Replacement Parts for “Thermostatic” Units
®
TRIAC |
INSTANT COMFORT…ENDLESS SAVINGS |
|
|
PART # EX 18 |
“Thermostatic” |
|
|
|
|
ELECTRIC INSTANTANEOUS WATER HEATER |
|
|
|
|
INSTALLATION GUIDE AND OWNERS MANUAL |
|
RELAY |
|
|
WARNING |
|
ELEMENT CARTRIDGE |
BEFORE ATTEMPTING INSTALLATION OF THIS UNIT OR MAKING ANY |
|||
|
||||
TEMP |
HEATER MODEL/ORDER REF. |
CARTRIDGE REF # |
ADJUSTMENTS TO THE UNIT, ALWAYS BE SURE CIRCUIT BREAKER IS OFF |
|
EX2412T |
EX610 |
TO PREVENT DANGER OF SERIOUS ELECTRIC SHOCK. |
||
ADJ |
||||
FAILURE TO GROUND THE SYSTEM MAY RESULT IN SERIOUS INJURY OR DEATH |
||||
KNOB |
EX3012T |
EX480 |
||
|
EX3512T |
EX410 |
|
|
|
EX 55T |
EX 1050 |
|
|
GROUND |
EX 65T |
EX 890 |
INSTALLER/ CONSUMER RESPONSIBILITIES |
|
EX 75T |
EX 770 |
|
||
WIRE |
EX 95T |
EX 630 |
READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL OR |
|
EX 8208T |
EX 520 |
|||
|
OPERATE THIS WATER HEATER. IF THE SAFETY RULES ARE NOT FOLLOWED, |
|||
|
EX 60T |
EX 1280 |
||
|
EX 80T |
EX 960 |
THE UNIT WILL NOT OPERATE PROPERLY AND IT COULD CAUSE DEATH, |
|
|
EX 90T |
EX 850 |
SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE. |
|
|
EX 100T |
EX 760 |
WARRANTY OF THIS WATERHEATER WILL DEPEND |
|
|
|
|
ON PROPER INSTALLATION AND OPERATION. THE WARRANTY |
|
|
CONTROL BOARD |
|
WILL BE VOID IF THE DESIGN HAS BEEN ALTERED IN ANY WAY |
|
COMPRESSION |
|
WHATSOEVER. THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE |
||
EX100/240 for 240v, 208v |
|
|||
|
FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION |
|||
SLEEVE |
EX100/277 for 277V |
|
||
PART # EX16 |
|
AND OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING PAGES. |
||
|
|
|
|
THE INSTALLATION MUST CONFORM WITH THE INSTRUCTIONS IN THIS |
|
|
MANUAL AND LOCAL CODES, OR INTHE ABSENCE OF |
|
|
LOCAL CODES, WITH THE LATEST EDITION OF THE |
|
|
NATIONAL ELECTRICAL CODE. THIS PUBLICATION IS AVAILABLE FROM |
COMPRESSION |
|
YOUR LOCAL GOVERNMENT, ELECTRIC CO., PUBLIC LIBRARY, OR BY |
|
WRITING UNDERWRITERS LABORATORIES, 333 PFINGSTEN RD., |
|
NUT |
|
|
|
NORTHBROOK, IL. 60062 |
|
PART# EX17 |
|
|
|
|
|
IF YOU REQUIRE HELP OR HAVE ANY QUESTIONS RELATING TO THE
INSTALLATION OR PERFORMANCE OF THIS HEATER, PLEASE CALL
OUR TECHNICAL SERVICE DEPARTMENT TOLL FREE:1-800-543-6163.
HAVE THE INFORMATION LISTED BELOW BEFORE CALLING:
MODEL NO.___________SERIAL NO.___________INSTALLATION DATE_____
Eemax Inc., 353 Christian St. Oxford, CT. 06478
TEL:1-800-543-6163, 203-267-7890, FAX: 203-267-7975, e-mail: eemaxinc@aol.com
GENERAL
The Eemax “Thermostatic” heater is specifically designed
to take in cold or preheated water and heat it to temperatures suitable for the normal domestic usage up to a maximum of 1400 F. To obtain optimum performance and energy savings, the unit should be located as close as possible to the point of use. The unit is supplied with compression rings and nuts suitable for direct coupling to 1/2” copper or plastic piping. Do not use additional screwed fittings or pipe dope. Doing so will void the warranty. DO NOT SOLDER PIPES WHILE THE UNIT IS INSTALLED (serious damage to the electronic flow switch will result).
This heater must have its own independent circuit, using a correctly rated breaker and
wires suitable for at least 75 oC operation.
Failure to ground this system may result in death or serious injury.
1)MOUNTING THE UNIT
1)The unit should be mounted as close to the point of use as possible.
2)This unit must only be mounted in the vertical position with the water fittings at the bottom of the unit. Mounting other than in the vertical position WILL cause element burn out.
3)The cold water inlet is on the right hand side and the hot water outlet is on the left hand side. Under NO circumstances can these be reversed.
4)Leave a minimum of 8” above the unit for easy replacement of the element.
5)The heater should be fixed to the wall using the four mounting holes at each corner of the backplate.
NOTE: The heater should be installed below the level of all hot water outlets serviced by this heater.
NOTE: PRESSURE RELIEF DEVICE
This unit is not required by UL to have a Pressure and Temperature safety relief valve (PTRV). You should check with local codes to find out if one is required in your area.
If local codes require the use of temperature and pressure relief valve it should be installed on the outlet hot water pipe before the outlet ball valve.
TROUBLE SHOOTING
SYMPTOM: NO HEAT INDICATOR LIGHT OFF
1)ELECTRIC SUPPLY IS OFF Turn on the main breaker.
2)Check the ECO (red re-set button) if tripped please call tech support
3)NO OR LOW WATER FLOW
Ensure that the minimum flow rate to switch on your heater is met. “EX100T, 95T, 90T, 8208T” Models minimum flow rate = 0.75 gpm “EX80T, 75T, 65T” Models minimum flow rate = 0.6 gpm “EX60T, 55T” 2412T,3012T, 3512T Models
minimum flow rate = 0.5 gpm
Also check that the inlet filter screen is clear from any debris. This is located in the brass inlet boss.
4) WATER CONNECTIONS ARE REVERSED
Cold water inlet = right side, hot water outlet = left side.
5) ELEMENT BURNED OUT TURN OFF THE breaker!
Using an ohmmeter test the resistance of the heating element across the two threaded termination rods on top of the element. The resistance reading should be under 10 ohms.
If the resistance is much greater than this value, call Eemax for a replacement element.
SYMPTOM: NO HEAT OR LOW TEMPERATURE WITH INDICATOR LIGHT ON
1) WATER FLOW TOO HIGH
Reduce the water flow by using an outlet ball valve. See page 3 for temperature rise at various flow rates.
2) INCORRECT POWER SUPPLY
Make sure that the unit is connected to the voltage supply specified on the rating label on the the front cover of the unit and no other.
3) ELEMENT BURNED OUT TURN OFF THE breaker!
Repeat the steps from paragraph 4 above.