Identification:
Technical Bulletin no:
Date: Issuer: Factory:

Subject

C08
PDD2005-10
New boiler for AOS102G
Model Problem Reason Action in Factory
Action in Field
New boiler with different dimensions
AOS 102 gas range Low lifetime of burner gasket Working temperature of the rubber close to its limits New boiler and protection of the gasket; optimized the distribution of
temperature in the combustion chamber. Modification in production from SN 515.
In case of burnt gasket, the old boiler should be changed with the new one. The new boiler (0C2567) is interchangeable with the old one changing also the pipe connecting burner and fan (0C2568), the ignition rod (0C1866, changed the length of the cable from 970mm to 1040mm, same spare part code, cleaned warehouse) and using another gasket (0C2569) and the suitable insulation (0C2589)
ELECTROLUX PROFESSIONAL SPA MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIALE TREVISO, 15 33170 PORDENONE - ITALY
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIALE TREVISO, 15 33170 PORDENONE - ITALY
++39 0434 380528 www.electrolux.com 00072220932
++39 0434 380555 filippo.fingolo@electrolux.it
BOILER AOS102G
code: 0C2567
To use new boiler you have also to install:
New gas pipe connecting boiler burner and boiler fan
PIPE
code: 0C2568
Also is necessary to use one more gasket to protect boiler from overheating
GASKET
code: 0C2569