All rights reserv ed. Reproduction of any part of this manual in any form whats oever without Digi-Star’s expr ess written permission is forbi dden. The
contents of this m anual are su bject to change withou t notic e. All eff orts h ave bee n made to assur e the ac curac y of t he conten ts of t his manu al. Ho wever,
should any errors be detected, Digi-Star would greatly appreciate being informed of them. The above notwithstanding, Digi-Star can assume no
responsibility for any errors in this manual or their consequence.
The DTU software allows you to send data from your Digi-Star indicator to your PC. The DTU
software can work with all Digi-Star communication devices (DataKey, DDL module and Memory
Card). It also allows you to connect your indicator directly to you PC and receive streaming data or
send commands.
Follow the installation instruction on Page: 2. Select the communication device that you use and
follow the manual instructions. Check the indicator manual for the data and print formats that you
can send to your PC.
Minimum System Requirements
Make certain that your system includes the following hardware and software. These are
the minimum system requirements to run DTU
• A Pentium
• Microsoft Windows 95/98 and higher
• 100 Meg Free disk space
• 32 Meg Ram
• CD Drive
• A serial port*/USB to serial Adapter
• Printer
• Internet connection
100 or better PC
D3912-GB Rev A DTU Software manual
2
Install Software:
1. Insert the DTU CD into your CD-ROM drive.
2. From your Windows start menu, select RUN.
3. Select BROWSE on your CD drive, select Setup.exe.
4. Click Open.
5. Click OK.
6. Follow the installation prompts from the software.
Install software
D3912-GB Rev A DTU Software manual
3
Data Transfer Utilities
Main screen
Data Transfer Utilities
Explanaition of butons
- All DataKey functions
- All DDL functions
- All Mem Card function
- Streaming data
- Scale Data logger
- Scale emulator
- Help menu
D3912-GB Rev A DTU Software manual
4
Settings
System settings
Data Transfer Utilities
• Com Port Settings: This is the pre-defined port. Choose “Auto Find” to automatically find
the Com Port the device is connected to.
• File Location: This is the default location on your PC where the data will be saved
• File Type: This is the default file type.
• Preferred Hardware: Select the hardware device that you use. Check the “Filter Hardware”
box to only show the selected hardware device on the main screen
D3912-GB Rev A DTU Software manual
5
Language
• Select desired language
Help
Data Transfer Utilities
• About: shows software version information
• Check for updates: Check on line for available updates
• Digi-Star EZ connect: For on line support
• Visit Digi-Star on the web: Go to Digi-Star web site
• DTU Help: View help files
D3912-GB Rev A DTU Software manual
6
Data Transfer Utilities
DataKey operations
The DataKey can be used for sending and receiving feeding and group data to your Digi-Star
EZ3600V and EZ4600 indicators.
• Clear DataKey: Delete all data from DataKey
• DataKey status: This will get the current status of a Digi-Star DataKey that is connected to
your PC via a Docking Station
Read/View DataKey
o Click the arrows button to retrieve the information from the Digi-Star DataKey
o Click the Save button to save what is on-screen.
o Click the Delete button to delete what is on-screen.
D3912-GB Rev A DTU Software manual
7
Make DataKey
Data Transfer Utilities
o Choose the Feeding Mode that you want to feed in. (list or Loads mode)
o Choose the Feeding number.
o Enter the Recipes – enter all ingredients of each recipe
o Enter the groups you want to feed
o Check the Recipe that you want to send to the DataKey
o Check the Group(s) that you want fed that recipe to.
o Click the
o Click the button to send the Feed lines to a Digi-Star DataKey
o Click the button to send the Feed lines to a U SB
o Click the to Save the Feed lines to your PC
o Click the to load in Feed lines that were previously saved to your PC
• Authorize DataKey: Authorize DataKey (Contact you dealer before using this function)
• Test DataKey: Test DataKey
D3912-GB Rev A DTU Software manual
8
Data Transfer Utilities
DDL operations
The DDL can be used for transferring weight, feeding, field and other information from the Digi-Star
GT400, EZ2400V and EZ3400V indicators to a PC.
Check the indicator manual for the available data print formats.
Note: In order to store data from the indicator to the DDL, the DDL module has to be connected to
the serial port of your indicator at any time. The indicators mentioned above have NO internal
memory so without the DDL installed no data will be stored.
Use the in the DDL kit included serial cable (and if required USB converter) to connect DDL
module to PC.
Read/View DDL
o Click to Read the DDL
o Click to Save what is on screen
o Click to Delete what is on screen
• Clear DDL: Delete all data from DDL
• Test DDL: Test DDL
D3912-GB Rev A DTU Software manual
9
Mem Card operations
For use with the Tyrell feeding system.
Read Mem Card
Data Transfer Utilities
• Click to Read the Mem Card
• Click to Save what is on screen
• Click to Delete what is on screen
D3912-GB Rev A DTU Software manual
10
Data Transfer Utilities
Streaming Data
The Streaming Data screen is designed to send and receive information through a RS232
connection and display/save that information.
• Step 1 – Set the Communication Port
• Step 2 – Start/Open the Communication Port by clicking
o Click the button to pause the process.
o Information will be displayed in:
o You can click the Save button to save and the Delete button to clear this area.
o You can also select following to filter the results
D3912-GB Rev A DTU Software manual
11
• Information is also displayed as
o Trace will “turn on” and “turn off” this window.
o Decimal/Hex Based: when your mouse “hovers” over an item, an automatic window
will display the value.
o Time Recorded: displays how long you have been Sending/Receiving information
o You also have the ability to Save/Print in many formats using the buttons on the
right.
Sending Information
Data Transfer Utilities
• EZ1 Commands: Listing of all Digi-Star EZ1 commands
• EZ2 Commands: Listing of several of the Digi-Star EZ2 Commands
• Custom Command: Ability for you to build/send any command
• Run Scripts: Ability to read in a Text file that contains a list of commands and send them
out one at a time.
• Simulation: Ability to read in a Text file that contains a list of commands and send them at
a specific frequency.
D3912-GB Rev A DTU Software manual
12
Data Transfer Utilities
Scale Emulator
The scale emulator allows you to view the selected indicator by selecting indicator and com port.
o Press close to exit.
D3912-GB Rev A DTU Software manual
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.