Dr. Mach Mach 120, Mach 130, Mach 130F, Mach LED 120, Mach LED 120F Mounting Instructions, Directions For Use

...
Wall attachment Mach 120/130 Mach LED 120/130
Mounting instructions Directions for use
MACH LED 120/130
MACH 120/130
Dr. Mach
Lamps and Engineering
Wall lamps:
Dr. Mach
59860002 Edition 11 25.25.2011 / Bak Page 1/19
Mach 120...............................
Mach 120F.............................
Mach 130...............................
Mach 130F.............................
Mach LED 120.......................
Mach LED 120F.....................
Mach LED 130.......................
Mach LED 130F.....................
GmbH u. Co., Flossmannstrasse 28, D-85560 Ebersberg
Tel.: +49 (0)8092 2093 0, Fax +49 (0)8092 2093 50
Internet: www.dr-mach.com, E-mail: info@dr-mach.de
Order No. 120 110 2202 Order No. 120 220 2202 Order No. 130 120 2202 Order No. 130 230 2202 Order No. 120 310 2202 Order No. 120 420 2202 Order No. 130 330 2202 Order No. 130 430 2202
Wall attachment Mach 120/130 Mach LED 120/130
Dr. Mach
Lamps and Engineering
List of contents
1. Safety instructions.............................................................................................................Page 4
2. Mounting layout wall lamps...............................................................................................Page 5
3. Wall attachment.................................................................................................................Page 7
3.1 Preparatory work on the wall......................................................................................Page 7
3.2 Mounting the wall bearing..........................................................................................Page 8
3.2.1 Wall attchments, room heights...........................................................................Page 9
4. Electrical connection..........................................................................................................Page 10
4.1 Preparing the electrical connection............................................................................Page 10
4.2 Position of transformer – Dr. Mach lamps..................................................................Page 10
4.3 Wiring diagrams .........................................................................................................Page 10
5. Mounting the articulated arms and the lamp head............................................................Page 11
5.1 Mounting the articulated arms to the wall bearing .....................................................Page 11
5.2 Mounting the lamp to the spring arm..........................................................................Page 12
6. Cleaning ............................................................................................................................Page 14
7. Maintenance......................................................................................................................Page 14
7.1 Periodical maintenance work.....................................................................................Page 14
7.2 Adjusting the spring force...........................................................................................Page 15
7.3 Maintenance of the segment......................................................................................Page 15
8. Data...................................................................................................................................Page 16
8.1 Technical data............................................................................................................Page 16
8.2 Environmental conditions...........................................................................................Page 16
9. Disposal.............................................................................................................................Page 16
10. CE- mark .........................................................................................................................Page 16
11. Dimensions and range of movement...............................................................................Page 17
12. Spare parts......................................................................................................................Page 18
13. Spare parts list.................................................................................................................Page 19
59860002 Edition 11 25.25.2011 / Bak Page 2/19
Wall attachment Mach 120/130 Mach LED 120/130
Dr. Mach
Lamps and Engineering
Static inspection
Note: The static (structural) inspection must be carried out before the installation of the ceiling or wall anchorage!
- The strength of the construction must be designed, checked and certified by a structural
engineer.
- The respective regional construction regulations that apply must be followed.
- If a wrong hole is drilled by mistake, e.g. drilling of a reinforcement rod, the structural
engineer who is responsible must be contacted, since adequate static load distribution in the ceiling may have been endangered.
Declaration of acceptance:
It is hereby certified that the supporting ceiling / wall and the ceiling anchoring / wall anchoring is safe and adequately strong.
Project: ____________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
Anchoring (please check the one that is applicable)
- with dowels authorized by construction authority
- with counter-plate
- other
Location: ____________________________________________
Signature / Stamp: (structural engineer / construction authority)
59860002 Edition 11 25.25.2011 / Bak Page 3/19
Wall attachment Mach 120/130 Mach LED 120/130
Dr. Mach
Lamps and Engineering
These installation instructions must be kept at hand together with the
relevant operating instructions of the lamp for consultation at any time.
1. Safety instructions
It is not allowed to connect the lamp to the mains, until it has been fully assembled and installed. This device is not suitable for use in hazardous locations.
The devices are not suitable for use in combustible blends of anaesthesia agents with oxygen or nitrous oxide. Repairs to the wall attachment and special installation work on the sliding contacts should only be carried out by ourselves or a company expressly authorised by ourselves.
The manufacturer is only responsible for operational safety of the wall attachment when repairs and modifications are carried out by his own staff or by persons who guarantee compliance with the safety regulations.
The manufacturer is not responsible for damage to persons or property caused by incorrect or improper use, or when used for incorrect purposes.
In view of the slight weight of the Dr. Mach lamps, it is not fundamentally necessary to drill through the wall and use a counter-plate. Depending on the stability of the location, it may be necessary to use a counter-plate for the wall attachment.
The forces arising when the widely extending articulated arms tilt, do make it necessary to drill very carefully with a certified hammer drill, paying close attention to the drilling tolerances.
59860002 Edition 11 25.25.2011 / Bak Page 4/19
Wall attachment Mach 120/130 Mach LED 120/130
2. Mounting layout wall lamps
Type 1: Mach 120; Mach 120F
Wall
Bracket Spring arm
Dr. Mach
Lamps and Engineering
Wall bearing
Lamp
Type 2: Mach 130; Mach 130F
Wall
Wall bearing
Lamp
Bracket Spring arm
59860002 Edition 11 25.25.2011 / Bak Page 5/19
Wall attachment Mach 120/130 Mach LED 120/130
Wall bearing
Dr. Mach
Lamps and Engineering
Wall
Bracket
Light
Spring arm
59860002 Edition 11 25.25.2011 / Bak Page 6/19
Wall attachment Mach 120/130 Mach LED 120/130
3. Wall attachment
3.1 Preparatory work on the wall
70
190
lower fixation hole for wall bearing
Dr. Mach
Lamps and Engineering
Fastening with dowels
If dowels are included in the scope of supply, please do not use them! Dr. Mach cannot guarantee that the supplied dowels are suitable with the existent wall. Please ask a structural engineer for the proper dowels according to the configuration of the wall (see also the static inspection on page 5).
In the case of a fixed connection, lay the electrical cable.
Fastening with counter-plate
Depending on the stability of the location, it may be necessary to use a counter-plate for the wall attachment.
Ascertain the exact position of the OT-lamp-
In the case of a fixed connection, lay the
electrical cable.
Stick the supplied drilling template to the wall.
Drill the two holes 12mm and 190mm apart.
When drilling, keep as closely as possible to the spacing between the holes. The counter-plate can be mounted with variations of up to 20mm.
Electrical connection is carried out later using a 2m long cable provided by Dr. Mach with shock-proof plug on the wall arm.
It is important to check whether there is an appropriate plug socket in the vicinity.
If the lamp is to be connected directly, the mains connection must be located between the two fixing screws (see section showing electrical connection).
Follow any directions given by the technical staff!
59860002 Edition 11 25.25.2011 / Bak Page 7/19
Wall attachment Mach 120/130 Mach LED 120/130
4.2 Mounting the wall bearing
Dr. Mach
Lamps and Engineering
For mounting the wall bearing proceed as follows:
3
2
1
Fastening with dowels
Fix the wall bearing with the dowels recommended by the structural engineer.
Place cover 1, cover 2 and cap 3 in position in such a way that they engage in the locks.
Fastening with counter-plate
Fix the wall bearing, push through the M10 threaded rods and screw on the wall bracket and counter-plate using bolts and hexagonal nuts (if necessary, weld the hexagonal nuts to the counter-plate).
Place cover 1, cover 2 and cap 3 in position in such a way that they engage in the locks.
59860002 Edition 11 25.25.2011 / Bak Page 8/19
Wall attachment Mach 120/130
g
g
Mach LED 120/130
4.2.1 Wall attachment, room heights
90 800
Dr. Mach
Lamps and Engineering
Wall attachment
R700
985
ht=2000 hei
Passin
Lower fixation hole for wall bearing
Room heights H wall attachments
Lower borehole for
Lamps
Mach 120 2274 Mach 120F 2274 Mach 130 2274 Mach 130F 2274 Mach LED 120 2274 Mach LED 120F 2274 Mach LED 130 2274 Mach LED 130F 2274
wall bearing
(min)
59860002 Edition 11 25.25.2011 / Bak Page 9/19
Wall attachment Mach 120/130 Mach LED 120/130
Dr. Mach
Lamps and Engineering
4. Electrical connection
4.1 Preparing the electrical connection
Wall attachment
The lights Mach 130 and Mach 130F are normally supplied with integrated transformer and connection cable with shock-proof plug. The socket used must be installed according to IEC or VDE 0100-710 requirements. In case of the lights Mach LED 120, Mach LED 120F, Mach 120 and Mach 120F the transformer is positioned in the wall bearing.
Once the electrical connections have been completed, check that the system functions correctly in a no­load operation trial run. When connecting to an external transformer, the emerging voltage U will be approx. 10-20% above rated voltage because of no load and anticipated lead losses. There is no point in making any adjustments until the lamps have been completely mounted.
4.2 Position of transformer – Dr. Mach lamps
Lamps External transformer
Transformer
in the lamp housing
Remark
Mach 120 / 120F X*
Mach 130 / 130F X X*
Mach LED 120 / 120F X* Mach LED 130 / 130F X*
* Transformer included in the extent of supply
5.3 Wall lights with external transformer / power supply
a. Lights Mach LED 120 / 120F and Mach 120 / 120F
Transformer or power supply
Wall bearing
Bracket
In case of the lights Mach LED 120, Mach LED 120F, Mach 120 and Mach 120F the transformer is positioned in the wall bearing.
It is possible to connect these lamps direct to a power supply cable through the wall. Optionally the lights can be connected by the supplied connection cables with shock-proof plug to the wall socket.
For models with electronic transformer – potentiometer instead of change-over switch
59860002 Edition 11 25.25.2011 / Bak Page 10/19
Wall attachment Mach 120/130 Mach LED 120/130
5. Mounting the articulated arms and the l head
5.1 Mounting the articulated arms to the wall bearing
1 2 5 4
Wall bearing
Articulated arm
Dr. Mach
Lamps and Engineering
To mount the articulated arms proceed as follows:
Loosen the screw 1.
Remove cover 2 including the sliding contact-
plug.
Remove circlip 3, gib washer 4 and levelling washer 5 from the suspension tube (tool: mounting plier).
Slide the articulated arm onto the suspension tube.
Slide the levelling washer, gib washer and circlip onto the suspension tube in the correct order.
Take care to ensure that the nose of the gib washer lies on the lateral bore (not shown) of the suspension tube, and that the safety ring slots properly into the groove of the suspension pipe (tool: mounting plier).
Place the cover 2 back on the articulated arm and screw on with screw 1.
3
59860002 Edition 11 25.25.2011 / Bak Page 11/19
Wall attachment Mach 120/130 Mach LED 120/130
Dr. Mach
Lamps and Engineering
5.2 Mounting the lamp to the spring arm

ATTENTION! Notice the rated voltage information!

Coupling journal
Lamp bow
Sticker with voltage information
Each lamp has a red sticker applied near the coupling journal at the lamp bow. The sticker shows the rated voltage of the lamp. Connect the lamp only to the prescribed voltage, to avoid irreparable damage (e.g. the electrical components).
Following rated voltage is usual:
230V 24-28V DC 22,8V
After mounting the lamp take off the sticker and dispose it, otherwise it could fall down in the OT­field after some time!
120V
110V
59860002 Edition 11 25.25.2011 / Bak Page 12/19
Wall attachment Mach 120/130 Mach LED 120/130
Do not remove screw 13, it is designed to fix the sliding contact and provides earthling!
13
3 3
2
180°
5
13
8
10 12 11 9
3 6 4
8 8 7
180°
Dr. Mach
Lamps and Engineering
Attention: If the spring arm is pushed downwards (the arm is under spring tension) it may bounce up and cause harm. While mounting the lamp head no other persons are allowed to be within the swivel range of the spring arm.

Mounting the lamp Mach 120/120F to the spring arm

Loosen brake screw 1, so the plastic bushing 2 can be slipped easy onto the spring arm.
Slip plastic bushing 2 onto the spring arm to
1
12
overlap slots 3.
Check if the journal 4 of the lamp is greased.
Insert the greased journal 4 of the lamp and
insert security segment 5 completely into slot 3, so that the security segment leads in groove 6.
Rotate plastic bushing 2 by 180° up to the provided drilling for the brake screw and
screw in brake screw 1 until you reach the desired brake effect for lamp head 4.
Check if lamp head 4 is firmly fixed.
Mounting the lights Mach LED 120/120F, Mach LED 130/130F and Mach 130/130F to the spring arm
Loosen brake screw 12, so the plastic bushing 7 can be slipped easy onto the spring arm.
Slip plastic bushing 7 onto the spring arm to overlap slots 8.
Check if the journal 9 of the lamp is greased.
Insert the greased journal 9 of the lamp and
insert security segment 10 completely into slot 8, that the security segment leads in groove 11.
Rotate plastic bushing 7 by 180° up to the provided drilling for the brake screw and
screw in brake screw 12 until you reach the desired brake effect for lamp head 9.
Check if lamp head 9 is firmly fixed.
59860002 Edition 11 25.25.2011 / Bak Page 13/19
Wall attachment Mach 120/130 Mach LED 120/130
Dr. Mach
Lamps and Engineering
6. Cleaning
Note: Before doing any cleaning work turn off the lamp, disconnect from mains and make sure that the lamp cannot be switched on again.
Please ensure that no disinfection liquid flows into the joints or lamp head. The surface of the ceiling attachment can be easily kept clean by simply wiping with a wet cloth. You can
use conventional cleaning agents.
Caution: In order to prevent any damage at plastic parts, do not use scouring agents or alkaline, acidic and alcoholic cleaning agents.
For cleaning proceed as follows:
Draw plug from mains.
Wipe the surface of the ceiling attachment with a wet cloth. As a cleaning agent you can use water or
a soap solution (washing-up liquid).
7. Maintenance
Note: Before doing any maintenance work, turn off the lamp, disconnect from mains and make sure, that the lamp cannot be switched on again.
7.1 Periodical maintenance work
The following maintenance work/tests has/have to be done every six months:
check on defects in paint work;
check on fissures at plastic parts;
check on deformation of the suspension.
The following maintenance work/tests has/have to be done once a year:
check the function;
electrical safety test;
check the suspension.
Remark: Check and grease the security segment once a year.
59860002 Edition 11 25.25.2011 / Bak Page 14/19
Wall attachment Mach 120/130 Mach LED 120/130
Dr. Mach
Lamps and Engineering
7.2 Adjusting the spring force
Springs are wearing parts, thus the spring force can decrease in time and must be readjusted.
Note: Set the spring force in such a way, that the spring arm with the lamp head holds its position at every set height.
B
A
B
In case the spring arm with the lamp moves down on its own, proceed as follows:
Remove lateral cover A. The adjusting screw (B) for the spring force is visible now.
Push the lamp and spring arm upwards as much as possible, so the spring is without charge.
Insert a slotted screwdriver into the screw B.
Turn the adjusting screw to the left
(anticlockwise), until the lamp holds its position at every set height.
In case the spring arm with the lamp moves up on its own, proceed as follows:
Remove lateral cover A. The adjusting screw (B) for the spring force is visible now.
Push the lamp and spring arm upwards as much as possible, so the spring is without charge.
Insert a slotted screwdriver into the screw B.
Turn the adjusting screw to the right
(clockwise), until the lamp holds its position at every set height.
7.3 Maintenance of the segment
Dismount the lamp head in reverse order of mounting (see chapter 5.2).
Check the thickness of the segment. It must be at least 1,5mm. In case the thickness of the segment
is less than 1,5mm, it has to be changed.
Grease the segment and the coupling journal of the lamp.
Mount the lamp to the spring arm (see chapter 5.2).
59860002 Edition 11 25.25.2011 / Bak Page 15/19
Wall attachment Mach 120/130 Mach LED 120/130
Dr. Mach
Lamps and Engineering
8. Data
8.1 Technical data
Rated voltage 120V / 230V Rated frequency 50 / 60Hz Power consumption 60W Rated current at 24V 2,5A Protection class I.
The device is not suitable for use in combustible blends of anaesthesia agents with air or for use in combustible blends of anaesthesia agents with oxygen or nitrous oxide. The device is designed for continuous operation.
8.2 Environmental conditions

Operation

Min. Max.

Wall attachment

Temperature +10°C +40°C Relative atmospheric humidity 30% 75% Air pressure 700hPa 1060hPa

Transport / storage

Temperature +10°C +40°C Relative atmospheric humidity 30% 75% Air pressure 700hPa 1060hPa
Min. Max.
9. Disposal
The wall attachments do not contain any danger goods. The components of the wall attachment should be properly disposed at the end of its shelf life. In order to respect all regulations for disposal, please contact us before disposing the product.
10. CE- mark
The products wall attachment comply to the EMC standards 93/42/EEC for medical products of the European Community’s Council.
59860002 Edition 11 25.25.2011 / Bak Page 16/19
Wall attachment Mach 120/130 Mach LED 120/130
10. Dimensions and range of movement
90 800
Dr. Mach
Lamps and Engineering
Rmax=1900
R700
985
59860002 Edition 11 25.25.2011 / Bak Page 17/19
Wall attachment Mach 120/130 Mach LED 120/130
Dr. Mach
Lamps and Engineering
12. Spare parts
06
17,26
01,02,03
05
23,24 11,26 11,26
13
14
Mach 120
23,24
13
14
09
08 04
07 10
Mach 130
15
16,27(25)
09 08 07
59860002 Edition 11 25.25.2011 / Bak Page 18/19
18,19,20
16,27(25)
21,22
Wall attachment Mach 120/130 Mach LED 120/130
Dr. Mach
Lamps and Engineering
13. Spare parts list
Item Qty. Name Part no. Remark
01 1 Wall bearing 230V / 24V with power supply 60W
Halogen
02 1 Wall bearing 230V / 24V with power supply 60W
LED
03 1 Wall bearing without transformer 74844002 For Mach 130/130F 04 1 Cover for wall bearing 74841003 05 1 Wall bearing panel 74841004 06 1 Cover 74841005 07 1 Circlip (Seegerring) 74011014 08 1 Gib washer 74011013 09 1 Levelling washer 74011012 10 1 Connection cable with safety plug 74015020 11 1 Securing sleeve RAL5021 74013012 Ondal 1502738 12 13 1 Brake screw 74015007 14 1 Securing segment 74015006 15 1 Screw for cover 65112029 16 2 Cover for arm RAL5021 74015022 Halogen lights 17 1 Power supply 60VA inside wall bearing 67010404 Mach 120/120F, mach
18 1 Arm 1-2 kg 74861007 Mach 120/120F 19 1 Arm 2-3 kg 74861008 Mach 130/130F 20 1 Arm 1,8-2,7 kg 74861011 Mach LED 120/120F,
21 1 Lateral cover, left 74015010 Ondal T37284 22 1 Lateral cover, right 74015011 Ondal T38505 23 1 Screw M3x10 D7985 :Zn 65152045 24 1 Lock washer A3,2 65582003 25 1 Sliding contact for new-type swing Ondal T19694 26 1 Securing sleeve RAL 5010 74013122 LED lights 27 2 Cover for arm RAL 5010 74015009 LED lights
74844004 For Mach 120/120F 74844005 For Mach LED
120/120F and Mach LED 130/130F
LED 120/120F, Mach LED 130/130F
Mach LED 130/130F
59860002 Edition 11 25.25.2011 / Bak Page 19/19
Loading...