Ergotron SV42-6101-1 User Manual

0 (0)

User Guide

StyleView® SV42

Electronic Medical Records (EMR) Cart

with Laptop Mount

StyleView powered carts provide electrical AC power for mobile point of care computing equipment in a healthcare environment. The carts are not intended to power medical products or devices. Outlets are provided to power information technology equipment only such as computer equipment and computer peripherals.

Features & Specifications....................................................

3

Set-up ............................................................................

4 - 13

Adjustment .....................................................................

12

Battery Charge/Discharge ..............................................

13

Change Fuse (5 Amp) and Reset Circuit Breakers ............

14

Change Power System Batteries.................................

1516

Cart Storage (long term/short term).................................

17

Ergonomics .........................................................................

18

Maintenance & Safety ................................................

18 - 21

Dimensions .........................................................................

22

For local customer care phone numbers visit: http://contact.ergotron.com

For the latest User Installation Guide and StyleLink Software Download please visit: www.ergotron.com

User's Guide - English Guía del usuario - Español

Manuel de l’utilisateur - Français Gebruikersgids - Deutsch Benutzerhandbuch - Nederlands

Guida per l’utente - Italiano Användarhandbok - svenska

:

:

ENGLISH

888-24-171-G-01 rev. K • 02/16

1/22

WARNING

AVERTISSEMENT

14mm (9/16”)

IMPACT HAZARD!

MOVING PARTS CAN CRUSH AND CUT.

Failure to heed this warning may result in serious personal injury or property damage!

Minimize Lift Tension BEFORE:

Removing Mounted Equipment, Shipping Cart, Storing Cart.

DANGER D’IMPACT !

LES PARTIES EN MOUVEMENT PEUVENT ÉCRASER ET COUPER.

Il existe un risque de blessure corporelle ou d’endommagement matériel en cas de non respect de cet avertissement.

Minimisez la tension d’élévation AVANT :

de retirer l’équipement fixé, d’expédier le chariot, de stocker le chariot

www.ergotron.com

826-501

29 °C

50 °C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEAD

 

 

86 °F

122 °F

 

 

 

 

10 °C

-20 °C

 

 

 

 

 

 

 

 

50 °F

 

 

 

 

 

 

 

 

- 4 °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relative

Relative

BATTERY

 

 

Humidity 5-95% rH

Humidity 5-95% rH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

Range

 

 

 

 

 

 

 

 

Operational Storage

This Class A digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

FCC Compliance Statement

The cart has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Changes or modifications not expressly approved by Ergotron, Inc. could void the user’s authority to operate the equipment.

Please contact Ergotron for complete EMC compatibility information.

IMPORTANT! This product will need tension adjustments once installation is complete. Make sure all equipment is properly installed on the product before attempting range of motion or tension adjustments. Any time equipment is added or changed on this product resulting in a different mounted weight, you should repeat the adjustment steps to ensure safe and optimum operation. This product should move smoothly and easily through the full range of motion and stay where you set it. If movement is difficult or the product does not stay where you set it, follow the adjustment instructions to loosen or tighten the tension to create a smooth, easy motion. Depending on your product and the adjustment, it may take many turns to notice a difference.

ENGLISH

Components

 

 

 

 

A

B

C

 

1

1x

 

2x

Tools Needed

 

 

 

 

2

1x

1x

 

 

 

 

 

 

2x

1x

 

14mm (9/16")

3

1x

 

 

 

 

M4x12mm

 

 

 

 

4

1x

1x

 

 

5

1x

 

2x

 

 

1x

 

 

 

 

 

 

6

1x

9x

2x

 

 

1x

1x

1x

 

7

 

 

 

2x

M4 x 8mm

 

 

 

 

 

 

 

 

2/22

 

 

 

888-24-171-G-01 rev. K • 02/16

Features & Specifications

Part Number

Power System

SV42-6101-1

Input: 120VAC/60 Hz, 5.1A;

 

Output: 120VAC/60 Hz, 400VA, 300W.

 

• The cart and power system are certified to UL 60601 and CAN/CSA-C22.2 601.1-M90

 

 

SV42-6101-2

Input: 230V~/50 Hz, 2.7A;

SV42-6101-3

Output: 230V~/50 Hz, 400VA, 300W.

SV42-6101-C

• The cart and power system are compliant with EN 60601-1.

 

SV42-6101-7

Input: 220V~/60 Hz, 2.7A;

SV42-6101-8

Output: 220V~/60 Hz, 400VA, 300W.

13

 

1

 

2

 

4

 

8

7

3/10

 

17

 

18

12

9

17

16

5

 

 

6

 

11

 

 

15

 

 

14

1.Worksurface

2.User Interface

3.Secure storage for open laptop

4.Front Handle

5.Height Adjustment Brake

6.USB Hub connects keyboard and mouse USB cables

7.Keyboard tray slides out, tilts and allows for right or left mousing with attached mouse holder

8.Keyboard Light under Front Handle

9.Keyboard Light Switch

10.Cable Management and Storage for excess cables and power supplies

11.Storage Basket and Rear Handle

12.Front Locking Casters

13.Laptop Screen Holders

14.Quick Reference Card

15.Power Cord Hooks

16.Scanner Holder

17.Antimicrobial coating on worksurface and wrist rest

18.Power System

The StyleView AC Power System allows your power supply to travel with the cart. The Power System is integrated in the base of the cart and comes standard with 2 batteries, power module, User Interface (UI), outlet box and power cord.

User Interface (UI): Allows power system output to be turned on or turned off, monitors battery charge remaining, and provides low battery charge audible alarm.

Two 33 Ah Sealed Lead Acid, Absorbed Glass Mat, 12VDC batteries.

The minimum operational temperature is 10°C (50°F) and the maximum operational temperature is 29°C (86°F). The recommended humidity range for operation is 5-95% rH.

The recommended cart storage temperature is 15°C (59°F). At this temperature, the battery’s age-related capacity loss is minimized. The minimum storage temperature is -20°C (-4°F) and the maximum storage temperature is 50°C (122°F). The recommended humidity range for storage is 5-95% rH.

ENGLISH

20"

(508 mm)

Weight Capacity

Worksurface <5 lbs (2.3 kg)

 

Laptop Compartment <10 lbs (4.5 kg)

12˚

<3 lbs (1.4 kg)

888-24-171-G-01 rev. K • 02/16

3/22

Set-up

1 a

Release Brake to move riser.

CAUTION! Completely release brake engagement before raising or lowering the cart. Raising or lowering the cart with the brake partially engaged may cause product damage.

b

ENGLISH

c

d

2 a

b

c

4/22

888-24-171-G-01 rev. K • 02/16

Set-up

3 Plug in power cables.

If you do not have power outlets located here, then follow steps 'a' - 'd' to route power cables.

WARNING! Connecting electrical equipment to the outlet effectively leads to creating a

medical system and the result can be a reduced level of safety.

4

a

Route power cable down along tower.

b - d

6' (1.8 m)

Power cables need to be 6' (1.8 m) long.

ENGLISH

888-24-171-G-01 rev. K • 02/16

5/22

Ergotron SV42-6101-1 User Manual

Set-up

b

c

1x

1x

WARNING! Connecting electrical equipment to the outlet effectively leads to creating a medical system and the result can be a reduced level of safety.

d

ENGLISH

4 a

b

b

c

6/22

888-24-171-G-01 rev. K • 02/16

Set-up

5 a

1x

1x

b

1x

 

1x

 

6 a

1x

 

ENGLISH

bConnect Keyboard and Mouse to USB Hub

USB (Type A)

USB (Type A)

 

NOTE: Bar Code Scanner should be connected directly to computer USB port.

DO NOT connect Bar Code Scanner to the USB Hub.

888-24-171-G-01 rev. K • 02/16

7/22

Loading...
+ 15 hidden pages