Translation of the original operating instructions
W4D710-GF01-01
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 D-74673 Mulfingen
Phone +49 (0) 7938 81-0
Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com
CONTENTS
1.SAFETY REGULATIONS AND NOTES
1.1 Levels of hazard warnings
1.2 Staff qualification
1.3 Basic safety rules
1.4 Electrical voltage
1.5 Safety and protective functions
1.6 Mechanical movement
1.7 Emission
1.8 Hot surface
1.9 Transport
1.10 Storage
1.11 Disposal
2.PROPER USE
3.TECHNICAL DATA
3.1Product drawing
3.2Nominal data
3.3Data according to ErP directive
3.4Technical features
3.5Mounting data
3.6Transport and storage conditions
4.CONNECTION AND START-UP
4.1 Connecting the mechanical system
4.2 Connecting the electrical system
4.3 Connection in terminal box
4.4 Connection screen
4.5 Open additional screwed cable glands
4.6 Checking the connections
4.7 Switch on device
4.8 Switching off the device
5.MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES
5.1Cleaning
5.2Safety test
Operating instructions
1. SAFETY REGULATIONS AND NOTES
Please read these operating instructions carefully before starting to work with the device. Observe the following warnings to prevent malfunctions or physical damage to both property and people.
These operating instructions are to be regarded as part of this device. If the device is sold or transferred, the operating instructions must accompany it.
These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention.
1 |
1.1 Levels of hazard warnings |
|
1 |
||
These operating instructions use the following hazard levels to indicate |
||
1 |
||
potentially hazardous situations and important safety regulations: |
||
|
||
1 |
DANGER |
|
1 |
||
Indicates an imminently hazardous situation which, if not |
||
2 |
avoided, will result in death or serious injury. Compliance with |
|
2 |
the measures is mandatory. |
|
|
||
2 |
WARNING |
|
Indicates a potentially hazardous situation which, if not avoided, |
||
2 |
||
could result in death or serious injury. Exercise extreme |
||
2 |
||
caution while working. |
||
2 |
CAUTION |
|
|
||
2 |
Indicates a potentially hazardous situation which, if not avoided, |
|
3 |
may result in minor or moderate injury or damage of property. |
|
NOTE |
||
4 |
||
A potentially harmful situation can occur and, if not avoided, can |
||
4 |
lead to property damage. |
|
5 |
1.2 Staff qualification |
|
|
||
5 |
The device may only be transported, unpacked, installed, operated, |
|
5 |
||
maintained and otherwise used by qualified, trained and authorised |
||
5 |
technical staff. |
5Only authorised specialists are permitted to install the device, to carry out a test run and to perform work on the electrical installation.
6
1.3 Basic safety rules
6
6Any safety hazards stemming from the device must be re-evaluated once it is installed in the end device.
7Observe the following when working on the unit:
8; Do not make any modifications, additions or conversions to the
9device without the approval of ebm-papst.
9 |
1.4 Electrical voltage |
|
9 |
||
; Check the electrical equipment of the device at regular intervals, refer |
||
9 |
||
to chapter 5.2 Safety test. |
||
|
||
10 |
; Replace loose connections and defective cables immediately. |
|
10 |
DANGER |
|
Electrical load on the device |
||
10 |
Risk of electric shock |
|
|
→ Stand on a rubber mat if you are working on an electrically |
|
|
charged device. |
WARNING
Terminals and connections have voltage even with a unit that is shut off
Electric shock
→Wait five minutes after disconnecting the voltage at all poles before opening the device.
Item no. 10935-5-9970 · Revision 82513 · Release 2014-06-10 · Page 1 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
W4D710-GF01-01 |
Operating instructions |
|
|
|
|
Translation of the original operating instructions
CAUTION
In the event of failure, there is electric voltage at the rotor and impeller
The rotor and impeller are base insulated.
→ Do not touch the rotor and impeller once they are installed.
CAUTION
The motor restarts automatically when operating voltage is applied, e.g. after a power failure.
Danger of injury
→Keep out of the danger zone of the device.
→When working on the device, switch off the mains
supply voltage and secure the latter from being switched on again.
→Wait until the device stops.
→Insert the brought-out thermal overload protector into the control circuit so that the cooled off motor does not switch on independently after a fault.
1.5Safety and protective functions
DANGER
Missing safety device and non-functioning safety device
If there is no safety device, you could be seriously injured, for example if you reach into the running device or your hands are sucked into it.
→Operate the device only with a fixed and isolating safety protection and a fixed guard grille.
The guard must withstand the kinetic energy of a fan blade detaching at maximum speed.
→The device is a built-in component. You, the owner/
operator, are responsible for providing adequate protection for the device.
→Shut down the device immediately if you detect a missing or ineffective protective feature.
1.6Mechanical movement
DANGER Rotating device
Body parts that come into contact with the rotor and impeller can be injured.
→Secure the device against accidental contact.
→Before working on the system/machine, wait until all parts have come to a standstill.
WARNING Rotating device
Long hair, loose items of clothing and jewellery could become entangled and pulled into the device. You could be injured.
→Do not wear any loose clothing or jewellery while working on rotating parts.
→Protect long hair by wearing a cap.
1.7 Emission
WARNING
Depending on the installation and operating conditions, a sound pressure level greater than 70 dB(A) may arise.
Danger of noise-induced hearing loss
→Take appropriate technical safety measures.
→Protect operating personnel with appropriate safety equipment, e.g. hearing protection.
→Also observe the requirements of local agencies.
1.8Hot surface
CAUTION
High temperature at the motor housing
Danger of burn injuries
→Ensure that sufficient protection against accidental contact is provided.
1.9Transport
NOTE
Transport of device
→Transport the device in its original packaging only.
→Secure the device so that it does not slip, e.g. by using a clamping strap.
1.10Storage
;Store the device, partially or fully assembled, in a dry and weatherproof manner in the original packing in a clean environment.
;Protect the device from environmental impacts and dirt until the final installation.
;We recommend storing the device for a maximum up to one year to guarantee proper operation and longest possible service life.
;Even devices explicitly suited for outdoor use are to be stored as described prior to being commissioned.
;Maintain the storage temperature, see chapter 3.6 Transport and storage conditions.
;Please make sure that all screwed cable glands are fitted with dummy plugs.
1.11 Disposal
When disposing of the device, please comply with all relevant requirements and regulations applicable in your country.
Item no. 10935-5-9970 · Revision 82513 · Release 2014-06-10 · Page 2 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Translation of the original operating instructions
W4D710-GF01-01 |
Operating instructions |
|
|
|
|
2. PROPER USE
The device is exclusively designed as a built-in device for moving air according to its technical data.
Any other or secondary use is deemed improper and constitutes a misuse of the device.
Installations on the customer's side must meet the mechanical, thermal and service life-related stresses that can occur.
Proper use also includes:
●Use the device in power systems with earthed neutral (TN/TT power systems) only.
●Only using the device in stationary systems.
●Carrying out all maintenance.
●Moving air with a density of 1.2 kg/m³.
●Using the device in accordance with the permitted ambient temperature, see chapter 3.6 Transport and storage conditions and chapter 3.2 Nominal data.
●Operating the device with all protective features in place.
●Minding the operating instructions.
Improper use
Using the device in the following ways is particularly prohibited and may cause hazards:
●Operating the device with an imbalance, e.g. caused by dirt deposits or icing.
●Operation in medical equipment with a life-sustaining or lifesaving function.
●Operation with external vibrations.
●Moving solids content in flow medium.
●Painting the device
●Connections (e.g. screws) coming loose during operation.
●Opening the terminal box during operation.
●Moving air that contains abrasive particles.
●Moving highly corrosive air, e.g. salt spray mist. Exceptions are devices that are intended for salt spray mist and protected accordingly.
●Moving air that contains dust pollution, e.g. suctioning off saw dust.
●Operating the device close to flammable materials or components.
●Operating the device in an explosive atmosphere.
●Using the device as a safety component or for taking on safetyrelated functions.
●Operation with completely or partially disassembled or modified protective features.
●In addition, all application options that are not listed under proper use.
Item no. 10935-5-9970 · Revision 82513 · Release 2014-06-10 · Page 3 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com