Emerson 50M56U-843 INSTALLATION INSTRUCTIONS

50M56U-843 with Black Cover
CAUTION
!
Universal Integrated Single Stage
120V Hot Surface Ignition Control Kit
INSTALLATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.
PARTS INCLUDED
50M56-843 Integrated Furnace Control
• 21D64-2 HotRod Universal Ignitor Kit (120V)
• 3 - Main Harness Assemblies (A, B, M)
• 4 - Ignitor/Inducer Harness Assemblies (C, D, E, H)
• 1 - Rollout Shunt Jumper
• 1 - Carrier Blower Motor Neutral Adapter (L)
• 4 - White 8.5” Long Wiring Extensions
• 4 - Plastic Mounting Standoffs (use without control cover)
• 4 – 1” Sheet Metal Mounting Screws (use with control cover)
• 3 – ½” Sheet Metal Mounting Screws (use with mounting tabs)
• 2 - Wire Ties
• Installation Instructions
INSTALLER MUST READ
SPECIAL REPLACEMENT
INSTRUCTIONS FOUND ON
PAGE 2
DESCRIPTION
The 50M56U-843 is an aftermarket universal replacement control kit for single stage furnace products with PSC blower motors.
TWINNING: 50M56U-843 can be twinned. Both control boards must be from the same manufacturer for proper functionality.
SPECIFICATIONS
ELECTRICAL RATINGS:
Input Voltage: 25 VAC, 50/60 Hz Max Input Current: 0.45 A @ 25 VAC Relay Contact Ratings:
Gas Valve: 1.5 A 0.6 PF @ 30 VAC Ignitor Relay: 1.2 A @ 120 VAC Inducer Relay: 2.8 A @ 120 VAC Circulator Relay: 10 FLA, 25 LRA @ 120 VAC Humidifier Load: 1.0 A @ 24 or 120 VAC Electronic Air Cleaner: 1.0 A @ 120 VAC
Flame Current Requirements:
Minimum current to ensure flame detection: 0.25 μA DC* Maximum current for non-detection: 0.1 μA DC Maximum allowable leakage resistance: 100 M ohms * Measuring with a DC voltmeter (1VDC = 1 μA) Flame Establishing Time: 0.8 seconds maximum Flame Failure Response Time: 2.0 seconds maximum
OPERATING TEMPERATURE RANGE:
-40° to 176°F (-40° to 80°C)
HUMIDITY RANGE:
5 to 95% relative humidity (non-condensing)
AGENCY APPROVALS: CSA USA / Canada GASES APPROVED: Natural, Manufactured, Mixed,
Liquid Petroleum, and LP Gas Air Mixtures.
Risk of Electric Shock. Disconnect electric power to system until installation is complete. Do not use on circuit exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard.
This control is not intended for use in locations where it may come in contact with water.
May cause flame rollout. Shut off main gas to heating system until installation is complete.
emerson.com/white-rodgers
PART NO. 37-7042002
Replaces 37-7042001
2005
SPECIAL REPLACEMENT INSTRUCTIONS
ROLLOUT SHUNT JUMPER REQUIRED ON ALL TRANE/
AMERICAN STANDARD FURNACES, AND ANY YORK P3UR/PCLU MODELS
For proper operation you must install the included shunt jumper on the circled 2-pin R/O “rollout” terminal.
The shunt jumper is packaged separately as an accessory item in the kit. Failure to do so will disable furnace operation.
IGNITOR UPDATE Required on all 80V HSI systems. See Cross References shaded orange on outside of color box.
FLAME SENSOR KIT Required on RHEEM/RUUD Models (1994 and earlier)
If the control being replaced has 2 greens lights (no amber light), and a date code of 3294 or earlier, a Flame Sensor Kit, RHEEM part number 62-24044-71 is required (not available through White-Rodgers).
HARNESS UPDATE Required on existing White-Rodgers
50M56U-843 Control with white cover
If a furnace has already been retrofitted with an original White-Rodgers 50M56U-843 control (white cover) and is being changed out to a new 50M56U-843 (black cover), it is required to also update/replace the Main wire harness adapter that plugs into the 12-pin connector since some control pinouts are different.
White Control Harness
Removed
A New A
B New B
F
K New M
Black Control Harness
Replacement
None, plug factory harness
into 50M56U-843
HARNESS SELECTION TABLE AND DESCRIPTIONS
Most furnaces are serviced by simply installing the new 50M56U-843 control board and included 120V ignitor.
Some furnaces will require the use of an adapter harness for the main system wiring and/or the ignitor/inducer wiring. Use table on page 3 to determine which wire harness(es) in this kit are needed.
If the equipment brand or control P/N does not appear in the table, no harness is required. Plug OEM wiring directly onto 50M56U-843 and proceed with installation and checkout.
2
CARRIER/ICP BRANDS
MAIN HARNESS/OTHER
HK42FZ004 HK42FZ007 HK42FZ008 HK42FZ009 HK42FZ011 HK42FZ016
MAIN HARNESS
194300330001 50A55-250 50A50-285
H A
MAIN HARNESS
R N
1012-83-9336AHSC1 1012-83-9337A 1012933D 1012-933D 41F-5
50T35-730 50T35-730-1 50T35-743 B1809906 B1809906S B1809908
B1809908S B18099-13 B1809913S CNT04664 CNT4664
E S S
MAIN HARNESS
10207701 10207702 102077-02 10207703 102077-03 10207704
S E
L
E
102077-04 10207706 102077-06 102077-09 10207710 102077-10
10207714 102077-14 10207715 10207718 10207719 102077-19
20394001 50A50-207 50A50-288 50A50-298 50A55-288 50A55-288-05
50M56-281 50M56-291 50T55-288 PCB00117 PCBBF117 PCBBF117S
PCBBF134 PCBBF135 PCBBF135S PCBBF136 PCBBF138 PCBBF138S
PCBBF140 PCBBF140S RF000129
C
T
MAIN HARNESS
I
O
ICM280
L
IGNITOR/INDUCER HARNESS
M
FEDDERS & WHITE-RODGERS
None
IGNITOR/INDUCER HARNESS
GOODMAN/AMANA BRANDS (9-pin main connector)
A
IGNITOR/INDUCER HARNESS
GOODMAN/AMANA BRANDS (12-pin main connector)
None
IGNITOR/INDUCER HARNESS
ICM
A
IGNITOR/INDUCER HARNESS
None
E
C
E
C
N
MAIN HARNESS
T A B
L
1012-83-9559B 1012955A 1012-955A 624557 6245570 624564
6245640 624591 624591-A 624591-B 624591-C 624591-D
624628 624628-0 6246310 624631-0 624631A 624631-A
624631B 624631-B 624690 624742 624844 710128A
902378 902696 903106 904840 920915
B
E
MAIN HARNESS
1012-925A 1012-925B 1012-925C 62-22694-01 62-22694-02 62-22694-03
62-22694-11 62-22694-12 62-22694-82 62-22694-83 62-22694-91 62-22737-06
62-22737-07 62-22737-08 62-22737-10 62-22737-87 62-22737-88 62-24044-01
62-24044-81 62-24044-91 62-24045-01 62-24046-01 62-24084-01 62-24084-02
62-24084-71 62-24084-82 62-24084-91 62-24084-92 62-24268-01 62-24268-02
62-24268-03 695-200
NOTE: All other controls install without a harness
B
NORDYNE BRANDS
IGNITOR/INDUCER HARNESS
RHEEM/RUUD BRANDS
IGNITOR/INDUCER HARNESS
D
H
3
A
Furnace
Ground
MAIN HARNESS ADAPTERS A, B, & M
Goodman/Amana Brands, ICM (50T35 variants)
Furnace
9-pin
Furnace
Flame Sense
B
Furnace
9-pin
Furnace 24V
Transformer
Control Board
12-pin
Nordyne Brands, Rheem/Ruud Brands
Control Board Flame Sensor
Control Board
12-pin
4
M
Furnace
2-pin, 3-pin
Furnace 24V
Transformer
Furnace
9-pin
Furnace 24V
Transformer
Carrier/ICPBrands
Control Board
4-pin
Control Board
12-pin