Reading the LCD (Temperature) Display ................................................................................... 24
Interpreting System Icons ............................................................................................................ 25
Interpreting System Alerts ........................................................................................................... 25
Data Log ............................................................................................................................................. 26
Downloading Data ........................................................................................................................ 26
Clearing the Data log (After downloading) ............................................................................... 26
How to Upload SilverPoint™ data to a Computer .................................................................... 27
Adjusting the Data Log Interval ................................................................................................... 27
Uploading and Viewing your Data .............................................................................................. 27
How do I connect to WiFi? ........................................................................................................... 41
See User guide to walk through steps ........................................................................................ 41
Replacement Parts ............................................................................................................................ 42
Product Warranty and Service ......................................................................................................... 43
Page
5 |
Evolve™, A New Cold Has Arrived
The SilverPoint remote and local temperature monitoring accessory and can
information.
Phononic is changing the paradigm of refrigeration with Evolve. Evolve products operate
TM
with a patented SilverCore
temperature monitoring system called SilverPoint™.
The Evolve family of products dramatically modernizes cold storage technology for medical
and healthcare facilities and offers a complete solution for protecting vaccines, medications,
and temperature-sensitive materials.
Thank you for purchasing the most advanced refrigeration technology available.
SilverCore Solid State, Compressor-free Refrigeration System
Your Evolve refrigerator operates with a refrigeration system that actively channels heat
energy through a non-toxic refrigerant and the Phononic solid-state heat pump, resulting in
unprecedented cooling capabilities within the chamber. Our compressor-free design
requires minimal maintenance, consumes less power, eliminates the use of toxic coolants,
and operates within whisper-quiet noise levels. As an added benefit, Evolve products can
continuously operate on UPS battery backup power to protect precious content during
power outage events.
refrigeration system and come equipped with an embedded
SilverPoint Temperature Monitoring System
SilverPoint is an embedded temperature monitoring system with both USB downloadable
local data storage and WiFi enabled remote data access. Access the SilverPoint web portal to
create a multi-unit temperature monitoring dashboard, view historical records and set up
email and mobile text alert notifications.
The SilverPoint temperature monitoring system is designed to be compliant with CDC
recommendations for vaccine storage.
be added to any Evolve refrigerator. Visit portal.phononic.com for more
Page
6 |
Network Setup Details
Page
7 |
Product/Technical Specifications
General Specifications and Features
Model Series
ELR018SSA
Model Style
52 L compact refrigerator
Materials
Durable stainless steel exterior with easy-to-clean
Internal Chamber Capacity
52 liters
Chamber Temperature Uniformity
+/- 1 °C from center air temperature
Cooling System
SilverCore refrigeration system with Phononic solid-
Refrigerant
R744, non-flammable, zero ozone depleting, low
Refrigerant Charge Quantity
24.1 grams
Refrigerant Pressure Rating
12410 kpa
Energy Consumption
2047 btu/24 hrs @ 4 °C
Insulation
CFC-free insulation
Display
Full-color 61 mm LCD with LED backlighting
Power Cord
1 meter, NEMA hospital grade plug
Noise Level
<30 dBA @ 1m
Power Input
100-240 VAC, 50-60 Hz, 1.2 A
Amps
1.2 A
interior aluminum walls
state heat pump
toxicity
Output
Product IP rating
Agency Approvals
International Approval
NRTL Mark
CAN Recognition
RoHS
REACH
Page
Class 1 USB port
IP 31
CE
UL, MET
UL, MET
TRNA
TRNA
8 |
Physical Dimensions
Weight
34 Kg
Outer Dimensions
521 mm W x 561 mm D x 584 mm H
20.5” W x 22.1” D x 23” H
Internal Dimensions
363 mm W x 310 mm D x 467 mm H
Data Monitoring and Logging
WiFi Connectivity
2.4 GHz 802.11 b/g/n compatible, as equipped*
Memory
512 kb flash memory
Access I/O Ports
One 3.5 mm port for expanded temperature
Temperature Sensors
Interior chamber air and glycol
Environmental Operating Conditions
Ambient Temperature Range
32 °C maximum temperature environment
Humidity Range
Low humidity. Not warranted for outdoor use
Warranty
Warranty
2 years on all parts and labor from date of purchase
* Some models are not equipped with WiFi connectivity
14.3” W x 12.2” D x 18.4” H
monitoring
Page
9 |
Compliance Statements
any interference received, including interference that may cause undesired operation.
Hazardous voltages are present: To reduce the risk of electric shock and danger to personal
Consult the dealer or an experienced radio/TV technician for help
Hazardous voltages are present: To reduce the risk of electric shock DO NOT remove the
qualified personnel.
use undesired
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
Attention
Warning
Attention
Attention
For Class B - Unintentional Radiators:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference and (2) this device must accept
health, follow the instructions provided in this manual.
ICES-003 Class B Notice—Avis NMB-003, Classe B
This Class B digital apparatus complies with Canadian ICES-003.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected
Warning
Radiation
Hazard
Attention
Warning
Page
Attention
rear cover on this product. There are no user serviceable parts inside. Please refer service to
In order satisfy the FCC RF exposure limit for transmitting devices, a separation distance of 20
cm should be maintained between the body and the Evolve refrigerator while in operation.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2) this
device must accept any interference, including interference that may ca
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil
ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
fonctionnement.
The antenna used for this transmitter must not be co-located in conjunction with any other
antenna or transmitter.
Any modifications made to this device that are not approved by Phononic may void the
authority granted to the user by the FCC to operate equipment.
10 |
Intended Use of the Evolve™ Refrigerator
The Evolve 1.8 ft³ refrigerator is designed, developed and manufactured for pharmacy,
laboratory, clinical, hospital and extended use for cold storage of vaccines, drugs and relative
products designated for cold storage of temperatures between 2 °C and 8 °C.
Wiring Diagram
Provided for informational purposes only. For repairs or operating issues, please call
Technical Service.
Page
11 |
Safety Precautions
Refer to Unpacking your Evolve Refrigerator for details on handling and
moving the unit.
Used to identify an Evolve Compact Refrigerator, SilverCore Cooling System
or SilverPoint Embedded Monitoring System benefit.
All electrical appliances present some risk of injury. Your Evolve™ refrigerator is designed to
meet safety standards.
Take care to carry and move your refrigerator with caution. Do not place it where it can fall,
be dropped, or where the electrical connection can be submerged into water or other
liquids. If you are placing your Evolve refrigerator on a countertop, make sure all four leveling
feet are on the countertop and that you can open and close the unit without unbalancing it.
There are no user-serviceable parts within the Evolve 52 L product.
Symbols used in this Manual
Used to indicate an electrical shock hazard.
Used when advice is given to prevent malfunction or injury.
Used to prohibit flammable items.
Used to advise not proceeding with an action.
Used to offer a recommended practice.
Page
12 |
Refrigerant Pressure
When the Evolve refrigerator is unplugged from a power source, venting the
person.
Do not remove the rear cover or operate unit with rear cover removed.
factory authorized service person.
pressure regulating relief valves on the refrigeration system can occur. In
such cases, the system may need to be recharged with R744. However, the
pressure regulating valves are not to be defeated or capped. Do not tamper
with or alter the relief setting. Service only by a factory authorized service
Electrical Components
Removal of the rear cover can result in electrical shock. Service only by a
Page
13 |
Unpacking Your Evolve Refrigerator
Do not call the Evolve service line to report shipping damages. Call your
carrier.
Inspecting for Damage
Please take a moment to inspect your new refrigerator for damage that may have occurred
during shipping. Please contact the delivery carrier directly for any damage that occurred
during shipping.
We have designed intelligent packaging to assist you in unpacking your Evolve compact
refrigerator. Your Evolve product was built, inspected, tested, and packaged with extreme
care. Follow the directions provided to unpack your new product safely and easily.
Lifting, Carrying, Locating and Unboxing
We recommend that you move the box as close as possible to its final location before you
begin to unpack. This unit is not provided with handles, therefore it is recommended that 2
people move and remove the refrigerator from the packaging by lifting at the base of the
refrigerator. The packaged unit weighs nearly 83 pounds (38 Kg), so lift it with caution.
Remove the packing straps and lift the top cover of the box to expose the refrigerator for
removal and placement.
Identifying All Parts
Page
Loading...
+ 30 hidden pages
You need points to download manuals.