The following tools may be required:
YG-4000-SS / YG-4001-SS – Single Outdoor LED wall fittings.
INSTRUCTION MANUAL
This product is only suitable for connection to a 240V~50Hz supply.
It is recommended that this light is installed by a qualified electrician in accordance with current IEE Wiring
Regulations and Building Regulations (Part P).
The light fitting should be connected to a lighting circuit protected by a 5 amp fuse (or a 6 amp miniature
circuit breaker).
This light has an IP44 (splash proof) rating suitable for use outdoors.
Run supply wire from a 5-amp electrical supply using double insulated 3-core cable of type H05RN-F 1.0mm
(not supplied) to selected site, ensuring it is adequately protected through the full length of the cable run, it
must come out of the flat surface of the mounting surface in line with the entry to the fitting.
Except where installed in a conduit or duct , which provides equivalent protection against mechanical damage,
a cable buried in the ground shall incorporate an earthed armour or metal sheath or both, suitable for use as a
protective conductor, or be of insulated concentric construction. Buried cables shall be marked by cable
covers or a suitable marking tape. Buried conduits and ducts shall be suitably identified. Buried cables,
conduits and ducts shall be at a sufficient depth to avoid being damaged by any reasonably foreseeable
disturbance of the ground.
This product contains breakable parts – be careful during handling and maintenance to avoid breakage.
The shade can become hot in use. Switch off and allow 10 minutes to cool before cleaning.
If any part of the (LED) housing is broken or cracked then it cannot be replaced and the fittings must not be
used - as the water ingress protection has been compromised.
This fitting uses non-replaceable LED`s.
We recommend that you do not stare directly into the light beam (of LED`s).
IMPORTANT: To achieve maximum corrosion resistance the surface of the Stainless Steel must be kept clean.
Surface contamination and the formation of deposits are critical factors which may lead to drastically reduced
life. An example is salt deposits from marine conditions. Cleaning with soap or a mild detergent and warm
water followed by a careful clean water rinse and finally wiping dry is usually adequate for most S/S items
used in the domestic environment. Care must be taken to turn off the mains supply until the cleaning process
has been completed and the fitting is completely dry.
If any modification is made it will invalidate the warranty and may render the product unsafe.
Before you start
Please read these instructions carefully before fitting your new light and retain for reference.
Switch off the mains supply and remove the appropriate fuse or switch off the appropriate circuit breaker
before commencing installation.
Ensure that no one else has access that would enable the supply to be inadvertently reconnected.
Check the packaging and make sure that you have all the required parts.
Follow each assembly step in order to prevent incorrect assembly
Make sure all screws / nuts, including electrical connections etc are fully tightened before use.
This product must not be connected to a dimmer control.
Wall light with non-replaceable LED modules, and
bracket.
Terminal connection block.
Selection of cross and flat head screwdrivers.
Electric drill and assorted drill bits.
Wire strippers.
Electrical insulation tape.
2

Assembly / user instructions
YG-4001-SS- Diagram B
Diagram C
These assembly diagrams are intended as a guide – if in doubt consult a qualified electrician.
YG-4000-SS - Diagram A
1. Determine the position of your light
fitting taking into account the exit
position of the cable. Ensure that
the mounting surface is solid,
preferably a brick or block wall and
ensure that there are no other
cables or pipes beneath the
surface. Use appropriate fixings.
Wall plugs and screws as supplied
are shown here.
YG-4000-SS – Diagram A.
2.
Separate the plastic back plate
from the fitting by removing the two
domed nuts / washers (1) on the
front of the fitting. Leave the
threaded (2) bolts in the back plate.
The internal terminal block (3) can
be removed from its mounting
position inside the back plate to
ease fitment of the back plate. Use
the back plate as a template to
mark the screw holes. Make sure
the back plate is correctly aligned.
Use a sharp object such as a
screwdriver to pierce the rubber
grommet in the back plate. Feed
the incoming cable (4) through the
rubber grommet and attach the
back plate to the wall. Do not over
tighten as this could damage the
back plate.
3. YG-4001-SS – Diagram B.
Remove the wall bracket (5) by
removing the 2 screws (6). Retain
for re-use. Use the bracket as a
template to mark the screw holes.
Make sure the bracket is correctly
aligned and secure to the surface.
Remove the lid (7) from the
terminal block housing.
4. Diagram C. Connect the house
wiring to the internal terminal block
(and replace the terminal cover in
the YG-4001-SS model). NOTE:
These are Class I fittings and
must be earthed. See wiring
details.
5. Place the fittings over the back
plate / bracket and secure.
6. Turn on the power and test.
Endon Lighting
LS9 0SE
20150807