Modular Production Center
RBD-60-TC4
RBD-60-CP4
Installation and
Operation Manual
RBD-60CP4
CAUTION:
RBD-60TC4
Please read this manual completely before attempting
to install, operate or service this equipment
This manual is Copyright © 2018 Duke Manufacturing Co. All rights reserved.
Reproduction without written permission is prohibited. Duke is a registered
trademark of the Duke Manufacturing Co.
P/N 529120
REV A Date 08/01/2018
Installation and Operation of: Kool System
TABLE OF CONTENTS
Important Safety Instructions ............................................................................................................................ 2
Critical Daily Startup Guide ................................................................................................................................ 4
Specications ........................................................................................................................................................... 6
Installation ................................................................................................................................................................ 7
Operation .................................................................................................................................................................. 8
Cleaning and Maintenance ................................................................................................................................. 9
Wire Diagram .........................................................................................................................................................10
IMPORTANT SAFETY INSTRUCTIONS
Throughout this manual, you will nd the following safety words and symbols that signify
important safety issues with regards to operating or maintaining the equipment.
Indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
Indicates electrical shock hazard which, if not avoided, could
Indicates hot surface which, if not avoided, could result in
Indicates Important Information
result in death or serious injury and/or equipment damage.
minor or moderate injury.
2
Installation and Operation of: Kool System
In addition to the warnings and cautions in this manual, use the following guidelines for
safe operation of the unit.
• Read all instructions before using equipment.
• For your safety, the equipment is furnished with a properly grounded cord connector. Do
not attempt to remove or disconnect the grounded connector.
• Install or locate the equipment only for its intended use as described in this manual.
• Do not use corrosive chemicals on this equipment.
• Do not operate this equipment if it has a damaged cord or plug, if it is not working
properly, or if it has been damaged or dropped.
• This equipment should be serviced by qualied personnel only. Contact the nearest
Duke authorized service facility for adjustment or repair.
• Do not block or cover any openings on the unit.
• Do not immerse cord or plug in water.
• Keep cord away from heated surfaces.
• Do not allow cord to hang over edge of table or counter.
The following warnings and cautions appear throughout this manual and should be
carefully observed.
• Turn the unit o, disconnect the power source and allow unit to cool down before
performing any service or maintenance on the unit.
• The procedures in this manual may include the use of chemical products. You must read
the Material Safety Data Sheets before using any of these products.
• The unit should be grounded according to local electrical codes to prevent the
possibility of electrical shock. It requires a grounded receptacle with dedicated electrical
lines, protected by fuses or circuit breaker of the proper rating, in accordance with all
applicable regulations.
• Disposal of the unit must be in accordance with local environmental codes and/or any
other applicable codes.
• This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
3
Installation and Operation of: Kool System
INSTALLATION
This equipment is to be installed to comply with applicable
Federal, State or Local Plumbing Code.
DRAIN CONNECTION:
The unit is designed to be used with or without a drain hook-up. The drain is supplied with
a hose attached for use with a bucket, or may be hooked up to a oor or sink drain. Consult
local codes as to the type of drain hook-up required in your area.
The Refrigerated Counter Top is designed to hold pre-chilled products at suitable serving
temperature. It is not designed to chill products or store them for long periods of time.
Due to the variety of food products served from the efrigerated counter top, they should
be stirred periodically to maintain consistent temperature. Foods that are not stirred
periodically can become too warm on the top surface and freeze at the bottom. Prior to use,
the unit should be turned on to lower the pan temperature before the chilled product is set
in place. The unit should shut down daily for defrosting and cleaning.
ELECTRICAL CONNECTIONS:
The unit is designed to be operated on one (1) 15 amp dedicated circuit. The unit must be
grounded. The receptacle, wired circuit, and protection should meet the required local codes
for proper operation. If the supply cord is damaged, it must be replaced by the manufacturer,
it’s service agent or an authorized service company in order to avoid a hazard.
4