ETC ColorSource Spot User Manual

ColorSource™ Spot
Photometry Guide
ColorSource Series
ColorSource Spot
ColorSource Spot - Fresnel Adapter
ETC
ColorSource Spot™ Photometry Guide
ColorSource Series
Throw Distance Multiplier (TDM)
To determine the distance from the center of the beam (Origin) to a certain illuminance level at a particular distance, multiply the desired throw distance by the TDM desired on the Iso-Illuminance diagram.
Throw Distance (TD) x Throw Distance Multiplier (TDM) = Distance from the Origin (DfO) (distance from the center of the beam) Example: 25 feet (TD) x 0.047 (TDM) = 1.175 feet from center of beam (DfO)
Iso-Illuminance Diagram
(Flat Surface Distribution)
10%
50%
% illuminance foot candle or lux
2
ETC
ColorSource Spot™ Photometry Guide
TABLE OF CONTENTS
COLORSOURCE SPOT
5° .................................................4
10° ................................................4
14° ................................................5
19° EDLT ............................................ 5
26° EDLT ............................................ 6
36° EDLT ............................................ 6
50° LT .............................................. 7
70° ................................................7
90° ................................................8
15-30° Zoom Narrow................................... 8
15-30° Zoom Mid .....................................9
15-30° Zoom Wide .................................... 9
25-50° Zoom Narrow.................................. 10
25-50° Zoom Mid ....................................10
25-50° Zoom Wide ................................... 11
ColorSource Series
COLORSOURCE SPOT WITH FRESNEL ADAPTER
ColorSource Spot with Fresnel adapter - Spot................12
ColorSource Spot with Fresnel adapter - Mid . . . . . . . . . . . . . . . . 12
ColorSource Spot with Fresnel adapter - Flood ............... 13
3
ETC
Field Angle
Beam Angle
Field Angle
Beam Angle
0
50000
100000
150000
200000
250000
300000
350000
400000
-5 -2.5 0 2.5 5
Candela
Degrees
X
Y
ColorSource Spot™ Photometry Guide
ColorSource Series
ColorSource Spot 5°
Mode Degree Candela Field
Lumens
Maximum Output 397,563 3,979 3,765 160 24.9
At 3200K 358,269 3,609 3,428 115 31.4
At 5600K 373,500 3,752 3,577 141 26.6
Metric conversions: For meters, multiply feet by 0.3048
For lux, multiply footcandles by 10.76
7.0˚ 7.4˚
Throw Distance (d) 10’
3.0m
Field Diameter 1.3’
0.4m
15’
4.6m
1.9’
0.6m
20’
6.1m
2.6’
0.8m
Illuminance (fc) 3,744 1,664 936 416.0 1
Illuminance (lux) 40,302 17,912 10,075 4,478 10.76
For field diameter at any distance, multiply distance by 0.129 For beam diameter at any distance, multiply by 0.122
Lumens
30’
9.1m
3.9’
1.2m
Beam
Consumption
611.9’
186.5m
Power
Efficacy
Candela Plot
(lpw)
Iso-Illuminance Diagram
(Flat Surface Distribution)
10%
50%
% illuminance foot candle or lux
ColorSource Spot 10°
Mode Degree Candela Field
Lumens
Maximum Output 10° 242,720 4,985 4,582 160 31.2
Regulated 3200K 10° 218,731 4,522 4,172 115 39.3
Regulated 5600K 10° 228,029 4,700 4,354 141 33.3
Metric Conversions: For meters, multiply feet by 0.3048
For lux, multiply footcandles by 10.76
10.7˚ 11.2˚
Throw Distance (d) 10’
3.0m
Field Diameter 2.0’
0.6m
Illuminance (fc) 2,427 1,079 607 269.7 1
Illuminance (lux) 26,126 11,612 6,532 2,903 10.76
For field diameter at any distance, multiply distance by 0.196 For beam diameter at any distance, multiply by 0.187
15’
4.6m
2.9’
0.9m
20’
6.1m
3.9’
1.2m
Lumens
30’
9.1m
5.9’
1.8m
Beam
150.2m
Power
Consumption
492.7’
4
Efficacy
(lpw)
Candela Plot
250000
200000
150000
100000
Candela
50000
0
-7.5 -5 -2.5 0 2.5 5 7.5
Degrees
Iso-Illuminance Diagram
(Flat Surface Distribution)
X
Y
10%
50%
% illuminance foot candle or lux
Loading...
+ 9 hidden pages