The following tools may be required:
PL-LEDG9 Range- 2 light wall brackets.
INSTRUCTION M ANUAL
These products are only suitable for connection to a 240V~50Hz supply in accordance with current
IEE wiring Regulations and should be installed in accordance with local Building Regulations and
are for Domestic wall use only. They are not suitable for bathroom use.
The light fittings should be connected to a lighting circuit protected by a 5 amp fuse (or a 6 amp
miniature circuit breaker).
If in doubt we recommend you contact a qualified electrician. Before installing your light fitting
always:
Switch off the mains supply and remove the appropriate fuse or switch off the appropriate circuit
breaker before commencing installation.
Ensure that no one else has access that would enable the supply to be inadvertently reconnected.
Never fit bulbs of a higher wattage or of a type other than those specified on the label as this may
cause overheating and damage the fitting.
These fittings should only be used with G9 led bulbs (as supplied) and, as with all led`s, we
recommend that you do not stare into the (led) beam.
Be careful during handling and maintenance to avoid breakage or damage to the fitting.
The bulbs become hot during use so please switch off and allow 10 minutes to cool before
adjusting, replacing bulbs or cleaning the fitting.
Clean with a dry cloth only. Do not use liquid or abrasive cleaners on this product.
If any modification is made it will invalidate the warranty and may render the product unsafe.
Before you start
Please read these instructions carefully before fitting your new light and retain for reference.
Make sure that there are no pipes or cables beneath the mounting surface.
Check the packaging and make sure that you have all the required parts.
Follow each assembly step in order to prevent incorrect assembly.
Make sure all screws / nuts, including electrical connections etc are fully tightened before use.
LED bulbs cannot (generally) be controlled by a dimmer.
Light fitting and mounting bracket.
Terminal connection block(s).
G9 led bulbs
.
Selection of cross and flat head screwdrivers.
Electric drill and assorted drill bits.
Wire strippers.
1

Assembly/ User Instructions
These assembly diagrams are intended as a guide – if in doubt consult a qualified electrician.
1. Decide on the position of
your light fitting. Ensure there
is a solid mounting surface,
preferably a brick or block
wall and ensure that there
are no cables or pipes
beneath the surface. If the
wall is timber frame and
plasterboard then please use
appropriate fixings. Wall
plugs are shown here –
Diagram A. Ensure the
fixings used can support the
weight of the wall light.
2. Remove the fixing bracket, by
undoing the 2 back plate
/bracket screws (1), retain
these for re-use.
3. Use the fixing bracket, as a
template to mark the screw
holes. Make sure the bracket
is horizontal. Fix the bracket
to the wall – the use of plugs
(2) and screws (3) are shown
here.
4. Diagram B. Support your
fitting and connect the house
wiring to the terminal block
(4). NOTE: This is a Class I
fitting and must be earthed
– see wiring details.
5. Re-position the fitting over
the wall bracket and secure
with the 2 back plate /
bracket screws (1), removed
in 2 above. Make sure that all
the internal cables and
connections are inside the
back plate taking care not to
trap or strain the internal
cables.
6. Fit the LED bulbs (5) into the
lamp holders.
NOTE; Never fit bulbs of a
higher wattage, or of a type
other than those specified
on the label (as these may
cause overheating and
damage the fitting).
7. Turn on the power and test.
Endon
LS9 0SE
20150324
2