100 Corporate Drive Mahwah, NJ 07430
Service Bulletin
No. : OST-621
Date:
April 27, 2007
_____________________________________________________________
Model: AVR-1601, AVR-1801
Subject: Resistors open.
Symptom: When the Power is turned on, resistors R141 and R142 in the
Power Supply Circuit on the MAIN Unit can fail due to in-rush current which will
cause the Protect circuit to engage.
Solution:
listed below.
Replace the resistors R141 an R142 with the improved resistors
Parts:
FORMER NEW Ref #
R141,
R142
Description Part
Number
RS14B2E1R0JNBST
(1/4W, 1Ω)
963 9003
039
Description Part
Number
RS14B3AR22JNBST
(S)(IW, 0.22 Ω)
244 2043
982
Serial Number Range:
Replace upon customer claim.