up by M1178/D1178 Corresponding value
up by M1179/D1179 Corresponding value
, make sure that it is installed in an
for I/O wiring terminals. The specification for the terminals is as shown
isolation unit of the power circuit to prevent the possible instability
繁體中文
繁體中文
SA/SX/SC
130KHz
繁體中文繁體中文
SA/SX/SC
指令集相同)、
,單一輸入或
系列
Specifications
Model
Item
Power supply voltage MPU: 24V DC (-15% ~ +20%) (With DC input reverse polarity protection),
Fuse 2A/250V AC
Power consumption 4W MAX
Insulation resistance 5 MΩ and above at 500V DC (Between all inputs/outputs and earth)
Noise immunity
Grounding
Environment
Vibration/shock resistance Standard: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
Weight (approx. g) 158
Certificates
Input type DC (SINK or SOURCE)
Input current 24V DC 5mA
Active level
Response time
Output type
Rated current
Voltage specification
Max. inductive load
Output protection
Maximum loading
Response time
Battery life:
Temperature (°C)
Life (years) 9 8 6 5
Precision of calendar timer:
At 0°C/32°F, less than -117 seconds error per month.
At 25°C/77°F, less than 52 seconds error per month.
At 55°C/131°F, less than -132 seconds error per month
ESD: 8KV Air Discharge
EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V
Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV
RS: 26MHz ~ 1GHz, 10V/m
The diameter of grounding wire cannot be smaller than the wire diameter of terminals L
and N (All DVP units should be grounded directly to the ground pole).
Operation: 0°C ~ 55°C (temperature), 50 ~ 95% (humidity), pollution degree 2;
Storage: -25°C ~ 70°C (temperature), 5 ~ 95% (humidity)
Input Point Electrical Specification
Off → On,
X0, X1, 18.5V DC and above
X2 ~ X5, 16.5V DC and above
X10, X11, 18.5V DC and above
On → Off,
X0 ~ X5, X10, X11, below 8 V DC
Hardware The constant of filter time is 10ms
X0~X5
Software 0 ~ 20ms (Set by D1020)
Hardware The constant of filter time is 4.7us
X10, X11
Software 0 ~ 1,000 times (Set by D1021)
Transistor
0.3A/1 point @ 40°C (Room Temp.)
When the output of Y0 and Y1 is high-speed pulse above 3KHz, Y0, Y1 ,Y10 and Y11 = 30mA
5 ~ 30V DC
7.2W/24V
Internal None
Outside Rated value according to the load
Y0, Y1 9W/1 point
Y10, Y11 0.9W/1 point
Off → On
On → Off
0 25 50 70
Output Specifications
< 20us
< 1us (Y10, Y11 only)
< 30us
< 1us (Y10, Y11 only)
DVP12SC11T
20.4V~28.8V
DC Input Type
Safety Wiring
Since the PLC is used to control numerous devices, motion of either one device could affect the motion of other
devices. Therefore the breakdown of a device would consequently be detrimental to the whole auto control
system, thus the result is dangerous. Please use the recommended wiring below for the power input
(DVPPS01/DVPPS02):
5
4
8
Guar d
Limi t
MC
NL
Input Point Wiring
The DC power is used for DC input signal. Two types of DC wiring are used: SINK and SOURCE, defined as
follows:
Sink = Current flows into the common terminal S/S Source = Current flows out of common terminal S/S
DC Type
(DC Signal IN)
SINK Mode
24V
0V
2A
Power supply for AC loads
Power Circuit Protection Fuse (3A)
Power indicator
Emergency stop
The machinery must provide a quick manual method
disconnecting all system power.
3
MC
6
S/S
Sinking
X0
Circuit isolation device (System Power Disconnect)
Utilize the electromagnetic contactor and the relay to be the
1
of the system when the power is supplied on and off.
DVPPS01/DVPPS02
7
Earth
Power supply:
AC: 100 ~ 240V AC, 50/60Hz
DC/DC
X0
S/S
Sourcing
Input Point Loop Equivalent Circuit Wiring Loop
+24V
24VD C
24G
S/S
X0
+5V
+24V OV
24VDC
S/S X0 X1 X2
5V
X0
注意事項
本使用說明書僅提供電氣規格、功能規格、安裝配線部份說明,其它詳細之程式設計及指令與
相容,詳細說明請見
DVP-PLC
本機為開放型
外之外殼配線箱內。另必須具備保護措施(如:特殊之工具或鑰匙才可打開)防止非維護人員操作或意外衝
擊本體,造成危險及損壞。
交流輸入電源不可連接於輸入/出信號端,否則可能造成嚴重損壞,請在上電之前再次確認電源配線。請勿
在上電時觸摸任何端子。本體上之接地端子
DVP-SC
8K Steps
輸出最高可達
機,滿足各種應用場合。
產品外觀及各部介紹
電池安裝
電池安裝::::
電池安裝電池安裝
能會消失或被破壞。
1
2
3 VR0:M1178
4
5
6
7
8 RS-232
9
10
11 銘牌
DVP-PLC
應用技術手冊【特殊模組篇】。
應用技術手冊【程式篇】,選購之週邊裝置詳細說明請見該產品隨機手冊或
(OPEN TYPE)
機殼,因此使用者使用本機時,必須將之安裝於具防塵、防潮及免於電擊/衝擊意
務必正確的接地,可提高產品抗雜訊能力。
產品簡介
系列為一12點(8輸入點
的程式記憶體並具有高速脈波輸入
100KHz
+ 4
輸出點)
PLC
主機,除提供豐富的指令集(與
(X10、X11)
及輸出
(Y10、Y11)
。另外配合高速脈波輸出功能,提供定位控制及原點復歸指令。可連接SS系列全系列擴充
,總和頻寬可達
尺寸單位:
更換電池時,請在3 分鐘內完成,否則 PLC 內部資料(包含程式區,萬年曆及停電保持暫存器)有可
電源、運行及錯誤指示燈
RUN/STOP開關
VR1:M1179
DIN
輸出/入端子
輸出/入點指示燈
RS-485
RS-232
啟動/
D1178
對應值
14 DIN軌糟 (35mm)
啟動/
D1179
對應值
軌固定扣
通訊接收
通訊傳送
程式輸出/入通訊口
17
(Rx)
指示燈
19
(Tx)
指示燈
mm
擴充機連接口
12
擴充機定位孔
13
擴充機固定扣
15
RS-485
通訊口
16
電源輸入口
2 pin
脫落式端子(標準附件)
18
電源輸入連接線(標準附件)
電池蓋
20
電池插座連接
21
22
電池座
(Master/Slave)
Warning
This Instruction Sheet only provides descriptions for electrical specifications, general specifications, installation &
wiring. Other detail infromation about programming and intructions is compatible with SA/SX/SC series; please see
PLC Application Manual. For more information about the optional peripherals, please see individual product
instuction shee or “DVP-PLC Application Manual: Special module”.
This is an OPEN TYPE PLC. The PLC should be kept in an enclosure away from airborne dust, humidity, electric
shock risk and vibration. Also, it is equipped with protective methods such as some special tools or keys to open the
enclosure, in order to prevent hazard to users or damage the PLC..
Do NOT connect the AC main circuit power supply to any of the input/output terminals, or it may damage the PLC.
Check all the wiring prior to power up. To prevent any electromagnetic noise, make sure the PLC is properly
grounded . DO NOT touch terminals when power on.
Introduction
Thank you for choosing DELTA’s PLC DVP series. The DVP-SC series has a 12-points (8 input points + 4
outputs) MPU with powerful instructions (the same instruction sets as SA/SX/SC series) for use. It also has an
8K Steps program memory and high-speed pulse inputs(X10 and X11)/outputs (Y10 and Y11). For high-speed
pulse, total bandwidth can up to 130KHz and 100KHz maximum for single input/output. Besides, it also
provides instructions of position control and zero point return to use with high-speed pulse output. It could
connect all extension units of DVP-SS series for various applications.
Product Profile and Outline
Battery replacement: Battery replacement must be finished within 3 minutes, or the internal data of the PLC
(including the program area, RTC and latched registers) could be lost or destroyed.
1 Status indicators of POWER, RUN and ERROR 12 Extension port for wire to connect extension module/unit
2 RUN/STOP switch 13 Mounting hole
3 VR0: Start-
4 VR1: Start-
5 DIN rail clip 16 RS-485 communication port (Master/Slave)
6 I/O terminals 17 DC Power input
7 I/O point indicators 18 2 pin removable terminal (standard accessory)
8 COM1 (RS-232) (Rx) indicator 19 Power input cable (standard accessory)
9 COM2 (RS-485) (Tx) indicator 20 Battery cover
10 COM1 (RS-232) port 21 Battery socket connection
11 Nameplate 22 Battery holder
Unit: mm
DIN rail track (35mm)
Extension unit clip
ENGLISH
Model Name & I/O Configuration
Model
DVP12SC11T 24V DC
Input/Output Specification
Input Unit Output Unit
Power
Points Type Points Type
24V DC
6
Sink/Source
X0~X5
24VDC
Sink/Source
2
Hi-speed
X10, X11
Transistor
2
Y0, Y1
Transistor
2
Hi-speed
Y10, Y11
I/O Configuration
S/S
X0
X1
X2
X3
X4
X5
X10
X11
DC Type
C0
Y0
C1
Y10
C3
Y11
(DC Signal IN)
SOURCE Mode
Output Point Wiring
Installation & Wiring
4.1 PLC Mounting Arrangements and Wiring Notes
1. When installing the DVP series PLC
enclosure with sufficient space (as shown on the right) to its
surroundings so as to allow heat dissipation.
2. I/O signal wires or power supply should not run through the same
multi-wire cable or conduit.
3. Please use 22-16AWG (1.5mm) wiring (either single or multiple core)
on the right.
4. PLC terminal screws should be tightened to a torque of 1.95 kgin-lbs).
5. Use copper conductor only, 60/75°C
4.2 Wiring Notes
Environment
1. DO NOT store the PLC in an atmosphere that is dusty, smoky, with metallic debris or corrosive or
flammable gases.
2. DO NOT store the PLC in an environment with high temperature or high humidity.
3. DO NOT install the PLC on a shelf or on an unstable surface.
Power Input Wiring
DVP-SC series input power supply is DC input. Please take a note of listed items when operating DVP-SC
Series.
1. Please make sure the power is at terminals 24V DC and 0V (power range is 20.4 ~ 28.8V DC). When
voltage is lower than 20.4V DC, PLC will stop operating, all outputs will be Off and ERROR LED will flash
continuously.
2. If the power-cut time is less than 10ms, the PLC still operates unaffectedly. If the power-cut time is too
long or the power voltage drops, the PLC will stop operating and all the outputs will be Off. Once the
power is restored, the PLC will return to operation automatically. (There are latched auxiliary relays and
registers inside of the PLC, please be aware when programming.)
D
DD
DVP
MP U
D
D > 50 m m
1. Two types of DVP-SC Series PLC output modules Transistor. For the electrical specification, please refer
to the function specification.
2. Please watch out the connection of common terminals while wire the outputs. Output terminal Y0 uses one
common terminal C0, Y1 uses C1, and Y10 uses C2, Y11 uses C3, as shown below:
Action indication: When the output point is active, the corresponding indicator at the front panel will be on.
3. Isolated circuit: The optical coupler is used to isolate signals between PLC internal circuits and input
modules.
Input/Output Wiring
High-spe ed pulse
inputs
High-spe ed pulse
inputs
Input Point Loop Equivalent Circuit Wiring Loop
+24V
24VD C
24G
S/S
X0
DVP-**-**-11-T
LED
24VDC
S/S
X0
X1
X5
100KHz
100KHz
X10 and X11 can be used a s common inp uts
or inputs of hi gh-spee d counter
X10
X11
+5V
T
R
G
TRANSISTOR OUTPUT
24VDC
LOAD
Y0
< 0.3A
C0
LOAD
Y0
C0
Y1
C1
Y10
CH0
C2
Y11
CH1
C3
Y10 and Y11 can be used as c ommon outp uts or
high-spe ed pulse out pus used wi th positi on cont rol
30mA~0.3 A
X0+24V OV
Source Type
High-spe ed pulse
outputs
100KHz
outputs
100KHz
電氣規格
機種
項目
電源電壓 主機:
電源保險絲容量
消耗電力
絕緣阻抗
雜訊免疫力
接地
操作/儲存環境
耐振動/衝擊
重量(約
輸入形式 直流(
輸入電流
動作位準
反應時間
輸出點形式 電晶體
電流規格
電壓規格
最大負載
反應時間
電池壽命
電池壽命::::
電池壽命電池壽命
溫度
(°C) 0 25 50 70
壽命
(年) 9 8 6 5
萬年曆的精度
萬年曆的精度((((秒秒秒秒):
萬年曆的精度萬年曆的精度
在0°
C/32°F
在25°
在55°
24V DC (-15% ~ +20%)
2A/250V AC
4W MAX
5 M
Ω以上(所有輸出/入點對地之間
ESD: 8KV Air Discharge
EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V
Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV
RS: 26MHz ~ 1GHz, 10V/m
接地配線之線徑不得小於電源端
操作:
0°C ~ 55°C
儲存:
-25°C ~ 70°C
國際標準規範
, g)
158 (g)
SINK或SOURCE)
24V DC 5mA約10 ms
Off → On,
X0、X1為18.5V DC以上
X2 ~ X5為16.5V DC以上
X10、X11為18.5V DC以上
On → Off,
X0 ~ X5、X10、X11為8V DC以下
一般輸入
X0 ~ X5
高速輸入
X10、X11 軟體 由D1021作0 ~ 1,000
0.3A/1點@ 40°C
高速脈波輸出
Y0、Y1及Y10、Y11為30mA
30V DC
一般輸出
9W/1點
高速輸出
0.9W/1點
一般輸出
Off→On 20us, On→Off 30us
高速輸出
Off→On 1us, On→Off 1us
):
):):
時,每月最大誤差
-117秒。
時,每月最大誤差52秒。
時,每月最大誤差
-132秒。
C/77°F
C/131°F
DVP12SC11T
(具直流輸入電源極性反接保護)
500V DC)
L, N
之線徑(多台
PLC
(濕度),污染等級
(濕度)
10 ms
4.7us
同時使用時,請務必單點接地)
2
的調整
次的調整
(溫度),
50 ~ 95%
(溫度),
5 ~ 95%
IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
輸入點電氣規格
硬體 濾波時間常數
軟體 由
D1020可作0 ~ 20 ms
硬體 濾波時間常數
輸出點電氣規格
3KHz
以上時
機種型號與
機種
機種
機種機種
DVP12SC11T 24V DC
安裝及配線
4.1
盤內安裝及配線
1. PLC
在安裝時,請裝配於封閉式之控制箱內,其周圍應保持一定
之空間(如右圖所示),以確保
2.
在配線時請勿將輸入點信號線與輸出點或電源等動力線置於同一
線糟內。
3.
輸出/入配線端請使用
端子規格如左所示。
4. PLC
端子鏍絲扭力為
5.
只能使用
4.2
注意事項
使用環境
1.
請勿將
2.
請勿將
3.
請勿將
電源端輸入配線
SC
機種為直流電源輸入,在使用上應注意下列事項:
1.
電源請接於
轉,輸出全部
2.
當停電時間低於
出全部
用者在作程式設計規劃時應特別注意使用。)
I/O配置
輸入
輸入////輸出規格
輸出規格
輸入輸入
輸出規格輸出規格
輸入單元
電源
點數 形 式 點數 形 式
一般輸入
光耦隔離
6
2
X0 ~ X5
高速輸入
高速光耦隔離
X10、X11
2
2
PLC
散熱功能正常。
22-16AWG (1.5mm)
1.95 kg-cm (1.7 in-lbs)。
60/75
°C
的銅導線。
PLC
裝置於落塵大、油煙、金屬性粉塵及腐蝕性或可燃性氣體的環境當中。
PLC
裝置於高溫、結露之環境。
PLC
裝置有直接振動及衝擊的場所。
24VDC及0V
Off,ERROR LED
10ms時,PLC
Off
,當電源恢復正常時,
單蕊祼線或多蕊線,
兩端,電源範圍為
20.4 ~ 28.8V DC
快速閃爍。
不受影響繼續運轉,當停電時間過長或電源電壓下降將使
PLC
亦自動回復運轉。(
輸出單元
一般輸出
電晶體模組
Y0、Y1
高速輸出
高速電晶體模組
Y10
、
Y11
S/S
X0
X1
X2
X3
X4
X5
X10
X11
D
DVP
MPU
D
,當電源電壓低於
20.4V DC時,PLC
PLC
內部具有停電保持的輔助繼電器及暫存器,使
DD
I/O
配置
配置
配置配置
D > 50 mm
PLC
C0
C2
C3
會停止運
停止運轉,輸
輸入點回路等效電路
+24V
直流形式
(
DC Signal IN
)
SOURCE模式
輸出點之配線
1. DVP-SC系列PLC
2.
輸出端在實際配線時,應特別注意共用端的連接,輸出端Y0用一個C0共
C3
,如下圖所示:
動作指示:當輸出點動作時,正面的該點指示
3.
隔離
回路:
PLC
輸入/輸出回路配線
高速脈波輸入
100KHz
高速脈波輸入
100KHz
X10,X11
或高速計數 器作為 高速計輸入端
24VDC
0V
S/S
X0
DVP-**-**-11-T
LED
SOURCE
+5V
T
R
G
TRANSISTOR OUTPUT
輸出模組:電晶體,其相關電氣規格請參考功能規格部份。
燈亮
內部回路與輸入模組之間使用光耦合器作信號隔離。
S/S
X0
X1
X5
可為一般輸 入點使用
,
X10
X11
特
殊
高
速
計
數
處
理
0V S/S X0 X1 X2+24V
24VDC
LOAD
Y0
< 0.3A
C0
同端,Y1用C1,Y2用C2,Y3用
Y0
C0
Y1
C1
Y10
高
速
脈
C2
波
輸
出
運
Y11
算
C3
Y10,Y11
作為高速脈 波輸出使用
配線回路
Source Type
30mA~0.3A
LOAD
CH0
CH1
可為一般輸 出點使用
5VDC ~30V DC
100KHz
高速脈波輸出
100KHz
,
電氣規格
项目
电源电压
电源保险丝容量
消耗电力
绝缘阻抗
噪声免疫力
接地
操作/储存环境
耐振动/冲击
重 量(约
输入形式 直流(
输入电流
动作位准
反应时间
输出点形式 晶体管
电流规格
电压规格
最大负载
反应时间
电池寿命
电池寿命::::
电池寿命电池寿命
温度
寿命
万年历的精度
万年历的精度((((秒秒秒秒):
万年历的精度万年历的精度
在
0°C /32
在
25°C /77
在
55°C /131
机种
主机
:
24V DC (-15% ~ +20%)
2A/250V AC
4W MAX
5 M
Ω以上(所有输出/入点对地之间
ESD: 8KV Air Discharge
EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V
Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV
RS: 26MHz ~ 1GHz, 10V/m
接地配线之线径不得小于电源端
操作:
0°C ~ 55°C
, g)
24V DC 5mA约10 ms
(°C) 0 25 50 70
(年) 9 8 6 5
°F
时,每月最大误差
°F
时,每月最大误差52秒。
°F
时,每月最大误差
(温度),
储存:
-25°C ~ 70°C
(温度),
国际标准规范
IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
158 (g)
SINK或SOURCE)
Off → On,
X0、X1为18.5V DC以上
X2 ~ X5为16.5V DC以上
X10、X11为18.5V DC以上
On → Off,
X0~X5、X10、X11为8V DC以下
一般输入
X0 ~ X5
高速输入
X10、X11
0.3A/1点@ 40°C
高速脉波输出
3KHz
以上时
Y0、Y1及Y10、Y11为30mA
30V DC
一般输出
9W/1点
高速输出
0.9W/1点
一般输出
Off→On 20us, On→Off 30us
高速输出
Off→On 1us, On→Off 1us
):
):):
-117秒。
-132秒。
DVP12SC11T
(具直流输入电源极性反接保护)
500V DC)
L, N
之线径(多台
50 ~ 95%
(湿度),污染等级
5 ~ 95%
(湿度)
输入点电气规格
硬件 滤波时间常数
软件 由
硬件 滤波时间常数
软件 由
D1020可作0 ~ 20 ms
D1021作0 ~ 1,000
输出点电气规格
10 ms
4.7us
PLC
同时使用时,请务必单点接地)
2
的调整
次的调整
直流电源
输入型式
20.4V~28.8V
24V
0V
2A
S/S X0 X1 X2
5V
DC/DC
安全配线回路
由于
个自动控制系统失控,甚至造成危险。所以在电源端输入回路
输入点之配线
输入点之入力信号为直流电源DC输入,DC型式共有两种接法:
DC
(
DC Signal IN)
PLC
控制许多装置,任一装置的动作可能都会影响其它装置的动作,因此任一装置的故障都可能会造成整
5
4
8
2
Guard
Limit
MC
3
MC
NL
7
6
型式,
DC
型式共有两种接法,
Sink =
SINK及SOURCE
电流流入共享端
S/S Source =
S/S
Sinking
X0
输入点回路等效电路
+24V
24VDC
直流形式
SINK模式
0V
S/S
X0
(DVPPS01/DVPPS02)
交流电源负载
电源回路保护用保险丝(3A)
1
电源指示灯
紧急停止
为预防突发状况发生,设置一紧急停止按钮,可在状况发生
时,切断系统电源。
1
系统回路隔离装置
DVPPS01/DVPPS02本体
接地
电源供应:
交流(AC):
,其定义如下:
使用电磁接触器、继电器等开关作为系统电源回路隔离装置,
可防止电源断续供应时,造成系统的不稳定。
100 ~ 240V AC, 50/60Hz
SINK及SOURCE
电流流出共享端
SINK
+5V
OV S/S X0 X1 X2+24V
24VDC
,建议配置如下的保护回路:
,其定义如下:
X0
S/S
Sourcing
配线回路
S/S
Sink Type
20.4V~28.8V
直流電源
輸入型式
安全配線回路
由於
自動控制系統失控,甚至造成危險。所以在電源端輸入回路
輸入點之配線
輸入點之入力信號為直流電源DC輸入,DC型式共有兩種接法:
DC
(
DC Signal IN
PLC
控制許多裝置,任一裝置的動作可能都會影響其它裝置的動作,因此任一裝置的故障都可能會造成整個
5
4
8
Guard
Limit
MC
NL
6
型式,
DC
型式共有兩種接法,
Sink =
電流流入共用端
直流形式
)
SINK模式
24V
0V
2A
MC
1
2
3
S/S
Sinking
X0
MC
1
7
SINK及SOURCE
S/S Source =
輸入點回路等效電路
+24V
24VDC
0V
S/S
X0
S/S
X0 X1 X2
5V
DC/DC
(DVPPS01/DVPPS02)
交流電源負載
電源回路保護用保險絲(3A)
電源指示燈
緊急停止
為預防突發狀況發生,設置一緊急停止按鈕,可在狀況發生時,
切斷系統電源。
系統回路隔離裝置
使用電磁接觸器、繼電器等開關作為系統電源回路隔離裝置,可
防止電源斷續供應時,造成系統的不穩定。
DVPPS01/DVPPS02本體
接地
電源供應:
交流(AC):
,其定義如下:
SINK
+5V
100 ~ 240V AC, 50/60Hz
SINK及SOURCE
24VDC
,建議配置如下的保護回路:
,其定義如下:
電流流出共用端
S/S
X0
S/S
Sourcing
配線回路
OV S/S X0 X1 X2+24V
Sink Type
简体中文
简体中文
SA/SX/SC
130KHz
,单一输入或输出最
)
)
SA/SX/SC
。
指令集相同)、
简体中文简体中文
機種型號與
系
8K
机种
机种
机种机种
DVP12SC11T 24V DC
安裝及配線
4.1
盘内安装及配线
1. PLC
在安装时,请装配于封闭式之控制箱内,其周围应保持一定之空
间(如下图所示),以确保
2.
在配线时请勿将输入点信号线与输出点或电源等动力线置于同一线
糟内。
3.
输出/入配线端请使用
规格如左所示。
4. PLC
端子镙丝扭力为
5.
只能使用
4.2
注意事项
使用环境
1.
请勿将
2.
请勿将
3.
请勿将
电源端输入配线
SC
机种为直流电源输入,在使用上应注意下列事项:
1.
电源请接于
行,输出全部
2.
当停电时间低于
出全部
用者在作程序设计规划时应特别注意使用。)
I/O配置
输入
输入
////
输出规格
输出规格
输入输入
输出规格输出规格
输入单元
输出单元
电源
点数 形式 点数 形式
一般输入
6
光耦隔离
X0 ~ X5
高速输入
2
高速光耦隔离
X10、X11
一般输出
2
晶体管模块
Y0、Y1
高速输出
2
高速晶体管模块
Y10、Y11
PLC
散热功能正常。
22-16AWG (1.5mm)
1.95 kg-cm (1.7 in-lbs)。
60/75
°C
的铜导线。
PLC
装置于落尘大、油烟、金属性粉尘及腐蚀性或可燃性气体的环境当中。
PLC
装置于高温、结露之环境。
PLC
装置有直接振动及冲击的场所。
24VDC及0V
Off,ERROR LED
10ms时,PLC
Off
,当电源恢复正常时,
单蕊祼线或多蕊线,端子
两端,电源范围为
20.4 ~ 28.8V DC
快速闪烁。
不受影响继续运行,当停电时间过长或电源电压下降将使
PLC
亦自动回复运行。(
,当电源电压低于
PLC
内部具有停电保持的辅助继电器及寄存器,使
I/O
配置
配置
配置配置
S/S
X0
X1
X2
X3
X4
X5
X10
X11
D
DD
DVP
MPU
D
20.4V DC时,PLC
PLC
C3
会停止运
停止运行,输
注意事項
本使用说明书仅提供电气规格、功能规格、安装配线部份说明,其它详细之程序设计及指令与
列兼容,详细说明请见
DVP-PLC
本机为开放型
击意外之外壳配线箱内。另必须具备保护措施(如:特殊之工具或钥匙才可打开)防止非维护人员操作或意
外冲击本体,造成危险及损坏
交流输入电源不可连接于输入/出信号端,否则可能造成严重损坏,请在上电之前再次确认电源配线。请勿
在上电时触摸任何端子。本体上之接地端子
產品簡介
DVP-SC
Steps
的程序内存并具有高速脉冲输入
高可达
100KHz
足各种应用场合。
产品外观及各部介绍
电池安装
电池安装::::
电池安装电池安装
能会消失或被破坏。
1
电源、运行及错误指示灯
2
RUN/STOP开关
3
VR0;M1178
4
VR1:M1179
5
DIN
6
输出/入端子
7
输出/入点指示灯
8
RS-232
9
RS-485
10
RS-232
11
铭牌
DVP-PLC
应用技术手册【特殊模块篇】
(OPEN TYPE)
系列为一12点(8输入点+4输出点)
。另外配合高速脉冲输出功能,提供定位控制及原点复归指令。可连接SS系列全系列扩展机,满
应用技术手册【程序篇】,选购外围装置详细说明请见该产品随机手册或
。
机壳,因此使用者使用本机时,必须将之安装于具防尘、防潮及免于电击/冲
。
务必正确的接地,可提高产品抗噪声能力
(X10、X11)
PLC
及输出
主机,除提供丰富的指令集(与
(Y10、Y11)
,总和频宽可达
尺寸单位:
更换电池时,请在3分钟内完成,否则
激活
/
D1178
对应值
激活
/
D1179
对应值
轨固定扣
通讯接收
通讯传送
程序输出/入通讯口
(Rx)
指示灯
(Tx)
指示灯
mm
PLC
内部资料(包含程序区,万年历及停电保持寄存器)有可
12
扩展机连接口
13
扩展机定位孔
14
DIN轨糟 (35mm)
15
扩展机固定扣
16
RS-485
通讯口
(Master/Slave)
17
电源输入口
18
2 pin
脱落式端子(标准附件
19
电源输入连接线(标准附件
20
电池盖
21
电池插座连接
22
电池座
直流形式
(
DC Signal IN
SOURCE模式
输出点之配线
1. DVP-SC系列PLC
2.
输出端在实际配线时,应特别注意共享端的连接,输出端Y0用一个C0共同端,另外Y1用C1,Y2用C2,
Y3用C3
动作指示:当输出点动作时,正面的该点指示灯亮。
3. 隔离
回路:
输入/输出回路配线
高速脉冲输入
100KHz
高速脉冲输入
100KHz
X10,X11
速计数器 ,作为高速计数 输入端
输入点回路等效电路
24VDC
DVP-**-**-11-T
SOURCE
+5V
T
R
LED
G
TRANSISTOR OUTPUT
+24V
0V
)
S/S
X0
输出模块:晶体管,其相关电气规格请参考功能规格部份。
,如下图所示:
PLC
内部回路与输入模块之间使用光耦合器作信号隔离。
24VDC
S/S
X0
X1
X5
X10
X11
可为一般输 入点使用或高
配线回路
0V
X0 X1 X2+24V
S/S
24VDC
Y0
< 0.3A
C0
Source Type
LOAD
30mA~0.3A
LOAD
Y0
5VDC~30VDC
C0
Y1
C1
Y10
高
速
脉
冲
输
出
运
特
算
殊
高
速
计
数
处
理
CH0
C2
Y11
CH1
C3
Y10,Y11
或配合定 位控制指令,
作为高速 脉冲输出使用
高速脉冲输出