Scanner Specifications
ES-800C
Scanner main unit
Power cable
Document cover
Carriage (at home p
Document table
\
POWEli switch
Option control connector
User’s Guide
‘RESET switch
Transportation screw
/
Image Sample
ERROR light
READY light
POWER light
Scanner type:
Photoelectric
device:
Effective pixels:
Maximum
document size:
Scanning
resolution:
Output resolution:
Color separation:
Reading sequence:
Size:
Image data:
Gradation:
Brightness:
Halftoning process:
Flatbed, color/monochrome
CCD line sensor
3400 dots by 4680 dots at 400 dpi, 100%
216 mm by 297 mm
(8.5 inches by 11.7 inches)
US letter size or A4
400 dpi
50, 72,
75,80,90,100,120,133,144,
150,160,175,180,200,216,240,300,320,
360,400,480,600
and 800 dpi.
Values above 400 through software
interpolation.
By switching light sources (G, R, B)
Monochrome mode:
One-time scanning (Dropout color
selectable from Green, Red, or Blue.)
Color page sequence mode:
Three-time scanning (G, R, B)
Color line sequence mode:
One-time scanning (G, R, B)
50% to 200% in 1% steps.
8 bits per pixel per color maximum
8 bits per pixel per color maximum
7 levels
Enable/disable selectable.
3 halftoning modes (A, B, and C) and
4 dither patterns (A, B, C, and D) for
bi-level data
(Halftoning mode A only in color line
sequence mode)
(2 downloadable dither patterns)
Ground termina
Scanners
SCSI ID rotary switch
SCSI interface connectors
Gamma correction:
Color correction:
Interface:
Light source:
Reliability:
11
&I92
2 for CRT display
3 for printer
1 for user defined
1 type for CRT display
3 types for printer output, available in
color line sequence mode only
Bidirectional parallel and SCSI
Noble gas fluorescent lamps (3 lamps)
Main unit: MCBF 100,000 cycles of
carriage movement
ES-800C-1
ES-800C
Dimensions and
weight:
Width: 368 mm (14.5 inches)
Depth: 577 mm (22.5 inches)
Height: 161 mm (6.5 inches)
Weight: about 12 kg (26 lbs)
Electrical Specifications
Voltage:
Frequency:
Power
consumption:
Insulation
resistance:
120 VAC,
49.5
Approx. 50 W (max)
20 m between AC power line and
chassis at 500 VDC
to
flO%
60.5
Hz
Environmental Conditions
Temperature:
Humidity:
Operating
conditions:
Note:
Specijcations are subject to change without notice.
Operation: 40” F to 95” F (5” C to 35” C)
Storage: 10’ F to 150” F (-20” C to 60” C)
Operation: 30% to
condensation
Storage: 20% to
condensation
Ordinary office or home conditions.
Extreme dust should be avoided.
Operation under direct sunlight
or near a strong light source should be
avoided.
85%,
SO%,
without
without
Parallel Interface Specifications
Interface type:
Data format: S-bit parallel
Synchronization:
Handshaking:
Logic level:
Connector type:
Connector pin
arrangement:
Bidirectional parallel interface
By external strobe pulse
By ACKNLG and BUSY signals
Input/output data and interface control
signals are TTL level compatible
36-pin
Centronics@
18
type connector
SCSI Specifications
Interface type:
Function:
Logic level:
Electrical standard: As per ANSI X3.131-1986
ID Setting:
Connector type:
ANSI X3.131-1986 standard
The following functions are included.
BUS FREE phase
ARBITRATION phase
SELECTION/ RESELECTION phase
COMMAND phase
(Logical Unit number is fixed to 0 and
command link function is not supported.)
DATA phase
Data in phase
Data out phase
STATUS phase
MESSAGE phase
(Includes MESSAGE IN phase and
MESSAGE OUT phase)
ATTENTION condition
RESET condition
TTL level compatible
Selectable from 0 to 7 with the rotary
switch.
(8 and 9 should not be selected.)
Two 50-pin connectors
Scanning Functions
Scanner settings
The table below summarizes the scanner functions and the
settings available on your scanner. All of these functions are
controlled by the software commands from your scanner
software.
Function
Resolution
Size
Gamma correction
Color correction
Available settings
23 settings from 50 to 800 dpi
50% to 200% at 1% step
Color line sequence mode, color page sequence
mode and monochrome mode (dropout color
4 dither patterns
5 settings for output devices
4 settings for output devices
36
ES-800C-2 11/2/92