Denon AVR-681, AVR-1601, AVR-1801 Service Bulletin

100 Corporate Drive Mahwah, NJ 07430
Service Bulletin
No. : OST-614 Date:
April 27, 2007
_____________________________________________________________
Model: AVR-681, AVR-1601, AVR-1801
Symptom: When the unit is left for longer than 10 minutes after disconnecting
the AC Power Cord, the unit enters the initial mode and no memory backup is carried out.
Solution:
2) Cut the circuit patterns connected to Pins #53 and #54 of IC201.
3) Attach the Rubber Sheet outlined in the Parts section.
4) Solder the lead wire of the Cathode side of Diode so that the Pins #53 and#54 are short circuited. Then, connect the other terminal of the Diode to theJ205.
5) Assemble the unit.
1) Remove the CPU Unit (1U- XXXXX).
Parts:
Ref# Description Part Number
NA 1SR35-400A(T93X) 276 0704 903 NA Rubber Sheet 461 0415 007
Serial Number Range:
• AVR-1601: 00001 ~ 005060 No modification applied.
• AVR-681: 00001 ~ 002000 No modification applied.
• AVR-1801: 000182 ~ 000243 No modification applied.
______________________________________________________________________________________
The information contained in this document is intended for the exclusive use by DENON Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected from disclosure under applicable laws and terms of the DENON Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility will be accepted by DENON for any damage, injury or loss resulting from the misuse of the information contained in this document.