EMERSON LPT80 Service Manual

Embedded Power for Business-Critical Continuity
LPT80 Series
80 Watts
Special Features
• Power Factor Correction
• EN61000-3-2 compliant
• Universal input
• Remote sense on outputs 1 (& 2 for LPT81)
• Power fail and remote inhibit
• Wide range adjustable on outputs 1 (& 2 for LPT81)
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
Total Power: 55 - 85 Watts Input Voltage: 85-264 Vac
120-370 Vdc
# of Outputs: Tr ip le
Electrical Specifications
Safety
Input
Input ra nge: 85-264 Vac; 120-300 Vdc Frequency: 47-440 Hz
Inrush current:
<18 A peak @ 115 Vac; <36 A peak @ 230 Vac, cold start @ 25 °C
Input current: 1.5 A max. (RMS) @ 115 Vac Efficiency: 75% typical at full load EMI filter: FCC Class B conducted
CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted
Safety ground leakage current:
<1 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power: 60 W for convection( LPT81, 55 W);
85 W with 30 CFM forced air
Adjustment range: 3.3 V - 5.5 V on outputs one
(and two 1.8 V - 3.5 V for LPT81) Hold-up time: 20 ms @85 W load, 115 Vac nominal line Overload protection: Short circuit protection on all outputs.
Case overload protected @ 145% above peak rating
Overvoltage protection: Tracks outputs 1( & 2 for LPT81): 20% to 35% above
output setting
VDE 60950 UL 60950 CSA 60950 NEMKO 60950 AUSTEL 60950 CB Certificate & report CE Mark LVD
Rev. 05.23.08 LPT80 Series
1 of 3
RoHS
Embedded Power for Business-Critical Continuity
Ordering Information
Model Number
Output Voltage
Minimum Load
Maximum Load with Convection Cooling
Maximum Load with 30CFM forced Air
Peak Load 1Regulation
2
Ripple P/P (PARD)
3
LPT81 +3.3 V (1.8 - 3.5 V)
+5 V (3.3 - 5.5 V) +12 V
0.7 A
0.3 A 0
8.0 A
4.0 A
0.7 A
13 A13 A
1.0 A
15 A 15 A
1.5 A
±2% ±2% ±5%
50 mV 50 mV 120 mV
LPT82 +5 V (3.3 - 5.5 V)
+12 V
-12 V
0.7 A
0.3 A 0
8.0 A
3.0 A
0.7 A
13 A
4.0 A
1.0 A
15 A
4.6 A
1.5 A
±2% ±5% ±5%
50 mV 120 mV 120 mV
LPT83 +5 V (3.3 - 5.5 V)
+15 V
-15 V
0.7 A
0.3 A 0
8.0 A
2.4 A
0.7 A
13 A
3.2 A
0.7 A
15 A
3.7 A 1 A
±2% ±5% ±5%
50 mV 150 mV 150 mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
4. Minimum loads are required
5. Total current of all outputs can not exceed 21 A.
Rev. 05.23.08 LPT80 Series
2 of 3
Operating temperature: 0° to 50 °C ambient;
derate each output at 2.5% per degree from 50° to 70°C
Temperature coefficient: ±0.4% per °C Storage temperature: -40° to 85 °C Electromagnetic
susceptibility: Designed to meet IEC EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 5% to 95%
Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four
major resonances 0.75 G peak 5 Hz to 500 Hz, operational
MTBF demonstrated: >550,000 hours at full load and 25 °C ambient conditions
Environmental Specifications
Logic Control
Power failure
TTL logic signal goes high 100 - 500 msec after V1 output; It goes low at least 4 msec before loss of regulation
Remote inhibit Requires contact closure to inhibit outputs
Remote sense
Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.