Elite Robo Slide Instruction Manual

Page 1
eliteaccess.com
®
ACCESS SYSTEMS INC
AC CES S SYS TEM S INC
Instruction Manual
ROBO SLIDE
Installation instructions and manual book for
architects, general contractors and dealers
C
opyright © 2000 by Elite Access Systems, Inc. – www.eliteaccess.com
Click on the desired topic in the “Bookmarks” column or “Table of Contents” to select page.
Page 2
TABLE OF CONTENTS
Important Notice Safely Operating Gate Configuration and Specifications Warnings and Precautions Step 1: Getting Started Step 2: Mounting Operator Step 3: Chain Installation Step 4: Gate Movement Direction Step 5: DC Power Supply Connection Step 6: “Optional” Solar Panel Step 7: Terminal Connections Step 8: Adjusting Gate Travel Distance Step 9: Timer Step 10: 2-Way Adjustable Reversing Sensor “Optional” Input Board Master and Slave Operators with Timer Master and Slave Operators without Timer Control Board Functions LED Descriptions Troubleshooting
How to Reset Breaker Switch How to Check Fuses Gate will not close! Gate will not open! If you hear a “BEEP” sound
Robo Slide Parts List Robo Slide Parts
2 3 4 5 5 6 6 7 8
9 10 11 11 12 13 14 15 16
17-18
19 19 20 20 21 21 22
PLEASE DO NOT TOUCH ME!...UNLESS YOU ARE AN AUTHORIZED SERVICE TECHNICIAN!
© COPYRIGHT 1992 BY ELITE ACCESS SYSTEMS, INC.
Release 6
All rights reserved. No part of this manual may be reproduced in any means; graphic, electronic, mechanical, or photocopied without the express written permission of the publisher of this material
1
5/01
Page 3
IMPORTANT NOTICE
Closing
Closing
Incorrect Installation using a Catch Post!
Correct Installation with Catch Rollers
Wall
Catch Rollers
Gate
1/2" Clearance Between Gate and Rollers
Minimum Clearance of 5" Between Back of Gate and Wall or Other Objects in Gate's Path
1/4" Clearance from Top of Gate
5"
A physical stop MUST be installed on the gate prior to installation of the gate operator. This will assure that the gate does not derail while in motion.
CAUTION
Gate in Fully Opened Position Gate Clearances
IMPORTANT!
Because gate coasting distance varies with temperature, Elite DOES NOT
recommend the installation of a catch post. This could cause the gate to collide with the post.
Guide Rollers (Elite Part # A UHM)
Page 4
SAFELY OPERATING GATE
Owners Must Never Let Pedestrians Cross the Path of a Moving Gate!
Owners Must Never Mount Any Gate Operating Devices Accessible In Between the Gate and the Wall!
Owners Must Never Mount Any Gate Operating Devices Accessible Through the Gate!
CAUTION
CAUTION
CAUTION
Page 5
CONFIGURATION AND SPECIFICATIONS
Elite's Recommended Gate Setup Configuration
Warning Signs on Both Sides of Gate
Over-Travel Stops
on Both Ends of
Gate Rail
Guide Rollers
Guide Rollers
2"x 2" Mesh Wire Across Entire Gate
Warning Sign Clearly Visible on Gate Operator
Be sure to read and follow all Elite's instructions before installing and operating any Elite product. Always disconnect the gate operator's power source before repairs are attempted. Elite Access Systems, Inc. is not responsible for improper installation or failure to comply with local building codes.
CAUTION
Robo Slide Specifications:
Gate Speed – 11 inch per second Maximum Gate Length – 20 feet Maximum Gate Weight – 800 pounds Maximum Cycles – 70 cycles per day with Elite's Plug-In Transformer.
Solar power cycles per day varies, Contact Elite for more Information
Battery back-up cycles (50 cycles total) AC Power Supply – 18 VAC 2.0 Amp Plug-In Transformer (Elite Part # A POW-1) AC Power Supply Wire – 14 gauge or greater landscape lighting cable rated for direct burial and
300 watts at maximum length of 1000 ft
DC Power Supply – Built-in, back-up for AC or Solar power failure only Solar Power – Optional (Elite Part # SOLAR 3)
Reinforced Concrete to Bolt Operator on
18 VAC Plug-In Transformer, for Each Gate Operator
U.L. Listed Underground Conduit for Wires
3" Maximum Picket Width
Steel V-Groove, High Speed Ball Bearing Wheels
Page 6
READ ENTIRE OWNERS MANUAL BEFORE INSTALLATION
CAUTION
Model:
Warnings and Precautions
DO NOT Use for Apartment or Condominium Applications.
1. Do not tighten chain too tight
2. Use proper type of wheels - only 4" steel wheels with high speed ball bearings
3. Do not use a 12V transformer - use only 18 VAC 2.0 Amp
4. Do not install as a rear-mount installation
5. Use only 14 gauge or greater landscape lighting cable rated for direct burial and 300 watts
Robo Slide
For Single Home Applications.
STEP 1: Getting Started
This gate operator is designed for single home application, or for limited commercial applications. An example of a commercial application would be a factory facility with limited cycles per day, using a plug in transformer or solar panel.
PLEASE DO NOT REPAIR ME!...UNLESS YOU ARE AN AUTHORIZED SERVICE TECHNICIAN!
Page 7
Correct Chain Installation
Incorrect Chain Installation
Too High
Too Low
STEP BY STEP INSTALLATION
STEP 2: Mounting Operator
STEP 3: Chain Installation
Pour concrete bed for Robo Slide. Minimum size of bed is 20" x 15" x 20"d. Suggested installation for bolts is 1/2" x 3 1/2" (for red-head fastener).
Minimum space between gate and output sprocket must be 4". After you position the gate operator, bolt-down the operator to the concrete bed. Make certain that the concrete bed is solid.
6"
Concrete (Reinforced Recommended)
Above Ground
Power Supply Line
20"
20"
15"
10"
8"
O
VER
LO
AD
PO
W
ER
C
H A
R G E
O K
B
A T T
E R Y
L
O W
O P
E N
R
E L
A Y
C L
O S
E
R E L
A Y
T I M
E R
U P
O N
W1
O F
F
O P
E N
T O
R I
G H
T
6
0
0
P W
C E
N T
R A
L C
O N
T R
O L
S
Y S
T E
M
O
N
D C
O P
E R
A T O
R v
5 M
M
A
D E
I N
U S
A
A
L A R
M S E
N S
O
R
R E V
E R
S
E S E
N S O
R
H E
A V
Y G A
T
E
FIR
E
D
EPT
STRIKE O
PEN
SAFE
TY
L
OOP
EX
IT
LOOP
R
ADIO
REC
C H A
R G I
N
G P O
W E
R
B O A
R
D P O W
E
R
C
H E
C K
F
U S
E
J2
Red Head Fastener
1/2" x 3 1/2"
Gate
Incorrect Chain Spacing
4" Minimum
Gate
Correct Chain Spacing
or
Gate Front
Gate Rear
Page 8
STEP BY STEP INSTALLATION
STEP 4: Gate Movement Direction
Plug in the limit/motor harness wires to the left socket (#1) if your gate, from the inside of the property, opens to the left and closes to the right. Plug into the right socket (#2) if the gate opens to the right and closes to the left from the inside of the property.
OVERLOAD POWER
CHARGE OK
BATTERY LOW
OPEN RELAY CLOSE RELAY
TIMER
UP
ON
W1
OFF
O
P
E
N
T
O
R
IG
H
T
Socket #1
Socket #2
60
0
PW
CENTRAL CONTROL
S
Y
S
T
E
M
O
N
D
C
O
P
E
R
A
T
O
R
v
5
M
MADE IN USA
A
L
A
R
M
S
E
N
S
O
R
R
E
V
E
R
S
E
S
E
N
S
O
R
H
E
A
V
Y
G
A
T
E
F
IR
E
D
E
P
T
S
T
R
IK
E
O
P
E
N
S
A
F
E
TY
LO
O
P
E
X
IT
L
O
O
P
R
A
D
IO
R
E
C
CHARGING
POWER
BOARD POWER
CHECK
FUSE
J2
OUT
IN
OUT
IN
Open to Right
Open to Left
Socket #1
Socket #2
Page 9
OVERLOAD
POWER
BATTERY LOW
OPEN RELAY CLOSE RELAY
TIMER
UP
ON
OFF
60
0
PW
CENTRAL CONTROL
S
Y
S
T
E
M
O
N
D
C
O
P
E
R
A
T
O
R
v
5
M
MADE IN USA
A
L
A
R
M
S
E
N
S
O
R
R
E
V
E
R
S
E
S
E
N
S
O
R
H
E
A
V
Y
G
A
T
E
F
IR
E
D
E
P
T
S
T
R
IK
E
O
P
E
N
S
A
F
E
T
Y
L
O
O
P
E
X
IT
L
O
O
P
R
A
D
IO
R
E
C
CHARGING
POWER
BOARD POWER
CHECK
FUSE
J2
C
H
AR
G
E O
K
CHARGE OK
OVERLOAD POWER
BATTERY LOW
OPEN RELAY CLOSE RELAY
TIMER
UP
ON
W1
OFF
O
P
E
N
T
O
R
IG
H
T
60
0
PW
CENTRAL CONTROL
S
Y
S
T
E
M
O
N
D
C
O
P
E
R
A
T
O
R
v
5
M
M
ADE IN USA
A
L
A
R
M
S
E
N
S
O
R
R
E
V
E
R
S
E
S
E
N
S
O
R
H
E
A
V
Y
G
A
T
E
F
IR
E
D
E
P
T
S
T
R
IK
E
O
P
E
N
S
A
F
E
T
Y
L
O
O
P
E
X
IT
L
O
O
P
R
A
D
IO
R
E
C
CHARGING
POWER
BOARD POWER
CHECK
FUSE
J2
CHARGE OK
STEP BY STEP INSTALLATION
Use Elite's optional 18 VAC plug-in transformer (Elite Part # A POW-1). Hook up the transformer to 115 VAC. Use two, low voltage, 14 gauge / 300watt direct burial, landscape lighting cables. Hook these wires to the two yellow wires from the control board to the plug-in transformer.
STEP 5: DC Power Supply Connection
18 VAC Plug-in Transformer
14 Gauge Wires
Maximum Wire Length
should not exceed 1000 ft.
Polarity Does Not Matter
2
1
3
5
6
8
1
0
7
9
4
Yellow Wires #2, #4
Do Not use solar panel and plug-in
transformer at the same time.
To 115 VAC
CAUTION
Beep!
After the plug-in transformer has been connected to the power source, connect the battery cable plug to the limit/motor harness plug. You will immediately hear a beep for a few
seconds. After the beep, check the “Charge OK” LED......
Limit/Motor Harness
......it must be ON.
Page 10
If you use Elite's optional solar panel (Elite Part # Solar 3). Connect the two wires from the solar panel to the two yellow wires on the control board. Sunlight will energize the batteries through the solar panel. This solar panel will charge up to 2800 Mamp/Hr in optimum conditions & 500 Mamp/Hr in light overcast conditions. For detailed specifications consult the Solar 3 Installation sheet.
OVERLOAD POWER
BATTERY LOW
OPEN RELAY CLOSE RELAY
TIMER
UP
ON
W1
OFF
O
P
E
N
T
O
R
IG
H
T
60
0
PW
CENTRAL CONTROL
S
Y
S
T
E
M
O
N
D
C
O
P
E
R
A
T
O
R
v
5
M
MADE IN USA
A
L
A
R
M
S
E
N
S
O
R
R
E
V
E
R
S
E
S
E
N
S
O
R
H
E
A
V
Y
G
A
T
E
F
IR
E
D
E
P
T
S
T
R
IK
E
O
P
E
N
S
A
F
E
T
Y
L
O
O
P
E
X
IT
L
O
O
P
R
A
D
IO
R
E
C
CHARGING
POWER
BOARD POWER
CHECK
FUSE
J2
CHARGE OK
STEP BY STEP INSTALLATION
STEP 6: Optional Solar Panel Connection
Energizing Robo Slide with solar power only needs the radio receiver to operate the gate. The only recommended external devices other than radio receivers are dry-contact command devices which do not consume any current like key switches. Using other
devices that consume high current such as telephone access, magnetic locks or loop detectors will cause excess drainage of the battery and eventually completely drain the battery .
Elite recommends using 1 or 2 larger batteries (12 VDC, 30
Amp) (Elite Part # A 12330 or
A 12330 PACK) in Robo Slide
when using the optional solar panel.
Polarity Does
Not Matter
2
1
3
5
6
8
1
0
7
9
4
Yellow Wires #2, #4
Do Not use solar panel and plug-in
transformer at the same time.
CAUTION
CAUTION
Solar Panel
(Elite Part # SOLAR 3) No Stand
30 Amp.
12 VDC
For More Details,
contact your Local Dealer
Page 11
STEP BY STEP INSTALLATION
12345678910
12 VDC Radio Receiver
Transmitters
External “Exit” Loop Detector
External “Safety” Loop Detector
Phone Entry
Push Button
Card Reader
Fire or Any Key Switch
Terminal 8 = Grey Wire Terminal 8 = Black Wire Terminal 9 = Grey Wire Terminal 10= Red Wire
4 7
8 0
H
E
L
P
9
1
2
3
5
6
Photo Electric Eye
The radio receiver must be 12 VDC only (Elite Part # A 1099-12V). If you want to use safety or exit loops, you must use 12 VDC loop detectors only (Elite Part # A 23). The hook-ups for the radio receiver are as follows: Strike open wires go to 8 and 9 on terminal. Power supply goes to terminal 10 (positive +) and terminal 8 (negative -). Connections for other devices are shown below.
STEP 7: Terminal Connections
(Elite Part #A 3060)
(Elite Part #A 3089)
Page 12
TIMER
UP
ON
OFF
60
0
PW
Adjustment is done by limit switches which are located on the Robo Slide chassis. By pressing the plate down and spinning the adjustment nuts, set your limit switches for open and close cycles.
STEP BY STEP INSTALLATION
STEP 8: Adjusting Gate Travel Distance
STEP 9: Timer
If you want to use the automatic close for the gate system the timer switch should be put in the ON position. If you want to use the push open or push close command, the timer should be switched to the OFF position.
Limit Switches
Each notch of the nut indicates an estimated 1 inch of gate travel
OVERLOAD
POWER
BATTERY LOW
OPEN RELAY CLOSE RELAY
TIMER
UP
ON
W1
OFF
O
P
E
N
T
O
R
IG
H
T
60
0
PW
CENTRAL CONTROL
S
Y
S
T
E
M
O
N
D
C
O
P
E
R
A
T
O
R
v
5
M
MADE IN USA
A
L
A
R
M
S
E
N
S
O
R
R
E
V
E
R
S
E
S
E
N
S
O
R
H
E
A
V
Y
G
A
T
E
F
IR
E
D
E
P
T
S
T
R
IK
E
O
P
E
N
S
A
F
E
T
Y
L
O
O
P
E
X
IT
L
O
O
P
R
A
D
IO
R
E
C
CHARGING
POWER
BOARD
POWER
CHECK
FUSE
J2
CHARGE OK
Set Timer 1 to 60 seconds
TIMER
UP
ON
OFF
60
0
PW
Page 13
There is a blue pot with a white screw adjustment on the upper portion of the control board marked “REVERSE SENSOR”. Do Not Touch Alarm Sensor blue pot.
The level of sensitivity has to do with the weight of the gate and the condition of installation.
Too sensitive = if the gate stops or reverses by itself. Not sensitive enough = if the gate hits an object and does not stop or reverse.
STEP BY STEP INSTALLATION
STEP 10: Two-Way Adjustable Reversing Sensor
OVERLOAD
POWER
BATTERY LOW
OPEN RELAY CLOSE RELAY
TIMER
UP
ON
W1
OFF
O
P
E
N
T
O
R
IG
H
T
60
0
PW
CENTRAL CONTROL
S
Y
S
T
E
M
O
N
D
C
O
P
E
R
A
T
O
R
v
5
M
MADE IN USA
A
L
A
R
M
S
E
N
S
O
R
R
E
V
E
R
S
E
S
E
N
S
O
R
H
E
A
V
Y
G
A
T
E
F
IR
E
D
E
P
T
S
T
R
IK
E
O
P
E
N
S
A
F
E
T
Y
L
O
O
P
E
X
IT
L
O
O
P
R
A
D
IO
R
E
C
CHARGING
POWER
BOARD POWER
CHECK
FUSE
J2
CHARGE OK
SYSTEM ON
ALARM
SENSOR
REVERSE
SENSOR
HEAVY
GATE
NOW YOUR INSTALLATION IS COMPLETE
There is an LED “HEAVY GATE” which will light up when the gate is heavier than normal for the operator. The operator will still function properly.
Maximum Sensitivity
Minimum Sensitivity
Page 14
OVERLOAD POWER
BATTERY LOW
OPEN RELAY CLOSE RELAY
CENTRAL CONTROL
SYSTEM ON
DC OPERATOR v 5M
MADE IN USA
A
LA
R
M
SEN
SO
R
R
EVER
SE
SEN
SO
R
H
EA
VY
G
A
TE
FIRE DEPT
CHARGING
POWER
BOARD POWER
CHECK
FUSE
J2
CHARGE OK
“OPTIONAL” INPUT BOARD
The optional board allows extra control of the gate, is available only from Elite Access Systems. Installation is simple; just clip the optional board to the J2 slot on the top of the control board. Below lists the function of each pin.
Open Switch Stop Switch (Cut W1 Jumper at Bottom of Board) Timer Close Output from Master to Slave Timer Input from Slave to Master (Close Command) Vandalism Alarm Output (Not Burglar Alarm) - 12 VDC Emergency Open (Direct Command from Battery to Motor) Emergency Close (Direct Command from Battery to Motor) Magnetic Lock - Dry Contact Relay (Com NC) Center Loop Option (For Swing Gate Operators Only)
16
2
4
6
8
10
12
14
15
13
11
9
7
5
3
1
1 & 2 3 & 4 5 & 6 7 & 8
9 &10 11 & 4 12 & 7
13 & 14 15 & 16
W1
16-Pin Plug
Use a Normally Closed Contact
Page 15
MASTER AND SLAVE WITH TIMER
To use the master/slave option with Robo Slide, you must purchase the Optional Input Board (Elite Part # Q203) and connect it to the J2 slot.
Refer to Optional Input Board
1
3
5
7
9
11
13
15
10
8
6
4
2
12
14
16
16
14
12
10
8
6
4
2
15
13
11
9
7
5
3
4 Low Voltage Wires Connect Gate Operators Together
Master J2 Plug
1. Make master/slave J2 plug connections as shown above
2. Turn timers on BOTH control boards to the “ON” position
3. Use MASTER timer ONLY for the auto close time adjustment (0 to 60 sec)
4. Turn the SLAVE timer adjustment all the way Counterclockwise
Slave J2 Plug
Master Pin 1 to Slave Pin 1
Master Pin 5 to Slave Pin 7
Master Pin 6 to Slave Pin 8
Master Pin 2 to Slave Pin 2
Caution: 18 VAC plug-in transformer, per gate operator required
1
TIMERTIMER
UP
ONON
OFF
6060
0
PW
Master Timer “ON
Master Slave
TIMERTIMER
UP
ONON
OFF
60
0
PW
Slave Timer “ON
Maximum
Counterclockwise
Setting
Set Timer 0 to 60 seconds
Page 16
MASTER AND SLAVE WITHOUT TIMER
To use the master/slave option with Robo Slide, you must purchase the Optional Input Board (Elite Part # Q203) and connect it to the J2 slot.
Refer to Optional Input Board
1
3
5
7
9
11
13
15
10
8
4
6
2
12
14
16
16
14
12
10
6
8
4
2
15
13
11
9
5
7
3
2 Low Voltage Wires Connect Gate Operators Together
Master J2 Plug
1. Make master/slave J2 plug connections as shown above
2. Turn timers on BOTH control boards to the “OFF” position
Slave J2 Plug
Master Pin 1 to Slave Pin 1
Master Pin 2 to Slave Pin 2
Caution: 18 VAC plug-in transformer, per gate operator required
1
Master Timer “OFF
Master Slave
Slave Timer “OFF
TIMERTIMER
UP
ON
OFFOFF
60
0
PW
TIMERTIMER
UP
ON
OFFOFF
60
0
PW
Page 17
O
V
E
R
L
O
A
D
P
O
W
E
R
B
A
T
T
E
R
Y
L
O
W
O
P
E
N
R
E
L
A
Y
C
L
O
S
E
R
E
L
A
Y
T
IM
E
R
U
P
O
N
W1
O
F
F
OPEN TO RIGHT
60
0
P
W
CENTRAL CONTROL
SYSTEM ON
DC OPERATOR v 5M
MADE IN USA
A
LA
R
M
SEN
SO
R
R
EVERSE
SEN
SO
R
H
EA
VY
G
A
TE
FIRE DEPT
STRIKE OPEN
SAFETY LOOP
EXIT LOOP
RADIO REC
CHARGING
POWER
BOARD POWER
CHECK
FUSE
J2
C
H
A
R
G
E
O
K
CONTROL BOARD FUNCTIONS
1
Power on LED
2
Charge on LED
3
Low battery indicator LED
4
Heavy gate indicator LED
5
Open Relay LED
6
Close Relay LED
7
System on, Reversing sensor and Alarm sensor
8
Alarm sensor LED
9
Reversing sensor LED (Rebounder)
10
Central control LED
11
Fire department or key switch LED
12
Strike open LED
13
Safety loop or photocell LED
14
Exit loop LED
15
Radio receiver LED
16
Timer power LED
17
Timer-Up indicator
18
J2 alternate optional output
19
Movement direction sockets
20
Replace fuse indicator
21
Spike suppressor
22
Jumper for stop button
23
Optional Input board
24
Plug in power - 18 VAC or solar panel
and terminal block connector
25
Breaker reset
26
Overload LED
15
14
13
12
11
10
4
9
23
8
7
18
24
21
17
16
2219
20
1
26
2 3
5 6
25
Page 18
LED DESCRIPTION
Power at all times when
there is one or more power sources
ie: Battery, 18 VAC or solar
Charger OK on when there
is any charging power
ie: 18 VAC - solar
Battery Low
normally off - it will indicate low battery
System On
will work only when the gate is in motion
Alarm Sensor
when LED goes on you will hear a beep sound for about 20 seconds
Heavy Gate
will work only when the gate is in motion
Open Relay
Open relay is not energized
1. No power source at all
If dimmed down
1. Bad board power fuse
1. No Transformer or Solar
If dimmed down
1. Bad Charging power fuse
1. Motor stop
2. No motor current detected
Battery OK Battery voltage is over minimum required limit
Gate weight and condition are OK
System is OK
Open relay is energized
Flashing LED - Battery is less than required limit needs to be recharged
Power source OK and board power fuse OK
Transformer or solar OK and charging power fuse OK
1. Excess usage
2. Bad charging system
3. Under rate solar panel
4. Bad battery
5. Bad battery connection
1. Hearing beep sound
means overload
2. Gate is too heavy
3. Broken wheel
4. Gate off track
5. Unwanted object has
physically stopped gate
1. Gate is too heavy
2. Bad wheels
3. Bad rollers
4. Chain is too tight
5. Steep slope on open or
close cycle
6. Low battery
Close Relay
Close relay is not energizedClose relay is energized
Detecting motor current
Note:
Circled red numbers indicates location on control board. Refer to Control Board Functions
1
2
3
5
6
7
8
4
LED Description LED On LED Off
Page 19
LED DESCRIPTION - CONTINUED
LED Description LED On LED Off
Note:
Circled red numbers indicates location on control board.
9
Reversing Sensor
No obstruction is detectedSensor is detecting obstruction
11
Fire Dept
Receiving signal at terminal block 1 & 2
Not receiving signal at terminal block 1 & 2
10
Central Control
Not receiving any command
Acknowledgement of receiving open command from one of the terminals
• Fire Department 1
& 2
• Strike Open 3
& 4
• Safety Loop 5
& 6
• Exit Loop 7
& 8
• Radio Receiver 8
& 9
12
Strike Open
Receiving signal at terminal block 3
& 4
Not receiving signal at terminal block 3 & 4
13
Safety Loop
Receiving signal at terminal block 5
& 6
Not receiving signal at terminal block 5 & 6
14
Exit Loop
Receiving signal at terminal block 7
& 8
Not receiving signal at terminal block 7 & 8
15
Radio Rec
Receiving signal at terminal block 8
& 9
Not receiving signal at terminal block 8 & 9
17
Timer UP
Output signal to close relay
Not receiving signal to close relay
16
Timer PW
Timer power is on Timer is not on
Refer to Control Board Functions
Page 20
OVERLOAD
POWER
BATTERY LOW
OPEN RELAY CLOSE RELAY
DC OPE
MAD
H
EA
VY
G
A
TE
C
H
A
R
G
IN
G
P
O
W
E
R
B
O
A
R
D
P
O
W
E
R
CHECK
FUSE
J2
CHARGE OK
OPEN TO RIGHT
If the gate is not moving in any direction be sure to check all of the LED displays on the control board. If the board power or charging power LEDs are ON, change the corresponding fuse on the top left corner of the board.
TROUBLESHOOTING
If all electronic sensors fail or are not adjusted properly due to heavy gates, off-track gate, or obstructed gate path, the breaker will kick-out. Reset the breaker by pressing the reset button located on the bottom left corner of the control board.
How to Reset the Breaker
How to Check the Fuses
CAUTION
CAUTION
Always disconnect the battery before resetting the breaker or injury could occur as the gate starts.
The breaker reset is located at the bottom left corner of the control board as shown
Replace fuse with
1.5A - 250V fuse
(Elite Part # Q162)
Robo Fuse
Page 21
0
PW
CENTRAL CONTROL
DC
O
PE
R
A
TO
R v 5M
MADE IN USA
FIRE D
EPT
STRIK
E
O
PEN
SAFETY LO
O
P
EXIT LO
O
P
RADIO
REC
TROUBLESHOOTING
The Gate Will Not Close!
Symptom:
The radio receiver LED on the control board
remains “ON” when using the remote control.
Possible Solutions:
Stuck remote control button. The radio receiver has malfunctioned in the “ON position.
0
PW
CENTRAL CONTROL
D
C
O
PE
R
A
TO
R
v 5M
MADE IN USA
FIR
E
D
EPT
STRIK
E
O
PEN
SA
FETY
LO
O
P
EXIT LO
O
P
RADIO REC
The Gate Will Not Open!
Symptom:
The radio receiver LED on the control board
remains “OFF” when using the remote control.
Possible Solutions:
Dead battery in the remote control. Remote control code switches are different from radio receiver code switches. The radio receiver has malfunctioned in the “OFF” position.
For further information, contact your local dealer.
Page 22
TROUBLESHOOTING and PARTS LIST
Multiple Parts “Q” Number
A BT 12 - 12 VDC, 7 amp. Battery with Harness A H-110 - Gate Chain #41 (10 ft) (20 ft included) A H-111 - Gate Chain #40 (10 ft) Optional A H-113 - Master Link A H-125 - Master Link Q003 - Chain Bolt Q004 - Chain Bracket Q006 - PC Board Nuts (1 Set) Q029 - Limit Switch Q032 - Limit Switch Adjustment Nut Q101 - Limit Switch Bearing Holder Q123 - Motor - DC - 12V
Robo Slide Conversion Kit
Q204
Q211 - Limit/Motor Harness Q218 - Terminal Harness Q206 - Control Board Battery Harness
Q124 - Chassis Q129 - Idler Sprocket with Bolt/Nut Q131 - Limit Switch Drive Sprocket Q132 - Limit Switch Sprocket Q133 - Drive Sprocket Q135 - Limit Switch Bolt (Shaft) Q137 - Limit Switch Box Q156 - 1/2 Inch Collar Q162 - Fuse Q180 - 1 inch Diameter Coupling Q203 - Option Board with Harness Q206 - Control Board Q211 - Limit/Motor Harness Q212 - Gear Reducer 40 - 30:1 Q218 - Terminal Harness Q241 - Cover, Polyethylene Plastic
If you hear a “BEEP” sound, the gate is too heavy. If not check below.
Robo Slide Parts List
The gate is hitting a wall or a car.
21
Debris is on the gate's track such as mud, rocks dirt, etc.
ALARM
SENSOR
ALARM
SENSOR
ALARM
SENSOR
ALARM
SENSOR
The gate has one or more broken wheels. A car has hit the gate and
the gate is off the track.
43
After fixing the problem, the Robo Slide will automatically reset itself.
21
Page 23
Note: *Sold Individually, 2 Shown.
For part names, refer to parts list
ROBO SLIDE PARTS
Q241
O V
E R
L
O
A
D
P O
W E
R
C HAR
GE O
K
B ATTE
R Y LOW
O
PEN RELAY
CLOSE R
ELAY
T
IM
E
R
U
P
O
N
W
1
O
F
F
O
P
E
N
T O
R I
G H
T
6
0
0
P
W
C
E
N
T
R
A
L
C
O
N
T
R
O
L
S
Y
ST
EM
O
N
D
C
O
P
E
R
A
T
O
R
v
5
M
MADE IN USA
ALA
RM
SE
NSO
R
RE
VERS
E
SE
NSOR
HEA
VY G ATE
F I
R
E
D E
P
T
S
T R
I
K
E
O
P
E N
S
A F
E
T
Y L O
O
P
E X
I
T
L O
O
P
R A
D
I
O
R E
C
C
H A
R G
I N
G P O
W E
R
B
O A
R
D
P
O W
E
R
C
H
EC
K
F
USE
J
2
*Q004
*Q003
Q006
Q162
Q203
Q206
Q211
Q206
Q218
Battery
Harness
Q204
Conversion Kit
Q134
Q133
Q132
Q131
Q218
Q211
Q212
Q180
Q123
*Q129
Q124
A BT 12
A H-110
#41
A H-113 A H-125
A H-111
#40
*Q029
Q137
Q135
Q156
*Q032
*Q101
O
V E
R
L O
A D
P
O W
E
R
CHARGE OK
BATTERY LOW
OPEN RELAY CLOSE RELA
Y
T
IM
E
R
U
P
O
N
W
1
O
F
F
O
P E
N
T O
R
I G H
T
6
0
0
P
W
C
E
N
T
R
A
L
C
O
N
T
R
O
L
S
Y
ST
E
M
O
N
D
C
O
P
E
R
A
T
O
R
v
5
M
MADE IN USA
ALA
R M
SEN
SO
R
R EV
ER
S
E
SE
NSO
R
HEA
V Y
G
ATE
F I
R E
D E
P
T
S
T R
I K
E
O
P E
N
S
A F
E T
Y
L
O O
P
E X
I T
L O
O
P
R
A D
I O
R
E C
C H
A
R G
I N
G P O
W
E
R
B O
A
R
D P O
W
E
R
CH
E CK
FU
SE
J
2
Loading...