Corporate Headquarters  Middleton, Wisconsin, USA  Tel +608 831 4116 Service (Americas)  service@etcconnect.com London, UK  Tel +44 (0)20 8896 1000  Service: (UK) service@etceurope.com Rome, IT  Tel +39 (06) 32 111 683  Service: (UK) service@etceurope.com Holzkirchen, DE  Tel +49 (80 24) 47 00-0  Service: (DE) techserv-hoki@etcconnect.com Hong Kong  Tel +852 2799 1220  Service: (Asia) service@etcasia.com Web: etcconnect.com
© 2018 Electronic Theatre Controls, Inc. 
Product information and
specifications subject to change. 
ETC intends this document to be provided in its entirety.
US Patents
8,384,294 . 8,403,523 . 8,593,074 . 8,633,649 . 8,723,450 . 8,878,455 . 9,041,308
EU Patents 2638781 . 6020110157302
 All other patents pending.
7412M2120-1.7  Rev A  Released 2018-04
Overview
The ColorSource PAR Pearl is an affordable LED fixture that provides a bright, variable white light.
The ColorSource PAR Pearl is UL924 listed as a Directly Controlled Luminaire for use in emergency lighting systems when used with the ETC DMX Emergency Bypass Controller (DEBC).
Note:
Features described in this document require the latest version of software. For information on updating fixture software, see Updating the fixture software on page 12.
ETC Installation Guide
ColorSource PAR Pearl v1.7
ColorSource PAR Pearl v1.7 Page 2 of 16 ETC
Safety
Read the entire manual before using this equipment.
CAUTION:
• Risk of eye injury. Do not stare directly into the light.
• Do not operate in proximity to flammable materials.
WARNING:
Disconnect the fixture from power and DMX and allow it to cool before performing any cleaning and maintenance.
WARNING:
The ColorSource PAR Pearl is a Directly Controlled Luminaire suitable for use in emergency lighting applications in accordance with 2017 National Electrical Code section 700.24 when used with an ETC DMX Emergency Bypass Controller. Equipment intended for this purpose must be properly selected, installed, and maintained so that facility conformance can be obtained. Installation and servicing shall be performed by qualified service personnel.
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
• READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
• Do not use outdoors.
• Do not let power supply cords touch hot surfaces.
• Do not mount near gas or electric heaters.
• Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
• The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
• Do not use this equipment for other than intended use.
• SAVE THESE INSTRUCTIONS
ETC Installation Guide
ColorSource PAR Pearl v1.7
ColorSource PAR Pearl v1.7 Page 3 of 16 ETC
Environment
The ColorSource PAR Pearl operates in ambient temperatures of 0°C–40°C and comes with a variable-speed fan.
Electrical
• Operates between 100V and 240VAC at a frequency of 50/60Hz.
• Maximum power consumption is 135W.
• Up to 9 luminaires (15A max) may be linked via power thru connector (10 luminaires total per circuit) when used with an R20 Relay Module or Unison Echo
®
Relay Panel. Consult breaker trip curves when used
with other equipment. Requires power from a non-dimmable source.
• Inrush:
- 120V: 35A (first half-cycle)
- 240V: 49A (first half-cycle)
Typical power consumption
Note:
The ColorSource PAR Pearl is for indoor use only.
Note:
• Maximum recommended ambient operating temperature: Ta = 40°C (104°F)
• Maximum anticipated external surface temperature at 40°C ambient: Tmax = 80°C (176°F)
• External temperatures after 5 minutes of full­brightness operation at 25°C (77°F) ambient: 33°C (91°F)
• External Temperature (steady state achieved) at 25°C (77°F): 44°C (111°F)
100V 120V 230V
Idle Power/Current 1.7W/0.03A 1.6W/0.03A 1.47W/0.03A
Direct at Full/Current 116.6W/1.17A 114.4W/0.96A 112.3W/0.50A
ETC Installation Guide
ColorSource PAR Pearl v1.7
ColorSource PAR Pearl v1.7 Page 4 of 16 ETC
Installation
Emergency lighting considerations
Luminaires that are used in emergency lighting applications must provide a minimum illumination level over the identified means of egress path in accordance with the Life Safety Code
®
, NFPA 101. A luminaire that is intended to serve this purpose must be mounted at a height where it will not readily be subjected to tampering by unauthorized personnel and where the minimum required illumination level over the egress path can be achieved. The ETC DMX Emergency Bypass Controller that is driving the luminaire upon loss of utility power must be programmed to drive the ColorSource PAR Pearl to full illumination.
Mounting
The ColorSource PAR Pearl ships with a standard yoke for mounting with a C-clamp. An expandable floor stand yoke is available as an optional accessory. Contact your local dealer for more information.
Safety cable
The safety cable (or other approved safety device) must be attached to the fixture. Attachment loops are provided on the rear of the fixture housing. Take care to leave as little slack as possible in the safety cable to avoid catching the yoke of the fixture.
Connectors
• Power: Two powerCON® connectors for power in and thru
• Data (DMX512/RDM): Two five-pin XLR connectors
OR
two RJ45
connectors for data in and thru
Conversion cables are available from ETC. Please contact your ETC customer service representative and request part number W6538 for RJ45 to female XLR or part number W6539 for RJ45 to male XLR.
Note:
This fixture is not Ethernet/data network compatible.
Note:
The ColorSource PAR Pearl is not self terminating. You must terminate the last fixture in line with a 120 Ohm resistor. XLR terminators are not available from ETC.
To purchase an RJ45 terminator, please contact ETC customer service and request part number N4086.
Safety cable attachment loop
ETC Installation Guide
ColorSource PAR Pearl v1.7
ColorSource PAR Pearl v1.7 Page 5 of 16 ETC
Setting up the fixture
1: Plug power cord into the powerCON In connector on the rear of the
fixture.
2: Make any power-thru cable connections prior to applying a power
source.
3: Make any DMX connections, and if the fixture is the last in a DMX line,
terminate the fixture. See
Connectors
on
page 4
.
4: Plug power cord into power source.
Powering up
1: Press any button to wake the display. The display shows the DMX
address. See
Setting the DMX address
on
page 6
.
2: Press the Mode button to access the Presets menu. See
Setting presets
on
page 10
.
Adjusting the tilt
The fixture can be tilted up and down and rotated (panned) as needed.
1: Loosen, but do not remove the yoke locking knob. 2: Tilt the fixture to the desired angle. 3: Tighten the yoke locking knob.
User interface
The user interface allows you to set the start address of the fixture, access the stand-alone presets, and set the DMX control mode.
• After 5 seconds of inactivity when DMX is present, the display goes dark.
• The DMX address will blink when no DMX is present and a preset or sequence is not active. The inactivity time-out is disabled while in a data loss state.