Emerson Process Management Wireless Gateway 1420 User Manual

Quick Installation Guide
Step 1: Initial Connection for Configuration
Step 2: Basic Security and Time Configuration
Step 4: Mount and Connect the 1420
Star t
End
00825-0100-4420, Rev CA June 2007
1420 Wireless Gateway
1420 Wireless Gateway
¢00825-0100-4420[¤
Quick Installation Guide
IMPORTANT NOTICE
WAR NI NG
WAR NI NG
IMPORTANT NOTICE
Emerson Process Management Rosemount Division
8200 Market Boulevard Chanhassen, MN USA 55317 T (US) (800) 999-9307 T (Intnl) (952) 906-8888 F (952) 949-7001
Rosemount Temperature GmbH
Frankenstrasse 21 63791 Karlstein Germany T 49 (6188) 992 0 F 49 (6188) 992 112
Emerson Process Management Asia Pacific Private Limited
1 Pandan Crescent Singapore 128461 T (65) 6777 8211 F (65) 6777 0947 / (65) 6777 0743 Enquiries@AP.EmersonProcess.com
00825-0100-4420, Rev CA
1420 Wireless Gateway
© 2007 Rosemount Inc. All rights reserved. All marks property of owner.
This installation guide provides basic guidelines for the 1420 Wireless Gateway. It does not provide instructions for detailed configuration, diagnostics, maintenance, service, troubleshooting, or installations. Refer to the 1420 Wireless Gateway reference manual (document number 00809-0100-4420) for more instruction. The manual and this QIG are also available electronically on www.rosemount.com.
Explosions could result in death or serious injury:
Installation of this device in an explosive environment must be in accordance with the appropriate local, national, and international standards, codes, and practices. Please review the Hazardous Locations Certifications for any restrictions associated with a safe installation.
Electrical shock can result in death or serious injury
• Avoid contact with the leads and terminals. High voltage that may be present on leads can cause electrical shock.
June 2007
Explosion Hazard
Do not disconnect equipment when a flammable or combustible atmosphere is present.
The 1420 Wireless Gateway should be installed before installing any other wireless devices. This will result in a simpler and faster network installation.
Physical Device Revision 1.0
Web Server Revision 3.0.8
Network Revision 1.0
2
Quick Installation Guide
STEP 1: INITIAL CONNECTION FOR CONFIGURATION
00825-0100-4420, Rev CA June 2007
To configure the 1420 Wireless Gateway, a local connection between a PC/laptop and the 1420 Wireless Gateway must be established.
NOTE:
If a PC/laptop from another network is used, carefully record the current IP address and other settings so the PC/laptop can be returned to its original network when configuration of the 1420 is finished.
Perform the following steps to establish a local connection with the 1420 Wireless Gateway:
1. On the PC/laptop, install the Java Plug-in found on the CD provided with the 1420. The Plug-in can also be found at http://java.com/
2. Under Network Connections:
a. Select Local Area Connection b. Right click to select Properties.
1420 Wireless Gateway
3
Quick Installation Guide
+ +
+
+
+
-
-
-
-
-A B
S S
S
S
S
24 V DC24 V DC
Power InputPower Input
ModbusModbus
Not UsedNot Used
Not UsedNot Used
Not UsedNot Used
Not UsedNot Used
CaseCase
(Covered)(Covered)
S
POEPOE
P2P2 P1P1
P1 Ethernet Receptacle
Crossover Cable
PC/Laptop
00825-0100-4420, Rev CA
1420 Wireless Gateway
c. Select Internet Protocol (TCP/IP), then click the Properties button d. Select the Use the following IP address button and set the IP address to
192.168.1.12
e. Set the Subnet Mask to 255.255.255.0
f. Select OK for each of the settings windows that have opened.
3. Using the supplied crossover Ethernet cable, attach your PC/laptop to the 1420’s P1 Ethernet Receptacle (far right Ethernet receptacle).
June 2007
WARNING
Do not connect to the P3 Power Over Ethernet (POE) port. This port supplies power and could potentially damage the PC/laptop.
4
Quick Installation Guide
00825-0100-4420, Rev CA June 2007
4. Open a standard web browser (Internet Explorer, Mozilla Firefox or similar).
5. Uncheck proxies (Tools>Internet Options>Connections>LAN Settings)
6. Access the 1420’s default web page at https://192.168.1.10
1420 Wireless Gateway
a. Log on as User: admin b. Password: default
5
1420 Wireless Gateway
c. Click Yes to proceed through the Security Alert
The 1420 Home Page will appear as shown below
Quick Installation Guide
00825-0100-4420, Rev CA
June 2007
6
Quick Installation Guide
STEP 2: BASIC SECURITY AND TIME CONFIGURATION
00825-0100-4420, Rev CA June 2007
To configure the basic security of the 1420 Wireless Gateway, perform the following steps.
1. Navigate to Setup>Security>User Accounts
2. Set and confirm new passwords for each of the access levels
3. Click Submit
4. Navigate to Setup>Time
1420 Wireless Gateway
5. Select method and click Submit
7
Quick Installation Guide
STEP 3: BASIC ETHERNET OR SERIAL CONFIGURATION
00825-0100-4420, Rev CA
1420 Wireless Gateway
June 2007
To configure the 1420 for an Ethernet Network:
Table 2: Ethernet Communication Settings on page 15 is available to assist in recording the necessary information.
1. Determine 1420 Ethernet Port for connecting to Ethernet Network
If using a wired connection, use Port 1 (P1)
IT/Process Control Network Administrator or Technician can provide the following:
a. 1420 fixed IP Address or DHCP Host Name b. Netmask (Subnet Mask) c. Gateway
BEST PRACTICE:
Keep these values in a secure location not accessible by unauthorized personnel.
2. Configure 1420 Ethernet IP settings
a. Access the 1420 with Administrator access b. Navigate to Setup>Internet Protocol>Address
c. Enter configuration information determined above
3. To complete configuration without a firewall, click Submit and proceed with 1420 Restart when prompted.
8
Quick Installation Guide
STEP 3 CONTINUED...
00825-0100-4420, Rev CA June 2007
1420 Wireless Gateway
To configure the 1420 for a Serial connection:
Table 4: Serial Communication Settings on page 15 is available to assist in recording the necessary information.
1. Configure 1420 Serial Communication Settings
a. Access the 1420 Web Interface with Administrator access b. Navigate to Setup>Modbus>Communication c. Click Enable Modbus
d. Configure the 1420 Modbus Communication settings to match the Host Modbus
settings
NOTE:
Modbus communications will fail if they are not configured identically on the Host and the 1420.
e. Click Submit and proceed with restart
2. When configuration is completed, disconnect the PC/laptop from the 1420 and return the PC/laptop to its previous network settings.
9
1420 Wireless Gateway
STEP 4: MOUNT AND CONNECT THE 1420
1.8 m (6 ft.) Strain
Relief
Integral Antenna with the 1420 on a Mast
The optimal installation of the 1420 Wireless Gateway is on a pole approximately 1.8 meters above the top of the exterior wall of a building. The following hardware and tools are needed:
• Pipe mount with holes spaced 3.06 inches (78 mm) apart horizontally and 11.15 inches (283 mm) apart vertically.
• Two 3.06 inch (78 mm) by
1
/2 inch wrench
Mount the gateway by doing the following:
1. Insert one U-bolt around the pipe and through the top mounting holes of the pipe mount and the 1420, and another U-bolt through the bottom mounting holes of the pipe mount and the 1420.
1
2. Using a to the U-bolts and tighten.
BEST PRACTICE
When mounting outside, best practice is to run the Serial or primary Ethernet cable (P1) directly to the Information System. Use conduit and/or strain relief as necessary.
BEST PRACTICE
When installing cable/conduit, run an ethernet connection from 1420 port P2 to a convenient location indoors (if the 1420 was ordered with Output Code 2). This will simplify future configuration changes.
/2 inch socket-head wrench, fasten the nuts
5
/16 inch U-bolts
Quick Installation Guide
00825-0100-4420, Rev CA
June 2007
10
Quick Installation Guide
STEP 4 CONTINUED...
+
+
+
-
AB
S
S
S
S
24 V DC
Power Input
Serial
Modbus
Not Used
d
d
Not Used
Case
(Covered)
S
POE
P2
P1
(Secondary)
(Primary)
00825-0100-4420, Rev CA June 2007
1420 Wireless Gateway
Connect to Information System
1. Wire the 1420 Primary Ethernet output or Serial Output connection to the Host System Ethernet or Serial input connections.
2. For Serial connections, connect A to A, B to B and make sure all terminations are clean and secured to avoid wiring connection problems.
Figure 1. 1420 Terminal Block Diagram
Not Use
-
Not Use
BEST PRACTICE
Typically, twisted shielded pair cable is used to wire the Serial connection. Standard practice is to ground the shield on the Serial Host side and leave the shield floating on the 1420 side. Be sure to insulate the 1420 shield to avoid grounding issues.
NOTE:
In most systems, A = Tx + and B = Rx -. In some systems, this is reversed. For 4-wire systems, see Figure 2.
Figure 2. Typical Full Duplex (4-wire) to Half Duplex (2-wire) Conversion Diagram
Tx +
Rx +
Tx + = (A)
Tx -
Rx -
Confirm wiring configuration with host system documentation.
Supply Power
After mounting is complete supply power to the 1420 according to the following steps:
1. Ground the 1420 using suitable grounding methods. There is a case ground lug located near the terminal block, and an external ground lug located near the conduit entries on the bottom of the housing.
2. Connect the 24 V DC power wiring to the Power Input terminals in the 1420. The 1420 requires 500 mA of current. (see Terminal and Integration Diagram on page 14)
3. Close the terminal cover and tighten securely.
BEST PRACTICE
Use an uninterruptible power supply (UPS) to ensure that the network is still functional should there be a loss of power.
Rx - = (B)
11
Quick Installation Guide
PRODUCT CERTIFICATIONS
00825-0100-4420, Rev CA
1420 Wireless Gateway
June 2007
Approved Manufacturing Locations
Rosemount Inc. – Chanhassen, Minnesota, USA
Telecommunication Compliance
All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage. To see which countries our devices have received certification for use in, see www.rosemount.com/smartwireless.
European Union Directive Information
The EC declaration of conformity for all applicable European directives for this product can be found on the Rosemount website at www.rosemount.com. A hard copy may be obtained by contacting your local sales representative.
ATEX Directive (94/9/EC)
Emerson Process Management complies with the ATEX Directive.
Electro Magnetic Compatibility (EMC) (2004/108/EC)
EN 61326-1: 1997 with amendments A1, A2, and A3– Industrial
Radio and Telecommunications Terminal Equipment Directive (R&TTE)(1999/S/EC)
Emerson Process Management complies with the R&TTE Directive
FM Ordinary Locations Approval
The 1420 Wireless Gateway has been evaluated and approved by FM for ordinary locations.
CE EMC Marking
Compliance with European Union EMC
Hazardous Location Certifications
North American Certifications
N5 FM Division 2
Certificate Number: See Certificate Nonincendive for Class I, Division 2, Groups A,B,C, and D; Dust Ignitionproof for Class II,III, Division 1, Groups E,F, and G; Indoor/outdoor locations; NEMA Type 4X Temperature Code: T4 (-40°C < T
< 60°C)
a
12
Quick Installation Guide
00825-0100-4420, Rev CA June 2007
1420 Wireless Gateway
Canadian Standards Association (CSA)
N6 CSA Division 2 & Dust Ignitionproof
Certificate Number: See Certificate Suitable for Class I, Division 2, Groups A,B,C,D; Dust Ignitionproof for Class II, Groups E,F, and G; Suitable for Class III Hazardous Locations. Install per Rosemount drawing 01420-1011. Temperature Code: T4 (-40°C < T
< 60°C)
a
CSA Enclosure Type 4XEuropean Certification
European Certification
N1 CENELEC Type n (ATEX)
See note below Certificate Number: See Certificate ATEX Marking: Ex II 3 G EEx nA nL IIC T4 (-40°C < T
< 60°C)
a
ND ATEX Dust Ignition-proof Approval
Certificate Number: See Certificate Ex tD A22 IP66 T135 (-40 °C< Ta < +60 EEx nA nL IIC T4 (-40°C < T
< 60°C) II 3D
a
Vmax = 28V
IECEx Certification
N7 IECEx Type n
See note below Certificate Number: See Certificate Ex nC IIC T4 (-40°C =< T Rated Voltage: 28V
NF IECEx Dust Ignition-proof Approval
Certificate Number: See Certificate Ex tD A22 IP66 T135 (-40°C < T Vmax = 28V
CONDITIONS OF INSTALLING N1 AND N7:
The Apparatus is not capable of withstanding the 500V insulation test required by Clause 9.4 of EN 60079-15: 2005. This must be taken into account when installing the apparatus.
<= +60°C)
a
a
< 60°C)
13
1420 Wireless Gateway
++
+
+
+
-
-
-
-
-AB
SS
SS
24 V DC
Power Input
Modbus
Not Used
Not Used
Not Used
Not Used
Case
(Covered)
S
POE
P2
P1
(Secondary) (Primary)
Modbus TCP
AMS
OPC Application
Serial
Serial Input
Card
Remote
1420 HMI
DCS/PLC
HMI
DCS / PLC
Local
1420 HMI
For P2 and POE connectivity options, see the
1420 Wireless Gateway Manual, document
number 00809-0100-4420.
Figure 3. Terminal and Integration Diagram
Quick Installation Guide
00825-0100-4420, Rev CA
June 2007
14
Quick Installation Guide
00825-0100-4420, Rev CA June 2007
Table 1. Ethernet Port Locations
Settings Location
1420 Ethernet Port P1 Information System Switch or Access Point Switch or Access Point Ethernet Port
Table 2. Ethernet Communication Settings
Setting Value Options
Use Fixed IP or DHCP? Fixed or DHCP Fixed IP Address or DHCP
Host Name Netmask (Subnet Mask) YYY.YYY.YYY.YYY Gateway ZZZ.ZZZ.ZZZ.ZZZ
Table 3. Serial Connectivity Locations
Locations
Serial Card Location Serial Card ID Serial Card Termination A (Tx +) Serial Card Termination B (Rx -)
Table 4. Serial Communication Settings
Setting Va lue Options on 1420 (Default in Bold)
Modbus Slave Address 1 - 247 Baud Rate 9600, 19200, 38400, 57600 Parity None, Even, Odd Stop Bits 1, 2 Response Delay Time 0 ms, Configurable in ms Unmapped Register Read
Response
Unmapped Register Write Response
Write Behavior Synchronous, Queued, Most
Floating Point Representation Float, Round (Integer), Scale Use Swapped Floating Point
Format Incorporate Value’s
Associated Status as Error? Value Reported for Error NaN, +Inf, -Inf, *Other* *Other* Value Reported for
Error
1420 Wireless Gateway
XXX.XXX.XXX.XXX or XXXXXXX
Zero, Illegal Data
OK, Illegal Data Address
Current
Yes, No
Yes, No
32767, (Any Integer)
15
1420 Wireless Gateway
Quick Installation Guide
00825-0100-4420, Rev CA
June 2007
16