Einhell TE-AC 270/24/10 User manual [ml]

D Originalbetriebsanleitung
Kompressor
GB Original operating instructions
Compressor
F Mode d’emploi d’origine
DK/ Original betjeningsvejledning N Kompressor
S Original-bruksanvisning
Kompressor
HR/ Originalne upute za uporabu BIH Kompresor
RS Originalna uputstva za upotrebu
Kompresor
CZ Originální návod k obsluze
Kompresor
TE-AC 270/24/10
SK Originálny návod na obsluhu
Kompresor
1
Art.-Nr.: 40.104.50 I.-Nr.: 11013
Anl_TE_AC_270_24_10_SPK1.indb 1Anl_TE_AC_270_24_10_SPK1.indb 1 19.09.13 18:2219.09.13 18:22
1
14
27
15
1 8
2
3
5 9
7
18
2
Anl_TE_AC_270_24_10_SPK1.indb 2Anl_TE_AC_270_24_10_SPK1.indb 2 19.09.13 18:2219.09.13 18:22
8
6 13
10
12
11 4
3
16
17
- 2 -
4a 4b
14
3 18
24 22 2225 26
1
20
19
4c 5
9
21 2222 23
4
24,18
26 25 22
3
6 7
23
22
4
19 9
21,22
- 3 -
Anl_TE_AC_270_24_10_SPK1.indb 3Anl_TE_AC_270_24_10_SPK1.indb 3 19.09.13 18:2219.09.13 18:22
19
8 9
20
10 11
1
12
17
Max Min15
- 4 -
Anl_TE_AC_270_24_10_SPK1.indb 4Anl_TE_AC_270_24_10_SPK1.indb 4 19.09.13 18:2319.09.13 18:23
D
Warnung - Zur Verringerung des Verletzungsrisikos Bedienungsanleitung lesen
Tragen Sie einen Gehörschutz. Die Einwirkung von Lärm kann Gehörverlust bewirken.
Warnung vor elektrischer Spannung!
Warnung vor heißen Teilen!
Warnung! Die Einheit ist ferngesteuert und darf ohne Warnung anlaufen
Achtung! Vor Erstinbetriebnahme Ölstand überprüfen und Ölverschlussstopfen austauschen!
Verbot! Gerät nicht mit o enen Türen oder o enem Gehäuse betreiben.
- 5 -
Anl_TE_AC_270_24_10_SPK1.indb 5Anl_TE_AC_270_24_10_SPK1.indb 5 19.09.13 18:2319.09.13 18:23
D
Achtung!
Beim Benutzen von Geräten müssen einige Si­cherheitsvorkehrungen eingehalten werden, um Verletzungen und Schäden zu verhindern. Lesen Sie diese Bedienungsanleitung / Sicherheitshin­weise deshalb sorgfältig durch. Bewahren Sie die­se gut auf, damit Ihnen die Informationen jederzeit zur Verfügung stehen. Falls Sie das Gerät an an­dere Personen übergeben sollten, händigen Sie diese Bedienungsanleitung / Sicherheitshinweise bitte mit aus. Wir übernehmen keine Haftung für Unfälle oder Schäden, die durch Nichtbeachten dieser Anleitung und den Sicherheitshinweisen entstehen.
1. Sicherheitshinweise
Die entsprechenden Sicherheitshinweise fi nden Sie im beiliegenden Heftchen!
Warnung
Lesen Sie alle Sicherheitshinweise und An­weisungen. Versäumnisse bei der Einhaltung der
Sicherheitshinweise und Anweisungen können elektrischen Schlag, Brand und/oder schwere Verletzungen verursachen. Bewahren Sie alle
Sicherheitshinweise und Anweisungen für die Zukunft auf.
Dieses Gerät ist nicht dafür bestimmt, durch Per­sonen (einschließlich Kinder) mit eingeschränk­ten physischen, sensorischen oder geistigen Fähigkeiten oder mangels Erfahrung und/oder mangels Wissen benutzt zu werden, es sei denn, sie werden durch eine für ihre Sicherheit zustän­dige Person beaufsichtigt oder erhielten von ihr Anweisungen, wie das Gerät zu benutzen ist. Kinder sollten beaufsichtigt werden, um sicherzu­stellen, dass sie nicht mit dem Gerät spielen.
2. Gerätebeschreibung und Lieferumfang
2.1 Gerätebeschreibung (Bild 1-4)
1. Ansaug-Luftfi lter
2. Druckbehälter
3. Rad
4. Standfuß
5. Schnellkupplung (geregelte Druckluft)
6. Manometer (eingestellter Druck kann abgele-
sen werden)
7. Druckregler
8. Ein-/ Aus-Schalter
9. Transportgri
10. Sicherheitsventil
11. Ablass-Schraube für Kondenswasser
12. Manometer (Kesseldruck kann abgelesen werden)
13. Schnellkupplung (ungeregelte Druckluft)
14. Öl-Verschlussstopfen
15. Öl-Ablassschraube
16. Überlastschalter
17. Schauglas
18. Radkappe
19. Schraube (Innensechskant) für Griff montage
20. Schlüssel (Sechskant)
21. Schraube
22. Unterlegscheibe
23. Mutter
24. Achsschraube
25. Federring
26. Mutter
27. Öl-Einfüllöff nung
2.2 Lieferumfang
Bitte überprüfen Sie die Vollständigkeit des Arti­kels anhand des beschriebenen Lieferumfangs. Bei Fehlteilen wenden Sie sich bitte spätestens innerhalb von 5 Arbeitstagen nach Kauf des Arti­kels unter Vorlage eines gültigen Kaufbeleges an unser Service Center oder an den nächstgelege­nen zuständigen Baumarkt. Bitte beachten Sie hierzu die Gewährleistungstabelle in den Garan­tiebestimmungen am Ende der Anleitung.
Öffnen Sie die Verpackung und nehmen Sie
das Gerät vorsichtig aus der Verpackung. Entfernen Sie das Verpackungsmaterial so-
wie Verpackungs-/ und Transportsicherungen (falls vorhanden). Überprüfen Sie, ob der Lieferumfang vollstän-
dig ist. Kontrollieren Sie das Gerät und die Zubehör-
teile auf Transportschäden. Bewahren Sie die Verpackung nach Möglich-
keit bis zum Ablauf der Garantiezeit auf.
Achtung! Gerät und Verpackungsmaterial sind kein Kinderspielzeug! Kinder dürfen nicht mit Kunststoff beuteln, Folien und Kleinteilen spielen! Es besteht Verschluckungs- und Er­stickungsgefahr!
Ansaug-Luftfilter
Rad (2x)
Standfuß
Transportgriff
Öl-Verschlusstopfen
- 6 -
Anl_TE_AC_270_24_10_SPK1.indb 6Anl_TE_AC_270_24_10_SPK1.indb 6 19.09.13 18:2319.09.13 18:23
Radkappe (2x)
Schraube (Innensechskant) für Griffmontage
(4x) Schlüssel (Sechskant)
Schraube
Unterlegscheibe (6x)
Mutter, für Standfuß-Montage
Achsschraube (2x)
Federring (2x)
Mutter, für Achsmontage (2x)
Originalbetriebsanleitung
Sicherheitshinweise
3. Bestimmungsgemäße Verwendung
Der Kompressor dient zum Erzeugen von Druck­luft für druckluftbetriebene Werkzeuge.
Die Maschine darf nur nach ihrer Bestimmung verwendet werden. Jede weitere darüber hinaus­gehende Verwendung ist nicht bestimmungsge­mäß. Für daraus hervorgerufene Schäden oder Verletzungen aller Art haftet der Benutzer/Bedie­ner und nicht der Hersteller.
D
4. Technische Daten
Netzanschluss: ..............................230 V ~ 50 Hz
Motorleistung: .......................................... 1800 W
Kompressor-Drehzahl min
Betriebsdruck bar: ....................................max. 10
Druckbehältervolumen (in Liter): ...................... 24
Theo. Ansaugleistung l/min.: .......................... 270
Abgabeleistung (Druckluft)
bei 7 bar: .........................................100 Liter/min
Abgabeleistung (Druckluft)
bei 4 bar: ..........................................127 Liter/min
Schalleistungspegel L Unsicherheit K Schalldruckpegel L Unsicherheit K
Schutzart: ......................................................IP20
Gerätegewicht in kg: .............................. ca. 27 kg
Ölmenge: .........................................ca. 0,23 Liter
Geräusch
Die Geräuschemissionswerte wurden entspre­chend EN ISO 2151 ermittelt.
...................................... 1,98 dB
WA
....................................... 1,98 dB
pA
-1
: ......................... 2850
in dB: ......................... 94
WA
in dB: .............................. 72
pA
Bitte beachten Sie, dass unsere Geräte bestim­mungsgemäß nicht für den gewerblichen, hand­werklichen oder industriellen Einsatz konstruiert wurden. Wir übernehmen keine Gewährleistung, wenn das Gerät in Gewerbe-, Handwerks- oder Industriebetrieben sowie bei gleichzusetzenden Tätigkeiten eingesetzt wird.
5. Vor Inbetriebnahme
Überzeugen Sie sich vor dem Anschließen, dass die Daten auf dem Typenschild mit den Netzdaten übereinstimmen.
Überprüfen Sie das Gerät auf Transportschä-
den. Etwaige Schäden sofort dem Transport­unternehmen melden, mit dem der Kompres­sor angeliefert wurde. Die Aufstellung des Kompressors sollte in der
Nähe des Verbrauchers erfolgen. Lange Luftleitungen und lange Zuleitungen
(Verlängerungskabel) sind zu vermeiden. Auf trockene und staubfreie Ansaugluft ach-
ten. Den Kompressor nicht in feuchtem oder nas-
sem Raum aufstellen. Der Kompressor darf nur in geeigneten Räu-
men (gut belüftet, Umgebungstemperatur +5°C bis 40°C) betrieben werden. Im Raum dürfen sich keine Stäube, keine Säuren, Dämpfe, explosive oder entflammbare Gase befinden. Der Kompressor ist geeignet für den Einsatz
in trockenen Räumen. In Bereichen, in denen mit Spritzwasser gearbeitet wird, ist der Ein-
- 7 -
Anl_TE_AC_270_24_10_SPK1.indb 7Anl_TE_AC_270_24_10_SPK1.indb 7 19.09.13 18:2319.09.13 18:23
D
satz nicht zulässig. Vor Inbetriebnahme muss der Ölstand in der
Kompressorpumpe kontrolliert werden. Betreiben Sie das Gerät nur auf festem, ebe-
nem Untergrund Verwenden Sie flexible Schläuche um eine
Übertragung von unzulässigen Lasten auf das Rohrleitungssystem an der Verbindung der Kompressoranlage zum Rohrleitungssys­tem zu vermeiden. Es ist notwenig Abscheider, Fänger und
Abflussmöglichkeiten zu verwenden, die zur Bearbeitung der vom Kompressor produ­zierten Flüssigkeiten vor Inbetriebsetzen der Kompressoranlage erforderlich sind. Zuführschläuche bei Drücken über 7 bar soll-
ten mit einem Sicherheitskabel (z. B. einem Drahtseil) ausgestattet werden.
6. Montage und Inbetriebnahme
 Achtung! Vor der Inbetriebnahme das Gerät unbedingt komplett montieren!
6.1. Montage der Räder (3)
Die beiliegenden Räder müssen entsprechend Bild 5 montiert werden.
6.2 Montage der Standfüße (4)
Die beiliegenden Standfüße (4) müssen entspre­chend Bild 6 montiert werden.
6.3 Montage des Transportgriff es (9)
Den Transportgriff (9) wie in Bild 7 bis 8 gezeigt am Kompressor verschrauben.
6.4. Austausch des Öl-Verschlussstopfens
(14)
Entfernen Sie mit einem Schraubenzieher den Transportdeckel der Öleinfüllöff nung und setzen Sie den beiliegenden Öl-Verschlussstopfen (14) in die Öleinfüllöff nung ein (Abb. 9/11).
6.5 Montage des Luftfi lters (1)
Entfernen Sie mit einem Schraubenzieher den Transportdeckel am Luftfi lteranschluß. Schrauben Sie den beiliegenden Luftfi lter ein (Abb. 10).
6.6. Netzanschluß
Der Motor ist mit einem Überlastschalter
ausgestattet (Bild 3/Pos. 16). Bei Überlastung des Kompressors schaltet der Überlastschal­ter automatisch ab, um den Kompressor vor Überhitzung zu schützen. Sollte der Überlast­schalter ausgelöst haben, schalten Sie den Kompressor am Ein-/Ausschalter (8) ab und warten Sie ab bis der Kompressor abgekühlt ist. Drücken Sie nun den Überlastschalter (16) ein und Schalten Sie den Kompressor wieder an. Lange Zuleitungen, sowie Verlängerungen,
Kabeltrommeln usw. verursachen Span­nungsabfall und können den Motoranlauf verhindern. Bei niedrigen Temperaturen unter +5°C ist
der Motoranlauf durch Schwergängigkeit ge­fährdet.
6.7 Aus-/ Einschalter (8)
Durch Herausziehen des Knopfes (8) wird der Kompressor eingeschaltet. Zum Ausschalten des Kompressors muss der Knopf (8) gedrückt werden. (Bild 2)
6.8 Druckeinstellung: (Abb. 1,2)
Mit dem Druckregler (7) kann der Druck am
Manometer (6) eingestellt werden. Der eingestellte Druck kann an der Schnell-
kupplung (5) entnommen werden.
6.9 Druckschaltereinstellung
Der Druckschalter ist werkseitig eingestellt. Einschaltdruck ca. 8 bar Ausschaltdruck ca. 10 bar
7. Austausch der Netzanschlussleitung
Wenn die Netzanschlussleitung dieses Gerätes beschädigt wird, muss sie durch den Hersteller oder seinen Kundendienst oder eine ähnlich qua­lifi zierte Person ersetzt werden, um Gefährdun- gen zu vermeiden.
- 8 -
Anl_TE_AC_270_24_10_SPK1.indb 8Anl_TE_AC_270_24_10_SPK1.indb 8 19.09.13 18:2319.09.13 18:23
D
8. Reinigung, Wartung und Ersatzteilbestellung
 Achtung! Ziehen Sie vor allen Reinigungs- und War­tungsarbeiten den Netzstecker.
Achtung!
Warten Sie bis der Verdichter vollständig ab­gekühlt ist! Verbrennungsgefahr!
Achtung!
Vor allen Reinigungs- und Wartungsarbeiten ist der Kessel drucklos zu machen.
Achtung!
Schalten Sie nach der Benutzung das Gerät immer aus und ziehen Sie den Netzstecker.
8.1 Reinigung
Halten Sie Schutzvorrichtungen, Luftschlitze
und Motorengehäuse so staub- und schmutz­frei wie möglich. Reiben Sie das Gerät mit einem sauberen Tuch ab oder blasen Sie es mit Druckluft bei niedrigem Druck aus. Wir empfehlen, dass Sie das Gerät direkt
nach jeder Benutzung reinigen. Reinigen Sie das Gerät regelmäßig mit einem
feuchten Tuch und etwas Schmierseife. Ver­wenden Sie keine Reinigungs- oder Lösungs­mittel; diese könnten die Kunststoffteile des Gerätes angreifen. Achten Sie darauf, dass kein Wasser in das Geräteinnere gelangen kann. Das Eindringen von Wasser in ein Elek­trogerät erhöht das Risiko eines elektrischen Schlages. Schlauch und Spritzwerkzeuge müssen vor
Reinigung vom Kompressor getrennt werden. Der Kompressor darf nicht mit Wasser, Lö­sungsmitteln o. Ä. gereinigt werden.
8.2 Kondenswasser (Abb. 1)
Achtung! Für dauerhafte Haltbarkeit des Druckbe­hälters (2) ist nach jedem Betrieb das Kondens­wasser durch Öff nen der Ablassschraube(11) abzulassen. Kontrollieren Sie den Druckbehälter vor jedem Betrieb auf Rost und Beschädigungen. Der Kom­pressor darf nicht mit einem beschädigten oder rostigen Druckbehälter betrieben werden. Stellen Sie Beschädigungen fest, so wenden sie sich bit­te an die Kundendienstwerkstatt.
Achtung!
Das Kondenswasser aus dem Druckbehälter enthält Ölrückstände. Entsorgen Sie das Kondenswasser umweltgerecht bei einer ent­sprechenden Sammelstelle.
8.3 Sicherheitsventil (10)
Das Sicherheitsventil ist auf den höchstzulässi­gen Druck des Druckbehälters eingestellt. Es ist nicht zulässig, das Sicherheitsventil zu verstellen oder dessen Plombe zu entfernen. Damit das Sicherheitsventil im Bedarfsfall richtig funktioniert, sollte dies von Zeit zu Zeit betätigt werden. Zie­hen Sie so stark am Ring, bis die Druckluft hörbar abbläst. Anschließend lassen Sie den Ring wie­der los.
8.4 Ölstand regelmäßig kontrollieren
Kompressor auf eine ebene, gerade Fläche stel­len. Der Ölstand muss sich zwischen MAX und MIN des Schauglases (Abb. 12) befi nden. Ölwechsel: Empfohlenes Öl: SAE 5W/40 oder gleichwertiges. Die Erstfüllung soll nach 100 Betriebsstunden gewechselt werden. Danach ist alle 500 Betriebs­stunden das Öl abzulassen und neues nachzu­füllen.
Anl_TE_AC_270_24_10_SPK1.indb 9Anl_TE_AC_270_24_10_SPK1.indb 9 19.09.13 18:2319.09.13 18:23
8.5 Ölwechsel
Schalten Sie den Motor ab und ziehen Sie den Netzstecker aus der Steckdose. Nachdem Sie den eventuell vorhandenen Luftdruck abgelassen haben, können Sie die Öl-Ablassschraube (15) an der Verdichterpumpe herausschrauben. Damit das Öl nicht unkontrolliert herausläuft, halten Sie eine kleine Blechrinne darunter und fangen Sie das Öl in einem Behälter auf. Falls das Öl nicht vollständig herausläuft, empfehlen wir den Kom­pressor ein wenig zu neigen.
- 9 -
D
Das Altöl entsorgen Sie bei einer entspre­chenden Annahmestelle für Altöl.
Ist das Öl herausgelaufen, setzen Sie die Öl-Ab­lassschraube (15) wieder ein. Füllen Sie das neue Öl in die Öleinfüllöff nung (27) ein, bis der Ölstand das Soll erreicht hat. Anschließend setzen Sie den Öl-Verschlussstopfen (14) wieder ein.
8.6 Reinigen des Ansaugfi lters (1)
Der Ansaugfi lter verhindert das Einsaugen von Staub und Schmutz. Es ist notwendig, diesen Filter mindestens alle 300 Betriebsstunden zu rei­nigen. Ein verstopfter Ansaugfi lter vermindert die Leistung des Kompressors erheblich. Öff nen Sie die Schraube am Luftfi lter, so dass die Gehäu- sehälften des Luftfi lters geöff net werden können. Blasen Sie alle Teile des Filters mit Druckluft bei niedrigem Druck (ca. 3 bar) aus und montieren Sie dann den Filter in umgekehrter Reihenfolge. Achten Sie bei der Reinigung auf ausreichenden Schutz gegen Staub (z.B. geeigneter Mund­schutz).
8.7 Lagerung
Achtung!
Ziehen Sie den Netzstecker, entlüften Sie das Gerät und alle angeschlossenen Druckluftwerk­zeuge. Stellen Sie den Kompressor so ab, dass dieser nicht von Unbefugten in Betrieb genom­men werden kann.
Achtung!
Den Kompressor nur in trockener und für Unbefugte unzugänglicher Umgebung auf­bewahren. Nicht kippen, nur stehend aufbe­wahren!
9. Entsorgung und Wiederverwertung
Das Gerät befi ndet sich in einer Verpackung um Transportschäden zu verhindern. Diese Verpa­ckung ist Rohstoff und ist somit wieder verwend- bar oder kann dem Rohstoff kreislauf zurückge- führt werden. Das Gerät und dessen Zubehör bestehen aus verschiedenen Materialien, wie z.B. Metall und Kunststoff e. Defekte Geräte ge- hören nicht in den Hausmüll. Zur fachgerechten Entsorgung sollte das Gerät an einer geeigneten Sammelstellen abgegeben werden. Wenn Ihnen keine Sammelstelle bekannt ist, sollten Sie bei der Gemeindeverwaltung nachfragen.
8.8 Ersatzteilbestellung:
Bei der Ersatzteilbestellung sollten folgende An­gaben gemacht werden;
Typ des Gerätes
Artikelnummer des Gerätes
Ident-Nummer des Gerätes
Ersatzteilnummer des erforderlichen Ersatz-
teils Aktuelle Preise und Infos fi nden Sie unter www.isc-gmbh.info
- 10 -
Anl_TE_AC_270_24_10_SPK1.indb 10Anl_TE_AC_270_24_10_SPK1.indb 10 19.09.13 18:2319.09.13 18:23
D
10. Mögliche Ausfallursachen
Problem Ursache Lösung
Kompressor läuft nicht
Kompressor läuft, jedoch kein Druck
Kompressor läuft, Druck wird am Ma­nometer angezeigt, jedoch Werkzeuge laufen nicht.
1. Netzspannung nicht vorhanden
2. Netzspannung zu niedrig
3. Außentemperatur zu niedrig
4. Motor überhitzt
1. Rückschlagventil undicht
2. Dichtungen kaputt.
3. Ablass-Schraube für Kondens­wasser (11) undicht.
1. Schlauchverbindungen undicht.
2. Schnellkupplung undicht.
3. Zu wenig Druck am Druckregler eingestellt.
1. Kabel, Netzstecker, Sicherung und Steckdose überprüfen.
2. Zu lange Verlängerungskabel
vermeiden. Verlängerungs-kabel
mit ausreichendem Aderquerschnitt verwenden.
3. Nicht unter +5° C Außentemperatur betreiben.
4. Motor abkühlen lassen ggf. Ursa­che der Überhitzung beseitigen.
1. Rückschlagventil austauschen.
2. Dichtungen überprüfen, kaputte Dichtungen bei einer Fachwerkstatt ersetzen lassen.
3. Schraube per Hand nachziehen. Dichtung auf der Schraube über­prüfen, ggf. ersetzen.
1. Druckluftschlauch und Werk-
zeuge überprüfen, ggf. aus­ tauschen.
2. Schnellkupplung überprüfen,
ggf. ersetzen.
3. Druckregler weiter aufdrehen.
- 11 -
Anl_TE_AC_270_24_10_SPK1.indb 11Anl_TE_AC_270_24_10_SPK1.indb 11 19.09.13 18:2319.09.13 18:23
D
Nur für EU-Länder
Werfen Sie Elektrowerkzeuge nicht in den Hausmüll!
Gemäß europäischer Richtlinie 2002/96/EG über Elektro- und Elektronik-Altgeräte und Umsetzung in nationales Recht müssen verbrauchte Elektrowerkzeuge getrennt gesammelt werden und einer umwelt­gerechten Wiederverwertung zugeführt werden.
Recycling-Alternative zur Rücksendeauff orderung: Der Eigentümer des Elektrogerätes ist alternativ anstelle Rücksendung zur Mitwirkung bei der sachge­rechten Verwertung im Falle der Eigentumsaufgabe verpfl ichtet. Das Altgerät kann hierfür auch einer Rücknahmestelle überlassen werden, die eine Beseitigung im Sinne der nationalen Kreislaufwirt­schafts- und Abfallgesetze durchführt. Nicht betroff en sind den Altgeräten beigefügte Zubehörteile und Hilfsmittel ohne Elektrobestandteile.
Der Nachdruck oder sonstige Vervielfältigung von Dokumentation und Begleitpapieren der Produkte, auch auszugsweise, ist nur mit ausdrücklicher Zustimmung der iSC GmbH zulässig.
Technische Änderungen vorbehalten
- 12 -
Anl_TE_AC_270_24_10_SPK1.indb 12Anl_TE_AC_270_24_10_SPK1.indb 12 19.09.13 18:2319.09.13 18:23
D
- 13 -
Anl_TE_AC_270_24_10_SPK1.indb 13Anl_TE_AC_270_24_10_SPK1.indb 13 19.09.13 18:2319.09.13 18:23
D
Garantiebestimmungen
Die Fa. iSC GmbH bzw. der zuständige Baumarkt garantiert die Behebung von Mängeln bzw. den Gerä­teaustausch entsprechend der unten stehenden Übersicht, wobei die gesetzlichen Gewährleistungsan­sprüche unberührt bleiben.
Kategorie Beispiel Garantieleistung
Mängel an Material oder Kons­truktion
Verschleißteile* Keilriemen, Luftfi lter 6 Monate Verbrauchsmaterial/
Verbrauchsteile*
Fehlteile 5 Arbeitstage
* nicht zwingend im Lieferumfang enthalten!
Bezüglich Verschleißteilen, Verbrauchsmaterial und Fehlteilen garantiert die Fa. iSC GmbH bzw. der zuständige Baumarkt eine Mängelbehebung bzw. eine Nachlieferung nur, wenn der Mangel innerhalb von 24h (Verbrauchsmaterial), 5 Arbeitstagen (Fehlteilen) oder 6 Monaten (Verschleißteile) nach Kauf angezeigt und das Kaufdatum durch Kaufbeleg nachgewiesen wird.
Bei Mängeln an Material oder Konstruktion, bitten wir Sie im Garantiefall das Gerät zusammen mit bei­liegender Gerätekarte einzureichen und diese vollständig auszufüllen. Wichtig ist hierbei eine genaue Fehlerbeschreibung anzugeben.
24 Monate
Garantie nur bei Sofortdefekt (24h nach Kauf / Kaufbelegda­tum)
Beantworten Sie hierfür folgende Fragen:
Hat das Gerät bereits einmal funktioniert oder war es von Anfang an defekt?
Ist Ihnen vor dem Auftreten des Defektes etwas aufgefallen (Symptom vor Defekt)?
Welche Fehlfunktion weist das Gerät Ihrer Meinung nach auf (Hauptsymptom)?
Beschreiben Sie diese Fehlfunktion.
- 14 -
Anl_TE_AC_270_24_10_SPK1.indb 14Anl_TE_AC_270_24_10_SPK1.indb 14 19.09.13 18:2319.09.13 18:23
D
Garantieurkunde
Sehr geehrte Kundin, sehr geehrter Kunde, unsere Produkte unterliegen einer strengen Qualitätskontrolle. Sollte dieses Gerät dennoch einmal nicht einwandfrei funktionieren, bedauern wir dies sehr und bitten Sie, sich an unseren Servicedienst unter der auf dieser Garantiekarte angegebenen Adresse zu wenden. Gern stehen wir Ihnen auch telefonisch über die untenangegebene Servicerufnummer zur Verfügung. Für die Geltendmachung von Garantiean­sprüchen gilt folgendes:
1. Diese Garantiebedingungen regeln zusätzliche Garantieleistungen. Ihre gesetzlichen Gewährleis­tungsansprüche werden von dieser Garantie nicht berührt. Unsere Garantieleistung ist für Sie kostenlos.
2. Die Garantieleistung erstreckt sich ausschließlich auf Mängel, die auf Material- oder Herstellungs­fehler zurückzuführen sind und ist auf die Behebung dieser Mängel bzw. den Austausch des Gerä­tes beschränkt. Bitte beachten Sie, dass unsere Geräte bestimmungsgemäß nicht für den gewerb­lichen, handwerklichen oder industriellen Einsatz konstruiert wurden. Ein Garantievertrag kommt daher nicht zustande, wenn das Gerät in Gewerbe-, Handwerks- oder Industriebetrieben sowie bei gleichzusetzenden Tätigkeiten eingesetzt wird.
Von unserer Garantie sind ferner Ersatzleistungen für Transportschäden, Schäden durch Nichtbe-
achtung der Montageanleitung oder aufgrund nicht fachgerechter Installation, Nichtbeachtung der Gebrauchsanleitung (wie durch z.B. Anschluss an eine falsche Netzspannung oder Stromart), miss­bräuchliche oder unsachgemäße Anwendungen (wie z.B. Überlastung des Gerätes oder Verwen­dung von nicht zugelassenen Einsatzwerkzeugen oder Zubehör), Nichtbeachtung der Wartungs­und Sicherheitsbestimmungen, Eindringen von Fremdkörpern in das Gerät (wie z.B. Sand, Steine oder Staub), Gewaltanwendung oder Fremdeinwirkungen (wie z. B. Schäden durch Herunterfallen) sowie durch verwendungsgemäßen, üblichen Verschleiß ausgeschlossen. Dies gilt insbesondere für Akkus, auf die wir dennoch eine Garantiezeit von 12 Monaten gewähren. Der Garantieanspruch erlischt, wenn an dem Gerät bereits Eingriff e vorgenommen wurden.
3. Die Garantiezeit beträgt 2 Jahre und beginnt mit dem Kaufdatum des Gerätes. Garantieansprüche sind vor Ablauf der Garantiezeit innerhalb von zwei Wochen, nachdem Sie den Defekt erkannt haben, geltend zu machen. Die Geltendmachung von Garantieansprüchen nach Ablauf der Ga­rantiezeit ist ausgeschlossen. Die Reparatur oder der Austausch des Gerätes führt weder zu einer Verlängerung der Garantiezeit noch wird eine neue Garantiezeit durch diese Leistung für das Gerät oder für etwaige eingebaute Ersatzteile in Gang gesetzt. Dies gilt auch bei Einsatz eines Vor-Ort­Services.
4. Für die Geltendmachung Ihres Garantieanspruches übersenden Sie bitte das defekte Gerät porto­frei an die unten angegebene Adresse. Fügen Sie den Verkaufsbeleg im Original oder einen sonsti­gen datierten Kaufnachweis bei. Bitte bewahren Sie deshalb den Kassenbon als Nachweis gut auf! Beschreiben Sie uns bitte den Reklamationsgrund möglichst genau. Ist der Defekt des Gerätes von unserer Garantieleistung erfasst, erhalten Sie umgehend ein repariertes oder neues Gerät zurück.
Selbstverständlich beheben wir gegen Erstattung der Kosten auch gerne Defekte am Gerät, die vom Garantieumfang nicht oder nicht mehr erfasst sind. Dazu senden Sie das Gerät bitte an unsere Service­adresse.
Für Verschleiß-/Verbrauchs- und Fehlteile verweisen wir auf die Einschränkungen dieser Garantie ge­mäß den Garantiebestimmungen dieser Bedienungsanleitung.
iSC GmbH · Eschenstraße 6 · 94405 Landau/Isar (Deutschland)
Telefon: +49 [0] 180 5 011 843 · Telefax +49 [0] 180 5 835 830
(Festnetzpreis: 14 ct/min, Mobilfunkpreise maximal: 42 ct/min)
Außerhalb Deutschlands fallen stattdessen Gebühren für ein reguläres Gespräch ins dt. Festnetz an.
E-Mail: info@isc-gmbh.info · Internet: www.isc-gmbh.info
- 15 -
Anl_TE_AC_270_24_10_SPK1.indb 15Anl_TE_AC_270_24_10_SPK1.indb 15 19.09.13 18:2319.09.13 18:23
Garantie JA NEIN Kaufbeleg-Nr. / Datum:
1
3
Fehlerbeschreibung und Art.-Nr. und I.-Nr. angeben l
4
Garantiefall JA/NEIN ankreuzen sowie Kaufbeleg-Nr. und Datum angeben und eine Kopie des Kaufbeleges beilegen
4
Service Hotline kontaktieren oder bei iSC-Webadresse anmelden - es wird Ihnen eine Retourennummer zugeteilt l
Sehr geehrte Kundin, sehr geehrter Kunde,
bitte beschreiben Sie uns die von Ihnen festgestellte Fehlfunktion Ihres Gerätes als Grund Ihrer Beanstandung möglichst genau. Dadurch können wir für Sie Ihre Reklamation schneller bearbeiten
und Ihnen schneller helfen. Eine zu ungenaue Beschreibung mit Begriff en wie „Gerät funktioniert nicht“ oder „Gerät defekt“ verzögert hingegen die Bearbeitung erheblich.
D
PLZ: Ort:
3
Welcher Fehler ist aufgetreten (genaue Angabe): Art.-Nr.: I.-Nr.:
Straße / Nr.:
2
Name:
(Festnetzpreis: 14 ct/min, Mobilfunkpreise maximal: 42 ct/min; Außerhalb Deutschlands fallen stattdessen Gebühren für ein reguläres Gespräch ins dt. Festnetz an.)
1
Service Hotline: 01805 011 843 · www.isc-gmbh.info · Mo-Fr 8:00-18:00 Uhr
Mobil:
2
Ihre Anschrift eintragen
- 16 -
Anl_TE_AC_270_24_10_SPK1.indb 16Anl_TE_AC_270_24_10_SPK1.indb 16 19.09.13 18:2319.09.13 18:23
Telefon:
Retouren-Nr. iSC:
GB
Caution - Read the operating instructions to reduce the risk of inquiry
Wear ear-muff s. The impact of noise can cause damage to hearing.
Beware of electrical voltage!
Beware of hot parts!
Warning! The equipment is remote-controlled and may start-up without warning.
Caution! Before using for the rst time, check the oil level and replace the oil sealing plug!
Prohibited! Do not use the equipment with open doors or an open housing.
- 17 -
Anl_TE_AC_270_24_10_SPK1.indb 17Anl_TE_AC_270_24_10_SPK1.indb 17 19.09.13 18:2319.09.13 18:23
GB
 Important!
When using the equipment, a few safety pre­cautions must be observed to avoid injuries and damage. Please read the complete operating instructions and safety regulations with due care. Keep this manual in a safe place, so that the in­formation is available at all times. If you give the equipment to any other person, hand over these operating instructions and safety regulations as well. We cannot accept any liability for damage or accidents which arise due to a failure to follow these instructions and the safety instructions.
1. Safety regulations
The corresponding safety information can be found in the enclosed booklet.
Caution!
Read all safety regulations and instructions.
Any errors made in following the safety regula­tions and instructions may result in an electric shock, fi re and/or serious injury.
Keep all safety regulations and instructions in a safe place for future use.
This appliance is not intended for use by persons (including children) with reduced physical, sen­sory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
2. Layout and items supplied
2.1 Layout (Fig. 1-4)
1. Intake air fi lter
2. Pressure tank
3. Wheel
4. Foot
5. Quick-lock coupling (regulated compressed air)
6. Pressure gauge (for reading the set pressure)
7. Pressure regulator
8. On/Off switch
9. Transport handle
10. Safety valve
11. Drainage screw for condensation water
12. Pressure gauge (for reading the vessel pres­sure)
13. Quick-lock coupling (unregulated com­pressed air)
14. Oil sealing plug
15. Oil drainage screw
16. Overload switch
17. Oil level window
18. Wheel cap
19. Screw (internal hexagon) for fi tting the handle
20. Wrench (hexagon)
21. Screw
22. Washer
23. Nut
24. Axle screw
25. Spring washer
26. Nut
27. Oil fi ller opening
2.2 Items supplied
Please check that the article is complete as spe­cifi ed in the scope of delivery. If parts are missing, please contact our service center or the nearest branch of the DIY store where you made your purchase at the latest within 5 work days after purchasing the article and upon presentation of a valid bill of purchase. Also, refer to the warranty table in the warranty provisions at the end of the operating instructions.
Open the packaging and take out the equip-
ment with care. Remove the packaging material and any
packaging and/or transportation braces (if available). Check to see if all items are supplied.
Inspect the equipment and accessories for
transport damage. If possible, please keep the packaging until
the end of the guarantee period.
Important! The equipment and packaging material are not toys. Do not let children play with plastic bags, foils or small parts. There is a danger of swallowing or suff ocating!
Intake air filter
Wheel (2x)
Foot
Transport handle
Oil sealing plug
Wheel cap (2x)
Screw (internal hexagon) for fitting the handle
(4x) Wrench (hexagon)
Screw
Washer (6x)
- 18 -
Anl_TE_AC_270_24_10_SPK1.indb 18Anl_TE_AC_270_24_10_SPK1.indb 18 19.09.13 18:2319.09.13 18:23
GB
Nut for fitting the foot
Axle screw (2x)
Spring washer (2x)
Nut for fitting the axle (2x)
Original operating instructions
Safety information
3. Proper use
The compressor is designed for generating compressed air for tools operated by compressed air.
The equipment is to be used only for its prescri­bed purpose. Any other use is deemed to be a case of misuse. The user / operator and not the manufacturer will be liable for any damage or inju­ries of any kind caused as a result of this.
Please note that our equipment has not been de­signed for use in commercial, trade or industrial applications. Our warranty will be voided if the machine is used in commercial, trade or industrial businesses or for equivalent purposes.
4. Technical data
Mains connection: ........................ 230 V ~ 50 Hz
Motor rating: ........................................... 1800 W
Compressor speed min
Operating pressure bar: ..........................max. 10
Pressure vessel capacity (in liters): ................ 24
Theoretical suction rate l/min.: ..................... 270
Output (compressed air) at 7 bar: ..100 liters/min Output (compressed air) at 4 bar: ..127 liters/min Sound power level L
uncertainty ........................................1.98 dB
K
WA
Sound pressure level L
uncertainty ........................................1.98 dB
K
pA
Protection type: ........................................... IP20
Weight of the unit in kg: ................. approx. 27 kg
Oil quantity: ............................. approx. 0.23 liters
-1
: ........................... 2850
in dB: .......................... 94
WA
in dB: ...................... 72
pA
5. Before starting the equipment
Before you connect the equipment to the mains supply make sure that the data on the rating plate are identical to the mains data.
Examine the machine for signs of transit da-
mage. Report any damage immediately to the company which delivered the compressor. The compressor should be set up near the
working consumer. Avoid long air lines and long supply lines (ex-
tensions). Make sure the intake air is dry and dust-free.
Do not set up the compressor in damp or wet
rooms. The compressor may only be used in suitable
rooms (with good ventilation and an ambient temperature from +5°C to +40°C). There must be no dust, acids, vapors, explosive gases or inflammable gases in the room. The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in areas where work is conducted with spray­ed water. The oil level in the compressor pump has to
be checked before putting the equipment into operation. The equipment must be set up where it can
stand securely. Use flexible hoses in order to prevent trans-
mitting unacceptable loads to the pipeline system at the connection between the com­pressor system and the pipeline system. It is essential to use separators, traps and
drains which process the liquids produced by the compressor before the compressor sys­tem is put into operation. Supply hoses at pressures above 7 bar
should be equipped with a safety cable (e.g. a wire rope).
Noise
The noise emission values were measured in ac­cordance with EN ISO 2151.
- 19 -
Anl_TE_AC_270_24_10_SPK1.indb 19Anl_TE_AC_270_24_10_SPK1.indb 19 19.09.13 18:2319.09.13 18:23
GB
6. Assembly and starting
 Important! You must fully assemble the appliance before
using it for the fi rst time.
6.1 Fitting the wheels (3)
Fit the supplied wheels as shown in Fig. 5.
6.2 Fitting the supporting feet (4)
Fit the supplied supporting feet (4) as shown in Fig. 6.
6.3 Fitting the transport handle (9)
Screw the transport handle (9) to the compressor as shown in Figures 7 to 8.
6.4. Replacing the oil sealing plug (14)
Remove the transportation cover from the oil fi ller opening with a screwdriver and insert the sup­plied oil sealing plug (14) into the oil fi ller opening (Fig. 9/11).
6.5 Fitting the air fi lter (1)
Use a screwdriver to remove the transportation cover from the air fi lter connection. Screw in the supplied air fi lter (Fig. 10).
6.6. Power supply
The motor is fitted with an overload switch
(Fig. 3/Item 6). If the compressor overloads, the overload switch switches off the equip­ment automatically to protect the compressor from overheating. If the overload switch trig­gers, switch off the compressor using the ON/ OFF switch (8) and wait until the compressor cools down. Then press the overload switch (16) and restart the compressor. Long supply cables, extensions, cable reels
etc. cause a drop in voltage and can impede motor start-up. In the case of low temperatures below +5°C,
motor start-up is jeopardized as a result of stiffness.
6.7 On/Off switch (8)
To switch on the compressor, pull out the knob (8). To switch off the compressor, press the knob (8) back in. (Figure 2)
6.8 Adjusting the pressure: (Fig. 1,2)
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7). The set pressure can be taken from the quick-
lock coupling (5).
6.9 Setting the pressure switch
The pressure switch is set at the factory. Switch-on pressure 8 bar Switch-off pressure 10 bar
7. Replacing the power cable
If the power cable for this equipment is damaged, it must be replaced by the manufacturer or its after-sales service or similarly trained personnel to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Important!
Pull the power plug before doing any cleaning and maintenance work on the ap­pliance.
Important!
Wait until the compressor has completely cooled down. Risk of burns!
Important!
Always depressurize the tank before carrying out any cleaning and maintenance work.
Important!
After use, always switch off the equipment immediately and pull out the power plug.
8.1 Cleaning
Keep the safety devices free of dirt and dust
as far as possible. Wipe the equipment with a clean cloth or blow it with compressed air at low pressure. We recommend that you clean the appliance
immediately after you use it. Clean the appliance regularly with a damp
cloth and some soft soap. Do not use cleaning agents or solvents; these may be aggressive to the plastic parts in the appli­ance. Ensure that no water can get into the interior of the appliance. You must disconnect the hose and any
spraying tools from the compressor before cleaning. Do not clean the compressor with
- 20 -
Anl_TE_AC_270_24_10_SPK1.indb 20Anl_TE_AC_270_24_10_SPK1.indb 20 19.09.13 18:2319.09.13 18:23
GB
water, solvents or the like.
8.2 Condensation water (Fig. 1)
Important. To ensure a long service life of the pressure vessel (2), drain off the condensed wa- ter by opening the drain valve (11) each time after using. Check the pressure vessel for signs of rust and damage each time before using. Do not use the compressor with a damaged or rusty pressure vessel. If you discover any damage, please con­tact the customer service workshop.
Important!
The condensation water from the pressure vessel will contain residual oil. Dispose of the condensation water in an environmentally compatible manner at the appropriate collec­tion point.
8.3 Safety valve (10)
The safety valve has been set for the highest per­mitted pressure of the pressure vessel. It is prohi­bited to adjust the safety valve or remove its seal. Actuate the safety valve from time to time to en­sure that it works when required. Pull the ring with suffi cient force until you can hear the compressed air being released. Then release the ring again.
8.4 Check the oil level at regular intervals
Place the compressor on a level and straight sur­face. The oil level must be between the two marks MAX and MIN on the oil oil level window (Fig. 12). Changing the oil: Recommended hydraulic oil: SAE 5W/40 or an alternative of the same quality. It should be refi lled for the fi rst time after 100 hours of operation. Thereafter the oil should be drained and refi lled after every 500 hours in ser- vice.
8.5 Changing the oil
Switch off the engine and pull the mains plug out of the socket. After releasing any air pressure you can unscrew the oil drainage screw (15) from the compressor pump. To prevent the oil from running out in an uncontrolled manner, hold a small metal chute under the opening and collect the oil in a vessel. If the oil does not drain out completely, we recommend tilting the compressor slightly.
Dispose of the old oil at a drop-off point for old oil.
When the oil has drained out, re-fi t the oil draina- ge screw (15). Fill new oil through the oil fi ller ope- ning (27) until it comes up to the required level. Then replace the oil sealing plug (14).
8.6 Cleaning the intake fi lter (1)
The intake fi lter prevents dust and dirt being drawn in. It is essential to clean this fi lter after at least every 300 hours in operation. A clogged intake fi lter will decrease the compressor‘s per- formance dramatically. Undo the screw on the air fi lter so that the halves of the air fi lter housing can be opened. Use compressed air at low pres­sure (approx. 3 bar) to blow out all the parts of the fi lter and then assemble the fi lter in reverse order. When cleaning, take adequate precautions against dust (e.g. use a suitable face mask).
8.7 Storage
Important!
Pull the mains plug out of the socket and ventilate the appliance and all connected pneumatic tools. Switch off the compressor and make sure that it is secured in such a way that it cannot be started up again by any unauthorized person.
Important!
Store the compressor only in a dry location which is not accessible to unauthorized per­sons. Always store upright, never tilted!
8.8 Ordering replacement parts:
Please quote the following data when ordering replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to www.isc-gmbh.info
9. Disposal and recycling
The equipment is supplied in packaging to pre­vent it from being damaged in transit. The raw materials in this packaging can be reused or recycled. The equipment and its accessories are made of various types of material, such as metal and plastic. Never place defective equipment in your household refuse. The equipment should be taken to a suitable collection center for proper disposal. If you do not know the whereabouts of such a collection point, you should ask in your local council offi ces.
- 21 -
Anl_TE_AC_270_24_10_SPK1.indb 21Anl_TE_AC_270_24_10_SPK1.indb 21 19.09.13 18:2319.09.13 18:23
GB
10. Possible causes of failure
Problem Cause Solution
The compressor does not start.
The compressor starts but there is no pressure.
The compressor starts, pressure is shown on the pres­sure gauge, but the tools do not start.
1. No supply voltage.
2. Insuffi cient supply voltage.
3. Outside temperature is too low.
4. Motor is overheated.
1. The non-return valve leaks.
2. The seals are damaged.
3. The drain plug for condensation water (11) leaks.
1. The hose connections have a leak.
2. A quick-lock coupling has a leak.
3. Insuffi cient pressure set on the pressure regulator.
1. Check the supply voltage, the pow­er plug and the socket-outlet.
2. Make sure that the extension cable is not too long. Use an extension cable with large enough wires.
3. Never operate with an outside tem­perature of below +5° C.
4. Allow the motor to cool down. If necessary, remedy the cause of the overheating.
1. Have a service center replace the non-return valve.
2. Check the seals and have any da­maged seals replaced by a service center.
3. Tighten the screw by hand. Check the seal on the screw and replace if necessary.
1. Check the compressed air hose and tools and replace if necessary.
2. Check the quick-lock coupling and replace if necessary.
3. Increase the set pressure with the pressure regulator.
- 22 -
Anl_TE_AC_270_24_10_SPK1.indb 22Anl_TE_AC_270_24_10_SPK1.indb 22 19.09.13 18:2319.09.13 18:23
GB
For EU countries only
Never place any electric power tools in your household refuse.
To comply with European Directive 2002/96/EC concerning old electric and electronic equipment and its implementation in national laws, old electric power tools have to be separated from other waste and disposed of in an environment-friendly fashion, e.g. by taking to a recycling depot.
Recycling alternative to the return request: As an alternative to returning the equipment to the manufacturer, the owner of the electrical equipment must make sure that the equipment is properly disposed of if he no longer wants to keep the equipment. The old equipment can be returned to a suitable collection point that will dispose of the equipment in accordance with the national recycling and waste disposal regulations. This does not apply to any ac­cessories or aids without electrical components supplied with the old equipment.
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers accompanying products is permitted only with the express consent of the iSC GmbH.
Subject to technical changes
- 23 -
Anl_TE_AC_270_24_10_SPK1.indb 23Anl_TE_AC_270_24_10_SPK1.indb 23 19.09.13 18:2319.09.13 18:23
GB
Warranty provisions
iSC GmbH or the DIY store where you made you purchase guarantees the repair of defects or replace­ment of the equipment in accordance with the overview below. Statutory guarantee claims are unaff ec- ted.
Category Example Warranty
Defect with regard to material or construction
Wear parts* V-belt, air fi lter 6 months Consumables* Warranty only in case of an im-
Missing parts 5 work days
* Not necessarily included in the scope of delivery!
For consumables, wear parts and missing parts iSC GmbH guarantees the correction of defects or a new delivery only if the defect is reported within 24 hours (consumables), 5 work days (missing parts) or 6 months (wear parts) after purchase and the purchase date is verifi ed with the bill.
In case of defects concerning the material or construction, we kindly request you to submit the equip­ment together with the fully completed warranty card supplied with the equipment. It is important that you enter an exact description of the defect.
To do so, answer the following questions:
Did the equipment work at all or was it defective from the beginning?
Did you notice anything (symptom or defect) prior to the failure?
What malfunction does the equipment have in your opinion (main symptom)?
Describe this malfunction.
24 months
mediate defect (24 hours after purchase / date on the bill)
- 24 -
Anl_TE_AC_270_24_10_SPK1.indb 24Anl_TE_AC_270_24_10_SPK1.indb 24 19.09.13 18:2319.09.13 18:23
GB
Warranty certifi cate
Dear Customer, All of our products undergo strict quality checks to ensure that they reach you in perfect condition. In the unlikely event that your device develops a fault, please contact our service department at the address shown on this guarantee card. Of course, if you would prefer to call us then we are also happy to off er our assistance under the service number printed below. Please note the following terms under which guarantee claims can be made:
1. These guarantee terms cover additional guarantee rights and do not aff ect your statutory warranty rights. We do not charge you for this guarantee.
2. Our guarantee only covers problems caused by material or manufacturing defects, and it is restric­ted to the rectifi cation of these defects or replacement of the device. Please note that our devices have not been designed for use in commercial, trade or industrial applications. Consequently, the guarantee is invalidated if the equipment is used in commercial, trade or industrial applications or for other equivalent activities. The following are also excluded from our guarantee: compensation for transport damage, damage caused by failure to comply with the installation/assembly instructions or damage caused by unprofessional installation, failure to comply with the operating instructions (e.g. connection to the wrong mains voltage or current type), misuse or inappropriate use (such as overloading of the device or use of non-approved tools or accessories), failure to comply with the maintenance and safety regulations, ingress of foreign bodies into the device (e.g. sand, stones or dust), eff ects of force or external infl uences (e.g. damage caused by the device being dropped) and normal wear resulting from proper operation of the device. This applies in particular to rechargeable batteries for which we nevertheless issue a guarantee period of 12 months. The guarantee is rende­red null and void if any attempt is made to tamper with the device.
3. The guarantee is valid for a period of 2 years starting from the purchase date of the device. Guaran­tee claims should be submitted before the end of the guarantee period within two weeks of the de­fect being noticed. No guarantee claims will be accepted after the end of the guarantee period. The original guarantee period remains applicable to the device even if repairs are carried out or parts are replaced. In such cases, the work performed or parts fi tted will not result in an extension of the gua- rantee period, and no new guarantee will become active for the work performed or parts fi tted. This also applies when an on-site service is used.
4. In order to assert your guarantee claim, please send your defective device postage-free to the address shown below. Please enclose either the original or a copy of your sales receipt or ano­ther dated proof of purchase. Please keep your sales receipt in a safe place, as it is your proof of purchase. It would help us if you could describe the nature of the problem in as much detail as pos­sible. If the defect is covered by our guarantee then your device will either be repaired immediately and returned to you, or we will send you a new device.
Of course, we are also happy off er a chargeable repair service for any defects which are not covered by the scope of this guarantee or for units which are no longer covered. To take advantage of this service, please send the device to our service address.
Also refer to the restrictions of this warranty concerning wear parts/consumables and missing parts as set forth in the warranty conditions in these operating instructions.
- 25 -
Anl_TE_AC_270_24_10_SPK1.indb 25Anl_TE_AC_270_24_10_SPK1.indb 25 19.09.13 18:2319.09.13 18:23
F
Avertissement - Lisez ce mode d’emploi pour diminuer le risque de blessures
Portez une protection de l’ouïe. L’exposition au bruit peut entraîner une perte de l’ouïe.
Attention à la tension électrique !
Attention aux pièces brûlantes !
Avertissement ! L’unité est télécommandée et peut démarrer sans avertissement préalable.
Attention ! Avant la première mise en service, véri ez le niveau d‘huile et remplacez le bouchon d‘huile
!
Interdit ! N‘exploitez pas l‘appareil alors que les portes ou le carter sont ouverts.
- 26 -
Anl_TE_AC_270_24_10_SPK1.indb 26Anl_TE_AC_270_24_10_SPK1.indb 26 19.09.13 18:2319.09.13 18:23
F
 Attention !
Lors de l’utilisation d’appareils, il faut respecter certaines mesures de sécurité afi n d’éviter des blessures et dommages. Veuillez donc lire atten­tivement ce mode d’emploi/ces consignes de sécurité. Veillez à le conserver en bon état pour pouvoir accéder aux informations à tout moment. Si l’appareil doit être remis à d’autres personnes, veillez à leur remettre aussi ce mode d’emploi/ ces consignes de sécurité. Nous déclinons toute responsabilité pour les accidents et dommages dus au non-respect de ce mode d’emploi et des consignes de sécurité.
1. Consignes de sécurité
Vous trouverez les consignes de sécurité corres­pondantes dans le cahier en annexe.
Avertissement !
Veuillez lire toutes les consignes de sécurité et instructions. Tout non-respect des consignes
de sécurité et instructions peut provoquer une décharge électrique, un incendie et/ou des bles­sures graves.
Conservez toutes les consignes de sécurité et instructions pour une consultation ultéri­eure.
Cet appareil ne convient pas aux personnes (y compris les enfants) qui en raison de leurs capa­cités physiques, sensorielles ou intellectuelles ou leur manque d’expérience et/ou de connaissan­ces ne peuvent pas l’utiliser de manière sûre, à moins d’être surveillées et de recevoir les instruc­tions relatives à l’utilisation de l’appareil par une personne responsable de leur sécurité. Surveillez les enfants pour vous assurer qu’ils ne jouent pas avec l’appareil.
2. Description de l’appareil et volume de livraison
2.1 Description de l’appareil (fi gure 1-4)
1. Filtre à air d‘aspiration
2. Récipient sous pression
3. Roue
4. Pied d‘appui
5. Accouplement rapide (air comprimé réglé)
6. Manomètre (la pression réglée est lisible)
7. Manostat régulateur
8. Interrupteur marche/arrêt
9. Poignée de transport
10. Soupape de sécurité
11. Bouchon fi leté de vidange pour eau de con-
densation
12. Manomètre (pression du réservoir lisible)
13. Accouplement rapide (air comprimé non ré-
glé)
14. Bouchon d‘huile
15. Bouchon fi leté de vidange d‘huile
16. Interrupteur de surcharge
17. Verre-regard
18. Enjoliveur
19. Vis (à six pans creux) pour montage de la
poignée
20. Clé (à six pans)
21. Vis
22. Rondelle
23. Écrou
24. Vis de l‘axe
25. Rondelle élastique
26. Écrou
27. Ouverture de remplissage d‘huile
2.2 Volume de livraison
Veuillez contrôler si l‘article est complet à l‘aide de la description du volume de livraison. S‘il manque des pièces, il faut vous adresser dans un délai de 5 jours ouvrables maximum après votre achat à notre service après-vente ou au magasin de bricolage compétent le plus proche muni d‘une preuve d‘achat valable. Veuillez consulter pour cela le tableau des garanties dans les condi­tions de garantie à la fi n du mode d‘emploi.
Ouvrez l’emballage et prenez l’appareil en le
sortant avec précaution de l’emballage. Retirez le matériel d’emballage tout comme
les sécurités d’emballage et de transport (s’il y en a). Vérifiez si la livraison est bien complète.
Contrôlez si l’appareil et ses accessoires ne
sont pas endommagés par le transport.
- 27 -
Anl_TE_AC_270_24_10_SPK1.indb 27Anl_TE_AC_270_24_10_SPK1.indb 27 19.09.13 18:2319.09.13 18:23
Conservez l’emballage autant que possible
jusqu’à la fin de la période de garantie.
Attention ! L’appareil et le matériel d’emballage ne sont pas des jouets ! Il est interdit de laisser des enfants jouer avec des sacs et des fi lms en plastique et avec des pièces de petite taille. Ils risquent de les avaler et de s’étouff er !
Filtre à air d‘aspiration
Roue (2x)
Pied d‘appui
Poignée de transport
Bouchon d‘huile
Enjoliveur (2x)
Vis (à six pans creux) pour montage de la
poignée (4x) Clé (à six pans)
Vis
Rondelle (6x)
Écrou, pour montage du pied d‘appui
Vis de l‘axe (2x)
Rondelle élastique (2x)
Écrou, pour montage de l‘axe (2x)
Mode d‘emploi d‘origine
Consignes de sécurité
3. Utilisation conforme à l’aff ectation
Le compresseur sert à produire de l’air comprimé pour les outils fonctionnant à l’air comprimé.
La machine doit exclusivement être employée conformément à son aff ectation. Chaque uti- lisation allant au-delà de cette aff ectation est considérée comme non conforme. Pour les dommages en résultant ou les blessures de tout genre, le producteur décline toute responsabilité et l’opérateur/l’exploitant est responsable.
Veillez au fait que nos appareils, conformément à leur aff ectation, n’ont pas été construits, pour être utilisés dans un environnement profession­nel, industriel ou artisanal. Nous déclinons toute responsabilité si l’appareil est utilisé profession­nellement, artisanalement ou dans des sociétés industrielles, tout comme pour toute activité équivalente.
F
4. Données techniques
Raccordement réseau : ................ 230 V ~ 50 Hz
Puissance du moteur : ............................ 1800 W
Vitesse de rotation du compresseur tr/min : 2850
Pression de service en bars : ..................max. 10
Volume du récipient sous pression (en litres) : 24
Puissance d‘aspiration théorique l/min : ....... 270
Puissance de sortie (air comprimé)
à 7 bars : ........................................ 100 litres/min
Puissance de sortie (air comprimé)
à 4 bars : ........................................ 127 litres/min
Niveau de puissance acoustique L Imprécision K Niveau de pression acoustique L Imprécision K
Type de protection : ..................................... IP20
Poids de l‘appareil en kg : .................... env. 27 kg
Quantité d‘huile : ...........................env. 0,23 litres
Bruit
Les valeurs de niveau de bruit ont été détermi­nées conformément à EN ISO 2151.
....................................... 1,98 dB
WA
.......................................1,98 dB
pA
en dB : . 94
WA
en dB : ..... 72
pA
5. Avant la mise en service
Assurez-vous, avant de connecter la machine, que les données se trouvant sur la plaque de signalisation correspondent bien aux données du réseau.
Vérifiez que l’appareil n’a pas été endom-
magé pendant le transport. En cas d’avarie, informez immédiatement l’entreprise de transport qui a livré le compresseur. Il est recommandable d’installer le compres-
seur à proximité du consommateur. Evitez les tuyaux à air et les câbles
d’alimentation (câbles de rallonge) longs. Veillez à ce que l’air aspiré soit sec et sans
poussière. N’installez pas le compresseur dans un local
humide ou détrempé. Le compresseur doit être utilisé uniquement
dans des endroits adéquats (bonne ventila­tion, température ambiante +5°C - +40° C). Il ne doit y avoir dans la salle aucune pous­sière, aucun acide, aucune vapeur, aucun gaz explosif ou inflammable. Le compresseur doit être employé dans des
endroits secs. Il ne peut être utilisé dans des
- 28 -
Anl_TE_AC_270_24_10_SPK1.indb 28Anl_TE_AC_270_24_10_SPK1.indb 28 19.09.13 18:2319.09.13 18:23
F
zones où l’on travaille avec des éclaboussu­res d’eau. Avant la mise en service, contrôlez le niveau
d’huile dans la pompe du compresseur. Exploitez l‘appareil uniquement sur un sup-
port solide, et plat. Utilisez des tuyaux flexibles afin d‘éviter une
transmission de charges inadmissibles sur le système de conduites situé au niveau du rac­cordement de l‘installation de compression vers le système de conduites. Il est nécessaire d‘utiliser des purgeurs, des
pièges et des possibilités d‘écoulement pour traiter les liquides produits par le compres­seur avant la mise en marche de l‘installation de compression. Les tuyaux d‘amenée devraient être équipés
d‘un câble de sécurité (par ex. un câble en acier) en cas de pressions supérieures à 7 bars.
6. Montage et mise en service
 Attention ! Montez absolument l’appareil complètement avant de le mettre en service !
6.1. Montage des roues (3)
Les roues ci-jointes doivent être montées confor­mément à la fi gure 5.
6.2 Montage des pieds d’appui (4)
Les pieds d’appui (4) joints doivent être montés conformément à la fi gure 6.
6.3 Montage de la poignée de transport (9)
Vissez la poignée de transport (9) comme indiqué dans les fi gures 7 à 8 sur le compresseur.
6.4. Remplacement du capuchon obturateur
de l’huile (14)
Supprimez avec un tournevis le bouchon de transport de l’orifi ce de remplissage d’huile et int- roduisez le capuchon obturateur d’huile (14) joint dans l’orifi ce de remplissage d’huile (fi g. 9/11)
6.6. Branchement au réseau
Le moteur est doté d’un interrupteur de
surcharge (figure 3/pos. 16). En cas de surcharge du compresseur, l’interrupteur de surcharge se déconnecte automatique­ment afin de protéger le compresseur de la surchauffe. Si l’interrupteur de surcharge s’est déclenché, mettez le compresseur hors circuit par l’interrupteur marche/arrêt (8) et laissez refroidir le compresseur. Appuyez à présent sur l’interrupteur de surcharge (16) et remettez le compresseur en marche. Les longs câbles d’alimentation tout comme
les rallonges, tambours de câble etc. ent­raînent des chutes de tension et peuvent empêcher le démarrage du moteur. Lorsque la température descend en dessous
de +5° C, le moteur marche durement et peut ne pas démarrer.
6.7 Interrupteur marche/arrêt (8)
Le compresseur est mis en circuit en tirant le bouton (8). Pour mettre le compresseur hors circuit, il faut appuyer sur le bouton (8). (fi gure 2)
6.8 Réglage de pression : (fi gure 1,2)
Le régulateur de pression (7) permet de rég-
ler la pression sur le manomètre (6). La pression réglée peut être prise au niveau
du raccord rapide (5).
6.9 Réglage de l’interrupteur manométrique
L’interrupteur manométrique est ajusté à l’usine. Pression de mise en circuit: 8 bar Pression de mise hors circuit 10 bar
7. Remplacement de la ligne de raccordement réseau
Si la ligne de raccordement réseau de cet ap­pareil est endommagée, il faut la faire remplacer par le producteur ou son service après-vente ou par une personne de qualifi cation semblable afi n d’éviter tout risque.
6.5 Montage du fi ltre à air (1)
Retirez à l‘aide d‘un tournevis le couvercle de transport du raccordement du fi ltre à air. Vissez le ltre à air ci-joint (fi g. 10).
- 29 -
Anl_TE_AC_270_24_10_SPK1.indb 29Anl_TE_AC_270_24_10_SPK1.indb 29 19.09.13 18:2319.09.13 18:23
Loading...