EVCO EV9326J9 User Manual

Evco S.p.A. • Code 1049326E00 • page 1/6
EV9326 Digital controller with 6 outputs for electric bread ovens, with cooking timer and rapid heating
functions version 3.00
E ENGLISH
1 IMPORTANT
1.1 Important
Read these instructions carefully before installation and use and fol-
low all warnings regarding installation and for the electric connec-
The instrument must be disposed of in compliance with
local Standards relative to the collection of electrical and
electronic appliances.
1.2 Dimensions and installation
Panel with supplied brackets with screws; dimensions in mm (in).
DIMENS. MINIMUM TYPICAL MAXIMUM
A 92.0 (3.622) 92.0 (3.622) 92.8 (3.653)
B 92.0 (3.622) 92.0 (3.622) 92.8 (3.653)
Installation recommendations:
• the thickness of the panel must not exceed 4.0 mm (0.157 in)
• position the brackets as indicated in the drawing in this paragraph,
moderate the coupling torque
• make sure that the working conditions (temperature of use, humid-
ity, etc.) lie within the limits indicated in the technical data
• do not install the instrument in proximity of heat sources (resistances,
hot air pipes, etc.), appliances with strong magnets (large diffusers,
etc.), places subject to direct sunlight, rain, humidity, excessive dust,
mechanical vibrations or jerks
• in compliance with Safety Standards, protection against any contact
with electrical parts must be assured via correct installation of the
instrument. All parts that ensure protection must be fixed in a way
that they cannot be removed without the aid of a tool.
1.3 Electric connection
With reference to the wiring diagram: the serial port is the port for the
communication with the supervising system (through a serial inter-
face, via TTL, with MODBUS communication protocol) or with the
programming key;
same time.
the port must not be used for two purposes at the
Recommendations for the electric connection:
• do not operate on the terminal boards using electric or pneumatic
• if the instrument has been taken from a cold place to a hot place, the humidity could condense inside; wait for about one hour before applying power
• check that the power supply voltage, the frequency and the electric operational power of the instrument correspond with those of the local power supply
• disconnect the power supply before performing any type of main­tenance
• supply the probes with protection able to isolate them from any contact with metal parts or use isolated probes
• do not use the instrument as a safety device
• for repairs and information regarding the instrument, contact the Evco sales network.
2 PRELIMINARY CONSIDERATIONS
2.1 Preliminary considerations
The instrument can be configured to function with 1 measurement input (default, chamber probe) or with 2 measurement inputs (top probe and floor probe). If functioning with 1 measurement input it is however possible to enable a second probe (steam probe) to subor­dinate the injection of steam at the temperature of the same. Functioning with 1 measurement input allows to independently set the power distributed to the top to that distributed to the floor. Func­tioning with 2 measurement inputs allows to independently set the top and floor work temperatures. The utilities managed by the digital outputs (i.e. relays K1 ... K6) are the following:
RELAY MANAGED UTILITY
K1 top
K2 floor
K3 can be set (default chamber light)
K4 airhole
K5 steam injection
K6 can be set (default steam generator)
To set the type of functioning (with 1 measurement input rather than
2) see paragraph 4.1. However, to set the utility managed by relay K3
and relay K6 see paragraph 4.2.
2.2 Management of the utilities
Top. If functioning with 1 measurement input:
• the output is switched on in cyclical mode, preferably when the floor output is off (the parameter c1 establishes the cycle time. The procedure given in paragraph 4.4 can be used to set the duration of output switch-on, intended as a percentage of the time estab­lished with parameter c1)
• the cyclical activity is subject to the chamber temperature (chamber probe), to the work set-point and parameter r0.
If functioning with 2 measurement inputs:
• the output activity depends mainly on the top temperature (top probe), the top set-point and parameter r0.
Floor. If functioning with 1 measurement input:
• the output is switched on in cyclical mode, preferably when the top output is off (the parameter c1 establishes the cycle time. The proce­dure given in paragraph 4.4 can be used to set the duration of output switch-on, intended as a percentage of the time established
with parameter c1)
• the cyclical activity is subject to the chamber temperature (chamber
probe), to the work set-point and parameter r0.
If functioning with 2 measurement inputs:
• the output activity depends mainly on the floor temperature (floor
probe), the floor set-point and parameter r6.
Chamber light.
The output is activated in manual mode.
Through the multifunction input it is also possible to activate the out-
put in remote mode.
Airhole.
The output is activated in the following conditions:
• before the conclusion of the cooking timer count (of the time estab-
lished with the parameter c5), for the time established with param-
eter c6
• in manual mode, for the time established for parameter c7.
Steam injection.
The output activity depends mainly on parameter t0.
Through the multifunction input it is also possible to activate the out-
put in remote mode.
Steam generator.
If functioning with 1 measurement input:
• if the steam probe is not enabled, the output is activated in manual
mode
• if the steam probe is enabled, the output is enabled in manual mode,
after which the activity of the same will depend on the temperature
of the steam (steam probe), the steam set-point and parameter t3.
If functioning with 2 measurement inputs, the output is activated in
manual mode.
Alarm.
The output is activated during a temperature alarm.
Through the multifunction input it is also possible to activate the out-
put in remote mode.
Cooking timer.
The output is activated during the cooking timer count.
Acoustics.
The output is activated in the following conditions:
• before the conclusion of the cooking timer count (of the time estab-
lished with the parameter c9), for the time established with param-
eter c4
• during an alarm or an error, with continuous contribution.
On/Stand-by.
The output is activated during the “on” state (see paragraph 3.1).
In spite of the fact that the instrument can manage the 10
utilities stated in this paragraph, there are 6 digital out-
puts available. Make sure that the desired utility is man-
aged by the instrument (see paragraph 2.1).
3 USER INTERFACE
3.1 Preliminary considerations
The following functioning states exist:
• the “on” state (the instrument is powered and on: the regulators can be on)
• the “stand-by” state (the instrument is powered but switched off via software: the regulators are off)
• the “off” state (the instrument is not powered).
Successively, the term “switch-on” means the passage from the stand­by state to the on state. The term “switch-off” means the passage from the on state to the stand-by state. When powered, the instrument re-proposes the state that it was in
when the power supply was disconnected.
3.2 Instrument switch-on/off
To pass from the stand-by state to the on state (and vice versa):
• make sure no procedure is in progress
• press
Through the on/stand-by input it is also possible to pass from the on
state to the stand-by state in remote mode.
To pass from the on to the stand-by state in remote mode:
• activate the on/stand-by input (the instrument remains in the stand-
If the on/stand-by input is active, it will not be allowed to pass from the
stand-by state to the on state by pressing the
3.3 The display
If functioning with 1 measurement input, if the instrument is in the on state:
• the upper part of the display will show the size established with
- if P5 = 0, the display will show the chamber temperature
- if P5 = 1, the display will show the work set-point
• the lower part of the display will show the size established with
- if P6 = 0, the display will show the chamber temperature
- if P6 = 1, the display will show the work set-point (in this case the
- if P6 = 2, the display will show the value of the cooking timer or its
See also paragraphs 3.5 and 3.7. If functioning with 2 measurement inputs, if the instrument is in the on state:
• the upper part of the display will show the size established with
- if P5 = 0, the display will show the top temperature
- if P5 = 1, the display will show the top set-point
for 1s.
by state for the entire duration of input activation).
key.
parameter P5:
parameter P6:
set” LED will be on)
count if the timer is active (in this case the “timer” LED will be on); the value of the cooking timer is displayed in the hours:minutes format.
parameter P5:
Evco S.p.A. • Code 1049326E00 • page 2/6
- if P5 = 2, the display will show the floor temperature
- if P5 = 3, the display will show the floor set-point
• the lower part of the display will show the size established with
parameter P6:
- if P6 = 0, the display will show the top temperature
- if P6 = 1, the display will show the top set-point (in this case the “set”
LED and the “1” LED will be on).
- if P6 = 2, the display will show the value of the cooking timer or its
count if the timer is active (in this case the “timer” LED will be on); the
value of the cooking timer is displayed in the hours:minutes format
- if P6 = 3, the display will show the floor temperature
- if P6 = 4, the display will show the floor set-point (in this case the “set”
LED and the “2” LED will be on).
See also paragraphs 3.5 and 3.7.
If the instrument is in the stand-by state:
• the upper part of the display will be off
• the lower part of the display will be off
• the LED
will be on.
3.4 Temporary setting of the quantity shown by the
upper part of the display during the on state
• make sure no procedure is in progress
• press
and for 1s several times: the upper part of the display
will show one of the labels given in the tables in
paragraph 3.5 for 2 secs, after which it will show
the corresponding value.
Any power supply cut-off causes the display of the quantity estab-
lished with parameter P5 to be restored.
3.5 Learning the quantity shown by the upper part of
the display during the on state
• make sure no procedure is in progress
• press
and : if functioning with 1 measurement input, the
upper part of the display will show one of the
labels given in the following table for 2 seconds:
LABEL MEANING
Pb chamber temperature
SP work set-point
PbS steam temperature
If the steam probe is not enabled (parameter P4 = 0), the “PbS” label
will not be displayed.
if functioning with 2 measurement inputs, the upper part of the dis-
play will show one of the labels given in the following table for
2 seconds:
LABEL MEANING
Pb1 temperature of the top
SP1 top set-point
Pb2 temperature of the floor
SP2 floor set-point
3.6 Temporary setting of the quantity shown by the
lower part of the display during the on state
• make sure no procedure is in progress
• press
and for 1s several times: the lower part of the display
will show one of the labels given in the tables in
paragraph 3.7 for 2 secs, after which it will show
the corresponding value.
Any power supply cut-off causes the display of the quantity estab-
lished with parameter P6 to be restored.
3.7 Learning the quantity shown by the lower part of
the display during the on state
• make sure no procedure is in progress
• press
and : if functioning with 1 measurement input, the
lower part of the display will show one of the
labels given in the following table for 2 seconds:
LABEL MEANING
Pb chamber temperature
SP work set-point
tine value of the cooking timer or its count if the timer is active
PbS steam temperature
If the steam probe is not enabled (parameter P4 = 0), the “PbS” label will not be displayed. if functioning with 2 measurement inputs, the lower part of the dis­play will show one of the labels given in the following table for 2
seconds:
LABEL MEANING
Pb1 temperature of the top
SP1 top set-point
tine value of the cooking timer or its count if the timer is active
Pb2 temperature of the floor
SP2 floor set-point
3.8 Chamber light switch on/off
• make sure no procedure is in progress
• press
Using the multifunction input, it is also possible to cause the same
effect caused by pressing the key
in remote mode.
If the chamber light is not managed by any digital output, pressing the
key will cause the display of the “no” indication for 1s in the lower
part of the display.
3.9 Buzzer silencing
• make sure no procedure is in progress
• press a key (the first time the key is pressed, the associated effect is not caused).
Pressing the key also causes the deactivation of the acoustic output and the buzzer output. Using the multifunction input, it is also possible to deactivate the buzzer, the acoustic output and the buzzer output in remote mode.
4 SETTINGS
4.1 Setting the type of functioning (with 1 measure-
ment input rather than 2)
To access the procedure:
• make sure that the instrument is in stand-by state and that no proce-
dure is in progress
• press
and for 4s: the upper part of the display will show
PA
• press
: the lower part of the display will show the correspond-
ing value
• press
or within 15s to set “743
• press
• press and for 4s: the upper part of the display will show
Pb”.
To modify the type of functioning:
• press
: the lower part of the display will show the correspond-
ing value.
The meaning of the values is the following:
VALUE MEANING
1 functioning with 1 measurement input (default, chamber
probe)
2 functioning with 2 measurement inputs (top probe and
floor probe)
• press
or within 15s
• press
To exit the procedure:
• press
and for 4s.
The modification of the type of functioning does not cause
the configuration parameters default value to be restored.
4.2 Setting the utility managed by the relay K3 and
the relay K6
To access the procedure:
• make sure that the instrument is in stand-by state and that no proce-
dure is in progress
• press
and for 4s: the upper part of the display will show
PA
• press
: the lower part of the display will show the correspond-
ing value
• press
or within 15s to set “743
• press
• press and for 4s: the upper part of the display will show
Pb
• press
or to select “do3” or “do6”.
The label meaning is the following:
LABEL MEANING
do3 utility managed by the third digital output (relay K3)
do6 utility managed by the sixth digital output (relay K6)
To modify the utility managed by an output:
• press
: the lower part of the display will show the correspond-
ing value.
The meaning of the values is the following:
VALUE MEANING
0 not used
1 chamber light
2 steam generator
3 alarm
4 cooking timer
5 acoustics
6 on/stand-by
• press
or within 15s
• press
To exit the procedure:
• press
and for 4s.
4.3.1 Setting the work set-point (only if functioning with
1 measurement input)
• make sure that the instrument is in on state and that no procedure is
in progress
• press
• press
• press
: the lower part of the display will show “SP”, the upper
part the corresponding value and the LED
will flash
or within 15s; see also parameters r1 and r2
3 times or do not operate for 15s: the LED will switch-
off, after which the instrument will exit the procedure.
To exit the procedure in advance:
• do not operate for 15s (any modifications will be saved). It is also possible to set the work set-point via the SP parameter.
4.3.2 Setting the top set-point and the floor set-point (only if functioning with 2 measurement inputs)
To modify the top set-point:
• make sure that the instrument is in on state and that no procedure is
in progress
• press
• press
• press
: the lower part of the display will show “SP1”, the upper
part the corresponding value and the LED
will flash or within 15s; see also parameters r1 and r2 2 times or do not operate for 15s: the LED will switch­off, after which the instrument will exit the procedure.
To modify the floor set-point:
• press
during the modification of the top set-point: the lower part of the display will show “SP2”, the upper part the
• press
• press
corresponding value and the LED
or within 15s; see also parameters r7 and r8 : the LED will switch-off, after which the instrument
will flash
will exit the procedure.
To go back to previous levels:
• press
several times during the procedure.
To exit the procedure in advance:
• do not operate for 15s (any modifications will be saved).
It is also possible to set the top set-point via parameter SP1 and the floor
set-point via parameter SP2.
4.4 Setting the power distributed to the top and the
power distributed to the floor (only if functioning
with 1 measurement input)
To modify the power distributed to the top:
• press
during the modification of the work set-point: the lower
part of the display will show “Po1”, the upper part the
corresponding value and a proportioned number of bars
• press
or within 15s; see also parameters c0 and c1
• non operare per 15 s: the LED
of the LED
will flash
will switch-off, after which the
instrument will exit the procedure.
To modify the power distributed to the floor:
• press
during the modification of the power distributed to the
top: the lower part of the display will show “Po2”, the
upper part the corresponding value and a proportioned
• press
• press
number of bars of the LED
or within 15s; see also parameters c0 and c1
: the LED will switch-off, after which the instrument will
will flash
exit the procedure.
To go back to previous levels:
• press
several times during the procedure.
To exit the procedure in advance:
• do not operate for 15s (any modifications will be saved).
It is also possible to set the power distributed to the top through pa-
rameter Po1 and the power distributed to the floor through param-
eter Po2.
4.5 Setting the configuration parameters
To access the procedure:
• make sure that the instrument is in stand-by state and that no proce-
dure is in progress
• press
and for 4s: the upper part of the display will show
PA
• press
: the lower part of the display will show the correspond-
ing value
• press
• press
• press
or within 15s to set “-19
or do not operate for 15s
and for 4s: if functioning with 1 measurement input,
the upper part of the display will show “SP”; if
functioning with 2 measurement inputs, the
upper part of the display will show “SP1”.
To select a parameter:
• press
or
To modify a parameter:
• press
: the lower part of the display will show the correspond-
ing value
• press
• press
or within 15s
or do not operate for 15s.
To exit the procedure:
• press
and for 4s or do not operate for 60s (any modifica-
tions will be saved).
Cut the instrument power supply off after modification of
the parameters.
4.6 Restore the default value of the configuration pa-
rameters
• make sure that the instrument is in stand-by state and that no proce-
dure is in progress
• press
and for 4s: the upper part of the display will show
PA
• press
: the lower part of the display will show the correspond-
ing value
• press
• press
• press
or within 15s to set “743
or do not operate for 15s
and for 4s: the upper part of the display will show
Pb
• press
• press
or to select “dEF
: the lower part of the display will show the correspond-
ing value
• press
• press
or within 15s to set “149
or do not operate for 15s: the upper part of the display
will show “dEF” flashing for 4s, after which “dEF” will
switch on
• cut the instrument power supply off.
To exit the procedure in advance:
• press
and for 4s during the procedure (i.e. before setting
149”: restore will not be carried out).
Make sure that the default value of the parameters is
appropriate.
5 COOKING TIMER
5.1 Preliminary considerations
The cooking timer allows to start the reverse count of a time.
The count is shown in the lower part of the display; during the count
the “timer” LED is on and the timer output is activated.
Before conclusion of the count (of the time established with parameter
c9) the buzzer and the acoustic output are activated, for the time estab-
lished with parameter c4.
Before conclusion of the count (of the time established with parameter
c5) the airhole is activated, for the time established with parameter c6.
Using the multifunction input, it is also possible to start/interrupt the
cooking timer in remote mode.