Emerson 3350 User Manual

Quick Reference Guide
P/N 20001008, Rev. B August 2005
Model 3700 Transmitter (MVD) or Model 3350 Peripheral
Installation Instructions for Field-Mount
In the U.S.A., phone 1-800-522-MASS (1-800-522-6277)
In Canada and Latin America, phone (303) 527-5200
In Asia, phone (65) 6770-8155
In the U.K., phone 0800 - 966 180 (toll-free)
Outside the U.K., phone +31 (0) 318 495 670
BEFORE YOU BEGIN
This quick reference guide explains basic installation guidelines for installing the Micro Motion
®
Model 3350/3700 MVD applications
platform.
For information on I.S. applications, refer to Micro Motion approval documentation.
For complete instructions about configuration, maintenance, and service, refer to the instruction manual shipped with the transmitter.
WARNING
Improper installation in a hazardous area can cause an explosion.
For information about hazardous applications, refer to Micro Motion approval documentation, shipped with the transmitter or available from the Micro Motion web site.
WARNING
Hazardous voltage can cause severe injury or death.
Install transmitter and complete all wiring before supplying power.
CAUTION
Improper installation could cause measurement error or meter failure.
Follow all instructions to ensure transmitter will operate correctly.
©2005, Micro Motion, Inc. All rights reserved. Micro Motion is a registered trademark of Micro Motion, Inc. The Micro Motion and Emerson logos are trademarks of Emerson Electric Co. All other trademarks are property of their respective owners.
1
European installations
This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this quick reference guide. Refer to the EC declaration of conformity for directives that apply to this product.
The EC declaration of conformity, with all applicable European directives, and the complete ATEX Installation Drawings and Instructions are available on the web at www.micromotion.com/atex or through your local Micro Motion support center.
Installation kit
The Model 3350/3700 installation kit includes the parts shown in Figure 1.
Figure 1. Field-mount installation kit
Mounting bracket
4 x Lock washer
Transmitter can be oriented on bracket. See Step 3.
4 x Flat washer
4 x M8x16 Bolt assemblies
2
STEP 1. Choosing a location
Choose a location for the transmitter based on the requirements described below.
WARNING
Improper installation in a hazardous area could cause an explosion.
Install the transmitter in an area that is compatible with the rating on the approvals tag. See Figure 3.
Environmental requirements
Install the Model 3350/3700 according to specified limits:
Ambient temperature: –4 to +140 °F (–20 to +60 °C)
Dimensions
See Figures 2, 3, and 4 for Model 3350/3700 dimensions.
Visibility of tags
To ensure personal and system safety, all tags attached to the housing must remain visible. Clean them as often as necessary. Replace tags that are damaged, missing, or worn. See Figure 3 for location of approvals tag.
3
Figure 2. Dimensions – face view
inches
(mm)
4 x 5/16-inch
(9 mm)
diameter
2 13/16
(71)
Mounting bracket can be rotated as needed
11
(279)
12
(305)
4
(102)
9 3/16
(234)
Display cover can be
rotated as needed
Figure 3. Dimensions – top view
inches
(mm)
6 1/8 (158)
8 11/16
(221)
3 5/8
(92)
6
(152)
5 1/16-inch (129 mm)
clearance for removal of
circuit boards
Approvals tag
15 1/2
(394)
11 5/16
(288)
4
Figure 4. Dimensions – conduit openings view
inches
(mm)
Case ground
5 x 3/4–14 NPT
or
5 x M20 x 1.5 – 6H
2 x 15/16
(24)
1 7/8
(48)
Mounting surface
2 x 2 13/17
(71)
7 1/2 (191)
5 3/4 (147)
10 3/8
(265)
Cable lengths
Maximum cable length from the sensor to the Model 3700 transmitter depends on the installation type and cable type:
4-wire remote transmitter: see Figure 5, then refer to Table 1 for maximum length of the 4-wire cable.
Remote core processor with remote transmitter: see Figure 6, then refer to Table 1 for maximum length of the 4-wire cable and the 9-wire cable.
If you are installing the Model 3350 applications peripheral in combination with a transmitter, the maximum cable length from the transmitter’s frequency output to the Model 3350’s frequency input is 500 feet (150 meters).
5
Figure 5. 4-wire remote transmitter
Sensor
Core processor (standard or enhanced)
4-wire cable
Model 3700
Figure 6. Remote core processor with remote transmitter
Model 3700
Sensor
4-wire cable
Junction box
9-wire cable
Core processor (standard only)
Table 1. Maximum cable lengths
Cable type Wire gauge Maximum length
Micro Motion 9-wire Not applicable 60 feet (20 meters)
Micro Motion 4-wire Not applicable 1000 feet (300 meters)
User-supplied 4-wire
• Power wires (VDC) 22 AWG
(0,35 mm
20 AWG (0,5 mm
18 AWG (0,8 mm
• Signal wires (RS-485) 22 AWG (0,35 mm
Cable from transmitter’s FO to Model 3350’s FI
(1)
Not applicable 500 feet (150 meters)
(1) Applies only to the Model 3300 applications peripheral when receiving frequency input
from a remote Micro Motion transmitter such as an IFT9701 or RFT9739.
2
) 300 feet (90 meters)
2
) 500 feet (150 meters)
2
) 1000 feet (300 meters)
2
) or larger 1000 feet (300 meters)
6
STEP 2. Preparing conduit openings for ATEX Zone 1
s
If the Model 3350/3700 carries an ATEX Zone 1 approval:
1. Remove thread protectors from conduit openings (see Figure 7).
2. Install factory-supplied cable glands or user-supplied EExe cable entry devices in conduit openings that are in use.
3. Install EExe plugs in conduit openings that are not in use.
STEP 3. Orienting the Model 3350/3700 (optional)
The Model 3350/3700 can be oriented on the mounting bracket as needed, and the display cover can be rotated on the applications platform. Figure 7 provides orientation examples.
To orient the Model 3350/3700:
1. Use the four supplied mounting bolt assemblies.
2. Using a 13 mm hex wrench, install the bolt assemblies to 12 ft-lb (16 Nm) of torque.
To rotate the display cover, if needed, see the transmitter installation manual.
Figure 7. Orientation examples
Conduit openings
Conduit openings for
intrinsically safe
sensor wiring
Conduit openings for
non-intrinsically safe
input/output wiring
left
Conduit openings right
Display cover
Conduit opening down
7
Loading...
+ 16 hidden pages