BYAN SYSTEMS, INC. OF LUSK, WYOMING, DEMANDS THAT YOU AS AN INSTALLER
INFORM YOUR CUSTOMER OF ALL SAFETY EQUIPMENT THAT SHOULD BE INSTALLED
ON EACH JOB SITE. THIS IS IN ACCORDANCE WITH YOUR LEGAL LIABILITY TO YOUR
CUSTOMER. ENSURE THAT THE PROTECTION AND WARNING SIGNALING DEVICES ARE
OPERATIONAL AND VISIBLE. THESE STEPS WILL AID IN YOUR DEFENSE SHOULD YOU
P.O. BOX 1384 FAX (307) 334-2028
INSTALLATION AND TECHNICAL MANUAL
BECOME INVOLVED IN LITIGATION REGARDING INJURY OR DAMAGE.
ATTENTION: ALL INSTALLERS EXPERIENCED OR NOT PLEASE REVIEW
PAGES 4 AND 9 BEFORE YOU INSTALL THIS ACTUATOR.
BYAN SYSTEM, INC.
413 LINDEN
LUSK, WY 82225
(800) 223-2926
MODEL 800A/900B SERIES
VEHICULAR SWING
GATE OPERATOR
BYAN SYSTEMS, INC.
Automated Gate and Access Control Products
TABLE OF CONTENTS
DESCRIPTION PAGE NO.
USAGE CLASSES FOR VEHICULAR GATE OPERATOR 2
TECHNICAL DATA ABOUT THE OPERATOR 3
BEFORE YOU INSTALL 4
DURING INSTALLATION PROCEDURES 4
INSTALLATION COMPLETION/FOLLOW UP 5
INSTALLING THE OPERATOR 6
PURGING THE OPERATOR 7
PRESSURE ADJUSTMENTS 8
HYDRAULIC FLUID 8
MANUAL BYPASS 9
MOUNTING GEOMETRY 10
MOUNTING BRACKET LOCATION 11
FRONT MOUNTING DETAIL 12
WIRING THE CONTROL AND ACCESSORIES 13
CONNECTING THE OPERATOR 19
LOOP CONNECTORS 21
WARRANTY 26
END USER SAFETY 27
CUSTOMER ACKNOWLEDGMENT 29
413 Linden • Lusk, WY 82225 • (800) 223-2926
1
BYAN SYSTEMS, INC.
Automated Gate and Access Control Products
USAGE CLASSES FOR
VEHICULAR GATES
CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR
A VEHICULAR GATE OPERATOR (OR SYSTEM) INTENDED FOR USE IN A HOME OF
ONE TO FOUR SINGLE FAMILY DWELLING, OR A GARAGE OR PARKING AREA
ASSOCIATE THEREWITH.
CLASS II – COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR
A VEHICULAR GATE OPERATOR (OR SYSTEM) INTENDED FOR USE IN A
COMMERCIAL LOCATION OR BUILDING SUCH AS A MULTI-FAMILY HOUSING
UNIT (FIVE OR MORE SINGLE FAMILY UNITS), HOTEL, GARAGES, RETAIL STORES,
OR OTHER BUILDING SERVICING THE GENERAL PUBLIC.
CLASS III – INDUSTRIAL/LIMITED ACCESS VEHICULAR GATE OPERATOR
A VEHICULAR GATE OPERATOR (OR SYSTEM) INTENDED FOR USE IN AN
INDUSTRIAL LOCATION OR BUILDING SUCH AS A FACTORY OR LOADING DOCK
AREA OR OTHER LOCATION NOT INTENDED TO SERVICE THE GENERAL PUBLIC.
CLASS IV – RESTRICTED ACCESS VEHICULAR GATE OPERATOR
A VEHICULAR GATE OPERATOR (OR SYSTEM) INTENDED FOR USE IN A GUARDED
INDUSTRIAL LOCATION OR BUILDING SUCH AS AN AIRPORT SECURITY AREA OR
OTHER RESTRICTED ACCESS LOCATION NOT SERVICING THE GENERAL PUBLIC,
IN WHICH UNAUTHORIZED ACCESS IS PREVENTED VIA SUPERVISION BY
SECURITY PERSONNEL.
413 Linden • Lusk, WY 82225 • (800) 223-2926
2
BYAN SYSTEMS, INC.
Automated Gate and Access Control Products
800A/900A SERIES TECHNICAL DATA
MODEL 800A: 220 VAC SINGLE PHASE
MODEL 900B: 115 VAC SINGLE PHASE
ELIMINATOR SERIES BUILT-IN THERMAL OVERLOAD
CAPACITOR RATING: 10UF FOR THE 800A
35UF FOR THE 900A
STANDARD WORKING PRESSURE: 1350 PSI
MAXIMUM WORKING PRESSURE: 1750 PSI
PUMP: SPUR GEAR 1.0 LTR/MIN.
MOTOR: 1/6 HORSE POWER
OPERATOR LENGTH WITH PISTON 754 TO 904 MILLIMETERS
RETRACTED AND REAR BRACKET AND 29-11/16 TO 35-5/8 INCHES
SWIVEL INSTALLED
OPERATOR LENGTH EXTENDED WITH REAR 1004 TO 1304 MILLIMETERS
BRACKET AND SWIVEL JOIN INSTALLED 39 TO 51 5/16 INCHES
OPERATOR WIDTH: 3-3/8 X 3-3/8 INCHES
4-5/16 WITH LOCK
OPERATOR SPEED TO 90 DEGREES: 13 SEC. FOR 800A
13 SEC. FOR 900A
PISTON STROKE: 250 MM OR 9-7/8 INCHES
400 MM OR 15-3/4 INCHES
AMBIENT OPERATOR TEMPERATURE RANGE: -60 TO 220 DEGREES F
HYDRAULIC FLUID: SHELL TELLUS T-15
THIS PATENTED NEW CONCEPT IN LINEAR ACTUATOR DESIGN ELIMINATES THE NEED
FOR PHYSICAL STOPS. THE VALVE DESIGN CUSHIONS THE LAST HALF INCH OR ABOUT
THE LAST 5 TO 10 DEGREES OF PISTON TRAVEL ALLOWING THE PISTON TO REACH END
OF STROKE IN BOTH DIRECTIONS AND PREVENT INTERNAL DAMAGES.
OPERATOR BODY FABRICATED IN ANODIZED ALUMINUM
FRONT AND REAR FLANGES ARE CAST ALUMINUM
ALL INTERNAL COMPONENTS ARE CAST AND MACHINED
INTERNAL COMPONENTS BATHED IN OIL SO VIRTUALLY NO MAINTENANCE REQUIRED.
413 Linden • Lusk, WY 82225 • (800) 223-2926
3
BYAN SYSTEMS, INC.
Automated Gate and Access Control Products
BEFORE INSTALLATION
1. VERIFY THE GATE POST IS PLUM AND GATE LEAF SWINGS FREELY.
2. PERFORM ANY REQUIRED MAINTENANCE BEFORE CONTINUING.
3. VERIFY THE COMMERCIAL POWER CIRCUIT BREAKERS ARE ISOLATED AND RATED FOR
THE SPECIFIC LOAD. VISUALLY ENSURE THE CIRCUIT BREAKERS ARE IN THE “OFF”
POSITION AND MARK THE BREAKER USED.
4. IF ANY PRE-CONSTRUCTION WIRING HAS BEEN INSTALLED, VISUALLY INSPECT AND
CONFIRM PROPER SIZING AND COMPLIANCE TO CODE.
5. AUTOMATIC VEHICULAR GATES ARE NOT APPROVED FOR PEDESTRIAN TRAFFIC,
HOWEVER, THEY CAN CREATE HAZARDS TO UNSUSPECTING PEDESTRIANS AND
DOMESTIC ANIMALS. ANY GATE, CONSTRUCTED WITH REACHABLE PINCH POINTS, OR
HAS A SURFACE AREA THAT ALLOWS ARMS OR LEGS TO PASS THROUGH, IS A
POTENTIAL HAZARD. RECOMMEND AND PROVIDE SAFE GUARDS AGAINST THESE
HAZARDS
6. REMOVE THE “END USER SAFETY ADVISORY HANDOUT” FROM THIS MANUAL. REQUEST
THE END USER REVIEW THE MATERIAL AND SIGN IT. COLLECT THE HANDOUT WHEN
THE JOB IS COMPLETE.
.
DURING INSTALLATION
1. LOCATE THE ELECTRONIC CONTROLS FAR ENOUGH FROM THE GATE SO THE END USER
CAN OBSERVE, BUT NOT TOUCH, THE GATE WHILE OPERATING THE CONTROLS.
2. WHEN CONNECTING THE WIRING FROM THE COMMERCIAL POWER SOURCE TO THE
CONTROL PANEL, MAKE SURE YOU HAVE PROVIDED A PROPER EARTH GROUND. IF
USING A METAL ENCLOSURE, CONNECT THE GROUND TO THE ENCLOSURE BEFORE
CONNECTING TO THE GATE OPERATORS. NO GROUND IS TO CONNECTING TO THE GATE
OPERATORS. NO GROUND IS TO CONNECT DIRECTLY TO THE MICROPROCESSOR
CONTROL.
3. OBSERVE ALL WIRING REQUIREMENTS ESTABLISHED BY THE NATIONAL ELECTRICAL
CODE AND/OR THE AUTHORITY HAVING JURISDICTION.
4. MOUNT HE LINEAR ACTUATOR AS CLOSE TO THE CENTER OF THE GATE LEAF AS
POSSIBLE. THIS WILL HELP BALANCE THE WHIPPING MOTION OF THE GATE WHEN THE
OPERATOR REACHES END OF THE PISTON STROKE.
5. ISOLATE THE LINEAR ACTUATOR WHEN WELDING TO PREVENT ANY CURRENT FROM
PASSING THROUGH THE OPERATOR AND DAMAGING THE MOTOR OR OTHER
COMPONENTS.
413 Linden • Lusk, WY 82225 • (800) 223-2926
4
BYAN SYSTEMS, INC.
Automated Gate and Access Control Products
INSTALLATION COMPLETION
1. INSTALL PLACARDS AND SAFETY EQUIPMENT AND TEST.
2. “REMOVE” ALL DEBRIS AND OBSTRUCTIONS FROM THE TRAVEL PATH OF THE GATE
LEAF(S).
3. TURN ON AND LABEL THE COMMERCIAL POWER CIRCUIT BREAKER AND REMOVE THE
“USED” TAG YOU INSTALLED AT THE BEGINNING OF THE PROJECT.
4. USING THE MANUAL BYPASS, POSITION THE GATE LEAF AT 45 DEGREES. PRESS THE
TEST BUTTON ON THE G2M CONTROL BOARD. THE FIRST SIGNAL WILL ALWAYS BE TO
OPEN. IF THE OPERATOR RUNS TO THE CLOSED POSITION, TURN OFF THE COMMERCIAL
POWER AND REVERSE THE MOTOR CONNECTIONS ON PINS 1 AND 3.
5. OPERATE THE ACTUATOR SEVERAL TIMES UNTIL YOU CAN DETECT A RISE IN THE
FLUID TEMPERATURE. PLACING YOUR HAND ON THE TOP OF THE OPERATOR AT THE
REAR CAN DO THIS.
6. PURGE AND ADJUST THE OPERATOR AS DESCRIBED IN THE PURGING AND ADJUSTMENT
SECTION.
7. INSTRUCT THE END USER HOW TO MANUALLY RELEASE THE GATE IN THE EVENT OF A
POWER FAILURE.
8. INSTRUCT THE END USER HOW TO PROPERLY OPERATE THE GATE AUTOMATION AND
SAFETY FEATURES THEREOF.
9. COLLECT THE “SIGNED” END USER SAFETY HAND OUT. BY THEIR SIGNATURE, THE END
USER ACKNOWLEDGES THEIR UNDERSTANDING OF THEIR RESPONSIBILITIES OF
OWNING, OPERATING, AND MAINTAINING A VEHICULAR AUTOMATIC GATE OPERATING
SYSTEM.
413 Linden • Lusk, WY 82225 • (800) 223-2926
5
BYAN SYSTEMS, INC.
Automated Gate and Access Control Products
INSTALLING THE OPERATOR
! ADVISORIES!
A. THIS LINEAR ACTUATOR MUST ME MOUNTED SO THE PISTON FULLY EXTENDS
AND FULLY RETRACTS. WHEN FULLY RETRACTED THERE SHOULD BE 1/8 INCH
PISTON LEFT OUT OF THE FRONT.
B. THIS LINEAR ACTUATOR HAS AN OFFSET BETWEEN THE FRONT AND REAR
MOUNTING BRACKET. THE FRONT BRACKET IS ABOUT 5/8 OF AN INCH LOWER
THAN THE FRONT BRACKET; REVIEW THE BRACKET ALIGNMENT DETAIL FOR
THE OFFSET DIMENSION. THE FRONT BRACKET HAS THE TALLER SHOULDER.
1. SCRIBE A LINE FROM THE HORIZONTAL SUPPORT OR DESIRED HEIGHT FOR THE
OPERATOR ON THE GATE LEAF ONTO THE GATE POST.
2. MEASURE FOR THE OFFSET DESCRIBED IN THE ADVISORY #B AND SCRIBE
ANOTHER LINE.
3. CUT THE REAR MOUNTING BRACKET IN ACCORDANCE WITH THE DIMENSIONS
SPECIFIED ON THE MOUNTING GEOMETRY DETAIL.
4. WELD THE REAR MOUNTING BRACKET TO THE GATE POST.
5. DETERMINE THE “C” DIMENSION AND CUT THE FRONT MOUNTING BRACKET TO
THE PROPER LENGTH.
6. EXTEND THE PISTON TO FULLY EXTENDED POSITION FOR INWARD SWING
GATES. THIS CAN BE ACHIEVED BY TEMPORARILY CONNECTING THE CONTROL
PANEL TO THE OPERATOR AND USING THE MOTOR TO EXTEND THE PISTON,
PRODUCING 9 7/8” OF PISTON. IT IS VERY IMPORTANT WITH THE “800A/900A”
THAT THE PISTON “BOTTOMS OUT IN BOTH DIRECTIONS”.
7. SCREW THE “I” BOLT INTO THE END OF THE PISTON 1/2 TO 3/4 OF THE LENGTH OF
THE THREADS. ATTACH THE FRONT BRACKET TO THE OPERATOR.
8. ATTACH THE OPERATOR TO THE REAR MOUNTING BRACKET.
9. WITH THE GATE IN THE FULL CLOSED POSITION, LEVEL THE OPERATOR AND
SCRIBE THE LOCATION FOR THE FRONT MOUNTING BRACKET.
10. REMOVE THE FRONT MOUNTING BRACKET FROM THE FRONT OF THE GATE
OPERATOR AND WELD IT TO THE GATE LEAF AT THE SCRIBED LOCATION.
11. ATTACH THE OPERATOR TO THE FRONT MOUNTING BRACKET.
413 Linden • Lusk, WY 82225 • (800) 223-2926
6
BYAN SYSTEMS, INC.
Automated Gate and Access Control Products
12.CONNECT THE CORD PER THE ELECTRICAL CONNECTION DETAILS.
NOTE: IT IS HELPFUL TO INSTALL A SINGLE GANG WEATHER PROOF BELL BOX
ON THE GATE POST ACROSS FROM THE OPERATOR. THEN WIRE FROM THE
CONTROL BOX CAN BE PULLED TO THIS POINT AND CONNECTED TO THE S.O.
CORD INSIDE THE BELL BOX.
PURGING THE OPERATOR
SOMETIMES DURING SHIPPING, THE “800A/900A” SERIES OPERATOR GETS
TURNED UPSIDE DOWN AND REQUIRES THE VALVE SYSTEM TO BE PURGED
AFTER YOU HAVE COMPLETED THE INSTALLATION. THIS CAN BE NOTICED IF
THE OPERATOR IS JERKING OR RUNS UNEVEN.
TIGHTEN THE BYPASS VALVE WITH THE ALLEN WRENCH AND GIVE THE
OPERATOR A SIGNAL TO RUN. WHILE THE MOTOR IS RUNNING, OPEN AND
CLOSE THE BYPASS VALVE PAUSING BETWEEN OPEN AND CLOSE. DO THIS 10 TO
12 TIMES. THEN REMOVE THE FILL CAP TO EXPEL ANY AIR IN THE OPERATOR.
REPLACE THE OIL FILLER CAP SCREW AND TIGHTEN ONLY SNUG.
ADJUSTING THE OPERATOR
THE PRESSURES ON THE OPERATOR ARE PRESET AT BYAN SYSTEMS PRIOR
TO SHIPMENT. IF THE PRESSURES DO NEED TO BE ADJUSTED, WHETHER
HIGHER OR LOWER, YOU MUST ADJUST BOTH DIRECTIONS THE SAME
NUMBER OF TURNS (i.e. 1/4 TURN, 1/2 TURN ETC.)
THE PRESSURE ADJUSTMENT SCREWS ARE FOUND UNDER THE LOCKING CAP ON
THE TOP OF THE OPERATOR. LOOKING FROM THE REAR TO THE FRONT OF THE
OPERATOR, THE LEFT VALVE IS FOR RETRACTING PRESSURE AND THE RIGHT
VALVE IS FOR EXTENDING PRESSURE. WITH THE MOTOR RUNNING DECREASE
THE PRESSURES EQUALLY UNTIL THE OPERATOR STOPS MOVING IN BOTH
DIRECTIONS. BEGIN INCREASING PRESSURE ON BOTH VALVES WITH THE
MOTOR RUNNING. ADJUST THE PRESSURE TO WHERE YOU HAVE TO
PHYSICALLY STOP THE GATE. AT THIS POINT, EITHER INCREASE THE
RETRACTING PRESSURE TURN OR DECREASE THE EXTENDING PRESSURE
TURN. RETRACTING HAS TO BE A LITTLE HIGHER.
413 Linden • Lusk, WY 82225 • (800) 223-2926
7
BYAN SYSTEMS, INC.
Automated Gate and Access Control Products
HYDRAULIC FLUID
BYAN SYSTEMS OPERATORS US A “SHELL OIL PRODUCTS” TELLUS T-15, THIS
FLUID HAS A RELATIVELY LOW VISCOSITY SO IT WILL START TO FLOW QUICKLY
ON COLD DAYS. WHEN THE FLUID RISES TO OPERATING TEMPERATURE, THERE
IS NO RUSH OF THIN FLUID CAUSING POOR HYDRAULIC PERFORMANCE, OR
WORSE YET, EXCESSIVE PUMP WEAR, FAILURE AND EXPENSIVE DOWNTIME.
TELLUS FLUIDS MINIMIZE THE EFFECT TEMPERATURE HAS ON VISCOSITY, AND
RESISTS THE SHEARING ACTION OF HIGH SPEED PUMPS BY MAINTAINING THEIR
STABLE VISCOSITY LONGER.
THERE IS A ZINC TYPE ADDITIVE IN THE FLUID TO HELP IMPEDE WEAR AND
PREMATURE REPLACEMENT. IT HELPS PREVENT CORROSION TO METALS AND IS
DESIGNED TO BE COMPATIBLE WITH HOSES, SEALS AND OTHER ELASTOMER
PRODUCTS.
TELLUS T-15 READILY SEPARATES AIR AND WATER TO PREVENT FOAMING,
KEEPING THE FLUID FIT AND DIELECTRIC STRENGTH HIGH.
WHERE TO BUY SHELL TELLUS FLUIDS
AT YOUR NEAREST SHELL DISTRIBUTOR, BYAN SYSTEMS DISTRIBUTOR, OR AT
BYAN SYSTEMS WAREHOUSE.
FLUID AND YOUR OPERATOR
THE OPERATOR HOLDS APPROXIMATELY 1 QUART OF FLUID. THE PROPER
LEVEL CAN BE OBSERVED THROUGH THE OIL FILLER TUBE, LOCATED ON THE
TOP OF THE REAR FLANGE OF THE OPERATOR, WITH THE PISTON IN THE
RETRACTION POSITION, THE FLUID SHOULD BE VISIBLE AT THE BOTTOM OF THE
TUBE, LEVEL WITH THE CURVED SECTION OF THE TUBE. THE 500 SERIES
OPERATOR HAS A PRESSURED CHAMBER SO DO NOT OVERFILL. THE PUMP WILL
INTERMITTENTLY FAIL TO DRAW FLUID AND WILL FAIL TO RUN IN ONE
DIRECTION OR THE OTHER.
413 Linden • Lusk, WY 82225 • (800) 223-2926