Features:
Ease of wire connection to
terminals
Comes with detachable
connectors
Overload, Overvoltage &
Thermal protection
Efficiency > 89%
Power boost 150% for 3
seconds
Expected life time: 10
years
Redundancy: Yes (with
external ORing diode)
RoHS & IP20 compliant
Meet Energy Star Level 5
3 years warranty
Switch Mode Power Supply DRP024V060W1BA
60W 1Phase CliQ ll DIN Rail
DRP024V060W1BA
Summary
The new CliQ II DRP024V060W1BA is the
latest offering from one of the world’s largest
power supply manufacturers - Delta.
The product offers a nominal output voltage of
24 V, a wide temperature range from -20°C to
+80°C and a minimum holdup time of 20 ms.
The state-of-the-art design is made to
withstand harsh industrial environments. The
rugged, ultra-compact metal case is shock and
vibration resistant according to IEC60068-2.
1/13 Rev: 00,
1/10/2011
The 60 watts DIN Rail power supply provides
overvoltage, overload and thermal protection.
Due to the wide input voltage range from 85
to 264 VAC, the Delta’s CliQ II power supply is
worldwide usable.
It also comes with multiple output terminals
for fast wiring and easy installation.
Nominal input voltage and frequency
85-264VAC (120 – 375 VDC)
1.5A max @115VAC, 1.0A max @230VAC
Inrush current limitation. I2t (+25°C) typ.
Mains buffering at nominal load (typ.)
> 20ms @ 115VAC, > 125ms @ 230VAC
Recommended backup fuse: Power circuit-breaker characteristic
Nominal output voltage UN / tolerance
Setting range of the output voltage
Startup with capacitive loads
Max. power dissipation idling / nominal load approx.
Residual ripple / peak switching (20 MHz) (at nominal values)
Can be connected in parallel for redundancy and increased capacity
YES with ORing Diode or Redundancy module
Surge voltage protection against internal surge voltages
Electrical equipment of machines
IEC60204-1 (overvoltage category III)
Safety transformers for switched-mode power supply units
Electrical safety (of information technology equipment)
TUV BAUART to EN60950-1, UL/C-UL recognized to
UL60950-1, CSA C22.2 No. 60950-1,
CB scheme to IEC60950-1
Industrial Control Equipment
UL / C-UL Listed UL508 and CSA C22.2 No. 107.1-01, CSA to
CSA C22.2 No.107.1-01 (file no. 181564)
Electronic equipment for use in electrical power Installations
PELV (EN60204), SELV (EN60950)
Protection against electric shock
Protection against shock currents, basic requirements for protective
separation in electrical equipment
VDE 0106-101
Limitation of mains harmonic currents
Switch Mode Power Supply DRP024V060W1BA
Technical Data
2/13 Rev: 00,
1/10/2011
Isolation voltage:
Input / output type test/routine test
Input / PE type test/routine test
output / PE type test/routine test
4 KVAC / 3 KVAC
1.5 KVAC / 1.5 KVAC
1.5 KVAC / 500 VAC
Class I with PE connection
Ambient temperature (Operating)
Ambient temperature (Storage)
-20°C to 80°C (> 50°C de-rating)
-25°C to 85°C
Humidity at 25°C, non-condensing
Vibration (Non-Operating)
10Hz to 500Hz @ 30 m/ S2 (3G peak); displacement of 0.35mm;
60min per axis for all X, Y, Z direction. in acc. with IEC 68000-2-6.
Shock (in all directions)
30G (300m/S2) in all directions according to IEC60068-2-27
3K3 according to EN 60721
In conformance with EMC guideline 89/336/EEC and low
voltage directive 73/23/EEC
EMC (electromagnetic compatibility)
DINRAIL 1AC / 24V DC / 2.5A (EOE11010248)
Immunity to interference according to EN 61000-6-2
EN 61000-4-2 1) Housing
Discharge of static electricity (ESD) Contact discharge:
Air Discharge:
EN 61000-4-3 1) Housing
Radiate Field Immunity Frequency/Field intensity:
LEVEL 3
80MHz - 1GHz / 10V/M with 1kHz tone / 80% modulation
EN 61000-4-4 1)
Fast transients (Burst):
EN 61000-4-5 1)
Surge voltage Immunity (Surge):
2KV
3)
/ 2KV
4)
(Level 3)
EN 61000-4-6 1) I/O:
Conducted Immunity Frequency / Uo:
Level 3
0.15MHz - 80MHz / 10Vrms.
EN 61000-4-11 2)
Voltage dips
Input: Main Buffering > 20ms.
Noise emission according to EN 61000-6-3
Emitted radio interface
Radio interference voltage
EN55011 (EN55022) CLASS B5
EN55011 (EN55022) CLASS B5
EN55011 corresponds to CISPR11 / EN55022 corresponds to CISPR22 / EN 61000 corresponds to IEC 61000
1) Criterion A: Normal operating behavior within the defined limits.
2) Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
3) Symmetrical: Conductor to conductor.
4) Asymmetrical: Conductor to ground.
5) Class B: Area of application industry and residential.
Switch Mode Power Supply DRP024V060W1BA
3/13 Rev: 00,
1/10/2011
Delta standard –
metal case
Switch Mode Power Supply DRP024V060W1BA
Numbering for DIN Rail Power Supply
For example: DRP024V060W1BA
XX X XXXX XXXX X XX
XX………………….Product Type
XX X XXXX XXXX X XX
X………………….Model
XX X XXXX XXXX X XX
XXXX………………….Voltage
4/13 Rev: 00,
1/10/2011
XX X XXXX XXXX X XX
XXXX……………Watt
XX X XXXX XXXX X XX
X………………….Phase
XX X XXXX XXXX X XX
XX………………….Variation (Eg,