Elenco 5MHz Function Generator User Manual

5MHz FUNCTION GENERATOR
MODEL GF-8056
User’s Manual
Copyright © 2004 by ElencoTMElectronics, Inc. All rights reserved. 753117
No part of this book shall be reproduced by any means; electronic, photocopying, or otherwise without written permission from the publisher.
Elenco
Electronics, Inc.
NOTICE BEFORE OPERATION
1. Unpack the instrument:
After receiving the instrument, immediately unpack and inspect it for any damage which might have occured during transportation or shortage of accessories. If any signs of damage and/or shortage of accessories are found, notify the dealer immediately.
2. Environments:
Normal operating temperature of the instrument is 10°C to 40°C (50°F to 104°F). Operation of the instrument outside of this temperature range may cause damage to the circuits.
Do not use the instrument in a place where strong magnetic or electric fields exist. Such fields may disturb the measurement.
3. Check the Line Voltage:
The instrument can operate on any one of the line voltages shown in the table below by inserting the line voltage selector plug in the corresponding position on the rear panel. Before connecting the power plug to an AC line outlet, be sure to check that voltage selector plug is set in the correct position corresponding to the line voltage.
CAUTION: The instrument may not properly operate or may be damaged if it is connected to an AC line with the wrong voltage. When line voltages are changed, replacement of the fuses is also required.
Hints for operating the instrument:
Observe the following suggestions for successful instrument operation.
1. Never place heavy objects on the instrument.
2. Never place a hot soldering iron on or near the instrument.
3. Never insert wires, pins or other metal objects into the ventilation fan.
4. Never move or pull the instrument with power cord or probe cord. Never move the instrument especially when the power cord or signal probe is connected to a circuit.
5. If the instrument is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
WARNING: The following precautions must be observed to help prevent electric shock.
1. When the instrument is used for testing, there is always a certain amount of danger from electrical shock. The person using the instrument should be a qualified electronics technician or otherwise trained and qualified to work in such circumstance.
2. Do not operate the instrument with the cover removed unless you are a qualified service technician.
3. The ground wire of the 3-wire AC power plug places the chassis and housing of the instrument at earth ground. Use only a 3-wire outlet, and do not attempt to defeat the ground wire connection or float the instrument. Doing so may pose a great safety hazard.
4. Do not obstruct the ventilation holes in the rear panel, as this will increase the internal temperature.
5. Never apply an external voltage to the output BNC connector of the instrument.
6. Excessive voltage applied to the input BNC connector may damage the instrument.
!
!
-1-
Selector Line Voltage Fuse
115V 100~125V 50/60Hz 600mA 230V 220~240V 50/60Hz 300mA
-2-
GENERAL
DESCRIPTION
The GF-8056 is a deluxe function generator combined with a 5-digit, high-resolution 60MHz counter. The GF-8056 is a rugged, easy-to­operate, excellent heat dissipating and high stability instrument. The GF-8056 is a 4-in-1 instrument. It can be used as the following described four kinds of electronic instruments respectively:
1. As a Function Generator:
Eight waveforms selected by a rotary switch instead of push-button to prevent accidental touching or bad connections. Maximum output 20Vp-p (no load) and minimum output 0.1Vp-p (no load).
2. As a Pulse Generator:
The GF-8056 provides positive pulse and reverse negative pulse output with the Pull Reverse Switch, maximum output 20Vp-p (no load). Frequency display by the LED, pulse width from
0.4sec to 100ns. Can meet most audio, video and other basic electronic application requirements.
3. As a Sweep Generator:
The GF-8056 provides linear sweep or log sweep. Use the selection switch to select the sweep mode. Maximum sweep width 1:100 and sweep speed 5sec to 10ms. Also, the GF-8056 provides VCF input and synchronous output function. Easy-to-operate.
4. As a Counter:
The GF-8056 is a 5-digit, micro-controlled counter. The GF-8056 features auto-range, auto­gate time and high-resolution - 0.001Hz, input impedance - 1M, bandwidth - 0.2Hz~60MHz, voltage resistance - 150Vp-p. Other features the GF-8056 provides: adjustable trigger +
2.5V with LED indication. Display unit auto-indicate, HF / LF selector, 100kHz filter.
5. As a DC Voltage:
The GF-8056 provides a DC output function. The output voltage can be adjusted from +10V to –10. It can be used as a low-power DC source.
SPECIFICATIONS
1. General Specifications: A. Generator
Frequency: 0.05Hz~5MHz, display on 5-digit
LED display, maximum resolution
0.001Hz in 8 ranges.
Waveform output: Sine, square, triangle,
positive, ramp, negative ramp, positive pulse and negative pulse, DC, 8 waveforms.
Stability:
0.1%~15 minutes after switch “ON”
0.2%~24 hrs. after switch “ON”
DC offset: +
10V (no load), +5V (50Ω load),
continuously adjustable, controlled by an offset switch.
B. Counter
Display: 5 digits 0.36” red LED Max. resolution: 0.001Hz Display unit: Hz/kHz automatically
controlled by CPU
C. Common Specification
Operating temperature: 0°C~40°C,
10%~80% R.H.
Storage temperature: –20°C~70°C,
0%~90% R.H.
Power source: AC 115V (+
10%) 50/60Hz, FUSE: 600mA AC 230V (+
10%) 50/60Hz,
FUSE: 300mA
Power consumption: 25W Ventilation: DC 12V / 100mA fan Dimensions: 275 x 90 x 300mm Weight: 2.5 kgs. net. Accessory: Power cord, operation manual
2. Triangle Wave:
Frequency: 0.05Hz~5MHz Symmetry: 50% (rise wave) to 50% (fall
wave), < 1%, 1Hz~100kHz
Linearity: < 1%, (1Hz~100kHz)
SPECIFICATIONS (continued)
3. Sine Wave:
Frequency: 0.05Hz~5MHz Distortion: < 1%, 1Hz~100kHz Harmonic ratio: < 30dB, 100kHz~5MHz Frequency response: < 0.1dB, up to 100kHz
< 1.5dB, 100kHz to 5MHz
4. Square Wave:
Frequency: 0.05Hz~5MHz Symmetry: 50% (positive half) to 50% (negative
half). < 1%, 1Hz~100kHz
Rise time: < 90ns (20Vp-p , no load)
5. Ramp Wave:
Frequency: 0.05Hz~4.5MHz, 8 range
selected by rotary switch
Symmetry:
90% (rise wave) to 10% (fall wave), continuously adjustable
Linearity:
< 1%, (0.1Hz~100kHz)
6. Positive Pulse:
Frequency: 0.05Hz~4.5MHz Width:
0.4sec~100ns, continuously adjustable
Symmetry:
1:1 to 10:1 continuously adjustable 1Hz~100kHz
Reverse:
Pull the Rev. switch, the output will become a negative pulse
7. DC:
Output voltage: +10V to –10V continuously
adjustable by OFFSET switch
8. Main Output:
Output impedance: 50, < 2% Max. output:
20Vp-p (no load), +1Vp-p
10Vp-p (50load) +
0.5V
Min. output:
0.1Vp-p (no load), or 0.05Vp-p (50load)
Attenuator:
One –26dB (1/20) attenuator, < 2% accuracy
9. Synchonous Output:
Output impedance: 50, < 2% accuracy Output level: TTL level, > 3Vp-p fixed amplitude Fan out: >20 Rise time: <60nS
10. V.C.F. Input:
Input impedance: 0~10V Input frequency: DC~1kHz variable 1:1 to 1:100
11. Sweep Synchronous Output:
Output impedance: 1k, < 2% Output waveform: Linear or log sweep ramp wave Output amplitude: 10Vp-p (no load) or
5Vp-p (1kload)
Output frequency:
0.2Hz~100Hz continuously adjustable
12. Sweep Generator:
Sweep form: Linear or log switchable Sweep speed:
5sec~10ms, continuously adjustable
Sweep width:
1:1~1:100
13. Counter:
Display: 5 digits, 0.36” red LED display Max. Resolution: 0.001Hz Display unit: Hz / kHz autorange Time base: 20MHz Temperature coefficient: < 20ppm / °C Accuracy: <0.02% +
1 digit
Power supply: +5V, 160mA
Internal Counter:
Range: Autorange with 4 resolution,
0.001Hz / 0.01Hz / 0.001kHz /
0.01kHz, auto-controlled by CPU
Display: 0.500Hz~5000.0kHz auto-select by
CPU
Gate time: Variable, 0.25sec~5sec,
auto-setting
Min. display digits: 4 digits
External Counter:
Max. input voltage: < 150Vrms Input impedance: 1M, < 2% Input frequency: 0.2Hz ~60MHz Coupling: HF - 100kHz and greater
LF - 100kHz and lower Min. display digits: 4 digits Gate time: 0.25sec~10sec, auto-setting
depends on the input frequency
Sensitivity: > 30mVrms (1MHz)
-3-
Loading...