Electrolux DFKTWC75GS User Manual

Page 1
Use & Care Guide
Installation Instructions
Vent Hood
316495007 - 09/2007
Page 2
2
Page 3
Finding Information
Please read and save this guide
Thank you for choosing Electrolux, the new premium brand in home appliances. This Use & Care Guide is part of our commitment to customer satisfaction and product quality throughout the service life of your new appliance.
We view your purchase as the beginning of a relationship. To ensure our ability to continue serving you, please use this page to record important product information.
Keep a record for quick reference
Purchase date
Electrolux model number
3
NOTE
Registering your product with Electrolux enhances our ability to serve you. You can register online at www.electroluxusa.com or by dropping your Product Registration Card in the mail.
Questions?
For toll-free telephone support in the U.S. and Canada:
1-877-4ELECTROLUX (1-877-435-3287) For online support and Internet product information visit http://www.electroluxusa.com
Table of contents
Finding information ................................................ 3
SAFETY .............................................................. 4
Verify package contents............................................6
Installation ........................................................... 7
• Install the ductwork .............................................................. 7
• Wiring.................................................................................8
• Install mounting bracket ....................................................... 9
• Install flue mounting bracket ................................................ 9
• Prepare the hood ................................................................ 10
• Install the hood ................................................................... 12
• Install filters.......................................................................14
Maintenance ....................................................... 15
• Grease filters ....................................................................... 15
• Non-Ducted recirculation filters.......................................... 15
• Hood cleaning .................................................................... 15
Operation ........................................................... 16
• Controls.............................................................................16
• Halogen bulbs....................................................................17
• Fuse replacement...............................................................17
Warranty information..............................................18
©2007 Electrolux Home Products, Inc.
All rights reserved. Printed in Italy
Page 4
4
Safety
Important Safety Instructions
Read all instructions before using this appliance.
Save these instructions for future reference.
Do not attempt to install or operate your appliance until you have read the safety precautions in this manual. Safety items throughout this manual are labeled with a WARNING or CAUTION based on the risk type.
This symbol alerts you to situations that may cause serious body harm, death or property damage.
This symbol alerts you to situations that may cause bodily injury or property damage.
INTENDED FOR DOMESTIC COOKING ONLY
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all ap­plicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Fol­low the heating equipment manufacturer’s guide-
lines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigera­tion and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any separate solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A.Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
B.Always turn hood ON when cooking at high heat or
when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).
C.Clean ventilating fans frequently. Grease should not
be allowed to accumulate on fan or filter.
D.Use proper pan size. Always use cookware
appropriate for the size of the surface element.
Page 5
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
Safety
6. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes over­heated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced.
7. For best capture of cooking impurities, the bottom of the hood should be a minimum of 24" and a maximum of 30" above the cooking surface.
8. Two installers are recommended because of the large size and weight of this hood.
5
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result.
4. Use an extinguisher ONLY if:
A.You know you have a Class ABC extinguisher
and you already know how to operate it.
B. The fire is small and contained in the area where
it started. C.The fire department is being called. D.You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published
by NFPA.
1. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
9. This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel.
10. Please read specification label on product for further information and requirements.
AUTOMATICALLY OPERATED DEVICE. TO REDUCE THE RISK OF INJURY, DISCONNECT FROM POWER SUPPLY BEFORE SERVICING. THE UNIT IS EQUIPPED WITH AN INTEGRAL DISCONNECTING SWITCH LOCATED INSIDE THE BLOWER HOUSING.
INTEGRAL DISCONNECTING SWITCH
2. Take care when using cleaning agents or detergents.
3. Avoid using food products that produce flames under the Range Hood.
4. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
5. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
Page 6
6
Verify package contents
Unpack hood and check contents. You should receive: 1 - Hood 1 - Decorative Flue Assembly 1 - Parts Bag containing:
1 - Mounting Bracket 1 - Discharge Collar 1 - Flue Mounting Bracket 6 - Mounting Screws (4,8 x 38mm Pan Head) 7 - Mounting Screws (3,9 x 9,5mm Pan Head) 2 - Mounting Screws (3.9 x 6mm Flat Head)
6 - Drywall Anchors 2 - Grease Filters 1 - Installation Instructions 1 - Warranty Card
2 MOUNTING SCREWS
(3.9 x 6mm Flat Head)
FLUE MOUNTING BRACKET
DECORATIVE FLUE
GREASE FILTERS
DISCHARGE COLLAR
6 MOUNTING SCREWS
(4,8 x 38mm Pan Head)
MOUNTING BRACKET
7 MOUNTING SCREWS (3,9 x
9,5mm Pan Head)
6 DRYWALL ANCHORS
Page 7
Install the ductwork
To reduce the risk of fire, use only metal ductwork.
1. Decide where the ductwork will run between the hood and the outside.
2. A straight, short duct run will allow the hood to perform most efficiently.
3. Long duct runs, elbows, and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs.
DECORATIVE
FLUE
HOOD
24” TO 30” ABOVE
COOKING SURFACE
Installation
ROOF CAP
ROUND DUCT
WALL
ROUND ELBOW
ADAPTER
7
CAP
6”
4. Install a roof or wall cap. Connect round metal ductwork to cap and work back towards hood location. Use duct tape to seal the joints between ductwork sections.
5. Never make the size or area of the ductwork smaller than the size that originates at the hood.
6. Bigger ductwork is better.
7. Keep duct lenght less than 50 linear feet.
8. Minimize use of elbows and transitions (4 or less).
9. Always separate 90 degree elbows with at least 2 feet of straight ductwork.
10. Place transitions at least 1 foot from the hood outlet.
Page 8
8
Installation
Wiring
This range hood must be properly grounded. The unit should be installed by a qualified
electrician in accordance with all applicable national and local electrical codes.
GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
Improper grounding can result in a risk of electric shock.
Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded.
33-7/16" (85cm) max
Do not use an extension cord. If the power supply cord is too short, have a qualified
electrician install an outlet near the appliance. Set the electrical power supply within the space covered
by the decorative flues.
Position the power socket at a maximum distance of 33-7/16” (85 cm) from where the lead exits from the hood (see illustration alongside).
Make sure this does not interfere with the bracket fastening area or with the decorative flue (where the flue touches the wall).
Fit the plug into the power socket.
Page 9
Installation
9
Install mounting bracket
1. Construct wood wall framing that is flush with inte­rior surface of wall studs.
Make sure: a) the framing is centered over installation loca-
tion.
b) the height of the framing will allow the mounting
bracket to be secured to the framing within the dimensions shown.
2. After wall surface is finished, secure mounting bracket to framing using dimensions shown.
FRAMING BEHIND DRYWALL
37” to 43” above cooktop
Install flue mounting bracket
DUCTED AND NON-DUCTED
1. Assemble the flue mounting bracket, adjusting outside width as shown.
2. Carefully center the mounting bracket directly over the range hood location.
3. Secure the bracket assembly to the ceiling using (2)
4.8x38mm mounting screws and drywall anchors. Make sure the bracket is pushed into the corner, tight against the wall and centered over the hood.
FLUE MOUNTING BRACKET
3.9 x 6 mm
FLAT HEAD BRACKET SCREWS
37"= bottom of hood 24" above cooktop 43"= bottom of hood 30" above cooktop
10-5/8”
(270.4 mm)
Page 10
10
Installation
Prepare the hood
NOTE
On stainless steel hoods, carefully remove the plastic protective film from all exterior surfaces of the hood and decorative flues, prior to final installation.
1. Remove the polystyrene block and the tape (Fig.1).
2. The back plate shown in Fig. 2 must be removed: remove the (4) screws of the back plate, operating from the inside of the hood (Fig. 3).
3. Remove the tape on the electrical system plate; place the electrical system plate on the hood (protect surface from electrical system plate using cardboard protection). Fig. 4.
4. Remove the (2) screws of the back plate (Fig. 5) and discard the back plate.
POLYSTYRENE BLOCK
TAPE
BACK PLATE
FIG. 1
ELECTRICAL SYSTEM PLATE
PROTECTION
FIG. 3
FIG. 4
FIG. 2
FIG. 5
Page 11
Installation
11
DUCTED CONFIGURATION
1. Install the discharge collar into the duct connector of the range hood. Fig. 6.
DISCHARGE
COLLAR
DUCT
CONNECTOR
FIG. 6
NON- DUCTED CONFIGURATION
NOTE
The following materials must be purchased separately for non-ducted recirculation installations:
Non - Ducted Recirculation Kit, Model DFKTWC75GS. 5” diameter duct.
1. Discard discharge collar/damper supplied with the hood. Install the 5” to 6” adapter supplied with the Non-Ducted Recirculation Kit (Fig. 7).
2. Secure the plenum to the flue mounting bracket with (2) 3.9x6mm flat head screws (the screws are supplied with the Non-Ducted Recirculation Kit “DFKTWC75GS”). Fig. 8.
5”-6”
ADAPTER
3.9x6mm
FLAT HEAD
SCREWS
PLENUM
FIG. 7
FLUE MOUNTING
BRACKET
FIG. 8
Page 12
12
Installation
Install the hood
NOTE
At least two people will be required to mount the hood.
1. Raise the hood into its mounting position.
2. Align the rectangular opening on the back of the hood with the wall-mounting bracket. Gently lower the hood until it securely engages the bracket. Fig. 9.
3. Level the hood with (2) 3.9x9.5mm mounting screws and secure with (2) 4.8x38mm mounting screws. Use drywall anchors provided if wall studs or framing are not available. Fig. 9.
4. Mount the electrical system plate attaching it with (3) 3.9x9.5mm mounting screws. Fig. 10.
5. On ducted hoods, attach 6" round metal duct between the hood’s blower collar and duct that leads to the outside location (Fig. 11).
6. On non-ducted hoods, attach 5" round metal expandable duct between the 5"- 6" adapter on the hood and the connector on the plenum (Fig. 12).
7. Tape all duct joints to make them secure and air tight.
8. Plug the power cord into the electric wall receptacle. Tuck excess cord behind the flue.
MOUNTING SCREWS
MOUNTING SCREWS
(4.8x38mm)
6” ROUND
METAL DUCT
(3.9x9.5mm)
WALL MOUNTING
BRACKET
MOUNTING SCREWS
(4.8x38mm)
RECTANGULAR
OPENING
BLOWER COLLAR
FIG. 9
MOUNTING SCREWS
(3.9x9.5mm)
5” ROUND
METAL DUCT
PLATE OF THE
ELECTRICAL SYSTEM
FIG.10
PLENUM
5”-6”
ADAPTER
FIG.11
FIG.12
Page 13
Installation
9. Carefully place the decorative flue on the hood. Fig. 13.
- On ducted installation in rooms with 8-foot ceilings, the air vents are concealed. Install the flue with the air vents down.
- On non-ducted installations in rooms with 8-foot ceilings, the air vents are exposed. Install the flue with the air vents up.
- On ducted and non-ducted installations in rooms with 9-foot ceilings, the vents are exposed. Install the flue with air vents up.
ROOMS WITH 10-FOOT CEILINGS
Rooms with 10-foot ceilings require flue extension model EXWC75GS, available from your local dealer.
10. Discard the upper flue supplied with the product. Replace it with the flue extension EXWC75GS.
11. Raise the upper flue until its holes align with holes in the flue mounting bracket (located on ceiling). Fig.14.
12. Secure the flue with (2) 3.9x9.5mm mounting screws. Fig. 14.
13
UPPER FLUE
LOWER FLUE
UPPER FLUE VENTS
EXPOSED
UPPER FLUE
LOWER FLUE
UPPER FLUE VENTS
CONCEALED
FIG.13
3.9x9.5mm
MOUNTING SCREWS
FIG.14
Page 14
14
Installation
Install filters
(DUCTED AND NON-DUCTED HOODS)
1. To remove the GREASE filters, pull the metal latch tab outside and unlock the filter.
2. To install the GREASE filters, align rear filter tabs with slots in the hood. Depress the metal latch tab, push filter into position and release. Make sure filter is securely engaged after installation.
NOTE
Prior to use, remove protective film from the filter frame.
(NON-DUCTED HOODS ONLY)
1. To remove the CHARCOAL filter, push in on the front filter latch. Pull the filter down to disengage the rear filter tabs.
2. To install the CHARCOAL filter, align the rear filter tabs with slots in the hood. Push the filter up into place until the front latch snaps securely into the slot. Make sure the filter is securely engaged after assembly.
3. Install GREASE filters after charcoal filter is in­stalled.
GREASE FILTERS
LATCH
TABS
NON-DUCTED
RECIRCULATION
FILTER
Page 15
Maintenance
Proper maintenance of the Range Hood will assure proper performance of the unit.
15
Grease filters
The grease filters should be cleaned when the filter reset switch will be illuminated.
Use a warm detergent solution. Grease filters are dishwasher safe.
See “INSTALL FILTERS” section for removal and installation instructions.
Once the grease filters are cleaned and installed, press in and hold the “filter reset switch” for approximately 3 seconds.
Non-Ducted Recirculation filters
The non-ducted recirculation filter should be changed when the filter reset switch will be illuminated and blink.
See “INSTALL FILTERS” section for removal and installation instructions.
Once the new charcoal filter is installed, press in and hold the “filter reset switch” for approximately 3 seconds.
Hood cleaning
Stainless steel is one of the easiest materials to keep clean. Occasional care will help preserve its fine appearance.
Cleaning tips: O Hot water with soap or detergent is all that is usu-
ally needed.
O Follow all cleaning by rinsing with clear water. Wipe
dry with a clean, soft cloth to avoid water marks.
O For discolorations or deposits that persist, use a
non-scratching household cleanser or stainless steel polishing powder with a little water and a soft cloth.
O For stubborn cases, use a plastic scouring pad or
soft bristle brush together with cleanser and water. Rub lightly in direction of polishing lines or "grain" of the stainless finish. Avoid using too much pressure which may mar the surface.
O DO NOT allow deposits to remain for long periods
of time.
O DO NOT use ordinary steel wool or steel brushes.
Small bits of steel may adhere to the surface causing rust.
O DO NOT allow salt solutions, disinfectants,
bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals which may be harmful. Rinse with water after exposure and wipe dry with a clean cloth.
Painted surfaces should be cleaned with warm water and mild detergent only.
Page 16
16
Operation
Controls
filter
light
switch
Dead-front mode
Stand-by mode
In dead-front mode, press any key for enter in stand­by mode. If the hood is in stand-by mode, after 10 seconds on return automatically in dead-front mode.
Light switch
Press any key for enter in stand-by mode. Push the light switch once to turn the lights ON to a dim level. Push a second time to turn the lights ON to a brighter level. Push a third time to turn the lights OFF (stand-by mode).
Fan speed switches
Press any key for enter in stand-by mode. The fan speed switches turns the fan on. 1 : fan ON at low speed 2 : fan ON at medium-low speed 3 : fan ON at medium-high speed 4 : fan ON at high speed
Fan on/off switch
Push this fan switch to turn OFF the fan. The hood turns in the stand-by mode.
reset
switch
fan
on/off
switches
display
fan speed
switches
Push this switch once to turn the timer Off.
Filter reset switch
When the filter switch is illuminated, it is necessary to clean the GREASE FILTERS. Once the grease filters are cleaned and installed, press in and hold the “filter reset switch” for approximately 3 seconds.
When the filter switch is illuminated and blink, it is necessary to replace the CHARCOAL FILTER. Once the new charcoal filter is installed, press in and hold the “filter reset switch” for approximately 3 seconds.
Heat Sentry
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed. When the Heat Sentry is active, the word “HS” appears in the display and the tone alarm is active. To disarm the tone alarm, press the 4 fan speed switch. When the temperature level drops to normal, the blower will return to its original setting.
delay shut
off
IMPORTANT
The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. When this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the blower, do it from the integral disconnecting switch located inside the blower housing.
Heat Sentry active
Delay shut off switch
Pressing this switch when is active any speed, sets a timer which keeps the fan operating at this speed for 10 minutes (the number “10” appears in the display). After 10 minutes, the hood turns in the stand-by mode.
Page 17
Operation
17
Halogen bulbs
This range hood requires two halogen bulbs (max 20W, 12V, Type T3 bulb, G4 Base).
Halogen Bulb Key : 5304454951
ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE.
To change bulbs:
1. Open the cover by prying from the proper slots. - D O NOT ROTATE. CAUTION: BULB MAY BE HOT!
3. Replace with a max 20W, 12V, Type T3 bulb, G4 Base bulb. Do not touch replacement bulb with bare hands! If the bulb is touched with the bare hand, it should be cleaned with a lint-free cloth moistened with methylated spirit.
Fuse replacement
SWITCH OFF THE ELECTRICITY SUPPLY.
Remove the grease filters. Open the fuse box. Replace with the same type of fuse (5x20mm, 4A, 125V).
Fuse Key : 5304455332
FUSE
FUSE BOX
Page 18
18
Warranty Information
In the U.S.A., your appliance is warranted by Electrolux Home Products North America, a division of White Consolidated Industries, Inc. We authorize no person to change or add to any of our obligations under this warranty. Our obligations for service and parts under this warranty must be performed by us or authorized Electrolux Home Products North America servicer. In Canada, our appliance is warranted by Electrolux Canada Corp.
FULL ONE-YEAR WARRANTY
LIMITED WARRANTY (Applicable to the State of Alaska)
*NORMAL RESPONSIBILITIES OF THE CONSUMER
EXCLUSIONS
WARRANTY
PERIOD
One year from original purchase date
Time periods listed above
This warranty applies only to products in ordinary household use and the consumer is responsible for the items listed below.
1. Proper use of the appliance in accordance with instructions provided with the product.
2. Proper installation by an authorized servicer in accordance with instructions provided with the appliance and in accordance with all local plumbing, electrical and/or gas codes.
3. Proper connection to grounded power supply of sufficient voltage, replacement of blown fuses, repair of loose connections or defects in house wiring.
4. Expenses for making the appliance accessible for servicing, such as removal of trim, cupboards, shelves, etc., which are not a part of the appliance when it was shipped from the factory.
5. Damages to finish after installation.
6. Replacement of light bulbs and/or fluorescent tubes (on models with these features).
This warranty does not cover the following:
1. CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN OR ANY IMPLIED WARRANTY.
NOTE: Some states do not allow the exclusion or limitation of incidental or consequential damages, so
this limitation or exclusion may not apply to you.
2. Service calls which do not involve malfunction or defects in workmanship or material, or for appliances not in ordinary household use. The consumer shall pay for such service calls.
3. Damages caused by services performed by servicers other than Electrolux Home Products North America or its authorized servicers; use of parts other than genuine Electrolux Home Products parts; obtained from persons other that such servicers; or external causes such as abuse, misuse, inadequate power supply or acts of God.
4. Products with original serial numbers that have been removed or altered and cannot be readily determined.
THROUGH OUR AUTHORIZED SERVICERS,
WE WILL:
Pay all costs for repairing or replacing any parts of this appliance which prove to be defective in materials or workmanship.
All of the provisions of the full and limited warranties above and the exclusions listed below apply.
THE CONSUMER WILL BE
RESPONSIBLE FOR:
Costs of service calls that are listed under NORMAL RESPONSIBILITIES OF
THE CONSUMER.*
Costs of the technician’s travel to the home and any costs for pick up and delivery of the appliance required because of service.
IF YOU NEED SERVICE
This warranty only applies in the 50 states of the U.S.A., Puerto Rico and Canada. Product features or specifications as described or illustrated are subject to change without notice. All warranties are made by Electrolux Home Products North America, a division of White Consolidation Industries, Inc. In Canada, your appliance is warranted by Electrolux Canada Corp.
USA 1-800-944-9044
Electrolux Home Products North America P.O. Box 212378 Augusta, GA 30917
Keep your bill of sale, delivery slip, or some other appropriate payment record. The date on the bill establishes the warranty period should service be required. If service is performed, it is in your best interest to obtain and keep all receipts. This written warranty gives you specific legal rights. You may also have other rights that vary from state to state. Service under this warranty must be obtained by contacting Electrolux Home Products.
Canada
1-866-294-9911
Electrolux Home Products
North America
802, boul. L’Ange-Gardien
L’Assomption, Quebec J5W 1T6
Page 19
19
Page 20
04307838/3S
Loading...