Denon AVR-1601, AVR-1801 Service Bulletin

100 Corporate Drive Mahwah, NJ 07430
Service Bulletin
No. : OST-621 Date:
April 27, 2007
_____________________________________________________________
Model: AVR-1601, AVR-1801
Symptom: When the Power is turned on, resistors R141 and R142 in the
Power Supply Circuit on the MAIN Unit can fail due to in-rush current which will cause the Protect circuit to engage.
Solution:
listed below.
Replace the resistors R141 an R142 with the improved resistors
Parts:
FORMER NEW Ref #
R141,
R142
Description Part
Number
RS14B2E1R0JNBST
(1/4W, 1Ω)
963 9003
039
Description Part
Number
RS14B3AR22JNBST
(S)(IW, 0.22 Ω)
244 2043
982
Serial Number Range:
Replace upon customer claim.
______________________________________________________________________________________
The information contained in this document is intended for the exclusive use by DENON Authorized Service Centers and their employees. This document may contain information that is privileged, confidential and may be protected from disclosure under applicable laws and terms of the DENON Service Agreement. Any distribution, disclosure, dissemination or copying of this document and the information it contains is prohibited. No responsibility will be accepted by DENON for any damage, injury or loss resulting from the misuse of the information contained in this document.
CONFIDENTIALITY NOTICE:
Loading...