THE MOST COMMON SYSTEM PROBLEMS ASSOCIATED WITH THE
RM2310,
RM2410,
RM2510, RM2610 , RM2810, RM2452, RM2453, RM2552
AND RM2553 REFRIGERATORS
SYMPTOM
No operation.
1.
2. No electric operation.
3.
No gas operation - no spark.
4. No gas operation
-
sparks but no flame.
CAUSE
Operation Wiring Switch
Operation AC Volts
Heating Element
Thermostat
Switch Wiring
Operation
DC Volts Igniter Electrode High Voltage Cable Switch Wiring
Operation LP gas Filter Orifice
Burner Shut-off Valve Safety Valve
Thermocouple
Thermocouple Adapter,
(Top Mount Controls Only)
5.
No cooling on any mode.
6. No cooling on gas mode(s).
7. No cooling on electric mode(s).
-
cools properly on other
-
cools properly on other
Operation Level Ambient Temperature Cooling Unit
LP Gas
Thermostat
Filter
Orifice
Burner Flue Baffle Flue Tube
AC Volts
Heating Element
Thermostat
Switch Wiring
SYMPTOM
CAUSE
8.
Insufficient cooling on all modes.
9.
Insufficient cooling on electric - cools properly on other mode(s).
Insufficient cooling on gas.
10. Cools properly on other mode(s).
Freezes on electric - cools properly on
11. other mode(s).
Freezes on gas - cools properly on other
12. mode(s).
Operation
Level Ventilation Ambient Temperature Air Leaks
Thermostat
Cooling Unit
AC Volts
Heating Elements
Thermostat
LP Gas Pressure Thermostat
Filter Orifice Burner
Flue Baffle Flue Tube
Thermostat
Wiring
Bypass Screw
Thermostat
Won’t stay lit on gas.
13.
Rapid formation of frost.
14.
No DC operation - cools properly on AC
15. and gas.
Insufficient cooling on DC- cools properly
16.
on AC and gas.
RM251
17.
0/RM261 0/RM2810
On gas mode, sparks while flame is lit.
LP Gas Safety Valve Thermocouple Thermocouple Adapter,
(Top Mount Controls Only) Flame Failure Meter
(Top Mount Controls Only) Flue Baffle Flue Cap (Bottom Mount
Controls Only)
Orifice
Burner Food Storage
Air Leaks
Interior Liner Seal to Frame
High Humidity
DC Volts Heating Element Switch Wiring
Relay (RM261 DC
Volts Heating Element Relay (RM261
Electrode LP Gas Bypass Screw Filter
O/RM2810)
0/RM2810)
REFRIGERATORS WITH
BOTTOM
MOUNT CONTROLS
Refrigerators with Piezo lgnitors (RM2310
A B - Thermostat Gas/Electric c - Safety Push-button D -
Piezo lgnitor
E
&
RM2410)
-
ON/OFF Switch
-
Flame View Port
Refrigerators with Automatic Reigniters (RM251
A - ON/OFF Switch B - Thermostat, Gas/Electric c E - Light
O/RM261 O/RM2610)
Safety Push-button
-
GAS OPERATION
Refrigerators with
To start the
Turn the thermostat knob
Push button
piezo ignitor several times to light the burner. This can be observed through the flame view port, on the refrigerator.
After the flame lights, continue to hold button “C” for an additional fifteen (15) seconds. Release the
button “C” and check the flame view port goes out, repeat the lighting procedure.
To shut off the refrigerator, turn Knob “A” to the “OFF” position.
Refrigerators with Automatic Reigniters (RM2510
To start the refrigerator, turn knob “A” to the “GAS” position. Turn the thermostat knob
Piezo lgnitor (RM2310 & RM2410)
refrigerator, turn knob
“B”
“C”
in until it bottoms out-and hold. While holding button “C”, push button “D” for the
“6”
“A”
to the “GAS”
one-quarter
“E”
one-quarter
position.
(l/4)
of a turn from the “OFF” position.
to make sure the burner does not go out. If the burner
/RM2610
(l/4)
of a turn from the “OFF” position.
/RM2810)
“E”,
Push button “C” in until it bottoms out-and hold. When lamp an additional 15 seconds. Release button “C”. If the lamp
“E”
stops flashing, hold push-button “C”
“E”
starts to flash again, repeat lighting
procedure. If flame blows out, the reigniter will automatically relight the flame.
4
NOTE:After changing an LP tank, or after a long shut off period, the gas line is likely to be filled with air. You may have to repeat the lighting procedure several times to purge the air out of the gas lines.
ELECTRIC OPERATION
Check to be sure the power cord is properly connected to the power supply. If the refrigerator is equipped for 12 volt DC operation, the tow vehicle engine should be running to prevent discharging the battery.
Turn knob “A” to the position marked operation.
“B”
Turn the thermostat knob
To shut off the refrigerator, turn knob “A” to the
one-quarter
“ELEC”
(l/4)
for 120 volt AC operation or
of a turn from the “OFF” position.
“OFF”
position.
“12V”
for 12 volt DC
THERMOSTAT
The refrigerator is equipped with a thermostat that can be adjusted by turning knob
setting to maintain the desired cabinet temperature.
“OFF” Setting of the Thermostat:
burner runs continuously at the bypass rate or pilot. In electrical operation, the contacts in the ther­mostat are open and the heating elements are off.
“MAX” Setting of the Thermostat:
high flame continuously. In electric operation, the heating element is “ON” continuously.
The thermostat can be adjusted between “MAX” and “OFF” to obtain the desired cabinet tempera­ture. The closer the knob is to “MAX”, the colder the cabinet temperature. The closer the knob is to
“OFF”, the warmer the cabinet temperature.
In gas operation, the thermostat closes its main valve and the
In gas operation, the thermostat allows the burner to remain on
“B”
to a different
When the thermostat reaches the set temperature, it will cut the burner back to bypass or, in electric operation, shut off the heating element.
OPERATION
REFRIGERATORS WITH TOP MOUNT CONTROLS
REFRIGERATORS WITH PIEZO IGNITORS: RM2452 AND RM2453
LEGEND: A Energy Selector Knob
B Thermostat Knob
C Flame Failure Safety
Valve Push Button D Piezo lgnitor E Flame Indicator
---_-__-----m-------------v-
REFRIGERATORS WITH AUTOMATIC IGNITION: RM2552 AND RM2553
GAS OPERATION
REFRIGERATORS WITH (RM2452 & RM2453)
1.
To start the refrigerator, turn knob “A” to the “GAS” position. Turn the thermostat knob
2.
3.
Push button “C”, push button
on the flame indicator
4.
After the flame lights, continue to hold button check the flame indicator procedure. To shut off the refrigerator, turn knob “A” to the “OFF” position.
5.
PIEZO IGNITOR
“B”
one-quarter
“D”
for the piezo ignitor several times to light the burner. This can be observed
“E”,
on the refrigerator.
“E”
to make sure the burner does not go out. If the burner goes out, repeat the lighting
(1/4)
of a turn from the “OFF” position.
“C”
for an additional ten (10) seconds. Release the button
“C”
and
REFRIGERATORS WITH AUTOMATIC (RM2552 AND RM2553)
1. To start the refrigerator, turn knob “A” to the “GAS” position.
2. Turn the thermostat knob
3.
Push button button repeat lighting procedure. Should flame blow out, the reigniter will automatically relight the flame.
NOTE: After changing an LP tank, or after a long shut-off period, the gas line is likely to be filled with air. You may have to repeat the lighting procedure several times to purge the air out of the gas lines.
“C”
in until it bottoms out - and hold. When flame indicator
“C”
an additional 15 seconds. Release button “C”. If the flame indicator
“B”
REIGNITERS
one-quarter
(l/4)
of a turn from the “OFF” position.
“E”
shows the flame is on, hold push
“E”
starts to move toward off,
ELECTRIC OPERATION
Check to be sure the power cord is properly connected to the power supply. volt DC operation, the tow vehicle or caravan engine should be running to prevent discharging the battery.
“ELEC”
Turn knob “A” to the position marked Turn the thermostat knob To shut off the refrigerator, turn knob “A” to the “OFF” position.
“9”
one-quarter
for 120 volt AC operation or
(l/4)
of a turn from the “OFF” position.
If the refrigerator is equipped for 12
“12V”
for 12 volt DC operation.
THERMOSTAT
The refrigerator is equipped with a thermostat that can be adjusted by turning knob the desired cabinet temperature.
Setting of the Thermostat:
“OFF” continuously at the bypass rate or pilot. In electrical operation, the contacts in the thermostat are open and the heating elements are off. “MAX” Setting of the Thermostat: In gas operation, the thermostat allows the burner to remain on high flame continuously. In electric operation, the heating element is “ON” continuously. The thermostat can be adjusted between “MAX” and “OFF” to obtain the desired cabinet temperature. The closer the knob is to “MAX”, the colder the cabinet temperature. The closer the knob is to “OFF”, the warmer the cabinet temperature.
In gas operation, the thermostat closes its main valve and the burner runs
“9”
to a different setting to maintain
When the thermostat reaches the set temperature, it will cut the burner back to bypass or, in electric operation, shut off the heating element.
The setting of the thermostat is not critical, but we recommend it be adjusted to maintain a dry frost on the cooling fins. Adjust the thermostat knob closer to “MAX” when the outside temperature becomes warm.
AC VOLTAGEREQUIREMENTS
The proper operating range is 100 to 132 volts. Check the AC volts at the receptacle where the refrigerator is attached.
If voltage drops below 100 volts, cooling efficiency will decrease with voltage decrease.
AC COMPONENTS
HEATING ELEMENT
To check a heating element, remove the heater leads from the terminal block and measure for proper resistance across the two leads.
You should obtain the following readings, plus or minus 10%:
RM2310 92 RM2410 92 RM2510 RM2610 48 RM2810 44
RM2452 69 RM2453 69 RM2552 69 RM2553 69
75
DC VOLTAGE REQUIREMENTS
The operational range is 10.5 to 15 volts DC. Check for proper voltage at the terminal block or blocks at the back of the refrigerator. The power supply to the refrigerator must be fused.
DC COMPONENTS
SWITCH (BOTTOM MOUNT CONTROLS)
A. Remove all wires from the assembly.
For the DC mode, For the AC mode, you
continuity should exist between terminals 1 and 1A and 2 and2A.
should have continuity between 4L and 4A and 5N and 5A.
RM2310 & RM2410 SWITCH ASSEMBLY
DC Mode
AC Mode
(3-Way
Models Only)
DC Mode
AC
-Mode
B.
The RM251
O/RM261 O/RM2810
all wires from the assembly.
selector switch should be checked for continuity in the following manner. Remove
For the DC mode, continuity should exist between terminals
1
and IA and2 and 2A. For the gas mode, you should
have continuity between 3 and 3A.
For the AC mode, you should have continuity between 4L and 4A and 5N and 5A.
RM251
O/RM261 O/RM2810
SWITCH ASSEMBLY
Gas Mode
\
DC Mode
DC
Mode
AC Mode
AC Mode
Gas Mode
SWITCH (TOP MOUNT CONTROLS)
Remove all wires from the assembly. For the DC Mode
(3-Way
Models ONLY), continuity should exist between terminals 5 and 5a and 6 and 6a. For the AC Mode, continuity should exist between terminals 1 and la and 2 and 2a. For the Gas Mode (on refrigerators equipped with automatic
REIGNITERS
ONLY), continuity should exist between
terminals 4 and 4a.
RM2452/RM2453/RM2552/RM2553 SWITCH
Gas Mode
AC
Mode 1
Gas Mode
‘DC
Mode
IGNITER
A. MODEL
When the button is pushed, a spring loaded striker creates a spark. If there is no resistance when pressing the button, the piezo igniter is defective.
RM2310,2410,2452,2453
B. MODEL
RM2510,2610,2810,2552,2553
Check that the switch is in the gas mode and is completing the circuit. Next, verify proper voltage at the positive (+) and ground (-) terminals of the igniter. The reading should be within one volt of incoming voltage at the terminal block.
HIGH VOLTAGE
Disconnect DC power at the terminal block. Remove high voltage cable from igniter. Reconnect DC power, the igniter should produce a sparking sound.
ON MODEL
RM2510,2610
AND 2810:
With the igniter producing spark, set the meter on 20 volts DC or lower scale,
connect meter leads to L and ground terminals on the igniter. The meter should read a pulsating voltage. The pulsating voltage allows a lamp to illuminate on the front of the refrigerator to advise the customer spark has been
produced.
ELECTRODE
Do a visual inspection for cracks or breaks on the ceramic insulator. Also, verify the mounting bracket is attached properly to the electrode. Check the spark gap. It must be set at three sixteenths electrode above the slots in the burner.
ELECTRODE
TlP
(3/16)
of an inch and the tip of
10
HIGH VOLTAGE CABLE
Be sure switch and igniter are good before checking the high voltage cable and the switch is in the gas mode. Disconnect DC power at the terminal block. Disconnect high voltage cable from electrode. Reconnect DC power to the terminal block. If sparking starts, cable is good. If no sparking, disconnect DC power at the terminal block and then disconnect high voltage cable at the igniter. Reconnect DC power to the terminal block.
RELAY (RM261 0/RM2810 3-WAY
MODELS ONLY)
Verify the selector switch is on DC mode and the thermostat is circuit. Verify voltage is present between terminals 85 and 30.
Check for voltage between terminals 85 and 87. If voltage is present, the relay is defective.
NOT
completing the
+
Verify the selector switch is on DC mode and the thermostat is completing the circuit. Verify voltage is present between terminals 85 and 86. If voltage is present, between 85 and 86 terminals, then voltage should be present between
terminals 85 and 87.
A
11
HEATING ELEMENT
(3-WAY
Check the heating element with ohms resistance using a properly calibrated ohm meter. You should obtain the following readings, plus or minus 10%:
A continuity reading will indicate an open or complete circuit.
MODELS ONLY)
RM2310 RM2410 RM2510 RM2610 RM2810
RM2453
RM2553
1.15 OHMS
1.15 OHMS .82
OHMS
.67
OHMS
.67
OHMS
.83
OHMS
.83
OHMS
FLAME INDICATOR METER
If the
millivolts
from the thermocouple are 5 millivolts or more, the red needle in the meter
should
be in the green section.
LP GAS REQUIREMENTS
The LP gas pressure to the refrigerator should be 11 inches water column with half of all BTU’s of the RV turned on. With all other appliances turned off, the pressure to the refrigerator should not
exceed 12 inches water column. To check the gas pressure when
the refrigerator is operating, there is a pressure test housing
located just prior to the orifice.
-
--
*‘-
PRESSURE TEST HOUSING
LP GAS COMPONENTS
SHUT-OFF VALVE
To check the shut-off valve, remove and inspect for any obstructions.
REFRIGERATORS WITH TOP MOUNT CONTROLS
MANUAL GAS VALVE
REFRIGERATORS WITH BOTTOM CONTROLS
MOUNT
/
MANUAL GAS VALVE
MANUAL GAS SHUTOFF VALVE
12
FILTER A filter is located in the inlet fitting to the thermostat. The filter can become saturated and cause a restriction to gas flow. If you suspect a restriction, first verify the thermostat and bypass screw are good.
THERMOSTAT
LP GAS MODE
The thermostat is calibrated by the manufacturer so that at mid-range the cabinet temperature should be approximately 40 degrees Fahrenheit. cabinet of the refrigerator and operate at mid-range setting until the thermostat is satisfied. Check the temperature of the water. It should be approximately40 degrees. to maximum and check the gas pressure at the pressure test port. It should be line pressure, between 11 to 12 inches water column. If you have less than 11 inches of water column pressure, the next step would be to shut off the gas
supply and remove the bypass screw. Then install a bypass screw that does not have the small o-ring on it. Next, turn on the gas supply and take a reading. If the manometer now reads 11 inches of water column, the thermostat is defective and must be replaced. If the bypass screw test shows no change in pressure, the problem lies in the filter, the shut-off valve or the gas supply.
ELECTRIC MODE
On
2-way
models it controls the AC heating element. On 3-way models it controls the DC heating element as well as
the AC heating element. Check the thermostat for continuity.
BYPASS SCREW There are three common sizes of this screw: S-17 (350 BTU), S-14 (325 BTU) and S-l 1 (300 BTU). To check the bypass screw, connect a manometer at the pressure test housing. The pressure on low flame mode should be 2 to 4 inches water column.
To check the calibration of the thermostat,
To check the thermostat for
proper gas
place a container of water in the
flow,
set the thermostat
SAFETY VALVE To check the safety valve, use a known good thermocouple and install into the safety valve. Supply flame to the tip of the thermocouple for 2 to 3 minutes while holding in on the safety valve stem. Remove flame from thermocouple tip and release safety valve stem. The safety valve should hold in for at least 30 seconds.
THERMOCOUPLE
It will produce 14 to 30 millivolts DC in normal operation. To check the thermocouple, use a known good safety valve and attach to the thermocouple. Next, supply flame to the tip of the thermocouple for 2 to 3 minutes while depressing
the safety valve. Remove the flame and release the safety valve. The valve should hold for at least 30 seconds. If it
does not hold the safety valve open for 30 seconds. THERMOCOUPLE ADAPTER
The thermocouple adapter is a device that allows the flame indicator meter to read DC millivolts from the thermocouple.
Remove it from its location and do a continuity test from the terminal to the center post. Continuity should exist. Next,
check for continuity between the terminal and casing. No continuity should exist.
BURNER It should be level and the slots in the burner should be directly below the flue tube. The burner should be cleaned periodically, at least once a year.
FLUE BAFFLE It should be cleaned periodically, at least once a year.
FLUE CAP - BOTTOM MOUNT CONTROLS
It must be properly attached or flame outage could occur.
13
$1
38fll3fll~
*leaA
e
aDuo
y~t?al
112
aq
w-cu
paueal3
‘&xNpo!Jad
33Ult10
S! JOlE?Jatj!J4aJ
SE!
ayl
Xl!4!JO
:SMOllOl
aq
PlnOqS
OCGZWtl OCPZWtl
OlciZWki
0
19ZNtl
0
18ZWkl
ZSPZIW
ESPZWH
zsszwkl
ESSZWtl
palEal
66# 6E#
EP#
E9# 8S#
EP# EP# EP# EP#
‘I(llw!po!Jad
ISt?t3l$??
XXI0
C3L(l
*Jeah
I2
I3SJJO3
JOi
aD!l!JO
SZ!S
l~nlEUJ EN.#
‘V
*a
‘3
:9NlkllM
()zc
6uoJd
6u!
E$E?lU
:(@lO
aqt
,QJ~A
lVNt131X3
3v
Sllon
L&M
paddgba
UO!palOJd
pa66nld
WOJ~
6uoJd
ayl
01
S!ql
3Cl
P=lJ’=’
lVNU31NI
DNltllM
t?
y3oys
~J!F?BB
e og
I(l~)a~!p
oa
*al3sldaceJ
-6nld
s!ql
Il?U!WJal
S!
UO!~3aUUO3
l-IO/\
DNltllM
paJ!~
s!
Jote~aQJla~
aql :UO!~tX3UuO~
6UOJd-aaJqi
pue
SpJEZZEq
AlJadoJd
aq1
PayJEW
Jd
aY101
ayi
aAOUJaJ
JOln3lON
:p
y3Olq
apeW
‘kEllV3H
Jad
(papunoJ6)
papunoJ6
aql
Zl
AeM-E)
leU!UJJal
BU!J!M
S! JOleJa6!JjaJ ~04
6nld
aq
PlnOyS
aalyl
-pUnOJ6
S! uoy3auuo3
3a
SIlOA
WPWI
WeJfhp
y3Olq
Jo!
all1
oa
lapow
noA
-IV101
Wi’lWlXVW
NI
aut
asn lou
~04
alrylsqns
SJB
Apoq
Jaql!a
IO
GU!YJOM
3UlM
~013flClN03
SlEl13W1133d
au1
40 s!ssey3 Jo
0~
au140
HItIN
se
ap!qaA
sJow7puo3
ESSZW~/Ol8ZW~/Ol9ZWtl/OlSZWtl
” I---___’
hm11v8
n n
hElllV8
TYPICAL
2-WAY
WITH PIEZO IGNITER
FOR REFRIGERATORS WITH BOTTOM MOUNT CONTROLS
1
123 VOLTS AC
I20
VOLTS AC
TYPICAL
3-WAY
WITH PIEZO IGNITER
FOR REFRIGERATORS WITH BOTTOM MOUNT CONTROLS
12
12 VOLTS DC
r--Y
VOLTS DC
+z
-------$
120 VOLTS AC
H
THERMOSTAT
JUNCTION BLOCK
15
TYPICAL
FOR REFRIGERATORS WITH
2-WAY
12
VOLTS DC
WITH
BOTTOM
I
!
REIGNITER
MOUNT CONTROLS
120
VOLTS AC
r
12
VOLTS
DC
16
TYPICAL
FOR REFRIGERATORS WITH
3-WAY
WITH
REIGNITER
BOlTOM
MOUNT CONTROLS
AND RELAY
12 Volts DC
‘7
120 Volts AC
I-?
cd/
120 VOLTS AC
TYPICAL
FOR REFRIGERATORS WITH BOTTOM MOUNT CONTROLS
,*---,
( ,___
y,
L
I
P
I-:
:
PP
!1
3-WAY
-fiBLACK
0”
GREEN
GREEN/YELLOW
@
WITH REIGNITER
12
VOLTS
4
12 VOLTS
c-q
e
-o___P @
DC +
DC
+
+I2 VOLT:
120
VOLTS AC
DC
l-9
12
VOLTS DC
+
17
TYPICAL
FOR REFRIGERATORS WITH TOP MOUNT CONTROLS
2-WAY
WITH
PIEZ0
IGNITOR
GROUND
D
O[
@----HEATER 120~
C-TERMINAL BLOCK
120 VOLTS AC
@
@-SWITCH @-THERMOSTAT
AC
@---BLACK
Q-BROWN
3--RED
4-YELLOW/GREEN
@-+xEEN
@-BL.UE
@--MY
8
WHITE
o-
&
120 VOLTS AC
ADAPTER
azl
HUM
HUM
d01
1NnOW
lW3ldA.l
3v
SI:OA
AWM-2
StlOlVtl3Dlkl~3tJ tlOA
tlOllNWk4
SlOtllN03
x!
SllOA
AZ1
-+ 30
I
+
WV3H--@
tKuIMS-@
3 AOZI
t131lN313tl~
MO18
lVNIRM31~
lVlSOWtUHl--@
1
61
TYPICAL
3-WAY
WITH
PIEZO IGNITOR
FOR REFRIGERATORS WITH TOP MOUNT CONTROLS
120
VOLTS AC
12 VOLTS DC
4
Q
+
12V
@-HEATER 12v
@HEATER 120V
C-SWITCH
@-TERMINAL
(&THERMOSTAT
GROUND
DC
AC
BLOCK
&
+
+-
DC
20
TYPICAL
3-WAY
WITH
REIGNITOR
FOR REFRIGERATORS WITH TOP MOUNT CONTROLS
*HEATER 12V
oc
12 VOLTS
120 VOLTS AC
DC
12 VOLTS DC
;ROUNO
21
OTHER
LEVELING
Refrigerators have a type of cooling unit that utilizes an enclosed pump tube surrounded by a solution to protect the assembly. To ensure proper leveling with these models, the vehicle needs to be leveled so it is comfortable to live in. (No noticeable sloping of floor or walls). When the vehicle is moving, leveling is not critical as the rolling and pitching movement of the vehicle will pass to either side of level, keeping the refrigerant from accumulating in the piping.
VENTILATION
In a proper installation there should be zero (0”) clearance surrounding the sides and top of the refrigerator to achieve proper air flow.
In addition, the cooling unit should have the following clearances to the nearest surface made of combustible material:
RM2310 1 RM2410 RM2510 RM2610 RM2810
1/2 1/2 1/2
1/2 RM2452 0 RM2453
0 RM2552 0 RM2553 0
INCH
INCH
INCH INCH
INCH INCH INCH INCH INCH
RM231
O/RM2410
RM2510/ RM2610
/RM2810
/
RM2452/RM2453/RM2552RM2553
n
TURNING VANE
PATH OF AIR FLOW
CLEARANCE FR COMBUSTIBLE MATERIALS
FROM SIDE OF
CLEARANCE
ROM
SIDE OF
AIR LEAKS
Check the gasket on the doors to be sure of a positive air seal. Check that the cooling unit is installed properly.
22
DOOR POSITION
To correct an alignment of the door, loosen the hinge screws slightly, and reorient the door in the proper position.
If the door needs more adjustment than is available through the hinge adjustment, the base can be repositioned to reorient the door.
AMBIENT TEMPERATURE
As the ambient temperature increases, the air temperature in the area of the cooling unit increases.
COOLING UNIT
To check the cooling unit, first verify the AC heating element is good. Then place approximately one gallon of water
inside the refrigerator and place a thermometer in one of the containers of water. Supply 115 volts direct to the AC heating element and operate for at least 12 hours. Check the temperature on the thermometer. It should be at 45 degrees or lower depending on test conditions.
FOOD STORAGE
Rearrange your foodstuffs. It is essential that the shelves are not covered with paper or large storage containers. Always remember to allow for proper air circulation. Odorous or highly flavored foods should always be stored in covered dishes, plastic bags or wrapped in foil or waxed paper to prevent food odors. Vegetables, lettuce, etc., should be covered. NEVER PUT HOT FOOD INTO THE REFRIGERATOR.
HIGH HUMIDITY
High humidity may cause a small amount of condensation to form on the frame of the refrigerator. As the humidity is reduced, the sweating will decrease.
INTERIOR LINER SEAL TO FRAME
There is a seal that is applied to the liner in the area where the metal frame makes contact with the interior liner. Cold air can migrate out to the metal frame.
Clean the metal frame and foil-backed insulation around the refrigerator.
between outer frame and foil-backed refrigerator insulation. Make sure the refrigerator is dry and that the surface
temperatures are above 50°F. Use a clear silicon caulking compound and seal the seam between the refrigerator’s
plastic liner and the metal frame. NOTE:
TO FORM A PROPER SEAL, IT IS IMPORTANT NOT TO LEAVE ANY
GAPS.
Apply
a foil-backed adhesive tape to the joint
DOUBLE DOOR REFRIGERATOR SHOWN WITH DOORS RE­MOVED
23