer must inform and instruct the end user about the
proper use of the system by releasing him a technical dossier,
including: layout and components of the installation, risk
analysis, verication of safety accessories, verication of
impact forces and reporting of residual risks.
INFORMATION FOR END-USERS
The end-user is required to read carefully and to receive
information concerning only the operation of the installation
so that he becomes himself responsible for the correct use of it.
□ The end-user shall establish a written maintenance contract
with the installer/maintenance technician (on -call). □ Any
maintenance operation must be done by qualied technicians.
□ Keep these instructions carefully.
BEFORE INSTALLATION
Before commencing operator installation assess the suitability
of the access, its general condition and the structure. □
To check that the ground is stable, to avoid subsequent settling
or deformation in the trac control post installation area. □
Make sure that there is no risk of impact, crushing, shearing,
conveying, cutting, entangling and lifting situations, which
may prejudice people safety. □ Do not install near any source of
heat and avoid contacts with ammable substances. □ Keep all
the accessories able to turn on the operator (transmitters,
proximity readers, key-switches, etc) out of the reach of the
children. □ Transit through the access only with stationary
operator. □ Do not allow children and/or people to stand in the
proximity of a working operator. □ To ensure safety in the
whole movement area of a bollard it is advisable to install
photocells, sensitive edges, magnetic loops and detectors. □
Use yellow-black strips or proper signals to identify dangerous
spots. □ Before cleaning and maintenance operations,
disconnect the appliance from the mains by switching o the
master switch. □ If removing the actuator, do not cut the
electric wires, but disconnect them from the terminal box by
loosening the screws inside the junction box.
INSTALLATION
All installation operations must be performed by a qualied
technician, in observance of the Machinery Directive
2006/42/CE and safety regulations EN 12453 - EN 12445. □
Verify the presence of a thermal-magnetic circuit breaker
0,03 A - 230 V - 50 Hz upstream the installation. □ Use
appropriate objects to test the correct functionality of the
safety accessories, such as photocells, sensitive edges, etc. □
Carry out a risk analysis by means of appropriate instruments
measuring the crushing and impact force of the main opening
and closing edge in compliance with EN 12445. □ Identify the
appropriate solution necessary to eliminate and reduce such
risks. □ In case where the gate to automate is equipped with a
pedestrian entrance, it is appropriate to prepare the system in
such a way to prohibit the operation of the engine when the
pedestrian entrance is used. □ Apply safety nameplates with CE
marking on the gate warning about the presence of an
automated installation.
WARNINGS FOR THE CORRECT OPERATION OF THE
INSTALLATION
For optimum performance of system over time according to
safety regulations, it is necessary to perform proper
maintenance and monitoring of the entire installation: the
automation, the electronic equipment and the cables
connected to these. □ The entire installation must be carried
out by qualied technical personnel, lling in the Maintenance
Manual indicated in the Safety Regulation Book (to be
requested or downloaded from the site
www.fadini.net/supporto/downloads).
□ Operator: maintenance inspection at least every 6 months,
while for the electronic equipment and safety systems an
inspection at least once every month is required. □ The
manufacturer, Meccanica Fadini snc, is not responsible for
non-observance of good installation practice and incorrect
maintenance of the installation.
DISPOSAL OF MATERIALS
Dispose properly of the packaging materials such as
cardboard, nylon, polystyrene etc. through specializing
companies (after verication of the regulations in force at the
place of installation in the eld of waste disposal). Disposal of
electrical and electronic materials: to remove and dispose
through specializing companies, as per Directive 2012/19/UE.
Disposal of substances hazardous for the environment is
prohibited.
CE DECLARATION OF CONFORMITY of the manufacturer:
Meccanica Fadini snc (Via Mantova, 177/A - 37053 Cerea - VR - Italy) declares under own responsibility that: Vigilo complies
with the 2006/42/CE Machinery Directive, and also that it is sold to be installed in an “automatic system”, along with original
accessories and components as indicated by the manufacturing company. An automatic gate operator is, by law, a
“machinery” and therefore the installer must t the equipment with all of the applicable safety norms. The installer is also
required to issue the installer’s Declaration of Conformity. The manufacturer is not liable for possible incorrect use of the
product. The product complies with the following specic norms: analysis of the risks and subsequent action to cure them
as per EN 12445 and EN 12453, Low Voltage Directive 2014/35/UE, Electromagnetic Compatibility 2014/30/UE. In order to
certify the product, the manufacturer declares under own responsibility the compliance with the EN 13241-1 PRODUCT
NORMS.
Meccanica Fadini s.n.c.
Director in charge
2
![](/html/fa/faa3/faa30f2a86124bf51e81a6ec524336a4844ac02c4f3d62fe85b5850818bec9e2/bg3.png)
VIGILO
INSTRUCTIONS TO BE FOLLOWED BEFORE INSTALLING THE OPERATOR
FOR OPTIMAL APPLICATION AND USE OF THE OPERATOR PLEASE READ THE INSTRUCTIONS AND CONSULT EXPLANATORY DIAGRAMS.
OVERVIEW
This product belongs to our range of retractable trac control posts. It is quick and easy to install, as it does not need to be
adjusted or calibrated and has been designed to regulate and prohibit vehicular access.
The oil-hydraulic bollards VIGILO 2250 (500 mm height, with or without LEDs), VIGILO 2263 (600 mm height, with or without
LEDs), VIGILO 2280 (800 mm height, with or without LEDs) are tted with posts made of rust-treated steel, 200 mm diameter;
bollards are also available in stainless steel AISI 304 version.
The product’s hallmark is its ease of installation: once the housing has been secured, the operator can be introduced ready for
operation, as soon as the wiring has been completed.
As soon as the retractable post receives a command (from a key switch or radio transmitter), it rises from its interred position.
The post is clearly visible at nighttime thanks to a reective strip and the possibility of connecting a ashing light or trac light.
Versions with led lights are also available to signal when the post is in the fully up position and when moving up or down.
Using the electronic microprocessor programmer, the operator can also be customised with presence indicator accessories
(magnetic coils, photocells).
fully retractable oil-hydraulic bollard
English
Retractable post
Container unit inside the housing
to be sunk in a dedicated trench
in the ground
Ø 200
stroke 500 mm (Vigilo 2250)
stroke 600 mm (Vigilo 2263)
stroke 800 mm (Vigilo 2280)
Length of cables 10 metres
Raised post, access prohibited Lowered post, access free
3
Pic. 1
![](/html/fa/faa3/faa30f2a86124bf51e81a6ec524336a4844ac02c4f3d62fe85b5850818bec9e2/bg4.png)
VIGILO
PRELIMINARY OPENING OF ALL FUNCTIONAL COMPONENTS
Start by removing the cover plate to reveal the operator and separate the individual components, with the aid of a hoist (Pic. 2):
this makes it easy to extract the internal piston and hydraulic main unit container unit.
IMPORTANT: TAKE CARE NOT TO TEAR OR CUT WIRES.
!
fully retractable oil-hydraulic bollard
English
Post cover with
rubber buer
Cover plate
Detail of retractable post
with hoisting connection
Cylindrical container
for oil-hydraulic piston
Eyebolt
Hydraulic main unit
Motor and limit switch cables.
LED and solenoid valve versions
also come with pre-tted
cables in lengths of 10 m each
Housing
Pic. 2
4
![](/html/fa/faa3/faa30f2a86124bf51e81a6ec524336a4844ac02c4f3d62fe85b5850818bec9e2/bg5.png)
VIGILO
ELECTRICAL LAYOUT OF THE INSTALLATION
To check that the mains supply and voltage to the electric motor is 230 V at 50 Hz.
The power supply to the operator’s built-in motor must be made using electricity cables with a 1,5 mm² section for a maximum
distance of 50 metres. For distances of over 50 metres, use electric cables with sections suited to the installation.
fully retractable oil-hydraulic bollard
1
English
10
2x1 mm²
4x1 mm²
234
2x1 mm²
cable RG58
6
7
11
4x1 mm²
3x1 mm²
8
2x1 mm²
F
ADINI
230 V - 50 Hz
4x1 mm²
4x1 mm²
5
8
4x1 mm²
9
1 - MIRI 4-Led ashing light with built-in aerial
2 - Stand alone VIX 53/1 R radio receiver
3 - ELPRO S40 electronic programmer
4 - Dierential circuit breaker switch (sensitivity 30 mA, protection 6-10 A)
5 - Junction box, electric wires
6 - FIT 55 photocell receiver
7 - VIGILO post
8 - FIT 55 photocell projector
9 - VIX 53/4 TR transmitter
10 - Trac light with two lights
11 - CHIS 37 key-switch
6
Pic. 3
5