Duke ADI-2MSL-N7 Service Manual

“ADI” TYPE ICE PANS
MECHANICALLY ASSISTED ICE PANS
STANDARD 7 COLD PANS
Installation and
Operation Manual
Please read this manual completely before attempting
to install, operate or service this equipment
This manual is Copyright © 2018 Duke Manufacturing Co. All rights reserved.
Reproduction without written permission is prohibited. Duke is a registered
trademark of the Duke Manufacturing Co.
Duke Manufacturing Co.
St. Louis, MO 63102
Phone: 314-231-1130
Toll Free: 1-800-735-3853
Fax: 314-231-5074
www.dukemfg.com
P/N 219565
REV K 1/15/2018
Installation and Operation of: Thurmaduke Ice Pans
WARNING
CAUTION
CAUTION
TABLE OF CONTENTS
Manufacturer’s Introduction ................................................................................................................... 2
Important Safety Instructions .............................................................................................................. 2-3
Installation ............................................................................................................................................. 4
Installation -Drop In Refrigerated........................................................................................................... 5
Installation - Cold Pan ........................................................................................................................... 6
Mechanically Assisted Ice Pan - Adjusting Thermostatic Controls ........................................................ 7
Standard 7 Cold Pans - Adjusting Thermostatic Controls ..................................................................... 8
Wire Diagrams ......................................................................................................................................11
MANUFACTURER’S INTRODUCTION
THE DUKE COLD PAN IS A SERVING UNIT SPECIALLY DESIGNED FOR HOLDING AND SERVING FOODS AND CONDIMENTS. IT SHOULD NOT BE USED FOR CHILLING PRODUCTS; IT IS ONLY FOR HOLDING AND SERVING FOODS AND CONDIMENTS.
IMPORTANT SAFETY INSTRUCTIONS
Throughout this manual, you will nd the following safety words and symbols that signify important
safety issues with regards to operating or maintaining the equipment.
Indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
Indicates electrical shock hazard which, if not avoided, could result
2
Indicates Important Information
in death or serious injury and/or equipment damage.
Installation and Operation of: Thurmaduke Ice Pans
In addition to the warnings and cautions in this manual, use the following guidelines for safe operation of the unit.
Read all instructions before using equipment.
For your safety, the equipment is furnished with a properly grounded cord connector.
Do not attempt to remove or disconnect the grounded connector.
Install or locate the equipment only for its intended use as described in this manual.
Do not use corrosive chemicals in this equipment.
Do not operate this equipment if it has a damaged cord or plug, if it is not working properly, or if it
has been damaged or dropped.
Do not store explosive substances such as aerosol cans with a ammable propellant inside the appliance.
This equipment should be serviced by qualied personnel only. Contact the nearest Duke authorized service facility for adjustment or repair.
Do not block or cover any openings on the unit.
Do not immerse cord or plug in water.
Keep cord away from heated surfaces.
Do not allow cord to hang over edge of table or counter.
The following warnings and cautions appear throughout this manual and should be carefully observed.
Turn the unit off, disconnect the power source before performing any service or maintenance on the unit.
The procedures in this manual may include the use of chemical products. You must read the
Material Safety Data Sheets before using any of these products.
The unit should be grounded according to local electrical codes to prevent the possibility of electrical shock.
It requires a grounded receptacle with dedicated electrical lines, protected by fuses or circuit
breaker of the proper rating, in accordance with all applicable regulations.
Disposal of the unit must be in accordance with local environmental codes and/or any other applicable codes.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their
safety.
Children should be supervised to ensure that they do not play with the appliance
3
Installation and Operation of: Thurmaduke Ice Pans
CAUTION
WARNING
CAUTION
INSTALLATION
WHEN MOUNTING FROM BELOW THE COUNTER TOP:
The top surface of the unit should have applied to it a generous bead of a silicone rubber sealant such as Dow Corning “RTV” or G.E. Silicone sealant. After clamping the unit up against the counter top, wipe from the joint any excess sealant which squeezes out. The unit mount­ed in this manner should be supported from below by an appropriate metal structure or hung from the underside of the top by mounting angels of at least 18 gauge steel.
WHEN MOUNTING BY THE OVERHANGING TOP RIM (IN A CUT-OUT IN THE COUNTER TOP):
The underside of the overhanging top rim should have applied to it a generous bead of sili­cone before the unit is set into the cut-out in the counter top. In order to relieve part of the load from the top rim, the unit should be supported from below with metal components in a manner compatible with the construction of the counter. Any excess sealant which squeezes out between the unit top rim and counter top should be wiped o before the sealant cures or stripped away with a sharp knife after curing.
Electricity and water do not mix. Unplug the unit before cleaning. If repairs are required, use a qualied service agent. While repairs are being made, be sure the unit is not plugged in. Do not store highly combustible substances on or near the unit. Be sure the compressor compartment has adequate ventilation.
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing this equipment.
Fluorescent Lamps contain Mercury. Dispose of in Accordance to Lo­cal Regulations.
When installing a drop-in refrigerated unit it is essential to insure proper air ow into and out of the cabinet surrounding the unit. Im­proper ventilation will cause your compressor to burn out and will void the warranty.