All rights reserved. Reproduction of any part of this manual in any form whatsoever without Digi-Star’s express written permission is forbidden. The contents of this manual are subject to change without notice. All efforts have been made to assure the accuracy ofthe contents of this manual. However, should any errors be detected, Digi-Star would greatly appreciate being informed of them.The above notwithstanding, Digi-Star can assume no responsibility for errors in this manual or their consequence.
(.005%/ °F.) or (0.009% °C)full scale ±1 outputcount for 0.5 mv/v transducer
ENVIRONMENTAL ENCLOSURE
IP65, IEC 529
WEIGH ALGORITHM
4 internally selectable digital filters tooptimize performance(General, Slow, Fast and Lock-on)
NON-VOLATILE MEMORY
EEPROM for balance
OPERATING TEMP
-29°C to 60°C -20°F to 140°F
D3831 Rev BGT400 User’s Manual 1
Safety DuringUse
SAFETY DURING USE
Caution
Cleaning
Do not use running water (high pressure cleaners, hoses)to clean the indicator.
Charging Battery and Welding
Disconnect all cables from the weighing indicator before charging the battery or welding on the machine. Ifcables are left connected, theweighing indicator and connected load cells could be damaged.
Scale Indicator
Disconnect all cords
2 GT400 User’s Manual D3831 Rev B
Indicator Overview
INDICATOR OVERVIEW
5
8
6
7
1
Note:
See page 17 for installation instructions.
1
- ZERO/BALANCE operation when the scale is empty.
2
- start unloading
unloaded, stores or prints data to serial port when complete
3
- edit name and display weight accumulation value.
2
and stop unloading, indicator displays amount
3
4
.
4
- turns the unit on and off.
5
Net – arrow flashes in net mode.
6
Print – arrow flashes when printing or saving to Data-Down-Loader.
7
Gross – arrow flashes in gross mode.
8
Unload – arrow flashes in unload mode.
D3831 Rev BGT400 User’s Manual 3
Indicator Overview
Bottom Panel
9
- Remote Port
9
- Power Cord Connection
10
- Load Cell Connection
11
- Serial/J905
12
Input/Output devices.
– Optional, for remote display.
– Optional, to communicate with computer and other digital
Pin J905 Connector Signals
1 +5VDC 2 Com #1 Out (Tx) - Computer3 Com #1 In (Rx) - DDL & Computer4 Com #2 Out (Tx) - Printer5 +12 VDC6 Gnd – Available for any Com device7 Com #2 In (Rx) 8 Ground
1011
– +12 VDC.
– Connect cable from the J-Box.
12
4 GT400 User’s Manual D3831 Rev B
Operation
OPERATION
Turn on Indicator
Zero Balance Indicator
1
0
2
1. Press .
1
1. Press and hold for 3 seconds to zero balance indicator.
2. Flashing arrow points to gross next to the display window, indicator ready to weigh.
D3831 Rev BGT400 User’s Manual 5
Operation
Loading and Unloading
Note:For best accuracy park scale on
level surface and allow weight reading to stabilize before Zero balancing the scale and before beginning to unload.
2
4
4
1. Load cart.
2. Press to begin unloading. Display reads Zero. Arrows point to Net and Unload.
3. Unload weight from cart. Display shows amount unloaded.
4. Press . after unloading is complete. Data is automatically added to accumulator and saved to printer or DDL (See print format section, page 8); a flashing arrow will point to PRINT.
Note: Print and accumulator featuresare available with Serial Option only.
5. Indicator displays GROSS weight remaining on scale.
5
6 GT400 User’s Manual D3831 Rev B
Operation
Field ID
6 character identification value stored in internal memory of indicator to identify field being unloaded, truck being loaded or other information.
2
3
1
4
1. Press .flashing cursor or character is displayed in the first position.
2. Press to scroll available characters. Hold for 4 seconds to increase second scroll rate.
3. Press to scroll backwards through available characters. Press to move to the next character.
4. Press to accept and save.
FIELD
is displayed and a
D3831 Rev BGT400 User’s Manual 7
Operation
Print Formats
Three print formats are available to output or printer.
PRTAC1:PRTAC2:
PRTAC3:
See “Menus and Calibration” (see page 11) to change print format (PRTFMT).
FIELD ID, 4856, GR, 274575, PA, 05FE08, I:44PFIELD ID, 05FE08, I:44P 4856, GR, 274575, PA
Includes following information:
•
Field ID
•
Weight
•
Weight Tag (NE, GR, Load/Unload)
•
Accumulated Weight
•
Print Accumulator Tag
•
Date and Time
FIELD3, 5977, LB, ,GR, 3097I9,PA,05FE08, 4:42P
Includes above and adds “Unit of Measure”.
PRTACC
value and
FIELD ID
to DDL
8 GT400 User’s Manual D3831 Rev B
Operation
Saving/Printing Gross Weights
(Optional w/ Serial Option)
1
Turning Off the Indicator
1. Press and hold three seconds to send weight to serial port.
Each time this command is executed the value displayed is added to the
“PRTACC”
weight. Weight is accumulated until cleared.
1. Press until “
which is the accumulated
BYE
” is displayed.
bye
1
D3831 Rev BGT400 User’s Manual 9
Weighing Errors
WEIGHING ERRORS
Over-Capacity Limit (
The display shows the message "OVRCAP" if the weight on the scale system exceeds the capacity limit. The capacity value is entered in SETUP to warn of overloading the scale system.
Over Range (
The display shows the message "+RANGE" if the weight on the scale system exceeds the maximum weight measurable by the scale system. The over range value is always the system’s maximum A/D counts multiplied by the scaling factor. The actual weight at which over range occurs depends on the calibration, zero, and display count size.
Under Range (
The display shows the message "-RANGE" if the weight on the scale system isless than the minimum weight measurable by the scale system. The under range value is always the system’s minimum A/D counts multiplied by the scaling factor. The actual weight at which under range occurs will depend on the; calibration, zero, and display count size.
+RANGE
-RANGE
Low Battery Indication (
If the supply voltage drops below the (10.5 Volts), the message
BATTERY - TURNING OFF”
alert the operator of the low battery condition.
RUN SELF TEST
1
)
and
OVRCAP
)
“
LO BAT
)
LO BAT
)
“
RECHARGE
”
will periodically show on the display to
1. Press 3 seconds until the LB symbol starts to blink. Release.
2. Press to start the Self Test.
10 GT400 User’s Manual D3831 Rev B
Menus and Calibration
MENUS AND CALIBRATION
The Indicator has optional settings that allow flexibility in the way that the scale is used and data is collected.
Changing Options Using Long Form Setup
Enter Long Form Setup by holding and for three seconds.
Press to advance to desired menu 1,2,3,4,CALIB, or EXIT,
press to select.
Press to advance to desired setting.
Press to advance setting to desired option.
Press to save setting option and advance to next setting.
Hold and press to return to normal indicator operation. Default settings from the factory vary with options and due to customer
preferences.
SETTING
[display]
MENU 1. BASIC FEATURES IN MOST INDICATORS
LANGUAGE
(langag)
DISPLAY RATE
(0 rate)
FIELD ID (FIELD)
D3831 Rev BGT400 User’s Manual 11
OPTIONS [displayed]
BOLD=DEFAULT
English
Dutch
French
German
Italian
Portuguese
Spanish
Danish
Hungarian
(MAGYAR]
Spanish
I,2,3,4
NEW EZ
[ENGLSH)
[NEDERL][FRANCS] [DEUTSH]
(ITAL]
(PORT] (ESPAN](DANSK]
(VESTA]
DESCRIPTION
Select language to be displayed.
Update display times per second.
Identity of FIELD location, Truck ID or Grain Cart ID.
Menus and Calibration
SETTING
[display]
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
MENU 2. CLOCK, PRINTER, COMMUNICATIONS & ESTIMATED
Perform the Zero/Balance for SCOREM #11 weight output and Analog Output Option (4-20mA).
Choose the number of seconds the printer will delay before advancing to the next print line. Choose the number of seconds the printer will delay before advancing to the next print line. Reset Print Accumulator
MENU 3. SCALE CALIBRATION SETTINGS
DISPLAY COUNT
(
COUNT
)
DISPLAY UNIT
(lb-kg)
CAPACITY
(cap)
.0I,.02,.05,.I,.2,.5,I,2,5,I0,20,50,I00
LB
/ KG
85000
Count set too small, readings unstable and indicator not accurate
Unit of measure. When changing weight unit using long form, calibration is adjusted so scale displays accurately in new display unit.
Enter MAXIMUM weight measurable on scale.
MENU 4 – NOT USED
D3831 Rev BGT400 User’s Manual 13
Short Form Calibration
SHORT FORM CALIBRATION
The Short Form Setup & Calibration procedure allows you to change “SETUP” and “CAL” numbers of indicator. Do not attempt to calibrate scale if indicator is not reading stable weights. Calibration procedure will not fix instability, inconsistencies, or flashing "RANGE" messages.
Obtain Current Set-up and Calibration Number
Write down current SETUP and CAL numbers of your GT 400 indicator. These numbers are displayed during Self Test.
3
2
1
SETUP NUMBER
1
To run self test with indicator ON:
1. Press until LB symbol startsto blink. Release, then press to start Self Test.
2. Press to “pause” the Self-Test while numbers are displayed.
3. Press again to allow self-test to complete normally.
SETUP # _______________ CAL # ________________
Following is a list of functions that are controlled by the “SETUP” number:
Weigh Method (Display Units (Display Counts (
14 GT400 User’s Manual D3831 Rev B
W MTHD
) Gain
LB-KG
) Scale Capacity
COUNT
)
Short Form Calibration
CALIBRATION NUMBER
The “CAL” number is adjusted to make scale read proper weight for different load cells and to make accuracy adjustments on a scale system. Systems should be checked with known weights and adjusted if necessary to insure accuracy. Both setup and calibration numbers are changed to convert a scale from lbs to kgs.
Calibrating Scale For Maximum Accuracy
Note:To accurately calibrate scale, you need a large amount of weight that
has a known value. For best results you should have at least as much weight as largest load you plan to weigh.
Determining New Setup and Calibration Numbers
1
The setup number does not change.
1. Press to Zero-Balance.
2. Put KNOWN WEIGHT on scale platform and write down DISPLAY WEIGHT.
Perform following equation to find ACCURATE CAL NUMBER.
D3831 Rev BGT400 User’s Manual 15
Short Form Calibration
Enter A New Setup And Calibration Number
11
4
3
1. Press and hold and for 3 seconds to enter short form calibration.
2. The display will flash “then display the 6-digit setup number with the right digit flashing.
3. Press several times to
5
6
increment digit to it proper value.
4. Press to advance digit left.
Repeat steps 3 and 4 for each digit as required.
5. Press to enter new setup number and display calibration number.
Repeat steps 3 and 4 to modify the calibration number.
6. Press to enter new calibrationnumber and display will go back to normal.
7. Verify the accuracy of scale.
SETUP
” and
16 GT400 User’s Manual D3831 Rev B
Installation
INSTALLATION
Indicator Mounting
RAIL MOUNTWING MOUNTWEDGE MOUNT
STANDARD
KEY PART NUMBER DESCRIPTION
A 403769BRACKET – STR TOP MOUNT
B 403980BRACKET – ROBO MOUNTINGC403770BRACKET – WING MOUNTD405069U-BOLT, 1/4-20 X 3.25 ZP E 403771MODIFIED PLASTIC WEDGE MOUNTF 405124WEDGE MOUNT BRACKET, INCLUDES U-
BOLTS & NUTS
G 405084NUT, 1/4-20 TOP LOCKING FLANGE
Optional Ram Mounting
RAM MOUNT
STANDARD
KEY PART NUMBER DESCRIPTION
A 403180RAM MOUNT B 403179MOUNT BASE-1" BALL U-BOLTC404230RAM SUCTION CUP W/TWIST LOCK
ColorDescription 1 White Signal + 2 GreenSignal - 3 RedExcitation + 4 BlackExcitation - 5 Shield Shield
Tighten Nuts
J-Box Illustrated for 4 Load Cell Installation
J-Box Cable
Load Cell Cable
Connect to Indicator bottom Panel.
J-Box Connections
Load Cell Direction
Observe direction of arrow when installing load cell.
Indicator Calibration
If you connect an indicator to a different weighing implement, the calibration and setup number may need to change. Refer to calibration procedures (seepages 14-16) or contact your Digi-Star representative for assistance.
D3831 Rev BGT400 User’s Manual 19
Optional Equipment
OPTIONAL EQUIPMENT
Data Transfer Options
Remote Indicators
Kit Data Down Loader
Allows transfer of data from indicator to PC. (Optional serial/J905 port must already be installed in indicator)
RD440 small remote display RD2400V backlit remote display with
1.7” high numbersRD2400V backlit remote display
w/transmitter and installed receiverRD4000 remote display
20 GT400 User’s Manual D3831 Rev B
Troubleshooting
p
)
)
g
j
TROUBLESHOOTING
FLOW CHART
START
YES
Does theindicator come on?
NO
Is the reading on the
Indicator stable?
YES
Put your weight on each
load cell. Does theindicator
respondto your weight?
YES
Are the readings
all positive? If not
Load Cell is
u
side down.
Does the scale weigh you approx. thesame over all
Load Cells? (Weight will
not be accurate
YES
Your Indicator is probably not set-up
and calibrated correctly. Check the
decal on the bottom of Indicator.Itshows what type of Load Cellsthe
Indicator was calibrated to. By
pressing the onkey while the
Indicator isalready on, you will get
the Indicator’s “Set-up” and “Cal”
numbers. See if they compare to the
set-up and calibration numbers on
the Indicator. Contact Dealer for
further information.
NO
Check all J-Box
and Load Cell
cables forcuts
or pinched/flat
spots.
NO
If your display is unstable, or
flashes “±RANGE”disconnect
the j-box cord from Indicator.
Is display still unstable?
NO
Your Indicator is probably
cables are not attached to
Remove the cover from your J-Box
Is there moisture inside the box?
Look for loose connections.
Watch your Indicator display
while moving the wires and
pressingon the circuit board
inside the J-Box. You will see
if there is a loose connection
or bad solder
YES
defective. Try another
Indicator to verify.
Be aware of electrical
interference that might
affect Indicator, suchas
mobile phones, CB
radios, radiotowers,
electrical motors, etc.
Make sure Load Cell
hydraulic lines or
reservoir.
NO
Note:
oint.
Poor Connection
apart and clean connections.(Rust or paintshould be wire
brushed.) Then reconnect and
tighten securely.
Bad Battery:
(weak battery may test good iftested with no loadon battery)
Bad Power Cord:
red wire isconnected to (+)positive side and black wire isconnected to (-) negative side.
When using a multimeter to
check for voltage, measurebetween pin 1 (pos) and pin 2
(neg). Meter should read
between 10.5 and14.5 volts
DC if using a tractor power
cord, black wire ispositive and
white wire is negative.
Bad Indicator:
Indicator. (Even a different
model or set-upshould come
Dry out your J-Box (use a
hairdryer). Checkcable strain reliefs for tightness.Cables have drip loops.Is
lid
asket damaged?
: Take them
Replace battery
Make sure
Try another
on.
YES
Fix or replace the J-Box
Did theJ-Box have a bad
YES
connection or loose wire?
NO
See next Page
D3831 Rev BGT400 User’s Manual 21
,
y
p
p
FLOW CHART
Continued
1. Disconnect all the Load Cell wires from theterminal blocks
inside the J-Box (leave the
Indicator on while connecting
and disconnecting the wires, it
will not damage Load Cells or
Indicator if wires are shorted
during this step). Is reading on
Indicator stable?
NO
Replace J-Box
(be aware of electrical
interference that might affect
your scalesuch as: mobile
phones, CB radios, radio
electric motors, etc.).
towers
4. Record the Indicator reading with the Load Cell connected.
5. Stand or hang your weight over the connectedLoad Cell. Recordhow much the weight
increased with your weight over the Load Cell. (A
scale with only one Load Cell will weigh heavy.)
2. Zero balancethe Indicator.(Press “NET/GROSS” then
“ZERO”). Indicatorshould display
“0”.
YES
Note:
Hook up theLoad Cells to theJ-Box one ata time (only one Load Cell connectedat atime).This will get a reading for each Load Cell. While
performing this test, watch for any other
symptoms such as erratic/unstabledisplay. Indicator flashing“±RANGE”, negative reading,etc. Ifthe Indicatorreading should ever appear
abnormal with any Load Cell connected then itis
probably bad.
3. Connect one Load Cell backinto one ofthe
terminals inthe J-Box. (The reading you get for
each Load Cell is dependent on the size and type
of each Load Cell and how much weight is over
each Load Cell. Ingeneral,the number should be
Note:
that’s verification on the J-Box is OK. Ifthe
scale did not respond, eitherthat Load Cell is
bad or the J-Box isbad. Try the other Load
Cells. If theIndicator stillshows no response,
positive and stable.)
If the scale respondedto your weight,
the J-Box is bad. (Replace J-Box)
6. Disconnect the first Load Cell and reconnect
7. Repeat step 6 for the remaining Load Cells.Remember to record
our readings.
a second one. Record the Indicator reading.
Stand or hang your weight over theconnected
Load Cell. Recordhow much the weight
increased.
Do not expect the Load Cells to give the same
reading.It iscommon for Load Cells to have
readingsthat vary by hundreds, even thousands.
Es
ecially when one iscarrying more weight.
8. Bad Load Cellswill have a reading that iseitherunstable,makes the indicator flash
“±RANGE” or is more than threetimesgreater
or lessthan the average ofthe others.Also the
readings of your weight over each Load Cell
should be similar. (Probably 4 times your actual
weight). Any differences could be an indication
of a bad Load Cellor a structural
roblem.
22 GT400 User’s Manual D3831 Rev B