9.3 Stand tube ................................................................................................ Page 12
9.4 Spare parts for lamp head / arm............................................................... Page 13
9.5 Spare parts for five-foot base ................................................................... Page 13
9.6 Spare parts for stand tube........................................................................ Page 13
59010001 Edition 02 13.04.2000 / Bak Page 2/13
Makrolux
Dr. Mach
Lamps and Engineering
1. Safety instructions
Please pay attention to the directions for use when handling the lamp!
The lamp is supplied with integrated connection lead, earthed plug and a transformer
230/12V 20W integrated in the plug. The lamp is to be used only with this transformer.
The socket to be used for the lamp must be installed according to the requirements
stipulated by the IEC or VDE 0107.
Please check that the earthed socket is available within the working area of the lamp.
This device is not suitable for use in hazardous locations.
The lamp is manufactured and tested according to the standards IEC DIN 601.
The lamp is tested for electromagnetic compatibility according to the standards EN
60601-1-2 / 4. 1994.
The lamp is classified as a group 1 device according to the MPG (law for medical
products).
Repairs to the lamp and special installation work on the reflector or at the transformer
should only be carried out by ourselves or a company expressly authorised by ourselves.
The manufacturer is only responsible for the safety of the lamp if repairs and alterations have been carried out by themselves or a company who can guarantee that the
safety regulations have been observed.
The manufacturer is not liable for personal or material damages if the lamp is misappropriately or incorrectly operated or misused.
Attention: The lamp can be disconnected from mains only by pulling the plug off the
earthed socket.
All Dr. Mach stand lamps are supplied with all installation and connection parts and
components.
For packaging reasons, the five-foot stand is supplied in dismantled state. The stand
tube is always assembled as a unit and only needs to be attached to the foot with the
lower fastening screw.
59010001 Edition 02 13.04.2000 / Bak Page 3/13
Makrolux
9
14
6 7
13
2. Mounting instructions
8
2
1
3
5
17
12
4
11
16
2.1 Pre-mounting of the stand
Fix the upper part 1 of the stand tube (with ball
handle 2) to the lower part of the stand tube 3
and tighten.
2.2 Mounting the five-feet base
with the stand tube
15
For mounting the stand proceed as follows:
• Place the central base 4 onto the stand
tube ∅25 5. The stiffness is to ensure a
tight fit that is free from any movement.
• Pre-mount the cam catch plate 6 (cams
point inwards), with the lock washer 7 and
cheese head screw M8 8, so that the extension arm 9 can still fit easily into the
central base. Insert the extension arm 9
into the central base from above holding
10
the cam catch plate 6 against from the opposite side.
• Insert the other 4 extension arms 10-13 in
the sequence shown in the left figure into
the central base. The extension arms are
held by the cams of the cam catch plates.
Remark: Mount the two locking rollers 14
and 15, and the two electrically conductive
rollers 16 and 17 as shown in the figure (not
next to each other).
• Tighten the catch plate with an Allen key
SW6 (approx. 15Nm).
The cams of the catch plate must mate with
the drill holes of the extension arms so that
every extension arm is tightly fitted to both
the central base and stand tube.
The cams also prevent the extension arms
from being pulled out.
Dr. Mach
Lamps and Engineering
59010001 Edition 02 13.04.2000 / Bak Page 4/13
Makrolux
Dr. Mach
Lamps and Engineering
2.3 Mounting the lamp
21
18
19
20
• Disengage clamping lever 19 to open plas-
tic joint 18 just enough , so that it can be
put on stand 20.
• The swivel arm 21 has to be mounted n
such a way, that its position is above the
joint 18 (see figure).
• Adjust height and radius of the swivel arm
and tighten clamping lever 19, so that the
friction of the joint holds the lamp in the requested position.
2.4 Wall mounting
• Mark the position of the holes to be drilled in the wall using the wall bearing.
• Drill the holes and insert the dowels.
• Insert the wall bracket into the location hole of the wall bearing and fix it with the clamping
grub screw.
• Mount the plastic joint 18 on the wall bracket.
• To mount the lamp proceed as described at point 2.3.
2.5 Table mounting
• Screw on table clamp on the table in the desired position.
• Insert the lamp with the upper part 1 of the stand tube into the clamp hole and fix with the
clamping grub screw.
59010001 Edition 02 13.04.2000 / Bak Page 5/13
Makrolux
22
19
3. Directions for use
3.1 ON/OFF switch
Use the switch 22 at the lamp housing to turn
the lamp on and off.
21
3.2 Positioning
For height adjustment the arm 21 can either be
swivelled or adjusted in height by loosening adjusting lever 19.
The self-locking joints 23, 24 can be adjusted by
tightening the clamp screw.
Dr. Mach
Lamps and Engineering
Clamp screw
23,24
59010001 Edition 02 13.04.2000 / Bak Page 6/13
Makrolux
Alc. ≤ 20 %
25,26
4. Cleaning
4.1 Lamp head
The lamp has a high-quality surface, which can
be cleaned with conventional cleaning agents.
Only use disinfectant with less then 20% alcohol.
4.2 Protective disk
(filter disk)
The protective disk 25 is made of an high-quality
plastic, the filter disk 26 is made of high quality
glass. For cleaning use lukewarm water and a
soft viscose sponge. Pay attention to the following during cleaning:
- Wipe over the protective disk 25 (filter disk
26) with a wet cloth (never use a dry cloth!).
- Only use disinfectant with less then 20%
alcohol.
Wipe protective disk 25 (filter disk 26) after
cleaning with an antistatic, non-fluffy cloth.
Dr. Mach
Lamps and Engineering
5. Maintenance
5.1 General information
The lamp is constructed in such a way, that regular service intervals are not required.
If necessary, the clamp screws at the self-locking joints have to be tighten.
59010001 Edition 02 13.04.2000 / Bak Page 7/13
Makrolux
28
27
25,26
Dr. Mach
Lamps and Engineering
30
29
29
31
5.2 Changing of spare parts
5.2.1 Changing the halogen bulb
Dr. Mach uses special halogen bulbs as illuminants.
Only original Dr. Mach replacement bulbs may
be used.
The use of other bulbs can lead to a considerable reduction of the light power and increase in
the thermal load.
Attention! Disconnect from mains before
changing the bulb.
To change the bulb proceed as follows:
• Loosen and remove four fixing screws 27 at
the upper front ring 28.
• Lift the upper front ring 28 off the lamp hous-
ing 29.
• Push halogen bulb 12V 20W 30 backwards
and turn anticlockwise (bayonet catch).
• Replace upper front ring 28 on the lamp
housing 29 and fix it with the screws 27.
Remark:
The halogen bulbs have a service life of approx. 1000 hours without any deterioration in
their luminosity.
5.2.2 Changing the protective disk
(filter disk)
To change the protective disk (filter disk) proceed as follows:
• Loosen and remove two fixing screws 31 at
the lower front ring 28.
• Lift the lower front ring 28 off the lamp hous-
ing 29.
• Press the three retaining clamps H at the
lower front ring 28 carefully to the edge and
lift the protective disk 25 or the filter disk 26.
• Insert the new protective disk or filter disk in
reverse order.
H
59010001 Edition 02 13.04.2000 / Bak Page 8/13
28
Makrolux
Dr. Mach
Lamps and Engineering
6. Data
6.1 Technical data
6.1.1. Technical data of the lamp Makrolux
~ Wechselstrom Alternating current
Pr Primärseitig 230V / 0,35A Primary side
Sek Sekundärseitig 12V AC / 1,66A Secondary side
Hz Hertz – Frequenz 50 / 60Hz Frequency Hertz
Schutzgrad Type „B“ Class of protection
6.1.2. Technical data of the stand
Lamp type
Data
Makrolux
Number of extension arms
Stand foot
Stand tube
Swivel arm +
lamp head
Length of arm 310mm
Rollers ∅
Approx. length 95cm – 145cm
Diameter 25mm
Extension yes
Power supply no
Suitable for
article no.
• Swivel arm and lamp head
Mounting
• Swivel arm to stand
1100 1012 00
1101 1012 00
pre-mounted
5
50mm
59010001 Edition 02 13.04.2000 / Bak Page 9/13
Makrolux
Dr. Mach
Lamps and Engineering
6.2 Environmental conditions
Operation
Temperature +10°C +40°C
Relative atmospheric humidity 30% 75%
Air pressure 700 hPa 1060 hPa
Transport / storage
Temperature -10°C +50°C
Relative atmospheric humidity 20% 90%
Air pressure 700 hPa 1060 hPa
Min. Max.
Min. Max.
7. CE- mark
The products Makrolux comply to the standards 93/42/EEC for medical products
of the European Community’s Council.
8. Disposal
The components of the lamp should be properly disposed at the end of its shelf-life.
Make sure, that the materials are carefully separated.
The lamp does not contain any danger goods. The components should be disposed according
to the contained materials.
59010001 Edition 02 13.04.2000 / Bak Page 10/13
Makrolux
9.1 Lamp head, arm
22
28
9. Spare parts
Dr. Mach
Lamps and Engineering
38
37
30
27
47
39
28
46
29
31
25,26
21
40
36
42
44
23
45
24
43
59010001 Edition 02 13.04.2000 / Bak Page 11/13
Makrolux
9.2 Five-foot base
9.3 Stand tube
33
02
32
Dr. Mach
Lamps and Engineering
48
18
34
01
35
19
41
59010001 Edition 02 13.04.2000 / Bak Page 12/13
Makrolux
Dr. Mach
Lamps and Engineering
9.4 Spare parts for lamp head / arm
Item Qty. Name EDVNO Remarks
21 1 Swivel arm 01080205
22 1 ON/OFF switch 67340004
23 1 Tilt joint – upper part 01080203
24 1 Tilt joint – lower part 01080204
25 1 Protective disk 01011208
26 1 Filter disk 01011203
27 4 Sheet metal screw DIN 7982-2,2x6 65872001
28 2 Front ring 01011202
29 1 Housing 01011201
30 1 Halogen bulb (bayonet catch) 12V 20W 67100203
31 2 Sheet metal screw DIN 7982-2,2x6 65872001
36 1 Connection cable with plug transformer