Desa FAS-3B, FAS-5B User Manual

Page 1
INFRARED VENT-FREE NATURAL GAS HEATER
OWNER’S OPERATION AND INST ALLATION MANUAL
FA-3B FAS-3B FA-5B FAS-5B
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal in­jury, or loss of life.
— Do not store or use gasoline or other
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed
by a qualified installer, service agency, or the gas supplier.
®
WARNING: Improper in­stallation, adjustment, al­teration, service, or mainte­nance can cause injury or property damage. Refer to this manual for correct in­stallation and operational procedures. For assis­tance or additional infor­mation consult a qualified installer, service agency, or the gas supplier.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is in­stalled. Provisions for ad­equate combustion and ventilation air must be pro­vided. Refer to
Air For Combustion and Ventila­tion
section on page 4 of
this manual.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
Page 2
INFRARED NATURAL GAS HEATER
SAFETY INFORMATION
WARNINGS
IMPORTANT: Read this Owner’s Manual carefully and completely before trying to assemble, oper­ate, or service this heater. Im­proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early
signs of carbon monoxide poisoning re­semble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, per­sons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Natural Gas: Natural gas is odorless. An odor-making agent is added to natural gas. The odor helps you detect a natural gas leak. However, the odor added to natural gas can fade. Natural gas may be present even though no odor exists.
Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
WARNING: Any change to this heater or its controls can be dangerous.
1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
2. If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. F ollow the gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department
3. This heater shall not be installed in a bedroom or bathroom.
4. Never install the heater
• in a recreational vehicle
• where curtains, furniture, clothing, or
other flammable objects are less than 36 inches from the front, top, or sides of the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
5. Always run non-thermostat heater with plaque control knob in a locked posi­tion. Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.
6. This heater needs fresh, outside air ven­tilation to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Fresh Air for Comb us- tion and Ventilation, pages 4 through 6.
7. Keep all air openings in front and bot­tom of heater clear and free of debris. This will insure enough air for proper combustion.
8. If heater shuts off, do not relight until you provide fresh, outside air . If heater keeps shutting off, have it serviced.
9. Do not run heater
• where flammable liquids or vapors
are used or stored
• under dusty conditions
10. Before using furniture polish, wax, car­pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow­der residue within burner box or on adjacent walls or furniture.
11. Never place any objects on the heater.
12. Surface of heater becomes very hot when running heater. K eep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut-down. Allow surface to cool before touching.
13. Carefully supervise young children when they are in same room with heater.
14. Make sure grill guard is in place be­fore running heater.
15. Do not use heater if any part has been under water. Immediately call a quali­fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
16. Turn of f and unplug heater and let cool before servicing. Only a qualified ser­vice person should service and repair heater.
17. Operating heater above elevations of 4,500 feet could cause pilot outage.
2
105566
Page 3
OWNER’S MANUAL
PRODUCT IDENTIFICATION
Front Panel
Control Knob
Grill Guard
Burners
Heater Cabinet
PRODUCT FEATURES
SAFETY DEVICE
This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent­free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
THERMOSTATIC HEAT CONTROL ON THERMOSTAT MODELS FAS-3B AND FAS-5B
These heaters have a control valve with a thermostat sensing bulb. This results in the greatest heater comfort and may result in lower gas bills.
Figure 1 - Vent-Free Natural Gas Heater (Model FA-5B Shown)
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code ANS Z223.1, also known as NFPA 54*.
*Available from: American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
1. Remove heater from carton.
2. Remove all protective packaging ap­plied to heater for shipment.
3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.
105566
3
Page 4
INFRARED NATURAL GAS HEATER
FRESH AIR FOR COMBUSTION AND VENTILATION
WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ven­tilation air. Read the following in­structions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy effi­cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com­bustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad­equate fresh air for these appliances. This will insure proper venting of vented fuel­burning appliances.
PRODUCING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code, NFPA 54/ANS Z223.1, Sec­tion 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space The information on pages 4 through 6 will
help you classify your space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and win­dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is de­fined as construction where:
a. walls and ceilings exposed to the
outside atmosphere have a con­tinuous water vapor retarder with a rating of one perm (6 x 10 per pa-sec-m2) or less with open­ings gasketed or sealed
b. weather stripping has been
added on openable windows and doors
c. caulking or sealants are applied
to areas such as joints around window and door frames, be­tween sole plates and floors, be­tween wall-ceiling joints, be­tween wall panels, at penetra­tions for plumbing, electrical, and gas lines, and at other openings.
If your home meets all of the three criteria above, you must provide ad­ditional fresh air. See
From Outdoors
If your home does not meet all of the three criteria above, see
Fresh-Air Flow for Heater Location,
page 5
and
, page 6
Ventilation Air
.
Determining
and
-11
kg
Confined and Unconfined Space
The National Fuel Gas Code (ANS Z223.1, 1992 Section 5.3) defines a confined space
as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfining space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are in­stalled*, through openings not furnished with doors, are considered a part of the unconfined space.
This heater shall not be installed in a con­fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
* Adjoining rooms are communicating only if there are doorless passageways or ventila­tion grills between them.
4
105566
Page 5
OWNER’S MANUAL
FRESH AIR FOR COMBUSTION AND VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Determining if You Have a Confined or Unconfined Space
Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between
the rooms.
1. Determine the volume of the space (length x width x height). Length x Width x Height = ____________________ cu. ft. (volume of space)
Example:
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
_________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example:
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free heater ___________________ Btu/Hr Gas water heater* ___________________ Btu/Hr Gas furnace ___________________ Btu/Hr Vented gas heater ___________________ Btu/Hr Gas fireplace logs ___________________ Btu/Hr Other gas appliances* +__________________ Btu/Hr Total =__________________ Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
____________Btu/Hr (maximum the space can support) ____________Btu/Hr (actual amount of Btu/Hr used)
Example:
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin-
ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)
Example:
Gas water heater 40,000 Btu/Hr Vent-free heater + 18,000 Btu/Hr Total = 58,000 Btu/Hr
51,200 Btu/Hr (maximum the space can support) 58,000 Btu/Hr (actual amount of Btu/Hr used)
WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the
105566
National Fuel Gas Code, ANS Z223.1, 1992, Section 5.3
5
or applicable local codes.
Continued
Page 6
INFRARED NATURAL GAS HEATER
FRESH AIR FOR COMBUSTION AND VENTILATION
Continued
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro­vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op­tion 3, Figure 2). Follow the National Fuel
Gas Code NFPA 54/ANS Z223.1, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
WARNING: Rework work­sheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.
Ventilation Grills
Ventilation
Grills
into Adjoining
Room,
Option 1
Figure 2 - Ventilation Air from Inside Building
Or
Remove Door into Adjoining
Room,
Option 3
Into Adjoining Room,
12"
12"
Option 2
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two per­manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.
IMPORTANT:
inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.
Do not provide openings for
Outlet Air
Ventilated Attic
Outlet Air
Inlet Air
Inlet Air
Figure 3 - Ventilation Air from Outdoors
6
To Attic
To
Crawl
Space
Ventilated
Crawl Space
105566
Page 7
OWNER’S MANUAL
36"
2"
FLOOR
CEILING
Minimum
Minimum to Top Surface of Carpeting, Tile or Other Combustible Material
8" Minimum From Sides Of Heater
Left Side
Right Side
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri­mary heating system. Do not in­stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater . This will help circu­late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
NOTICE: A qualified service per­son must install heater. Follow all local codes.
CHECK GAS TYPE
Use only natural gas. If your gas supply is not natural, do not install heater. Call dealer where you bought heater for proper type heater.
INSTALLATION ITEMS
LOCATING HEATER
This heater is designed to be mounted on a wall.
WARNING: Maintain the mini-
mum clearances shown in Figure
4. If you can, provide greater clear­ances from floor, ceiling, and joining wall.
You can locate heater on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer. See Accessories, page 19.
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
IMPORTANT:
Vent-free heaters add mois­ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Fresh Air for Com- bustion and Ventilation, pages 4 through 6.
For convenience and efficiency, install heater
• where there is easy access for operation,
inspection, and service
• in coldest part of room An optional fan kit is available from your
dealer. See Accessories, page 19. If plan­ning to use fan, locate heater near an electri­cal outlet.
Before installing heater, make sure you have the items listed below.
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• manual shutoff valve *
• ground joint union
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench * An A.G.A. design certified manual shutoff
valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur­chase the optional A.G.A. design certified manual shutoff valve from your dealer. See Accessories, page 19.
CAUTION: If you install the
heater in a home garage
• heater pilot and burner must be at least 18 inches above floor
• locate heater where moving ve­hicle will not hit it
CAUTION: This heater cre­ates warm air currents. These currents move heat to wall sur­faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as to­bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.
Figure 4 - Mounting Clearances As Viewed From Front of Heater
105566
Continued
7
Page 8
INFRARED NATURAL GAS HEATER
17 3/8"
17 1/2"
Min.
6
1
/2"
Min.
Adjoining Wall
Only Insert Mounting Screws Through Last
Hole On Each End
Floor
INSTALLATION
Continued
INSTALLING HEATER TO WALL
Mounting Bracket
The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel.
Mounting Bracket
Figure 5 - Mounting Bracket Location
Removing Front Panel Of Heater Models FAS-3B and FAS-5B
1. Remove two screws near bottom cor­ners of front panel.
2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4".
3. Pull bottom of front panel forward, then down (see Figure 6).
Figure 6 - Removing Front Panel of Heater (Model FAS-3B Shown)
Removing Front Panel Of Heater Models FA-3B and FA-5B
1. Remove two screws near bottom cor­ners of lower front panel.
2. Pull bottom of lower front panel for­ward, then down (see Figure 7).
Figure 7 - Removing Front Panel of Heater (Model FA-5B Shown)
Methods For Attaching Mounting Bracket To Wall
Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall in one of two ways.
1. Attaching to wall stud
2. Attaching to wall anchor
Attaching to Wall Stud This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.
Attaching to Wall Anchor This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).
Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.
Marking Screw Locations
1. Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.
WARNING: Maintain minimum clearances shown in Figure 8. If you can, provide greater clear­ances from floor and joining wall.
2. Mark screw locations on wall (see Fig­ure 8).
Note:
Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.
3. Remove tape and mounting bracket from wall.
1
10
/4"
Min.
Only Insert Mounting
Screws Through Last
Adjoining Wall
Figure 8 - Mounting Bracket Clearances
Hole On Each End
Model FA-5B, FAS-5B
Model FA-3B, FAS-3B
17 3/8"
Floor
17 1/2"
Min.
8
105566
Page 9
OWNER’S MANUAL
INSTALLATION
Continued
Attaching Mounting Bracket To Wall
Note:
Wall anchors, mounting screws, and spacers are in hardware package. The hard­ware package is provided with heater.
Attaching to Wall Stud Method
For attaching mounting bracket to wall studs
1. Drill holes at marked locations using
9/64" drill bit.
2. Place mounting bracket onto wall. Line
up last hole on each end of bracket with holes drilled in wall.
3. Insert mounting screws through bracket
and into wall studs.
4. Tighten scre ws until mounting bracket
is firmly fastened to wall studs.
Attaching to Wall Anchor Method
For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)
1. Drill holes at marked locations using
5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep.
2. Fold wall anchor as shown in Figure 9.
3. Insert wall anchor (wings first) into
hole. Tap anchor flush to wall.
4. For thin walls (1/2" or less), insert red
key into wall anchor. Push red key to “pop” open anchor wings (see Figure
10).
IMPORTANT:
key!For thick walls (over 1/2" thick) or solid walls, do not pop open wings.
5. Place mounting bracket onto wall. Line
up last hole on each end of bracket with wall anchors.
6. Insert mounting screws through bracket
and into wall anchors.
7. Tighten scre ws until mounting bracket
is firmly fastened to wall.
Do not hammer
Figure 9 - Folding Anchor
Figure 10 - Popping Open Anchor Wings For Thin Walls
Placing Heater On Mounting Bracket
1. Locate two horizontal slots on back panel of heater (see Figure 11).
2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.
Horizontal Slots
Stand-Out Tab
Figure 11 - Mounting Heater Onto Mounting Bracket
Mounting Bracket (attached to wall)
Installing Bottom Mounting Screws
1. Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see Figure 12).
2. Mark screw locations on wall.
3. Remove heater from mounting bracket.
4. If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 un­der Attaching To W all Anc hor Method. If installing bottom mounting screw into wall stud, drill holes at marked lo­cations using 9/64" drill bit.
5. Replace heater onto mounting bracket.
6. Place spacers between bottom mount­ing holes and wall anchor or drilled hole.
7. Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole.
8. Tighten both screws until heater is firmly secured to wall. Do not over tighten.
Note:
Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 10 and 11).
Figure 12 - Installing Bottom Mounting Screws
105566
Continued
9
Page 10
INFRARED NATURAL GAS HEATER
INSTALLATION
Continued
CONNECTING TO GAS SUPPLY
NOTICE: A qualified service per­son must connect heater to gas supply. Follow all local codes.
WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as well-head gas.
IMPORTANT:
fore connecting heater to gas line. Gas line pressure must be no greater than 14 inches of water. If gas line pressure is higher, heater regulator damage could occur.
CAUTION: Use only new, black iron or steel pipe. Inter­nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of large enough diameter to allow proper gas volume to heater. If pipe is too small, undue loss of pres­sure will occur.
Typical Inlet Pipe Diameters
FA-3B/FAS-3B 3/8" or greater FA-5B/FAS-5B 1/2" or greater
Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
Check gas line pressure be-
Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sedi-
IMPORTANT:
with wrench when connecting it to gas pip­ing and/or fittings.
Hold pressure regulator
ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
Pressure Regulator
Regulator Bracket
Heater Cabinet
Tee Joint
Test Gauge Connection *
Sediment Trap
Figure 13 - Gas Connection
Reducer Bushing to 1/8" NPT
1/8" NPT Plug Tap
Tee Joint Pipe Nipple Cap
3" Minimum
3/8" NPT Pipe Nipple
Ground Joint Union
Manual Shutoff Valve *
Inlet Pipe From Gas Meter (7" W.C. to
10.5" W.C. Pressure)
* An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design certified manual shutoff valve from your dealer. See Accessories, page 19.
CAUTION: Use pipe joint seal­ant that is resistant to liquid pe­troleum (LP) gas.
10
105566
Page 11
OWNER’S MANUAL
O
S
INSTALLATION
Continued
CHECKING GAS CONNECTIONS
WARNING: Test all gas pip­ing and connections for leaks after installing or servicing. Cor­rect all leaks at once.
WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG (3.5 K Pa)
1. Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 PSIG will damage heater regulator .
2. Cap off open end of gas pipe where manual shutoff valve was connected.
3. Pressurize supply piping system by ei­ther using compressed air or opening main gas valve located on or near gas meter.
4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form­ing show a leak.
5. Correct all leaks at once.
6. Reconnect heater and manual shutoff valve to gas supply . Check reconnected fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 K Pa)
1. Close manual shutoff valve (see Fig­ure 14).
2. Pressurize supply piping system by ei­ther using compressed air or opening main gas valve located on or near gas meter.
3. Check all joints from gas meter to manual shutoff valv e (see Figure 15). Apply mix­ture of liquid soap and water to gas joints. Bubbles forming show a leak.
4. Correct all leaks at once.
Pressure Testing Heater Gas Connections
1. Open manual shutoff valv e (see Figure 14).
2. Open main gas valve located on or near gas meter.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from manual shutoff valve to control valve (see Figure 15). Apply mixture of liquid soap and wa­ter to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, page 12 for non-thermostat models or page 13 for thermostat models). Check the rest of the internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appliance, page 13 for non-thermo­stat models or page 14 for thermostat models).
8. Replace front panel.
Open
PO
Manual Shutoff Valve
P
Closed
Figure 14 - Manual Shutoff Valve
Control Valve Location Thermostat Models
Gas Meter
Manual Shutoff Valve
Control Valve Location Non-Thermostat Models
Figure 15 - Checking Gas Joints
OPERATING HEATER
NON-THERMOSTAT MODELS FA-3B AND FA-5B
FOR YOUR SAFETY
READ BEFORE
LIGHTING
WARNING: If you do not fol­low these instructions exactly, a fire or explosion may result caus­ing property damage, personal injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting the pilot, follow these instructions exactly .
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas sup­plier, call the fire department.
C. Use only your hand to push in or turn
the gas control knob. Ne ver use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part
has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un­der water.
Continued
105566
11
Page 12
INFRARED NATURAL GAS HEATER
OPERATING HEATER
Continued
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information page 11, column 3.
2. Make sure manual shutoff valve is fully open.
3. T urn control knob clockwise to the OFF position.
4. Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in­formation page 11, column 3. If you don’t smell gas, go to the next step.
5. Press in and turn control knob coun­terclockwise to PILOT/IGN position. Press in control knob for five(5) seconds (see Figure 18).
Note:
You may be running this heater for the first time after hooking up to gas supply . If so, you may need to press in control knob for 30 seconds. This will allow air to bleed from the gas system.
• If control knob does not pop up when
released, contact a qualified service person or supplier for repairs.
6. Release downward pressure on con­trol knob and turn clockwise to OFF position.
7. Press in control knob and turn back to PILOT/IGN. This will cause the piezo ignitor to spark and light the pilot gas. If needed, repeat steps 5 through 7 until pilot lights.
Note:
If pilot does not stay lit, refer
to Troubleshooting, pages 15 through
17. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. T o light pilot with match, see Manual Lighting Procedure.
8 . Keep control knob pressed in for 30
seconds after lighting pilot. After 30 seconds, release control knob.
Note:
If pilot goes out, repeat steps
3 through 7.
Figure 16 - Control Knob In The OFF Position
Ignitor Electrode
Thermocouple
Figure 17 - Pilot
Pilot Burner
TO SELECT
HEATING LEVEL
WARNING: When running heater, set control knob at LOW, MEDIUM, or HIGH locked posi­tions. Never set control knob be­tween locked positions. Poor combustion and higher levels of carbon monoxide may result.
CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.
Control
Knob FA-3B FA-5B
Slightly press in control knob and turn coun­terclockwise to the LOW, ME­DIUM, or HIGH positions (see Figure 18).
IMPORTANT:
sure while turning control knob. Control knob will lock at the desired position.
Release downward pres-
TO TURN OFF GAS TO
APPLIANCE
Shutting Off Heater
1. T urn control knob clockwise to the OFF position.
2. Turn off all electric power to the ap­pliance if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise to the PILOT/IGN position.
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under Light­ing Instructions.
2. With control knob pressed in, strike match. Hold match to pilot until pi­lot lights.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
LOW
MED
HIGH
OFF
Figure 18 - Burner Patterns
12
105566
Page 13
OWNER’S MANUAL
OPERATING HEATER
Continued
THERMOSTAT MODELS FAS-3B AND FAS-5B
FOR YOUR SAFETY
READ BEFORE
LIGHTING
WARNING: If you do not fol­low these instructions exactly, a fire or explosion may result caus­ing property damage, personal injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting the pilot, follow these instructions exactly .
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas sup­plier, call the fire department.
C. Use only your hand to push in or turn
the gas control knob. Ne ver use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part
has been under water . Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas con­trol which has been under water.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information, column 1.
2. Make sure manual shutoff valve is fully open.
3. Push in control knob slightly and turn clockwise to the OFF position. Be sure that the tempera­ture setting knob is set at the line between level 1 and level 7 (see Fig­ure 19).
4. Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in­formation in column 1. If you don’t smell gas, go to the next step.
5. Push in and turn control knob coun­terclockwise to PILOT po­sition. Press in control knob for five(5) seconds.
Note:
You may be running this heater for the first time after hook­ing up to gas supply. If so, you may need to press in control knob for 30 seconds. This will allow air to bleed from the gas system.
6. Release d ow nw ard p ressure on con­trol knob and turn clockwise to OFF position.
7. Press in control knob and turn coun­terclockwise past IGN to PILOT (see Figure 19). This will
cause the piezo ignitor to spark and light the pilot gas. Keep control knob depressed for 10 seconds before re­leasing. If needed, repeat steps 5 through 7 until pilot lights.
6
5
7
1
4
2
3
PILOT
ON
IGN
OFF
Note:
If pilot does not stay lit, refer
to Troubleshooting, pages 15 through
17. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with
Figure 19 - Dual Control for Thermostat Models FAS-3B and FAS-5B
match. To light pilot with match, see Manual Lighting Procedure, page 14.
8 . When pilot is lit, turn the control
Thermocouple
Ignitor Electrode
Pilot Burner
knob to ON position (see Figure 21).
9. To select desired heating level, turn the temperature setting knob coun-
terclockwise between 1 and 7 (see Figure 21).
Figure 20 - Pilot
Temperature Control Setting Knob Knob FAS-3B FAS-5B
PILOT
3
4
2
1
7
6
5
4
3
ON
5
6
ON
7
1
2
IGN
OFF
PILOT
IGN
OFF
ON
OFF
105566
Figure 21 - Burner Patterns
Continued
13
Page 14
INFRARED NATURAL GAS HEATER
OPERATING HEATER
Continued
TO TURN OFF GAS TO
APPLIANCE
Shutting Off Heater
1. T urn control knob clockwise to the OFF position.
2. Turn off all electric power to the ap­pliance if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise to the PILOT position.
THERMOSTAT
CONTROL
OPERATION
The thermostatic control used on these models differs from standard thermo­stats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room tem­perature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The temperature set­ting knob can be set to any comfort level between 1 and 7.
Note:
The thermostat sensing bulb mea­sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca­tion, room size, open air temperatures, etc.) Frequent use of your heater will let you determine your own comfort levels.
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under Light-
ing Instructions, page 13.
2. With control knob pressed in, strike
match. Hold match to pilot until pi­lot lights.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30 seconds, release control knob.
INSPECTING BURNER
Check pilot flame pattern and burner flame pattern often.
PILOT FLAME PATTERN
Figure 22 shows a correct pilot flame pattern. Figure 23 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch­ing the thermocouple. This will cause the thermocouple to cool. When the thermo­couple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 23
• turn heater off (see To Turn Off Gas to Appliance)
• see Troubleshooting, pages 15 through 17
Pilot Burner
Thermocouple
GRH/OV 009GOOD PILOT
Figure 22 - Correct Pilot Flame Pattern
Pilot Burner
Thermocouple
GRH/OV 010BAD PILOT
Figure 23 - Incorrect Pilot Flame Pattern
BURNER FLAME PATTERN
Figure 24 shows a correct burner flame pattern. Figure 25 shows an incorrect burner flame pattern.
If pilot flame pattern is incorrect, as shown in Figure 25
• turn heater off (see To Turn Off Gas to Appliance)
• see Troubleshooting, pages 15 through 17
Figure 24 - Correct Burner Flame Pattern
Figure 25 - Incorrect Burner Flame Pattern
CLEANING AND MAINTENANCE
WARNING: Turn off heater
and let cool before servicing.
CAUTION: You must keep control areas, burner, and circu­lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali­fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, etc.
ODS/PILOT AND BURNER ORIFICE
• Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air to clean.
Exterior
• Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi­net to remove dust.
14
105566
Page 15
OWNER’S MANUAL
TROUBLESHOOTING
Note:
For additional help, visit DESA
International’s Technical Service web site at www.desatech.com.
Note:
All troubleshooting items are listed
in order of operation.
OBSERVED PROBLEM
When ignitor button is pressed in, there is no spark at ODS/pilot
ODS/pilot lights but flame goes out when control knob is released
WARNING: Turn off and un­plug heater and let cool before servicing. Only a qualified ser­vice person should service and repair heater.
POSSIBLE CAUSE
1. Ignitor electrode positioned wrong
2. Ignitor electrode broken
3. Ignitor electrode not connected to igni­tor cable
4. Ignitor cable pinched or wet
5. Broken ignitor cable
6. Bad piezo ignitor
1. Gas supply turned off or manual shutoff valve closed
2. Control knob not fully pressed in while pressing ignitor button
3. Air in gas lines when installed
4. ODS/pilot is clogged
5. Gas regulator setting is not correct
6. Control knob not in pilot position
CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.
REMEDY
1. Replace ignitor
2. Replace ignitor
3. Reconnect ignitor cable
4. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry
5. Replace ignitor cable
6. Replace control valve (piezo is part of control valve)
1. Turn on gas supply or open manual shutoff valve
2. Fully press in control knob while press­ing ignitor button
3. Continue holding down control knob. Re­peat igniting operation until air is removed
4. Clean ODS/pilot (see Cleaning and Maintenance, page 14 ) or replace ODS/ pilot assembly
5. Replace gas regulator
6. Turn control knob to pilot position
When ignitor button is pressed in, there is a spark at ODS/pilot but no ignition
1. Control knob not fully pressed in
2. Control knob not pressed in long enough
3. Manual shutoff valve not fully open
4. Thermocouple connection loose at con­trol valve
5. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob­lem could be caused by one or both of the following:
A) Low gas pressure B) Dirty or partially clogged ODS/pilot
6. Thermocouple damaged
7. Control valve damaged
www.desatech.com
1. Press in control knob fully
2. After ODS/pilot lights, keep control knob pressed in 30 seconds
3. Fully open manual shut-off valve
4. Hand tighten until snug, then tighten 1/4 turn more
5. A) Contact local natural gas company B) Clean ODS/pilot (see Cleaning and Maintenance, page 14) or replace ODS/ pilot assembly
6. Replace thermocouple
7. Replace control valve
Continued
105566
15
Page 16
INFRARED NATURAL GAS HEATER
TROUBLESHOOTING
Continued
OBSERVED PROBLEM
Burner(s) does not light after ODS/pilot is lit
Delayed ignition of burner(s)
Burner backfiring during combustion
Burner plaque(s) does not glow
Slight smoke or odor during initial operation
POSSIBLE CAUSE
1. Burner orifice(s) is clogged
2. Burner orifice(s) diameter is too small
3. Inlet gas pressure is too low
1. Manifold pressure is too low
2. Burner orifice(s) is clogged
1. Burner orifice(s) is clogged or damaged
2. Burner damaged
3. Gas regulator defective
1. Plaque damaged
2. Inlet gas pressure is too low
3. Control knob set between locked positions
1. Residues from manufacturing processes
REMEDY
1. Clean burner orifice(s) (see Cleaning and Maintenance, page 14) or replace
burner orifice(s)
2. Replace burner orifice(s)
3. Contact local natural gas company
1. Contact local natural gas company
2. Clean burner orifice(s) (see Cleaning and Maintenance, page 14) or replace burner orifice(s)
1. Clean burner orifice(s) (see Cleaning and Maintenance, page 14) or replace burner orifice(s)
2. Replace burner
3. Replace gas regulator
1. Replace burner
2. Contact local natural gas company
3. Turn control knob until it locks at de­sired setting
1. Problem will stop after a few hours of operation
Heater produces a clicking/ticking noise just after burner is lit or shut off
White powder residue forming within burner box or on adjacent walls or furniture
1. Metal expanding while heating or con­tracting while cooling
1. When heated, vapors from furniture pol­ish, wax, carpet cleaners, etc. turn into white powder residue
www.desatech.com
1. This is common with most heaters. If noise is excessive, contact qualif ied ser­vice person
1. Turn heater off when using furniture polish, wax, carpet cleaners, or similar products
16
105566
Page 17
TROUBLESHOOTING
Continued
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
OWNER’S MANUAL
IMPORTANT:
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
Operating heater where impurities in air exist may create odors. Cleaning
OBSERVED PROBLEM
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
POSSIBLE CAUSE
1. Heater burning vapors from paint, hair spray, glues, etc. See statement above
2. Gas leak. See W arning statement at
top of page
1. Not enough fresh air is available.
2. Low line pressure
3. ODS/pilot is partially clogged
1. Gas leak. See Warning statement at
top of page
2. Control valve defective
1. Foreign matter between control valve and burner
2. Gas leak. See Warning statement at
top of page
IMPORTANT
REMEDY
1. Ventilate room. Stop using odor caus­ing products while heater is running
2. Locate and correct all leaks (see Check- ing Gas Connections, page 11)
1. Open window and/or door for ventilation
2. Contact local natural gas company
3. Clean ODS/pilot (see Cleaning and Maintenance, page 14)
1. Locate and correct all leaks (see Check- ing Gas Connections, page 11)
2. Replace control valve
1. Take apart gas tubing and remove for­eign matter
2. Locate and correct all leaks (see Check- ing Gas Connections, page 11)
Moisture/condensation noticed on windows
105566
1. Not enough combustion/ventilation air
www.desatech.com
17
1. Refer to Fresh Air for Combustion and Ventilation requirements (page 4)
Page 18
INFRARED NATURAL GAS HEATER
SPECIFICATIONS
FA-3B FAS-3B FA-5B FAS-5B
Btu (Variable) 6,000/12,000/18,000 18,000 7,000/18,000/30,000 30,000 Type Gas Natural Only Natural Only Natural Only Natural Only Ignition Piezo Piezo Piezo Piezo Pressure Regulator Setting 6" W.C. 6" W.C. 6" W.C. 6" W.C. Inlet Gas Pressure* (in. of water)
Maximum 10.5" 10.5" 10.5" 10.5" Minimum 7" 7" 7" 7"
Dimensions, Inches (H x W x D)
Heater 23 x 18.75 x 7 23 x 18.75 x 7 23 x 26 x 7 23 x 26 x 7 Carton 26 x 21 x 9 26 x 21 x 9 26 x 28.5 x 9 26 x 28.5 x 9
Weight (pounds)
Heater 19.8 20 28 28.5 Shipping 23.3 23.5 33.5 34
Note
: Dimensions listed are outer most points on the heater (includes control knobs and grill).
* For purposes of input adjustment.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burner(s) will have delayed ignition
• heater will not produce specified heat
When Gas Quality Is Bad
• pilot will not stay lit
• burner(s) will produce flames and soot
• heater will backfire when lit You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local natural gas supplier.
SERVICE PUBLICATIONS
You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.
TECHNICAL SERVICE
You may have further questions about in­stallation, operation, or troubleshooting.
If so, contact DESA International’s Techni­cal Service Department at 1-800-323-5190.
You can also visit DESA International's Technical Service web site at
www.desatech.com.
REPLACEMENT PARTS
Note:
Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealer from whom you purchased this product. If they are unable to supply original replacement part(s), call DESA International’s Technical Service De­partment at 1-800-323-5190 for information.
When contacting your dealer or DESA In­ternational, have ready:
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date Usually, we will ask you to return the defec-
tive part to the factory.
PARTS NOT UNDER WARRANTY
18
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information. When calling DESA Interna­tional, have ready:
• model number of your heater
• the replacement part number
105566
Page 19
ACCESSORIES
Purchase these heater accessories from your local dealer. If they can not supply these accessories, contact your nearest Parts Cen- tral or call DESA International’s Parts De­partment at 1-800-972-7879 for referral in­formation. You can also write to the address listed on the back page of this manual.
MANUAL SHUTOFF VALVE ­GA5010
For all models. Manual shutoff valve with 1/8" NPT tap.
OWNER’S MANUAL
FAN KITS - UH1000FB AND UHS1000FB
For all models. Provides better heat distri­bution. Makes heater more efficient. Com­plete installation and operating instructions included.
Manually controlled - UH1000FB. Includes ON/OFF switch.
Thermostatically controlled - UHS1000FB. Includes three settings: ON/OFF/AUTO.
FLOOR MOUNTING STAND
Models FA-3B and FAS-3B ­UH3000BA Model FA-5B and FAS-5B ­UH5000BA
For locating heater on the floor, away from a wall. Complete installation instructions provided with floor mounting stand.
PARTS CENTRALS
These Parts Centrals are privately owned businesses. They have agreed to support our customer's needs by providing original replacement parts and accessories.
Baltimore Electric
1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department
Portable Heater Parts
342 N. County Road 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-800-362-6951
FBD
1349 Adams Street Bowling Green, KY 42103-3414 502-846-1199 1-800-654-8534
Four Flags Power Products
1115 Stateline Road Niles, MI 49120-4728 616-684-2697 1-800-268-4983 Parts Only
Master Parts Distributors
1251 Mound Avenue NW Grand Rapids, MI 49504-2672 616-791-4760 1-800-446-1446
Washer Equipment Co.
1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911
East Coast Energy Products
707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809
Tarantin Tank Co.
P.O. Box 6129 Freehold, NJ 07728-6129 908-780-9340 1-800-922-0724
Heater & Fireplace Store
1922 N Route 9 Cape May Court, NJ 08210-1110 609-624-0678
Dayton Hardware
P.O. Box 275 North Dayton Station Dayton, OH 45404-0275 All States 937-258-3721 OH 1-800-762-3426
Halco Enterprises
208 Carter Drive, Unit 21 West Chester, PA 19382-4500 610-696-2670 1-800-368-0803
LA Porte's Parts & Service
2444 North 5th Street Hartsville, SC 29550-7704 803-332-0191 Parts Department
Cans Unlimited, Inc.
P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301
105566
19
Page 20
INFRARED NATURAL GAS HEATER
ILLUSTRATED PARTS BREAKDOWN
FA-3B
27
26
4
(See Detail)
28
21
7
1
23
24
25
22
3
5-1 5-2
27
2
4
7
20
17
7
9
7
14
15
16
6
5
20
18
11
10
20
19
8
ODS/Pilot Assembly
Burner Assembly
20
13
12
105566
Page 21
OWNER’S MANUAL
PARTS LIST
FA-3B
KEY PART NO. NO. FA-3B DESCRIPTION QTY.
1 L98409-02 Cabinet Assembly 1 2 L98005-02 Lower Front Panel Assembly 1 3 L98410-02 Deflector Unit 1 4 L98103-03 Burner Assembly 1 5 L98071-01 ODS Pilot Assembly 1 5-1 098514-01 Thermocouple 1 5-2 L98071-07 Ignitor Electrode 1 6 L98072-01 ODS Mounting Bracket 1 7 L98817-01 Self Tapping Screw 7 8 L98034-01 Control Valve 1 9 L98411-01 Ignitor Line 1 10 L98028-01 Control Valve Bracket 1 11 L98054-01 Control Valve Fixed Nut 1 12 L98059-01 Control Valve Main Inlet Nut 1 13 L98115-02 Main Inlet Tube Assembly 1 14 L98124-02 Valve to Regulator Line Assembly 1 15 L98914-01 Pilot Regulator Assembly 1 16 L98125-02 Regulator to ODS Line Assembly 1 17 L98117-02 Burner Gas Line Assembly A 1 18 L98120-02 Burner Gas Line Assembly B 1 19 L98122-02 Burner Gas Line Assembly C 1 20 L99023-01 Injector 3 21 L98061-01 Control Knob 1 22 L98906-01 Control Rod Assembly 1 23 L99029-01 Pressure Regulator 1 24 L98801-01 Washer 2 25 L98806-01 Self Tapping Screw 2 26 L98010-02 Grill Guard 1 27 L98011-01 Grill Fastener 2 28 L98085-01 Mounting Bracket 1
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual.
PARTS AVAILABLE - NOT SHOWN
105566
100642-01 Hardware Assembly 1 104892-39 AGA Decal 1 L98098-01 Gas Instruction Decal 1 L98100-01 Inside Warning Label 1
21
Page 22
INFRARED NATURAL GAS HEATER
ILLUSTRATED PARTS BREAKDOWN
FA-5B
32
31
32
4
(See Detail)
33
26
7
28
1
3
30
29
27
TO "B1"
25
24
21
22
TO "C1"
4
TO "B2"
20
2
7
24
24
9
6
5
7
23
7
11
10
5-1
24
16
18
13
12
15
25
19
17
8
TO "C2"
24
14
5-2
Burner Assembly
22
ODS/Pilot Assembly
105566
Page 23
OWNER’S MANUAL
PARTS LIST
FA-5B
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual.
KEY PART NO. NO. FA-5B DESCRIPTION QTY.
1 L98409-01 Cabinet Assembly 1 2 L98005-01 Lower Front Panel Assembly 1 3 L98410-01 Deflector Unit 1 4 L98103-01 Burner Assembly 1 5 L98071-01 ODS Pilot Assembly 1 5-1 098514-01 Thermocouple 1 5-2 L98071-07 Ignitor Electrode 1 6 L98072-01 ODS Mounting Bracket 1 7 L98817-01 Self Tapping Screw 7 8 L98034-01 Control Valve 1 9 L98411-01 Ignitor Line 1 10 L98028-01 Control Valve Bracket 1 11 L98054-01 Control Valve Fixed Nut 1 12 L98059-01 Control Valve Main Inlet Nut 1 13 L98115-01 Main Inlet Tube Assembly 1 14 L98124-01 Valve to Regulator Line Assembly 1 15 L98914-01 Pilot Regulator Assembly 1 16 L98125-01 Regulator to ODS Line Assembly 1 17 L98116-01 Burner Gas Line Assembly “C” 1 18 L98117-01 Burner Gas Line Assembly “C1” 1 19 L98118-01 Burner Gas Line Assembly “C2” 1 20 L98119-01 Burner Gas Line Assembly “B” 1 21 L98120-01 Burner Gas Line Assembly “B1” 1 22 L98121-01 Burner Gas Line Assembly “B2” 1 23 L98122-01 Burner Gas Line Assembly “A” 1 24 L99023-01 Injector 5 25 L99047-01 “T” Joint 2 26 L98061-01 Control Knob 1 27 L98906-01 Control Rod Assembly 1 28 L99029-01 Pressure Regulator 1 29 L98801-01 Washer 2 30 L98806-01 Self Tapping Screw 2 31 L98010-01 Grill Guard 1 32 L98011-01 Grill Fastener 2 33 L98085-01 Mounting Bracket 1
105566
PARTS AVAILABLE - NOT SHOWN
100642-01 Hardware Assembly 1 104892-42 AGA Decal 1 L98098-01 Gas Instruction Decal 1 L98100-01 Inside Warning Label 1
23
Page 24
INFRARED NATURAL GAS HEATER
15
16
13
19
23
22
11
9
12
21
16
14
10
4
23
20
17
18
ILLUSTRATED PARTS
5
6
30
BREAKDOWN
FAS-3B
4
(See Detail)
2
28
16
29
13
7
29
1
8
9
17
24
24
25
3
16
16
27
26
14-1 14-2
ODS/Pilot Assembly
16
Burner Assembly
24
105566
Page 25
OWNER’S MANUAL
PARTS LIST
FAS-3B
KEY PART NO. NO. FAS-3B DESCRIPTION QTY.
1 L98409-04 Cabinet Assembly 1 2 L98006-02 Front Panel Assembly 1 3 L98410-04 Reflector Unit 1 4 L98103-03 Burner Assembly 1 5 L98135-02 Thermostat Valve Assembly 1 6 L99066-01 Thermostat Valve Base 1 7 L98084-01 Self Tapping Screw 2 8 L98068-01 Thermostat Valve Inlet/Outlet 2 9 L98133-01 Thermostat Outlet Tube Assembly 1 10 L98055-01 4-Way Connector 1 11 L98056-01 4-Way Connector Bracket 1 12 L98057-01 4-Way Connector Fixed Nut 1 13 L98411-01 Ignitor Line 1 14 L98071-03 ODS Pilot 1 14-1 098514-01 Thermocouple 1 14-2 L98071-07 Ignitor Electrode 1 15 L98072-01 ODS Mounting Bracket 1 16 L98817-01 Self Tapping Screw 7 17 L98124-04 Valve to Regulator Gas Line Assembly 1 18 L98914-01 Pilot Regulator Assembly 1 19 L98125-04 Regulator to ODS Line Assembly 1 20 L98117-04 “A” Burner Gas Line Assembly 1 21 L98120-04 “B” Burner Gas Line Assembly 1 22 L98122-04 “C” Burner Gas Line Assembly 1 23 L99023-01 Injector 3 24 L98115-03 Main Inlet Tube Assembly 1 25 L99029-05 Pressure Regulator 1 26 L98801-01 Washer 2 27 L98806-01 Self Tapping Screw 2 28 L98010-04 Grill Guard 1 29 L98011-01 Grill Fastener 2 30 L98085-01 Mounting Bracket 1
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual.
105566
PARTS AVAILABLE - NOT SHOWN
100642-01 Hardware Assembly 1 104892-44 AGA Decal 1 L98098-01 Gas Instruction Decal 1 L98100-01 Inside Warning Label 1 L98080-02 Thermostat Sensing Bulb Clip 2
25
Page 26
INFRARED NATURAL GAS HEATER
ILLUSTRATED PARTS
5
6
35
BREAKDOWN
FAS-5B
33
16
4
(See Detail)
34
13
7
8
9
2
34
17
29
4
1
16
16
32
29
3
30
31
14-1 14-2
ODS/Pilot Assembly
16
TO "C1"
TO "B1"
27
24
27
21
Burner Assembly
28
28
25
23
20
TO "B2"
27
16
TO "C2"
22
13
27
16
19
15
14
18
27
9
12
11
26
10
17
26
105566
Page 27
OWNER’S MANUAL
PARTS LIST
FAS-5B
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual.
KEY PART NO. NO. FAS-5B DESCRIPTION QTY.
1 L98409-03 Cabinet Assembly 1 2 L98006-01 Front Panel Assembly 1 3 L98410-03 Reflector Unit 1 4 L98103-01 Burner Assembly 1 5 L98135-02 Thermostat Valve Assembly 1 6 L99066-01 Thermostat Valve Base 1 7 L98084-01 Self Tapping Screw 2 8 L98068-01 Thermostat Valve Inlet/Outlet Connector 2 9 L98133-01 Thermostat Outlet Tube Assy 1 10 L98055-01 4-Way Connector 1 11 L98056-01 4-Way Connector Bracket 1 12 L98057-01 4-Way Connector Fixed Nut 1 13 L98411-01 Ignitor Line 1 14 L98071-03 ODS Pilot Assembly 1 14-1 098514-01 Thermocouple 1 14-2 L98071-07 Ignitor Electrode 1 15 L98072-01 ODS Mounting Bracket 1 16 L98817-01 Self Tapping Screw 14 17 L98124-03 Valve to Regulator Gas Line Assembly 1 18 L98914-01 Pilot Regulator Assembly 1 19 L98125-03 Regulator to ODS Gas Line Assembly 1 20 L98116-02 Burner Gas Line Assembly “C” 1 21 L98117-01 Burner Gas Line Assembly “C1” 1 22 L98118-01 Burner Gas Line Assyembly “C2” 1 23 L98119-02 Burner Gas Line Assembly “B” 1 24 L98120-01 Burner Gas Line Assembly “B1” 1 25 L98121-01 Burner Gas Line Assembly “B2” 1 26 L98122-03 Burner Gas Line Assembly “A” 1 27 L99023-01 Injector 5 28 L99047-01 “T” Joint 1 29 L98115-03 Main Inlet Tube Assembly 1 30 L99029-05 Pressure Regulator 1 31 L98801-01 Washer 2 32 L98806-01 Self Tapping Screw 2 33 L98010-03 Grill Guard 1 34 L98011-01 Grill Fastener 2 35 L98085-01 Mounting Bracket 1
105566
PARTS AVAILABLE - NOT SHOWN
100642-01 Hardware Assembly 1 104892-46 AGA Decal 1 L98098-01 Gas Instruction Decal 1 L98100-01 Inside Warning Label 1 L98080-02 Thermostat Sensing Bulb Clip 2
27
Page 28
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model Serial No. Date Purchased
Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written
warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
GLO-WARM VENT-FREE NATURAL GAS HEATERS
DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MER­CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. For information about this warranty write:
INTERNATIONAL
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004
www.desatech.com
Patent Pending
105566 01
NOT A UPC
105566-01 L98108-01 REV. B 05/99